PubMed Health⌕ Search

Biomedical subjects

P Koutrakis

Publications and source records attributed to P Koutrakis.

At least 19 recordsLinked to original sources

Acute pulmonary and hematological effects of two types of particle surrogates are influenced by their elemental composition.

Several epidemiological studies have consistently demonstrated significant associations between ambient levels of particulate matter and lung injury and cardiovascular events with increased morbidity and mortality. Particle surrogates (PS), such as residual oil fly ash (ROFA), have been widely used in experimental studies aimed at characterizing the mechanisms of particle toxicity. Since PS composition varies depending on its source, studies with different types of PS may provide clues about the relative toxicity of the components generated by high-temperature combustion process. In this work, we have studied the effects of nasal instillation of increasing doses of different PS in mice: saline, carbon, and two types of particle surrogates. PS type A (PSA) was the ROFA collected from the waste incinerator of our university hospital; PS type B (PSB) was collected from the electrostatic precipitator of a large steel company and thus had an elevated metal content. After 24h, we analyzed hematological parameters, fibrinogen, bronchoalveolar lavage, bone marrow, and pulmonary histology. Nasal instillation of the two types of PS-induced leucopenia. PSB elicited a greater elevation of plasma fibrinogen levels. Bone marrow and pulmonary inflammatory changes were more intense for PSA. We concluded that the PS composition modulates acute inflammatory changes more significantly than the mass for these two types of PS.

Air Pollutants↗

Wood-burning appliances and indoor air quality.

Wood heating represents an interesting economic alternative to electrical or heating oil and gas systems. However, many people are concerned about poor indoor air quality in homes equipped with wood-burning appliances. We conducted a study in the Quebec City region (Canada) to verify the extent of indoor air contamination, and to examine the frequency of respiratory symptoms and illnesses among occupants of wood-heated homes. One child attending primary school (median = 8 years old; range = 5-14 years old) and an adult (median = 37 years old; range = 23-52 years old) were recruited in each eligible house. Eligible houses were without known sources of combustion products (smokers, attached garage, oil or gas furnace, gas stove, etc.) except for wood-burning appliance. Out of the 89 houses included in the study, 59 had wood-burning appliances. Formaldehyde, nitrogen dioxide, respirable particles (PM10) and carbon monoxide were measured in a sub-set of 49 houses (41 with a wood-burning appliance and 8 without). The frequency of respiratory symptoms and diseases among participants were documented using a daily symptom diary. Concentrations of contaminants were low in most houses, both with or without a wood-burning appliance. Globally, there was no consistent relationship between the presence of a wood-burning appliance and respiratory morbidity in residents. Nevertheless, residents who mentioned being exposed to fumes emitted by such an appliance reported more respiratory illnesses and symptoms. The presence of animals or molds, and keeping windows closed most of the time in winter were other factors associated with respiratory problems. We conclude that wood burning appears to be a respiratory health risk for occupants if the appliance is not maintained and used properly.

Adolescent↗

Source apportionment of urban particulate aliphatic and polynuclear aromatic hydrocarbons (PAHs) using multivariate methods.

Samples of organic aerosol were collected in Santiago de Chile. An activated-charcoal diffusion denuder was used to strip out organic vapors prior to particle collection. Both polynuclear aromatic hydrocarbons (PAHs) and aliphatic hydrocarbons were determined using gas chromatography/mass spectrometry (GC/MS). Organic particle sources were resolved using both concentration diagnostic ratios and multivariate methods such as hierarchical cluster analysis (HCA) and factor analysis (FA). Four factors were identified based on the loadings of PAHs and n-alkanes and were attributed to the following sources: (1) high-temperature combustion of fuels; (2) fugitive emissions from oil residues; (3) biogenic sources; and (4) unburned fuels. Multilinear regression (MLR) analysis was used to determine emission profiles and contributions of the sources. The reconstructed concentrations of particle phase aliphatic and polynuclear aromatic hydrocarbons were in good agreement (R2 > 0.70) with those measured in Santiago de Chile.

Aerosols↗

Using time- and size-resolved particulate data to quantify indoor penetration and deposition behavior.

Because people spend approximately 85-90% of their time indoors, it is widely recognized that a significant portion of total personal exposures to ambient particles occurs in indoor environments. Although penetration efficiencies and deposition rates regulate indoor exposures to ambient particles, few data exist on the levels or variability of these infiltration parameters, in particular for time- and size-resolved data. To investigate ambient particle infiltration, a comprehensive particle characterization study was conducted in nine nonsmoking homes in the metropolitan Boston area. Continuous indoor and outdoor PM2.5 and size distribution measurements were made in each of the study homes over weeklong periods. Data for nighttime, nonsource periods were used to quantify infiltration factors for PM2.5 as well as for 17 discrete particle size intervals between 0.02 and 10 microns. Infiltration factors for PM2.5 exhibited large intra- and interhome variability, which was attributed to seasonal effects and home dynamics. As expected, minimum infiltration factors were observed for ultrafine and coarse particles. A physical-statistical model was used to estimate size-specific penetration efficiencies and deposition rates for these study homes. Our data show that the penetration efficiency depends on particle size as well as home characteristics. These results provide new insight on the protective role of the building shell in reducing indoor exposures to ambient particles, especially for tighter (e.g., winterized) homes and for particles with diameters greater than 1 micron.

Air Movements↗

Chemical characterization of PM2.5 aerosols in Athens-Greece.

Atmospheric aerosols, PM2.5 were simultaneously collected in the center of Athens and in a semi-urban area of the Athens basin, using the Harvard Impactor (HD) system, from March 1995 to March 1996. 224 24-hr samples were collected. Chemical analysis of the filter samples was performed using ion chromatography (Cl-, SO4(2-); NO3-, Na+, K+, NH4+, Mg2+, Ca2+). In addition aerosol addity was measured using a semi-micro electrode. No significant differences in chemical composition of particles were observed between the two sampling sites. At the city center the annual-average of non-sea-salt sulfate concentration was 85 nmoles m(-3). Also the annual mean values of chloride, ammonium and sodium concentrations were 48, 88 and 71 nmoles m(-3) respectively. Lower concentrations were observed for the rest of the ions. Aerosol acidity was higher at the city center, 18 nmoles m(-3), compared to that observed at the semi-urban site, 14 nmoles m(-3). Species concentrations were examined by season. The mean monthly concentrations of Cr, NO3-, Ca2+ and H+ were higher in the winter. In contrast those of Mg2+ Na+ and K+, were higher in the summer and the spring, respectively. The concentrations of SO4(-2)and NH4+ ions did not exhibit a seasonal pattern. Sulfate and ammonium ions were the predominant ionic species and their ionic ratio ranged between those of ammonium sulfate and letovicite.

Aerosols↗

Source apportionment of PM10 and PM2.5 in five Chilean cities using factor analysis.

Chile is a fast-growing country with important industrial activities near urban areas. In this study, the mass and elemental concentrations of PM10 and PM2.5 were measured in five major Chilean urban areas. Samples of particles with diameter less than 10 microm (PM10) and 2.5 microm (PM2.5) were collected in 1998 in Iquique (northern Chile), Valparaiso, Viña del Mar, Rancagua (central Chile), and Temuco (southern Chile). Both PM10 and PM2.5 annual mean concentrations (PM10: 56.9-77.6 microg/m3; PM2.5: 22.4-42.6 microg/m3) were significantly higher than the corresponding European Union (EU) and U.S. Environmental Protection Agency (EPA) air quality standards. Moreover, the 24-hr PM10 and PM2.5 U.S. standards were exceeded infrequently for some of the cities (Rancagua and Valparaiso). Elements ranging from Mg to Pb were detected in the aerosol samples using X-ray fluorescence (XRF). For each of the five cities, factor analysis (FA) was applied to identify and quantify the sources of PM10 and PM2.5. The agreement between calculated and measured mass and elemental concentrations was excellent in most of the cities. Both natural and anthropogenic sources were resolved for all five cities. Soil and sea were the most important contributors to coarse particles (PM10-PM2.5), whereas their contributions to PM2.5 were negligible. Emissions from Cu smelters and oil refineries (and/or diesel combustion) were identified as important sources of PM2.5, particularly in the industrial cities of Rancagua, Valparaiso, and Viña del Mar. Finally, motor vehicles and wood burning were significant sources of both PM2.5 and PM10 in most of the cities (wood burning was not identified in Iquique).

Agriculture↗

Development and evaluation of an impactor for a PM2.5 speciation sampler.

A conventional impactor for a particle speciation sampler was developed and validated through laboratory and field tests. The speciation sampler consists of the following components: a PM2.5 conventional impactor that removes particles larger than 2.5 microns, an all-glass, coated honeycomb diffusion denuder, and a 47-mm filter pack. The speciation sampler can operate at two different sampling rates: 10 and 16.7 L/min. An experimental characterization of the impactor's performance was conducted. The impactor's collection efficiency was examined as a function of critical design parameters such as Reynolds number, the distance from the nozzle exit to the impaction plate, and the impaction substrate coating method. The bounce of particles larger than the cut point was successfully minimized by using a greased surface as the impaction substrate. Additionally, a series of field intercomparison experiments were conducted at both 10 and 16.7 L/min airflow. PM2.5 mass and SO4(2-) concentrations were measured and compared with the Federal Reference Method (FRM) and found to be in good agreement. Results of the laboratory chamber tests also indicated that the impactor's performance was in good agreement with the FRM.

Air Pollution↗

A pilot investigation of the relative toxicity of indoor and outdoor fine particles: in vitro effects of endotoxin and other particulate properties.

In this study we assessed the in vitro toxicity of 14 paired indoor and outdoor PM(2.5) samples (particulate matter < or =2.5 microm in aerodynamic diameter) collected in 9 Boston-area homes. Samples were collected as part of a large indoor particle characterization study that included the simultaneous measurement of indoor and outdoor PM(2.5), particle size distributions, and compositional data (e.g., elemental/organic carbon, endotoxin, etc.). Bioassays were conducted using rat alveolar macrophages (AMs), and tumor necrosis factor (TNF) was measured to assess particle-induced proinflammatory responses. Additional experiments were also conducted in which AMs were primed with lipopolysaccharides (LPS) to simulate preexisting pulmonary inflammation such as that which might exist in sick and elderly individuals. Significant TNF production above that of negative controls was observed for AMs exposed to either indoor or outdoor PM(2.5). TNF releases were further amplified for primed AMs, suggesting that preexisting inflammation can potentially exacerbate the toxicity of not only outdoor PM(2.5) (as shown by previous studies) but also indoor PM(2.5). In addition, indoor particle TNF production was found to be significantly higher than outdoor particle TNF production in unprimed AMs, both before and after normalization for endotoxin concentrations. Our results suggest that indoor-generated particles may be more bioactive than ambient particles. Endotoxin was demonstrated to mediate proinflammatory responses for both indoor and outdoor PM(2.5), but study findings suggest the presence of other proinflammatory components of fine particles, particularly for indoor-generated particles. Given these study findings and the fact that people spend 85-90% of their time indoors, future studies are needed to address the toxicity of indoor particles.

Air Pollutants↗

Laboratory and field evaluation of measurement methods for one-hour exposures to O3, PM2.5, and CO.

While researchers have linked acute (less than 12-hr) ambient O3, PM2.5, and CO concentrations to a variety of adverse health effects, few studies have characterized short-term exposures to these air pollutants, in part due to the lack of sensitive, accurate, and precise sampling technologies. In this paper, we present results from the laboratory and field evaluation of several new (or modified) samplers used in the "roll-around" system (RAS), which was developed to measure 1-hr O3, PM2.5, and CO exposures simultaneously. All the field evaluation data were collected during two sampling seasons: the summer of 1998 and the winter of 1999. To measure 1-hr O3 exposures, a new active O3 sampler was developed that uses two nitrite-coated filters to measure O3 concentrations. Laboratory chamber tests found that the active O3 sampler performed extremely well, with a collection efficiency of 0.96 that did not vary with temperature or relative humidity (RH). In field collocation comparisons with a reference UV photometric monitor, the active O3 sampler had an effective collection efficiency ranging between 0.92 and 0.96 and a precision for 1-hr measurements ranging between 4 and 6 parts per billion (ppb). The limits of detection (LOD) of this method were 9 ppb-hr for the chamber tests and approximtely 16 ppb-hr for the field comparison tests. PM2.5 and CO concentrations were measured using modified continuous monitors--the DustTrak and the Langan, respectively. A size-selective inlet and a Nafion dryer were placed upstream of the DustTrak inlet to remove particles with aerodynamic diameters greater than 2.5 microm and to dry particles prior to the measurements, respectively. During the field validation tests, the DustTrak consistently reported higher PM2.5 concentrations than those obtained by the collocated 12-hr PM2.5 PEM samples, by approximately a factor of 2. After the DustTrak response was corrected (correction factor of 2.07 in the summer and 2.02 in the winter), measurements obtained using these methods agreed well with R2 values of 0.87 in the summer and 0.81 in the winter. The results showed that the DustTrak can be used along with integrated measurements to measure the temporal and spatial variation in PM2.5 exposures. Finally, during the field validation tests, CO concentrations measured using the Langan were strongly correlated with those obtained using the reference method when the CO levels were above the LOD of the instrument [approximately 1 part per million (ppm)].

Carbon Monoxide↗

Guidance for the performance evaluation of three-dimensional air quality modeling systems for particulate matter and visibility.

Guidance for the performance evaluation of three-dimensional air quality modeling systems for particulate matter and visibility is presented. Four levels are considered: operational, diagnostic, mechanistic, and probabilistic evaluations. First, a comprehensive model evaluation should be conducted in at least two distinct geographical locations and for several meteorological episodes. Next, streamlined evaluations can be conducted for other similar applications if the comprehensive evaluation is deemed satisfactory. In all cases, the operational evaluation alone is insufficient, and some diagnostic evaluation must always be carried out. Recommendations are provided for designing field measurement programs that can provide the data needed for such model performance evaluations.

Air Pollution↗

Concentration and composition of atmospheric aerosols from the 1995 SEAVS experiment and a review of the closure between chemical and gravimetric measurements.

We summarize the results from the various measurements and the inter-sampler comparisons from Southeastern Aerosol and Visibility Study (SEAVS), a study with one of its objectives to test for closure among chemical, gravimetric and optical measurements of atmospheric aerosol particles. Sulfate and organics are the dominant components of the SEAVS fine particles (nominally, particles with aerodynamic diameter < or = 2.5 microns) but between 28 and 42% (range over various samplers) of the gravimetrically measured total fine particle concentration is unidentified by the chemical measurements. Estimates of water associated with inorganic components and measurement imprecision do not totally explain the observed difference between gravimetric and chemical measurements. We examine the theoretical and empirical basis for assumptions commonly made in the published literature to extrapolate total fine particle concentration on the basis of chemical measurements of ions, carbon and elements. We then explore the more general question of closure using the SEAVS data as well as data from other, similar studies reported in the literature. In so combining the SEAVS measurements with other similar studies, we find a strong association between organic carbon and the unidentified component, that is, the fraction of the total fine particle concentration not identified by chemical measurements. We offer several tenable hypotheses for the relationship between the organic and unidentified components that deserve to be tested in future work. Specifically, we hypothesize that (1) errors in the sampling and analysis of organic carbon; (2) estimates of organic mass from measurements of organic carbon; and/or (3) water absorption by organics may all contribute to the observed relationship.

Aerosols↗

Hourly personal exposures to fine particles and gaseous pollutants--results from Baltimore, Maryland.

A study to characterize 1-hr multi-pollutant exposures was performed in Baltimore, MD, during the summer of 1998 and the winter of 1999, and was conducted over a 15-day period in each of the two seasons. Personal exposures were measured by a trained field technician, who wore a newly developed Roll-Around System (RAS) to measure 1-hr PM2.5 and gaseous (CO, O3, NO2, SO2, volatile organic compounds [VOCs]) exposures. One-hour O3, NO2, and SO2 personal exposures were measured using samplers developed in our laboratory, while short-term PM2.5, CO, and VOCs exposures were measured using currently available monitors. All 1-hr multi-pollutant exposures were measured while the technician performed pre-determined activities, beginning at 7:00 a.m. and ending at 7:00 p.m. of the same day. Activities were scripted to simulate activities performed by older adults (65+ years of age). Corresponding 1-hr ambient pollutant concentrations were obtained from federal or state monitoring networks. In this paper, we discuss the results from our study and present our descriptive analysis of the 1-hr personal particulate and gaseous exposure data. Personal PM2.5, O3, CO, and VOCs exposures showed substantial variability over the 12-hr sampling periods. Multiple pairwise comparison tests showed that 1-hr personal O3 exposures were significantly lower in indoor microenvironments as compared with outdoor microenvironments. One-hour personal CO exposures measured in vehicles were significantly higher than those measured in other microenvironments. The associations between 1-hr personal exposures and corresponding ambient concentrations differed by pollutant and by microenvironment. For example, the correlation between personal PM2.5 exposures and ambient concentrations was lowest (rs = 0.36, p < 0.05) in the winter for indoor non-residential microenvironments, and was highest (rs = 0.90, p < 0.05) in the winter for in-vehicle microenvironments. For O3, the correlation between personal exposures and ambient levels was weakest in the winter for residential microenvironments (rs = 0.05, p > 0.05), and was strongest in the summer for outdoor near-roadway microenvironments (rs = 0.91, p < 0.05).

Activities of Daily Living↗

Method comparisons for particulate nitrate, elemental carbon, and PM2.5 mass in seven U.S. cities.

Methods that measure PM2.5 mass, total particulate NO3-, and elemental carbon (EC) were evaluated in seven U.S. cities from 1997 to 1999. Sampling was performed in Bakersfield, CA; Boston, MA; Chicago, IL; Dallas, TX; Philadelphia, PA; Phoenix, AZ; and Riverside, CA. Evaluating and validating methods that measure the components of fine mass are important to the effort of establishing a speciation-monitoring network. The Harvard Impactor (HI), which measures fine particle mass, showed excellent agreement (r2 = 0.99) with the PM2.5 Federal Reference Method (FRM) for 81 24-hr samples in Riverside and Bakersfield. The HI also showed good precision (4.8%) for 243 24-hr collocated samples over eight studies. The Aethalometer was employed in six of the sampling locations to measure black carbon (BC). These values were compared to EC as measured from a quartz filter using thermal analysis. For the six cities combined, the two methods were highly correlated (r2 = 0.94; 187 24-hr samples); however, the BC values were approximately 24% less than the EC measurements consistently across all six cites. This compares well to results observed for EC/BC measurements observed in other semi-urban areas. Particulate NO3- was measured using the Harvard-EPA Annular Denuder System (HEADS). This was compared to the NO3- measured from the HI Teflon (DuPont) filter to assess NO3- artifacts. Significant NO3- losses (approximately 50% of total NO3-) were found in Riverside, Philadelphia, and Boston, while minimal artifacts were observed in the other sites. Two types of HEADS configurations were employed in five cities. One system used a Na2CO3-coated glass fiber filter, and the other type used a nylon filter to collect volatilized NO3- from the Teflon filter. The HEADS with the Na2CO3-coated filter consistently underestimated the total particulate NO3- by approximately 20% compared to the nylon HEADS.

Air Pollution↗

Characterization of indoor particle sources using continuous mass and size monitors.

A comprehensive indoor particle characterization study was conducted in nine Boston-area homes in 1998 in order to characterize sources of PM in indoor environments. State-of-the-art sampling methodologies were used to obtain continuous PM2.5 concentration and size distribution particulate data for both indoor and outdoor air. Study homes, five of which were sampled during two seasons, were monitored over week-long periods. Among other data collected during the extensive monitoring efforts were 24-hr elemental/organic carbon (EC/OC) particulate data as well as semi-continuous air exchange rates and time-activity information. This rich data set shows that indoor particle events tend to be brief, intermittent, and highly variable, thus requiring the use of continuous instrumentation for their characterization. In addition to dramatically increasing indoor PM2.5 concentrations, these data demonstrate that indoor particle events can significantly alter the size distribution and composition of indoor particles. Source event data demonstrate that the impacts of indoor activities are especially pronounced in the ultrafine (da < or = 0.1 micron) and coarse (2.5 < or = da < or = 10 microns) modes. Among the sources of ultrafine particles characterized in this study are indoor ozone/terpene reactions. Furthermore, EC/OC data suggest that organic carbon is a major constituent of particles emitted during indoor source events. Whether exposures to indoor-generated particles, particularly from large short-term peak events, may be associated with adverse health effects will become clearer when biological mechanisms are better known.

Air Pollution, Indoor↗

Assessing the relationship between personal particulate and gaseous exposures of senior citizens living in Baltimore, MD.

We conducted a multi-pollutant exposure study in Baltimore, MD, in which 15 non-smoking older adult subjects (> 64 years old) wore a multi-pollutant sampler for 12 days during the summer of 1998 and the winter of 1999. The sampler measured simultaneous 24-hr integrated personal exposures to PM2.5, PM10, SO4(2-), O3, NO2, SO2, and exhaust-related VOCs. Results of this study showed that longitudinal associations between ambient PM2.5 concentrations and corresponding personal exposures tended to be high in the summer (median Spearman's r = 0.74) and low in the winter (median Spearman's r = 0.25). Indoor ventilation was an important determinant of personal PM2.5 exposures and resulting personal-ambient associations. Associations between personal PM2.5 exposures and corresponding ambient concentrations were strongest for well-ventilated indoor environments and decreased with ventilation. This decrease was attributed to the increasing influence of indoor PM2.5 sources. Evidence for this was provided by SO4(2-) measurements, which can be thought of as a tracer for ambient PM2.5. For SO4(2-), personal-ambient associations were strong even in poorly ventilated indoor environments, suggesting that personal exposures to PM2.5 of ambient origin are strongly associated with corresponding ambient concentrations. The results also indicated that the contribution of indoor PM2.5 sources to personal PM2.5 exposures was lowest when individuals spent the majority of their time in well-ventilated indoor environments. Results also indicate that the potential for confounding by PM2.5 co-pollutants is limited, despite significant correlations among ambient pollutant concentrations. In contrast to ambient concentrations, PM2.5 exposures were not significantly correlated with personal exposures to PM2.5-10, PM2.5 of non-ambient origin, O3, NO2, and SO2. Since a confounder must be associated with the exposure of interest, these results provide evidence that the effects observed in the PM2.5 epidemiologic studies are unlikely to be due to confounding by the PM2.5 co-pollutants measured in this study.

Aged↗

Inhaled concentrated ambient particles are associated with hematologic and bronchoalveolar lavage changes in canines.

Pulmonary inflammatory and hematologic responses of canines were studied after exposure to concentrated ambient particles (CAPs) using the Harvard ambient particle concentrator (HAPC). For pulmonary inflammatory studies, normal dogs were exposed in pairs to either CAPs or filtered air (paired studies) for 6 hr/day on 3 consecutive days. For hematologic studies, dogs were exposed for 6 hr/day for 3 consecutive days with one receiving CAPs while the other was simultaneously exposed to filtered air; crossover of exposure took place the following week (crossover studies). Physicochemical characterization of CAPs exposure samples included measurements of particle mass, size distribution, and composition. No statistical differences in biologic responses were found when all CAPs and all sham exposures were compared. However, the variability in biologic response was considerably higher with CAPs exposure. Subsequent exploratory graphical analyses and mixed linear regression analyses suggested associations between CAPs constituents and biologic responses. Factor analysis was applied to the compositional data from paired and crossover experiments to determine elements consistently associated with each other in CAPs samples. In paired experiments, four factors were identified; in crossover studies, a total of six factors were observed. Bronchoalveolar lavage (BAL) and hematologic data were regressed on the factor scores. Increased BAL neutrophil percentage, total peripheral white blood cell (WBC) counts, circulating neutrophils, and circulating lymphocytes were associated with increases in the aluminum/silicon factor. Increased circulating neutrophils and increased BAL macrophages were associated with the vanadium/nickel factor. Increased BAL neutrophils were associated with the bromine/lead factor when only the compositional data from the third day of CAPs exposure were used. Significant decreases in red blood cell counts and hemoglobin levels were correlated with the sulfur factor. BAL or hematologic parameters were not associated with increases in total CAPs mass concentration. These data suggest that CAPs inhalation is associated with subtle alterations in pulmonary and systemic cell profiles, and specific components of CAPs may be responsible for these biologic responses.

Air Pollutants↗

Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.

An intensive particle monitoring study was conducted in homes in the Boston, Massachusetts, area during the winter and summer of 1996 in an effort to characterize sources of indoor particles. As part of this study, continuous particle size and mass concentration data were collected in four single-family homes, with each home monitored for one or two 6-day periods. Additionally, housing activity and air exchange rate data were collected. Cooking, cleaning, and the movement of people were identified as the most important indoor particle sources in these homes. These sources contributed significantly both to indoor concentrations (indoor-outdoor ratios varied between 2 and 33) and to altered indoor particle size distributions. Cooking, including broiling/baking, toasting, and barbecuing contributed primarily to particulate matter with physical diameters between 0.02 and 0.5 microm [PM((0.02-0.5))], with volume median diameters of between 0.13 and 0.25 microm. Sources of particulate matter with aerodynamic diameters between 0.7 and 10 microm [PM((0.7-10))] included sautéing, cleaning (vacuuming, dusting, and sweeping), and movement of people, with volume median diameters of between 3 and 4.3 microm. Frying was associated with particles from both PM((0.02-0.5)) and PM((0.7-10)). Air exchange rates ranged between 0.12 and 24.3 exchanges/hr and had significant impact on indoor particle levels and size distributions. Low air exchange rates (< 1 exchange/hr) resulted in longer air residence times and more time for particle concentrations from indoor sources to increase. When air exchange rates were higher (> 1 exchange/hr), the impact of indoor sources was less pronounced, as indoor particle concentrations tracked outdoor levels more closely.

Activities of Daily Living↗

Mechanisms of morbidity and mortality from exposure to ambient air particles.

The studies reported here assessed pathophysiologic mechanisms that result from exposure to concentrated ambient particles (CAPs) in animals with and without cardiopulmonary compromise. These studies were carried out to determine the biologic plausibility of epidemiologic observations of increases in particulate air pollution associated with increases in human morbidity and mortality. Dogs were exposed two at a time to CAPs or filtered air via tracheostomy for six hours per day on three consecutive days. The electrocardiogram (ECG) and breathing pattern were recorded continuously, and indicators of inflammation were also assessed. In one experimental design, normal dogs were exposed in pairs to CAPs and subsequently to filtered air or to filtered air and subsequently CAPs (the double CAPs/double sham design). Comparisons were made between the CAPs measurements and each dog's own sham responses. In another design, one dog was exposed to CAPs while the chambermate received a sham exposure; these experiments were followed by crossover of the protocol the subsequent week (the crossover design). Comparisons were made between the CAPs exposure and both the chambermate's sham and each dog's own sham responses. The crossover experiments were conducted in normal animals and in animals who had undergone balloon occlusion of the left anterior descending (LAD) coronary artery to induce myocardial compromise. The effects of CAPs in animals with induced chronic bronchitis were part of the original specific aims; because these studies were not fully pursued, the results are presented only in Appendix A. In normal dogs, analyses of all double CAPs and crossover studies revealed low frequency (LF) and high frequency (HF) powers for heart rate variability (HRV) that were significantly higher for CAPs exposure compared to sham exposure. Variation in day-to-day exposure concentrations, aerosol composition, and pathophysiologic responses were also found. The crossover design, continuous measures of aerosol mass, and biologic responses were incorporated in the development of a statistical model that allowed isolation of changes associated with CAPs from changes due to animal variations. Comparison of individual exposures with this model revealed a range from no response in any measured parameter to statistically significant changes in cardiac autonomic balance, pulmonary air flow, and breathing pattern. On days in which dogs showed statistically significant changes in responses, the findings were consistent in both cardiac and respiratory parameters. Days associated with significant increases in LF and HF HRV, LF/ HF HRV ratio, and heart rate standard deviation (HR SD) were also associated with decreases in average heart rate. These same days had decreases in respiratory frequency, tidal volume, minute volume, and peak flows with corresponding increases in respiratory cycle times and enhanced pause (Pauenh), a measure of bronchoconstriction. These cardiac and respiratory changes suggest an effect mediated via both the sympathetic nervous system and the vagus nerve. Alternatively, days associated with increased heart rate had decreases in the HR SD; decreases or no change in HF and LF HRV; increases in respiratory flows and volumes; and decreases in breathing cycle times, all suggesting only sympathetic nervous system mediation. When all data from the crossover design experiments were assessed with this model, the heart rate and respiratory rate were significantly decreased in relation to both cumulative and actual exposure and the LF HRV, LF/HF HRV ratio, HR SD, and all other respiratory parameters were significantly increased (p < 0.0001 for all). When cardiac data were grouped by days in which the air mass trajectory came from the north or northwest (versus west, south, east, or northeast), significant increases in HR SD and HF HRV and significant decreases in average heart rate were associated with the northwest trajectory. (ABSTRACT TRUNCATED)

Air Pollutants↗