PubMed Health⌕ Search

Biomedical subjects

P Kuppusamy

Publications and source records attributed to P Kuppusamy.

At least 19 recordsLinked to original sources

Hypoxic constriction and reactive oxygen species in porcine distal pulmonary arteries.

To determine whether reactive oxygen species (ROS) play an essential role in hypoxic pulmonary vasoconstriction (HPV) and the cellular locus of ROS production and action during HPV, we measured internal diameter (ID) at constant transmural pressure, lucigenin-derived chemiluminescence (LDCL), and electron paramagnetic resonance (EPR) spin adduct spectra in small distal porcine pulmonary arteries, and dichlorofluorescein (DCF) fluorescence in myocytes isolated from these arteries. Hypoxia (4% O2) decreased ID, increased DCF fluorescence, tended to increase LDCL, and in some preparations produced EPR spectra consistent with hydroxyl and alkyl radicals. Superoxide dismutase (SOD, 150 U/ml) or SOD + catalase (CAT, 200 U/ml) did not alter ID during normoxia but reduced or abolished the constriction induced by hypoxia. SOD also blocked HPV in endothelium-denuded arteries after restoration of the response by exposure to 10-10 M endothelin-1. Confocal fluorescence microscopy demonstrated that labeled SOD and CAT entered pulmonary arterial myocytes. SOD, SOD + CAT, and CAT blocked the increase in DCF fluorescence induced by hypoxia, but SOD + CAT and CAT also caused a stable increase in fluorescence during normoxia, suggesting that CAT diminished efflux of DCF from cells or oxidized the dye directly. We conclude that HPV required increased concentrations of ROS produced by and acting on pulmonary arterial smooth muscle rather than endothelium.

Acetylcholine↗

Feasibility and assessment of non-invasive in vivo redox status using electron paramagnetic resonance imaging.

PURPOSE: To test the feasibility of electron paramagnetic resonance imaging (EPRI) to provide non-invasive images of tissue redox status using redox-sensitive paramagnetic contrast agents. MATERIAL AND METHODS: Nitroxide free radicals were used as paramagnetic agents and a custom-built 300 MHz EPR spectrometer/imager was used for all studies. A phantom was constructed consisting of four tubes containing equal concentrations of a nitroxide. Varying concentrations of hypoxanthine/xanthine oxidase were added to each tube and reduction of the nitroxide was monitored by EPR as a function of time. Tumor-bearing mice were intravenously infused with a nitroxide and the corresponding reduction rate was monitored on a pixel-by-pixel basis using 2D EPR of the tumor-bearing leg and normal leg serving as control. For animal studies, nitroxides were injected intravenously (1.25 mmol/kg) and EPR projections were collected every 3 min after injection using a magnetic field gradient of 2.5 G/cm. The reduction rates of signal intensity on a pixel-by-pixel basis were calculated and plotted as a redox map. Redox maps were also collected from the mice treated with diethylmaleate (DEM), which depletes tissue thiols and alters the global redox status. RESULTS: Redox maps obtained from the phantoms were in agreement with the intensity change in each of the tubes where the signals were decreasing as a function of the enzymatic activity, validating the ability of EPRI to accurately access changes in nitroxide reduction. Redox imaging capability of EPR was next evaluated in vivo. EPR images of the nitroxide distribution and reduction rates in tumor-bearing leg of mice exhibited more heterogeneity than in the normal tissue. Reduction rates were found to be significantly decreased in tumors of mice treated with DEM, consistent with the depletion of thiols and the consequent alteration of the redox status. CONCLUSION: Using redox-sensitive paramagnetic contrast agents, EPRI can non-invasively discriminate redox status differences between normal tissue and tumors.

Animals↗

Whole body detection and imaging of nitric oxide generation in mice following cardiopulmonary arrest: detection of intrinsic nitrosoheme complexes.

Ischemic tissues generate nitric oxide (NO) by direct reduction of tissue nitrite under the acidic conditions that occur during ischemia. In view of the important implications of this enzyme-independent mechanism of NO generation on the pathogenesis and treatment of tissue injury, the NO formation in mice subjected to cardiopulmonary arrest was measured and imaged. Real-time measurement of NO generation was performed by detection of naturally generated NO-heme complexes in tissues using L-band electron paramagnetic resonance (EPR) spectroscopy. To distinguish NO generated from nitrite, animals were labeled with isotopically enriched (15)N-nitrite. Mice were infused with nitrite (70 mg/kg, intravenous), cardiopulmonary arrest induced by an overdose of phenobarbital, and transferred to the EPR resonator. Measurements of NO generation were performed on the intact animal at the levels of the head, thorax, and abdomen. At the end of 3 hr, major organs were isolated and analyzed for their NO signal. The NO complexes were found to have maximum levels in lung, heart, and liver. Three-dimensional spatial mapping of the NO complex in the intact animal subjected to cardiopulmonary arrest was performed using EPR imaging techniques. The images also confirmed the maximum formation in the lungs, heart, and liver. The present data reveal that mice subjected to cardiopulmonary arrest generate large amounts of NO, which is nitrite mediated. The observed signal was largely due to heme-bound NO, which accounted for the high concentrations found in these organs. This increased NO formation during cardiopulmonary arrest could contribute to the difficulty of resuscitation after long periods of arrest. Magn Reson Med 45:700-707, 2001.

Animals↗

EPR oxygen mapping (EPROM) of engineered cartilage grown in a hollow-fiber bioreactor.

A novel electron paramagnetic resonance (EPR)-based oxygen mapping procedure (EPROM) is applied to cartilage grown in a single-, hollow-fiber bioreactor (HFBR) system. Chondrocytes harvested from the sterna of 17-day-old chick embryos were inoculated into an HFBR and produced hyaline cartilage over a period of 4 weeks. Tissue oxygen maps were generated according to the EPROM technique (Velan et al., Magn Reson Med 2000;43:804-809) by making use of the line-broadening effects of oxygen on the signal generated from nitroxide spin probes. In addition, the effect on oxygen consumption of the addition of cyanide to the tissue was investigated. Cyanide is a potent inhibitor of oxidative phosphorylation, and accordingly, given the constant provision of oxygen to the tissue, it would be expected to increase oxygen levels within the HFBR. The EPROM measurements showed a significant increase in oxygen concentration in the cartilage after the addition of cyanide. In contrast to other methods for studying oxygen in cartilage, EPROM can provide direct, noninvasive visualization of local concentrations in three dimensions.

Animals↗

In vivo EPR imaging of the distribution and metabolism of nitroxide radicals in human skin.

While altered cellular free radical and redox metabolism are critical factors in many human diseases, it has not been previously possible to both measure and image these processes in humans. The development and application of electron paramagnetic resonance instrumentation capable of in vivo spectroscopy and imaging of free radicals in human skin are reported. The instrumentation uses a specially designed topical resonator and a 2.2-GHz microwave bridge. Noninvasive measurements of the distribution and metabolism of the topically applied nitroxide, (15)N-perdeuterated tempone (100 mM), in forearm skin were performed. A single broad peak due to the concentrated label at the skin surface was initially observed, followed by a sharp doublet from the diluted label that permeated the skin. The penetration of the label into the skin and its metabolic clearance were modeled using kinetic equations. It was observed that the penetration process from the skin surface into the dermis and subcutaneous regions, as well as its clearance from these regions, could be described by single exponential functions. Phantom imaging experiments using the nitroxide showed that a spatial resolution of up to 50 microm could be achieved. The skin imaging measurements showed two bands in the distribution of the label along the skin depth. The first band appeared in the outer 400 microm of the skin, the epidermis region, whereas the second band was centered at a depth of 1000 microm in the subcutaneous region with a thickness about 400 microm. These two bands decayed and merged into a single band with time. The results are important in the understanding of the permeability and metabolism of free radicals in human skin.

Algorithms↗

Development of a resonator with automatic tuning and coupling capability to minimize sample motion noise for in vivo EPR spectroscopy.

EPR spectroscopy has been applied to measure free radicals in vivo; however, respiratory, cardiac, and other movements of living animals are a major source of noise and spectral distortion. Sample motions result in changes in resonator frequency, Q, and coupling. These instabilities limit the applications that can be performed and the quality of data that can be obtained. Therefore, it is of great importance to develop resonators with automatic tuning and automatic coupling capability. We report the development of automatic tuning and automatic coupling provisions for a 750-MHz transversely oriented electric field reentrant resonator using two electronically tunable high Q hyperabrupt varactor diodes and feedback loops. In both moving phantoms and living mice, these automatic coupling control and automatic tuning control provisions resulted in an 8- to 10-fold increase in signal-to-noise ratio.

Animals↗

A bridged loop-gap S-band surface resonator for topical EPR spectroscopy.

The design and structure of a bridged loop-gap surface resonator developed for topical EPR spectroscopy and imaging of the distribution and metabolism of spin labels in in vivo skin is reported. The resonator is a one-loop, one-gap bridged structure. A pivoting single loop-coupling coil was used to couple the microwave power to the loop-gap resonant structure. A symmetric coupling circuit was used to achieve better shielding and minimize radiation. The frequency of the resonator can be easily adjusted by trimming the area of the capacitive foil bridge, which overlaps the gap in the cylindrical loop. The working frequency set was 2.2 GHz and the unloaded Q was 720. The B1 field of this resonator was measured and spatially mapped by three-dimensional EPR imaging. The resonator is well suited to topical measurements of large biological subjects and is readily applicable for in vivo measurements of free radicals in human skin.

Electromagnetic Fields↗

Magnetic resonance imaging for in vivo assessment of tissue oxygen concentration.

Magnetic resonance imaging (MRI) provides high-resolution morphological images useful in diagnostic radiology to differentiate normal from abnormal/pathological states. More recently, emerging developments in MRI seek to add a functional/physiological dimension to the anatomic images to provide better understanding of the physiology of pathological conditions. Three MRI methods offer the promise of providing important physiologic information, such as oxygen status and redox capability of tissues, and these are discussed in the context of their potential usefulness to radiation oncology. The techniques include blood oxygen level-dependent (BOLD) MRI, Overhauser enhanced MRI (OMRI), and electron paramagnetic resonance imaging (EPRI). BOLD MRI provides information of tumor oxygen status by using the differences in MRI images from tumors obtained when breathing air or carbogen. Deoxyhemoglobin serves as an endogenous BOLD MRI contrast agent. OMRI utilizes the enhancement of proton MRI images by a nontoxic free radical contrast agent. The advantages of this technique are the very low magnetic fields used and its capability to provide quantitative information of tissue oxygen concentration. EPRI also uses free radical contrast agents and can provide redox and oxygen status differences between tumor and normal tissues. Some of the contrast agents used in EPRI have been identified as radiation protectors. The images obtained from each of the technologies may ultimately be used to overlay their respective views (containing spatial tissue physiology information) onto detailed anatomic maps.

Humans↗

Electron paramagnetic resonance for small animal imaging applications.

Magnetic resonance imaging (MRI) provides high-resolution morphological images useful in diagnostic radiology to differentiate between normal and abnormal/pathological states in tissues. More recently, emerging developments in MRI have added a functional/physiological dimension to anatomical images. Electron paramagnetic resonance (EPR), a magnetic resonance technique similar to nuclear magnetic resonance, detects paramagnetic species such as free radicals. Like MRI, EPR can be implemented as an imaging technique for small animals and potentially human applications. Because of the low abundance of naturally occurring paramagnetic species, exogenous paramagnetic species are needed for in vivo EPR imaging (EPRI). The image data from EPRI contain both spatial distribution of paramagnetic species and spectral information. Hence, spatially encoded functional information such as tissue oxygen status and redox status can be extracted and coregistered with the spatial distribution of the spin probe, to the anatomy, or both by suitable means. Ultimately, the images obtained from EPRI may be used to overlay the functional information (containing spatial tissue physiology information) onto detailed anatomical maps. With its ability to enable whole animal imaging in mice, EPRI will be a useful imaging technique that complements other techniques such as MRI and positron emission tomography in obtaining valuable functional/physiological images.

Anatomy, Cross-Sectional↗

Neutrophils are primary source of O2 radicals during reperfusion after prolonged myocardial ischemia.

Although many studies document oxygen radical formation during ischemia-reperfusion, few address the sources of radicals in vivo or examine radical generation in the context of prolonged ischemia. In particular, the contribution of activated neutrophils remains unclear. To investigate this issue, we developed a methodology to detect radicals without interfering with blood-borne mechanisms of radical generation. Dogs underwent aorta and coronary sinus catheterization. No chemicals were infused; instead, blood was drawn into syringes prefilled with a spin trap and analyzed by electron paramagnetic resonance spectroscopy. After 90 min of coronary artery occlusion, transcardiac concentration of oxygen radicals rose severalfold 10 min after reflow and remained significantly elevated for at least 1 h. Radicals were mostly derived from neutrophils, as shown by marked reduction after the administration of 1) neutrophil NADPH oxidase inhibitors and 2) a monoclonal antibody (R15.7) against neutrophil CD18 adhesion molecule. Reduction of radical generation by R15.7 was also associated with a significantly smaller infarct size and no-reflow areas. Thus our data demonstrate that neutrophils are a major source of oxidants in hearts reperfused in vivo after prolonged ischemia and that antineutrophil interventions can effectively prevent the increase in oxygen radical concentration during reperfusion.

Animals↗

Polynitroxyl-albumin (PNA) plus tempol attenuate lung capillary leak elicited by prolonged intestinal ischemia and reperfusion(1).

Stable nitroxyl radicals (nitroxides) are potential antioxidant drugs, and we have previously reported that linking nitroxide to biological macromolecules can improve therapeutic activity in at least two ways. First, polynitroxylated compounds such as polynitroxyl human serum albumin (PNA) are a novel class of high molecular weight, extracellular antioxidants. Second, compounds such as PNA can prolong the half-life of free (unbound, low molecular weight) nitroxides such as 4-hydroxy-2,2,6, 6-tetramethylpiperidine-N-oxyl (Tempol) in vivo. Unlike PNA, Tempol can readily access the intracellular compartment. Thus PNA can act alone in the extracellular compartment, or in concert with Tempol, to provide additional antioxidant protection within cells. In this study, we compared the abilities of PNA, Tempol, and the combination of PNA + Tempol to prevent lung microvascular injury secondary to prolonged gut ischemia (I, 120 min) and reperfusion (R, 20 min) in the rat. Pulmonary capillary filtration coefficient (K(f,c)) and lung neutrophil retention (tissue myeloperoxidase activity, MPO) were measured in normal, isolated rat lungs perfused with blood harvested from I/R rats. Blood donor rats were treated with drug during ischemia. Gut I/R resulted in a marked increase in pulmonary capillary coefficient and lung MPO. PNA + Tempol, but not PNA alone or Tempol alone, at the doses used, prevented the development of lung leak. None of the treatments had an effect on lung neutrophil retention. Anti-inflammatory therapeutic activity appeared to correlate with blood Tempol level: in the presence of PNA, blood Tempol levels were maintained in the 50-100 microM range vs. essentially undetectable levels shortly after Tempol was administered alone. In this model of lung injury secondary to prolonged gut I/R, lung capillary leak was prevented when the membrane-permeable compound Tempol was maintained in its active, free radical state by PNA.

Albumins↗

Electron paramagnetic resonance oxygen mapping (EPROM): direct visualization of oxygen concentration in tissue.

Tissue oxygen content is a central parameter in physiology but is difficult to measure. We report a novel procedure for spatial mapping of oxygen by electron paramagnetic resonance (EPR) utilizing a spectral-spatial imaging data set, in which an EPR spectrum is obtained from each image volume element. From this data set, spatial maps corresponding to local spin density and maximum EPR spectral line amplitude are generated. A map of local EPR spectral linewidth is then computed. Because linewidth directly correlates with oxygen concentration, the linewidth image provides a map of oxygenation. This method avoids a difficulty inherent in other oxygen content mapping techniques using EPR, that is, the unwanted influence of local spin probe density on the image. We provide simulation results and data from phantom studies demonstrating the validity of this method. We then apply the method to map oxygen content in rat tail tissue and vasculature. This method provides a new, widely applicable, approach to direct visualization of oxygen concentration in living tissue. Magn Reson Med 43:804-809, 2000.

Animals↗

Radiation, radicals, and images.

Nitroxide stable free radicals exhibit varied chemical and biological properties. Their biological applications have been greatly expanded over the past few years. Not only have they been shown to exhibit potent antioxidant and radioprotective properties, but also they can serve as in vivo functional imaging probes that non-invasively report on the oxygen status and redox properties of tissue, which may have utility in clinical biomedical research.

Animals↗

Targeted antioxidant properties of N-[(tetramethyl-3-pyrroline-3-carboxamido)propyl]phthalimide and its nitroxide metabolite in preventing postischemic myocardial injury.

We investigated the cardioprotective efficacy of a new compound based on 2,2,5,5-tetramethyl-3-pyrroline-3-carboxamide (TPC-NH). Biochemical studies using electron paramagnetic resonance (EPR) spectroscopy suggest that TPC-NH is a scavenger of reactive oxygen species. In vitro cellular studies show that TPC-NH protects isolated cardiomyocytes against oxidative damage caused by superoxide radicals. Ex vivo EPR studies on the isolated rat heart indicate that the TPC-NH is metabolically oxidized to the nitroxide form. Studies were also performed in the isolated rat heart model to measure the efficacy of TPC-NH and its metabolites in preventing postischemic reperfusion injury. Serial measurements of contractile function were performed on hearts subjected to ischemia-reperfusion. Hearts were either untreated or treated with 50 microM TPC-NH or with its metabolites for 1 min before ischemia and during the first 5 min of reflow. TPC-NH showed marked protection with a more than 3-fold increased recovery of contractile function compared with control hearts, whereas its oxidative metabolites exhibited significant but lower protection. Thus, TPC-NH and, to a lesser extent, its oxidation metabolites exhibit potent membrane-targeted antioxidant action and exert marked protection against myocardial injury in the postischemic heart.

Animals↗

A pyrroline derivative of mexiletine offers marked protection against ischemia/reperfusion-induced myocardial contractile dysfunction.

The efficacy and mechanism of protection of a new 2,2,5, 5-tetramethylpyrroline derivative of mexiletine, MEX-NH, against ischemia/reperfusion-induced cardiac dysfunction are reported. The MEX-NH and its nitroxide metabolite are membrane-permeable antioxidants. Studies were performed in an isolated rat heart model to measure the efficacy of MEX-NH in preventing postischemic injury. Serial measurements of contractile function and coronary flow were performed on hearts subjected to 30 min of global 37 degrees C ischemia followed by 45 min of reperfusion. Hearts were either untreated or treated with 25 microM MEX-NH or MEX for 1 min before ischemia. The hearts treated with MEX-NH showed marked recovery of left ventricular developed pressure (96.3 +/- 2.7% of preischemic value) compared with untreated (13.7 +/- 1.0%) or MEX-treated (19.9 +/- 2.7%) hearts. The cardiac sarcolemmal Na(+),K(+)-ATPase activity showed that the enzyme activity was fully restored in hearts treated with MEX-NH compared with 65 +/- 5.3% inhibition in the untreated hearts. Competitive inhibition of [(3)H]ouabain binding revealed that the MEX-NH binds at the K(+)-binding site of the enzyme. The present study establishes that the compound MEX-NH provides marked protection against ischemia/reperfusion-induced contractile dysfunction in isolated hearts. A combination of reversible inhibition of Na(+)/K(+)-ATPase activity during ischemia and site-targeted antioxidative effect upon reperfusion seems to contribute to this cardioprotection.

Animals↗

Non-enzymatic nitric oxide synthesis in biological systems.

Nitric oxide (NO) is an important regulator of a variety of biological functions, and also has a role in the pathogenesis of cellular injury. It had been generally accepted that NO is solely generated in biological tissues by specific nitric oxide synthases (NOS) which metabolize arginine to citrulline with the formation of NO. However, NO can also be generated in tissues by either direct disproportionation or reduction of nitrite to NO under the acidic and highly reduced conditions which occur in disease states, such as ischemia. This NO formation is not blocked by NOS inhibitors and with long periods of ischemia progressing to necrosis, this mechanism of NO formation predominates. In postischemic tissues, NOS-independent NO generation has been observed to result in cellular injury with a loss of organ function. The kinetics and magnitude of nitrite disproportionation have been recently characterized and the corresponding rate law of NO formation derived. It was observed that the generation and accumulation of NO from typical nitrite concentrations found in biological tissues increases 100-fold when the pH falls from 7.4 to 5.5. It was also observed that ischemic cardiac tissue contains reducing equivalents which reduce nitrite to NO, further increasing the rate of NO formation more than 40-fold. Under these conditions, the magnitude of enzyme-independent NO generation exceeds that which can be generated by tissue concentrations of NOS. The existence of this enzyme-independent mechanism of NO formation has important implications in our understanding of the pathogenesis and treatment of tissue injury.

Animals↗

Noninvasive measurement of anatomic structure and intraluminal oxygenation in the gastrointestinal tract of living mice with spatial and spectral EPR imaging.

EPR imaging has emerged as an important tool for noninvasive three-dimensional (3D) spatial mapping of free radicals in biological tissues. Spectral-spatial EPR imaging enables mapping of the spectral information at each spatial position, and, from the observed line width, the localized tissue oxygenation can be mapped. We report the development of EPR imaging instrumentation enabling 3D spatial and spectral-spatial EPR imaging of small animals. This instrumentation, along with the use of a biocompatible charcoal oximetry-probe suspension, enabled 3D spatial imaging of the gastrointestinal (GI) tract, along with mapping of oxygenation in living mice. By using these techniques, the oxygen tension was mapped at different levels of the GI tract from the stomach to the rectum. The results clearly show the presence of a marked oxygen gradient from the proximal to the distal GI tract, which decreases after respiratory arrest. This technique for in vivo mapping of oxygenation is a promising method, enabling the noninvasive imaging of oxygen within the normal GI tract. This method should be useful in determining the alterations in oxygenation associated with disease.

Animals↗