Diffraction patterns of artificial two-dimensional crystals synthesized in situ in an environmental scanning transmission electron microscope.

In this study, we demonstrated the use of electron-beam-induced deposition for synthesis of artificial two-dimensional crystals with an in situ scanning transmission electron microscope. The structures were deposited from W(CO)6 in an environmental scanning transmission electron microscope on a 30-nm-thick Si3N4 substrate. We present clear electron beam diffraction patterns taken from those structures. The distance between the diffraction peaks corresponded to the dot spacing in the self-made surface crystal. We propose using these arrays of dots as anchor points for making artificial crystals for diffraction analysis of weakly scattering or beam-sensitive molecules such as proteins.

Journal Article↗

Low-energy foil aberration corrector.

A spherical and chromatic aberration corrector for electron microscopes is proposed, consisting of a thin foil sandwiched between two apertures. The electrons are retarded at the foil to almost zero energy, so that they can travel ballistically through the foil. It is shown that such a low-voltage corrector has a negative spherical aberration for not too large distances between aperture and foil, as well as a negative chromatic aberration. For various distances the third- and fifth-order spherical aberration coefficients and the first- and second-order chromatic aberration coefficients are calculated using ray tracing. Provided that the foils have sufficient electron transmission the corrector is able to correct the third-order spherical aberration and the first-order chromatic aberration of a typical low-voltage scanning electron microscope. Preliminary results show that the fifth-order spherical aberration and the second-order chromatic aberration can be kept sufficiently low.

Journal Article↗

Construction and characterization of the fringe field monochromator for a field emission gun

Although some microscopes have shown stabilities sufficient to attain below 0.1 eV spectral resolution in high-resolution electron energy loss spectroscopy, the intrinsic energy width of the high brightness source (0.3-0.6 eV) has been limiting the resolution. To lower the energy width of the source to 50 meV without unnecessary loss of brightness, a monochromator has been designed consisting of a short (4 mm) fringe field Wien filter and a 150 nm energy selection slit (nanoslit) both to be incorporated in the gun area of the microscope. A prototype has been built and tested in an ultra-high-vacuum setup (10(-9) mbar). The monochromator, operating on a Schottky field emission gun, showed stable and reproducible operation. The nanoslits did not contaminate and the structure remained stable. By measuring the current through the slit structure a direct image of the beam in the monochromator could be attained and the monochromator could be aligned without the use of a microscope. Good dispersed imaging conditions were found indicating an ultimate resolution of 55 meV. A Mark II fringe field monochromator (FFM) was designed and constructed compatible with the cold tungsten field emitter of the VG scanning transmission microscope. The monochromator was incorporated in the gun area of the microscope at IBM T.J. Watson research center, New York. The monochromator was aligned on 100 kV and the energy distribution measured using the monochromator displayed a below 50 meV filtering capability. The retarding Wien filter spectrometer was used to show a 61 meV EELS system resolution. The FFM is shown to be a monochromator which can be aligned without the use of the electron microscope. This makes it directly applicable for scanning transmission microscopy and low-voltage scanning electron microscopy, where it can lower the resolution loss which is caused by chromatic blur of the spot.

Journal Article↗

The influence of objective lens aberrations in energy-loss spectrometry.

The conditions under which the energy resolution and collection efficiency in electron energy-loss spectrometry are limited by the spherical and chromatic aberrations of the objective lens have been studied. It is shown that, for the optimum settings of the pre-spectrometer optics, the energy resolution will be of the same order in diffraction mode as it is in magnification mode. The influence of the aberrations on the practice of energy-loss spectroscopy is discussed, and it is demonstrated that the chromatic aberration can act as a broadband filter for energy-loss electrons.

Electron Probe Microanalysis↗

Detection of X-rays and electron energy loss events in time coincidence.

Experiments are described in which characteristic X-rays are detected in coincidence with the electron energy losses that are responsible for these X-rays. The possibility to use this technique for improving the detection limits of microanalysis is evaluated. It is concluded that, because of the occurrence of false coincidences, better than the state-of-the-art instrumentation will be required for most practical applications.

Calcium↗

Shot noise in electron-beam lithography and line-width measurements.

Electron-beam lithography is used extensively in nanoscience and technology for making masks for the semiconductor industry and, on a limited scale, for maskless lithography: that is, writing the patterns directly on the chip. We expect the latter application to extend in the years to come. Control of the dimensions of the written structures is essential in the semiconductor industry. For 45 nm generation, which is presently under development and should reach production at the end of the decade, the required control over the line width is between 1.5 and 5 nm, depending on the application. One of the factors of influence on the line-width control is the statistics in the number of electrons illuminating the resist. This effect gives line edge roughness, or in other words a lack of control over the local position of a resist edge. This has long been recognized and often discussed. Recently, we developed an analytic model for the line edge position variation, which we shall illustrate and expand in this paper. The model, supported by Monte Carlo simulations, demonstrates that the line-width variation is inversely proportional to the dose used for the illumination of the resist. This makes it impossible to increase the lithography throughput by developing ultrasensitive resists. For 45 nm features written with a typical resolution of 30 nm, a 30 microC/cm2 resist gives 3 nm line-width variation over line segments of 45 nm long. The line width is usually measured in an adapted critical dimension scanning electron microscope (CD-SEM). This measurement needs to be more precise than the result of the lithography step, so the requirements are typically sub-nm. Apart from all the problems to avoid systematic errors, this measurement also suffers from statistical variations, resulting from the finite number of electrons used for the measurement. In this paper we shall derive an estimate for that variation with a similar model as used for the shot noise effect in the lithography step. One of the conclusions is that for the most precise measurements of the line width it is not advisable to tune the CD-SEM for the best resolution. It is better to allow a larger probe size of the electron beam because that can be accompanied by a much larger current and thus a decrease in the noise level.

Journal Article↗

Aberration model of a multibeam scanning microscope for electron beam-induced deposition.

A multibeam electron beam-induced deposition (EBID) system is presented, which aims at the fabrication of sub-10 nm structures with EBID. This system consists of a multibeam source (MBS) module, delivering 100 virtual sources and a standard scanning electron microscope (SEM) column to image the 100 sources onto a wafer. In the proposed concept, beamlets are traveling off-axis through the projection lenses, introducing off-axis aberrations. An analytical description of the projection lens aberrations is derived and the system is optimized by tuning a field lens, which only affects the direction of the beamlets as they enter the projection system. It is found that this lens must be excited such that all beamlets go through the center of the last projection lens. This is an important design rule for the total system.

Journal Article↗

Resolution limit for electron beam-induced deposition on thick substrates.

Recently, the fabrication resolution in electron beam-induced deposition (EBID) has improved significantly. Dots with an average diameter of 1 nm have been made. These results were all obtained in transmission electron microscopes on thin samples. As one may think that such resolution can be achieved on thin samples only, it is the objective of this paper to show that this should also be possible on thick samples. For that purpose we use Monte Carlo simulations of the electron-sample interaction and determine the surface area where secondary electrons are emitted. Assuming that these electrons cause the deposition in EBID, a comparison can be made between deposition on a thin and a thick sample. The Monte Carlo code we developed will be described and applied to the deposition induced by a 200 keV primary electron beam on an ultra-thin (10 nm) and a bulk-like (1,000 nm) Cu sample. Near the point of incidence of the primary beam, the deposit size is independent of the substrate thickness, such that a 1-nm resolution should be possible to achieve on a thick substrate as well. Thicker substrates only affect the tails of the deposit distribution which contain more mass than thin substrate deposit tails.

Journal Article↗