PubMed Health⌕ Search

Biomedical subjects

P Kertes

Publications and source records attributed to P Kertes.

17 recordsLinked to original sources

Phaeochromocytoma in pregnancy.

Hypertension during pregnancy is a common problem, causing significant maternal and fetal morbidity and mortality. Pre-eclampsia is by far the most common cause, affecting 5-10% of primigravid women. Phaeochromocytoma is a rare endocrine tumour causing hypersecretion of noradrenaline, adrenaline and/or dopamine. It is extremely rare during pregnancy and may be misdiagnosed with potentially catastrophic consequences. Delayed diagnosis remains a significant source of maternal and fetal morbidity and mortality. Recognition is critical, as the majority of maternal deaths have occurred when the diagnosis has been overlooked. Diagnosis of phaeochromocytoma is achieved by detecting increased catecholamines and metabolites (metanephrine and normetanephrine) on 24-h urine collection, as these levels are unaffected by pregnancy or pre-eclampsia. Definitive treatment of phaeochromocytoma is surgical and the laparoscopic approach has been shown to be safe and is preferred for most phaeochromocytomas. Medical preparation and treatment of hypertension is essential for safe surgery. Timing of adrenalectomy is either during the second trimester or as a staged procedure after Caesarean section delivery.

Adrenal Gland Neoplasms↗

Bifocal right ventricular cardiac resynchronization therapies in patients with unsuccessful percutaneous lateral left ventricular venous access.

Biventricular cardiac resynchronization therapy (CRT) with a lateral left ventricular (LV) lead cannot always be achieved. We report a single center experience of CRT utilizing a protocol that specifically required the implantation of a bifocal right ventricular (RV) lead system when lateral LV pacing could not be achieved. Consecutive candidates for CRT were included in the study. If strict criteria for lateral LV pacing were not met, they underwent implantation of a bifocal RV lead system with two 7F, active fixation leads, one placed septally at the apex, and the other in the high septal outflow tract. All patients were followed for 12 months and the two groups were compared. A biventricular (BiV) stimulation system was implanted in 44 patients, and a bifocal RV system in six. The demographic characteristics of the two groups were similar. Both groups experienced a similar improvement in functional capacity, increase in 6 minutes walking distance, and decreased need for hospitalizations. The mean increase in LV ejection fraction was 11% in the bifocal RV group versus 10% in the BiV group. Though the tissue Doppler indices of LV synchrony improved earlier in the BiV group, (19% vs 10%) the improvement was similar in both groups at 6 months (23% vs 20%). The clinical improvements conferred by CRT can be matched by a bifocal RV system in selected patients. This alternate approach should be considered when implantation of a LV lateral lead was unsuccessful.

Aged↗

Long-term variations in optimal programming of cardiac resynchronization therapy devices.

The optimal follow-up and long-term programming of cardiac resynchronization therapy (CRT) devices are uncertain. The aim of this study was to quantify the temporal variations in programming parameters to optimize the follow-up of these devices. Before, during, and at specified intervals over 9 months after implant, 40 recipients of CRT devices were studied. At each visit, the patients were tested with a fixed sequence of stimulation parameters during echocardiographic and electrocardiographic (ECG) recordings. The optimal AV delay and inter-ventricular delays (V-V) were determined according to echocardiographic criteria. The echocardiographic data were, in turn, compared with the ECG recordings. Among the 40 patients, the optimal stimulation parameters remained unchanged throughout the follow-up in only three patients. In 18 patients, adjustments were required at each follow-up sessions. There was a trend toward reduction in the left ventricular (LV) predominance of the optimal V-V delay and an increase in the AV delay during follow-up. The mean optimal V-V delay at implant was 22 ms (-12 to +32 ms) with the LV activated first, versus 12 ms (-16 to +32 ms) at 9 months. The mean AV delay at implant was 115 ms versus 137 ms at 9 months. Individual changes could not be accurately predicted. The optimal stimulation parameters for CRT vary over time. Detailed, regular reevaluations, and reprogramming of optimal parameters may be appropriate.

Cardiac Pacing, Artificial↗

Radiofrequency catheter ablation of tachyarrhythmias--adult and paediatric experience.

BACKGROUND AND AIMS: Until recently, curative therapy for supraventricular tachycardia (SVT) was possible only with map-guided cardiac surgery. The ability to ablate permanently the reentrant circuit responsible for tachycardia using radiofrequency electrical current (RF) delivered through a catheter has now allowed cure of SVT by non-surgical means. We present our initial experience with this technique in both adult and paediatric patients. METHODS: In 53 patients of median age 32 years, 56 radiofrequency catheter ablation procedures were performed for control of tachyarrhythmias. Fourteen patients were aged 18 years or less. Indications for RF ablation were SVT due to an accessory pathway (n = 27), SVT due to atrioventricular junctional reentry (AVJRT) (n = 22), incessant SVT (n = 2), ventricular tachycardia (n = 2), and uncontrolled atrial fibrillation (n = 3). General anaesthesia was used in 88% of procedures. Ablation was preceded by electrophysiological testing to confirm tachycardia mechanism in all cases. RESULTS: The ablation procedure was completely successful in 49/56 cases (87.5%) and partially successful in another two cases. Only five procedures (9%) failed. Median procedure time was two hours, median fluoroscopy time was 24 min, and the median number of RF applications was four. There were no major differences in results comparing adult and paediatric patients. A transient ulnar nerve palsy was the only major complication observed. After a follow-up of one to 15 months, tachycardia has recurred in two patients (4%). Of the total 53 patients, 90.5% are currently asymptomatic and off all cardiac drug therapy. RF catheter ablation appears to be an effective, curative, and relatively safe alternative to long term drug therapy in the management of troublesome SVT.

Adolescent↗

Clinical experience with surgery for paroxysmal supraventricular tachycardia: a report of 103 cases.

One-hundred-and-three patients underwent surgery for paroxysmal supraventricular tachycardia (PSVT). In eighty-three patients (81%), PSVT was due to an accessory atrioventricular pathway (Group I) and in 20 (19%) to Atrioventricular Junctional (AV nodal) Reentrant Tachycardia (AVJRT:Group II). Initial surgery successfully divided 77 of 83 accessory pathways, including 58 of 60 left free wall pathways, 12 of 15 posteroseptal pathways, six of seven right free wall pathways and one anteroseptal pathway. Twenty patients had successful surgery for AVJRT. Surgery was performed with low morbidity and no early or late mortality in either group. One patient in each group required permanent pacemaker implantation. Immediate (within one week) postoperative electrophysiological study using epicardial wires was performed in 96% of patients and repeat electrophysiological study six months later was possible in 65/103 (63%) patients. Patients with surgery for accessory pathways were followed-up for a mean 34 +/- 23 months, while those with surgery for AVJRT for a mean of 13 +/- seven months. No patient with successful surgery has had a clinical recurrence of PSVT. Thus the results indicate that surgery is a safe and curative therapy for patients with PSVT.

Adolescent↗

Electrical ablation of posteroseptal accessory pathways.

Electrical ablation of a posteroseptal accessory pathway by delivery of direct current electrical energy at the coronary sinus ostium was attempted in six patients. As a result of 12 procedures in these six patients, the posteroseptal accessory pathway was successfully ablated in one patient. Retrograde conduction only was affected in a further three patients, abolishing paroxysmal supraventricular tachycardia in two and reducing the tachycardia rate in one. One of the six patients developed coronary sinus perforation requiring prompt pericardial aspiration. The procedure is complicated, time consuming, of limited efficacy and coronary sinus perforation is a significant risk. Surgery remains the preferred option as a curative procedure for arrhythmias due to posteroseptal accessory pathway.

Adult↗

The role of permanent pacing after anterior myocardial infarction complicated by transient complete atrioventricular block.

A randomised study was performed to assess the influence of prophylactic permanent pacing on the incidence of late sudden death in patients surviving transient complete atrioventricular block with acute anterior myocardial infarction. Fourteen patients were studied, of whom ten died within two years, confirming the high overall late mortality in this group. The deaths included eight of the nine paced patients, of whom seven died suddenly. We conclude that prophylactic permanent pacing is not warranted in patients surviving transient complete atrioventricular block with acute anterior myocardial infarction.

Adult↗

The porous titanium steroid eluting electrode: a double blind study assessing the stimulation threshold effects of steroid.

A transvenous pacing lead with a porous electrode which slowly elutes the steroid, dexamethasone sodium phosphate, has been developed. Previous investigations show low and constant stimulation thresholds persisting over at least the first two years post-implantation. As it is not known whether this low threshold results from the steroid or electrode configuration, a double blind study was designed to compare the same electrode configuration with and without steroid over a 2-year follow-up period. There were ten patients in each group with similar age, sex, indications for pacing and implantation data. Regular measurements of postoperative pulse duration thresholds were performed using a customized VVIM pulse generator programmed to 1.5 V output. For the first two days post-implantation, there were no statistical differences in the pulse duration thresholds between the two pacing leads. From 2 weeks to 2 years the pulse duration thresholds for the steroid leads remained almost constant, whereas the leads without steroid showed a typical rise. The difference in pulse duration thresholds between the two groups of leads from two weeks onwards confirmed that it was the steroid rather than the electrode configuration which prevented the rise in chronic stimulation threshold.

Aged↗

Rate responsive pacing using a minute ventilation sensor.

Minute ventilation, the product of respiratory rate and tidal volume, correlates directly with oxygen consumption, cardiac output, and heart rate. An implantable pacemaker has been developed which allows variation in pacing rate in response to measured changes in minute ventilation. This single chamber system measures transthoracic impedance between the tip electrode of a standard bipolar lead and the pulse generator case. Low amplitude current pulses (1 mA for 15 microseconds) are generated each 50 msec between the the ring electrode and the case. In the adaptive mode, the pulse generator calculates a rate response factor or slope after maximal exercise. This slope, which describes the relationship between pacing rate and minute ventilation together with the pacing rate limits are the only programmable rate responsive features. Minute ventilation rate responsive systems have been implanted in 12 patients (8 females, 4 males), of mean age 63 years. Indications were His bundle ablation (6), acquired complete heart block (4), and sick sinus syndrome (2). At post-implant exercise testing, pacing rate rose within the first minute. Peak rate and time to upper rate were dependent on workload. After exercise, pacing rate remained at peak for up to 2 minutes before a gradual fall to resting rate. Comparative studies of the minute ventilation and the activity sensor pacing systems in the same patients confirmed that the minute ventilation system more closely parallels normal sinus response to activity. The minute ventilation rate responsive pacing system is simple to programme, no special lead is required and the system is highly physiologic.

Aged↗

Exacerbation of bronchial asthma following treatment with amiodarone. Demonstration of an antiadrenergic effect in vitro.

We describe a patient with bronchial asthma whose respiratory symptoms worsened during treatment and rechallenge with amiodarone. Laboratory studies on cultured pulmonary cells demonstrated an anti-beta-adrenergic effect of amiodarone not due to inhibition of beta-adrenergic receptor binding. Amiodarone should be used with caution in patients with obstructive pulmonary disease.

Amiodarone↗

Comparison of lead complications with polyurethane tined, silicone rubber tined, and wedge tip leads: clinical experience with 822 ventricular endocardial lads.

Lead-related complications have been prospectively studied for 602 unipolar tined endocardial ventricular pacemaker leads implanted over a five-year period. No differences were noted in overall complication rates between 238 polyurethane insulated leads (4.2%) and 364 silicone rubber insulated leads (3.6%). Comparing the total series of 602 tined leads to a retrospective survey of 220 wedge tip leads, a marked reduction in dislodgements (0.3% vs. 7.7%, P less than 0.001) and reoperations (2.0% vs 15.0%, P less than 0.001) was found using tined leads. We conclude that tined ventricular leads are far superior to wedge tip leads with respect to lead complications.

Arrhythmias, Cardiac↗