PubMed HealthSearch

Biomedical subjects

P Koranda

Publications and source records attributed to P Koranda.

6 recordsLinked to original sources

Optimal sampling times for OIH-clearance calculations using a two-compartment/two-sample method.

Orthoiodohippurate (OIH) clearance data obtained with the two-compartment/two-sample method of Lear which uses varying sampling time combinations, were compared with those of the reference two-compartment/multi-sample method of Sapirstein. A total of 35 studies were performed in 33 adult patients. The OIH clearance values determined by the reference method ranged from 107 to 883 ml/min/1.73 m2, with a median of 406 ml/min/1.73 m2. It was ascertained that the precision of the Lear method is partially dependent upon the sampling time combination. The most reliable results with the Lear method in this patient population were obtained by taking a first sample at approximately 8 min p.i., and a second sample at 32 min p.i. or later.

Adult

[Experimental verification of the hepatic perfusion index for monitoring direct liver perfusion by portal blood].

The reliability of HPI measurement was studied in animal experiment. The portal vein of experimental dogs was narrowed by application of a metallic coil. The induced portal hypertension with important hepatofugal collaterals appeared to be a suitable model for the study of changes in HPI. A decrease in the index was statistically significant and corresponded to the hemodynamical efficiency of collateral circulation. The original experiment verified the reliability of HPI for an assessment of direct perfusion of the liver by portal blood.

Animals

Absolute quantitation of gallium-67 citrate accumulation in the lungs and its importance for the evaluation of disease activity in pulmonary sarcoidosis.

Our modification of a method for the absolute quantification of gallium-67 uptake in lungs with a scintillation camera and computer is described. The uptake of 67Ga in lungs, expressed in percentage of administered radioactivity, was determined by the transmission-emission method. We proved theoretically and experimentally that a 67Ga planar source could be replaced with a 57Co planar source. The performance of lung perfusion scans allows a more accurate delineation of the regions of interest on gallium scans. The method was applied to control subjects (n = 27) and to patients (n = 114) suffering from biopsy-proven pulmonary sarcoidosis (28 with inactive and 86 with active disease). The obtained results were compared with chest X-ray findings, the percentage of lymphocytes in the bronchoalveolar fluid (BAF-ly%), and serum angiotensin-converting enzyme (SACE) values. The method seems suitable for the assessment of disease activity in sarcoidosis. It is more accurate in detecting parenchymal involvement in lung sarcoidosis than the commonly used X-ray criteria. No correlation was found between 67Ga uptake and the BAF-ly% and SACE values.

Bronchoalveolar Lavage Fluid