PubMed Health⌕ Search

Biomedical subjects

P L Petti

Publications and source records attributed to P L Petti.

At least 19 recordsLinked to original sources

Dose conformity of gamma knife radiosurgery and risk factors for complications.

PURPOSE: To quantitatively evaluate dose conformity achieved using Gamma Knife radiosurgery, compare results with those reported in the literature, and evaluate risk factors for complications. METHODS AND MATERIALS: All lesions treated at our institution with Gamma Knife radiosurgery from May 1993 (when volume criteria were routinely recorded) through December 1998 were reviewed. Lesions were excluded from analysis for reasons listed below. Conformity index (the ratio of prescription volume to target volume) was calculated for all evaluable lesions and for lesions comparable to those reported in the literature on conformity of linac radiosurgery. Univariate Cox regression models were used to test for associations between treatment parameters and toxicity. RESULTS: Of 1612 targets treated in 874 patients, 274 were excluded, most commonly for unavailability of individual prescription volume data because two or more lesions were included within the same dose matrix (176 lesions), intentional partial coverage for staged treatment of large arteriovenous malformations (AVMs) (33 lesions), and missing target volume data (26 lesions). The median conformity indices were 1.67 for all 1338 evaluable lesions and 1.40-1.43 for lesions comparable to two linac radiosurgery series that reported conformity indices of 1.8 and 2.7, respectively. Among all 651 patients evaluable for complications, there were one Grade 5, eight Grade 4, and 27 Grade 3 complications. Increased risk of toxicity was associated with larger target volume, maximum lesion diameter, prescription volume, or volume of nontarget tissue within the prescription volume. CONCLUSIONS: Gamma Knife radiosurgery achieves much more conformal dose distributions than those reported for conventional linac radiosurgery and somewhat more conformal dose distributions than sophisticated linac radiosurgery techniques. Larger target, nontarget, or prescription volumes are associated with increased risk of toxicity.

Brain Neoplasms↗

An application of GafChromic MD-55 film for 67.5 MeV clinical proton beam dosimetry.

The purpose of this study is to explore the use of GafChromic MD-55 (RC) film for 67.5 MeV clinical proton beam dosimetry at the Crocker Nuclear Laboratory, University of California, Davis. Several strips of RC film 6 cm x 6 cm in dimension were irradiated at a depth of 18.2 mm corresponding to the middle of a 24 mm spread-out Bragg peak (SOBP). The films were irradiated to a proton dose in the range of 0.5 Gy to 100 Gy. The beam profiles were also measured at the middle of the 24 mm SOBP. The Bragg peak was measured by using a wedge shaped phantom made of Lucite. The Bragg peak measured with RC film was compared with diode and ionization chamber measurements. After background subtraction, the calibration of the dose response of RC film showed, to a maximum deviation of 10%, a linear increase of optical density (OD) with dose from 0.5 to 100 Gy. The uniformity of OD over a single sheet of film showed a variation of +/-6%. The distal-fall off between 90% and 20% measured with GafChromic film for the Bragg peak was 1.3 mm as compared to 1.1 mm for a diode measurement and 1.4 mm for an ionization chamber measurement. The FWHM of the Bragg peak was 7.5 mm when measured with GafChromic film, 5.3 mm when measured with a diode and 8.1 mm as measured by an ionization chamber. The peak/plateau ratio with GafChromic film was 3.3 as compared to 3.7 with a diode and 3.2 with an ionization chamber. In conclusion, GafChromic MD-55 film may be a useful and convenient detector for dose measurement and quality assurance programmes of proton beams.

Cyclotrons↗

15 years experience with helium ion radiotherapy for uveal melanoma.

PURPOSE: To review the long-term experience of helium ion therapy as a therapeutic alternative to enucleation for uveal melanoma, particularly with respect to survival, local control, and morbidity. METHODS AND MATERIALS: 347 patients with uveal melanoma were treated with helium ion RT from 1978-1992. A nonrandomized dose-searching study was undertaken, with doses progressively reduced from 80 GyE in five fractions to 48 GyE in four fractions, given in 3-15 days, mean of 7 days. RESULTS: Local control was achieved in 96% of patients, with no difference in the rate of local control being seen at 80, 70, 60, or 50 GyE in five fractions. At the lowest dose level of 48 GyE in four fractions, the local control rate fell to 87%. Fifteen of 347 patients (4%) had local regrowth in the eye requiring enucleation (12 patients), laser (1 patient) or reirradiation (2 patients). The time of appearance of local regrowth ranged from 4 months to 5 years posttreatment, with 85% occurring within 3 years. Of the 347 patients, 208 are alive as of May 1, 1997. The median follow up of all patients is 8.5 years, range 1-17 years. Kaplan-Maier (K-M) survival is 80% at 5 years, 76% at 10 years, and 72% at 15 years posttreatment. Patients with tumors not involving the ciliary body have a 15-year K-M survival of 80%. The results for patients whose tumors involved the ciliary body are poor, with a 15-year K-M survival of 43%. Seventy-five percent of patients with tumors at least 3.0 mm from the fovea and optic nerve, and initial ultrasound height less than 6.0 mm, retained vision of 20/200 or better posttreatment. Patients with tumors larger than 6 mm in thickness, or with tumors lying close to the optic nerve or fovea, have a reduced chance of retaining useful vision. The enucleation rate is 19%, 3% for local failure and 16% because of complications of the helium RT, particularly neovascular glaucoma, which occurred in 35% of patients. CONCLUSIONS: Local control and retention of the eye are excellent. Complications of therapy reduce vision and eye preservation. Twenty-four percent of patients manifested distant metastases 6 to 146 months posttreatment, mean of 43 months, median of 36 months. Late-appearing distant metastases do not appear to be caused by persistent tumor in the eye. The risk of metastases is high for patients with tumors greater than 7 mm in initial ultrasound height (37%), anterior tumors involving the ciliary body (47%), and in those with local failure (53%). Patients with tumors not involving the ciliary body and initial dimensions less than 10 mm had only an 8% chance of death from melanoma. A search for effective adjuvant therapy is needed for patients at high risk of metastases (large tumors, ciliary body involved, local regrowth in eye).

Ciliary Body↗

Anterior segment sparing to reduce charged particle radiotherapy complications in uveal melanoma.

PURPOSE: The purpose of this investigation is to delineate the risk factors in the development of neovascular glaucoma (NVG) after helium-ion irradiation of uveal melanoma patients and to propose treatment technique that may reduce this risk. METHODS AND MATERIALS: 347 uveal melanoma patients were treated with helium-ions using a single-port treatment technique. Using univariate and multivariate statistics, the NVG complication rate was analyzed according to the percent of anterior chamber in the radiation field, tumor size, tumor location, sex, age, dose, and other risk factors. Several University of California San Francisco-Lawrence Berkeley National Laboratory (LBNL) patients in each size category (medium, large, and extralarge) were retrospectively replanned using two ports instead of a single port. By using appropriate polar and azimuthal gaze angles or by treating patients with two ports, the maximum dose to the anterior segment of the eye can often be reduced. Although a larger volume of anterior chamber may receive a lower dose by using two ports than a single port treatment. We hypothesize that this could reduce the level of complications that result from the irradiation of the anterior chamber of the eye. Dose-volume histograms were calculated for the lens, and compared for the single and two-port techniques. RESULTS: NVG developed in 121 (35%) patients. The risk of NVG peaked between 1 and 2.5 years posttreatment. By univariate and multivariate analysis, the percent of lens in the field was strongly correlated with the development of NVG. Other contributing factors were tumor height, history of diabetes, and vitreous hemorrhage. Dose-volume histogram analysis of single-port vs. two-port techniques demonstrate that for some patients in the medium and large category tumor groups, a significant decrease in dose to the structures in the anterior segment of the eye could have been achieved with the use of two ports. CONCLUSION: The development of NVG after helium-ion irradiation is correlated to the amount of lens, anterior chamber in the treatment field, tumor height, proximity to the fovea, history of diabetes, and the development of vitreous hemorrhage. Although the influence of the higher LET deposition of helium-ions is unclear, this study suggests that by reducing the dose to the anterior segment of the eye may reduce the NVG complications. Based on this retrospective analysis of LBNL patients, we have implemented techniques to reduce the amount of the anterior segment receiving a high dose in our new series of patients treated with protons using the cyclotron at the UC Davis Crocker Nuclear Laboratory (CNL).

Adolescent↗

Neon heavy charged particle radiotherapy of glioblastoma of the brain.

PURPOSE: High-linear energy transfer (LET) radiation beams have potential applications in the treatment of glioblastoma, but have not yet demonstrated significant improvement in results. However, some patients have had local control of glioblastoma with high-LET irradiations such as neutrons and heavy charged particles. METHODS AND MATERIALS: In this collaborative study, 15 patients were entered into a randomized protocol comparing two dose levels of 20 and 25 Gy in 4 weeks of neon ion irradiation. This trial was intended to determine the optimal neon dose in terms of survival and effects of radiation. RESULTS: Fourteen patients were evaluable with no significant differences in median survival (13 and 14 months; p = NS) or median time to failure (7 and 9 months; p = NS) between the two dose arms. Three patients died of nontumor-related causes, of whom one (who died 19 months posttreatment) had autopsy confirmation of no tumor on pathological exam. The other two patients had stable magnetic resonance imaging scans at 6 and 22 months posttreatment. CONCLUSION: Although the results did not demonstrate the optimal high-LET dose level, there is an intriguing effect in that two patients had control of glioblastoma until death at 19 and 22 months. This suggests that better conformation of the high-LET dose to the tumor with neutron capture therapy or dynamic conformal heavy charged particle therapy might control glioblastoma while minimizing brain damage from radiation.

Adult↗

Radiosurgery for brain metastases: relationship of dose and pattern of enhancement to local control.

PURPOSE: This study aimed to analyze dose, initial pattern of enhancement, and other factors associated with freedom from progression (FFP) of brain metastases after radiosurgery (RS). METHODS AND MATERIALS: All brain metastases treated with gamma-knife RS at the University of California, San Francisco, from 1991 to 1994 were reviewed. Evaluable lesions were those with follow-up magnetic resonance or computed tomographic imaging. Actuarial FFP was calculated using the Kaplan-Meier method, measuring FFP from the date of RS to the first imaging study showing tumor progression. Controlled lesions were censored at the time of the last imaging study. Multivariate analyses were performed using a stepwise Cox proportional hazards model. RESULTS: Of 261 lesions treated in 119 patients, 219 lesions in 100 patients were evaluable. Major histologies included adenocarcinoma (86 lesions), melanoma (77), renal cell carcinoma (21), and carcinoma not otherwise specified (17). The median prescribed RS dose was 18.5 Gy (range, 10-22) and the median tumor volume was 1.3 ml (range, 0.02-30.9). The initial pattern of contrast enhancement was homogeneous in 68% of lesions, heterogeneous in 12%, and ring-enhancing in 19%. The actuarial FFP was 82% at 6 months and 77% at 1 year for all lesions, and 93 and 90%, respectively, for 145 lesions receiving > or = 18 Gy. Multivariate analysis showed that longer FFP was significantly associated with higher prescribed RS dose, a homogeneous pattern of contrast enhancement, and a longer interval between primary diagnosis and RS. Adjusted for these factors, adenocarcinomas had longer FFP than melanomas. No significant differences in FFP were noted among lesions undergoing RS for recurrence after prior radiotherapy (119 lesions), RS alone as initial treatment (45), or RS boost (55). CONCLUSION: A minimum prescribed radiosurgical dose > or = 18 Gy yields excellent local control of brain metastases. The influence of pattern of enhancement on local control, a new finding in this retrospective analysis, needs to be confirmed.

Adenocarcinoma↗

New compensator design options for charged-particle radiotherapy.

The purpose of this investigation is to propose new compensator design strategies for protons and heavier particles which are based on pencil-beam (PB) dose calculations and which significantly reduce the dose to tissues downstream from the target, yet provide acceptable target coverage under conditions of patient motion. Averaging and expansion operations are provided to improve the target coverage if the patient moves slightly during treatment, and a structure-sparing option is provided to protect critical structures lying downstream from the target. The new compensator design options were evaluated for two patients who had skull-base tumours. When the patient and compensator were perfectly aligned, the new PB compensator designs provided target coverage comparable to, if not better than, standard compensator designs for both patients. Furthermore, the volume of normal tissue distal to the target which received in excess of 95% of the prescription dose was roughly a factor of two lower for the averaged PB compensators than for the expanded standard compensators. In the event of patient motion, on average, the volume of the target receiving 95% or more of the prescribed dose was 3% less for the averaged PB compensators than for the expanded standard compensators. In conclusion, the new compensator design options evaluated in this investigation provide better protection for normal tissues distal to the target volume than standard compensator designs, with only a modest decrease in target volume coverage in the event of patient motion.

Equipment Design↗

Evaluation of a pencil-beam dose calculation technique for charged particle radiotherapy.

PURPOSE: The purpose of this article is to evaluate a pencil-beam dose calculation algorithm for protons and heavier charged particles in complex patient geometries defined by computed tomography (CT) data and to compare isodose distributions calculated with the new technique to those calculated with conventional algorithms in selected patients with skull-base tumors. METHODS AND MATERIALS: Monte Carlo calculations were performed to evaluate the pencil-beam algorithm in patient geometries for a modulated 150-MeV proton beam. A modified version of a Monte Carlo code described in a previous publication (18) was used for these comparisons. Tissue densities were inferred from patient CT data on a voxel-by-voxel basis, and calculations were performed with and without tissue compensators. A dose calculation module using the new algorithm was written, and treatment plans using the new algorithm were compared to plans using standard ray-tracing techniques for 10 patients with clival chordoma and three patients with nasopharyngeal carcinoma who were treated with helium lons at Lawrence Berkeley National Laboratory (LBL). RESULTS: Pencil beam calculations agreed well with Monte Carlo calculations in the patient geometries. The pencil-beam algorithm predicted several multiple-scattering effects that are not modeled by conventional ray-tracing calculations. These include (a) the widening of the penumbra as a function of beam penetration, (b) the degradation in the sharpness of the dose gradient at the end of the particle range in highly heterogeneous regions, and (c) the appearance of hot and cold dose regions in the shadow of complex heterogeneities. In particular, pencil-beam calculations indicated that the dose distribution within the target was not as homogeneous as expected on the basis of ray-tracing calculations. On average, for the 13 patients considered, only about 72% of the conedown target volume received at least 99% of the prescribed dose, whereas, 93% of the conedown volume was contained within the 95% isodose surface. This may be significant because in standard charged particle dose calculations, the dose across the spread-Bragg peak is assumed to be uniform and equal to the maximum or prescribed dose. CONCLUSIONS: Dose distributions computed with the pencil-beam model are more accurate than ray-tracing calculations, providing additional information to clinicians, which may influence the doses they prescribe. In particular, these calculations indicate that for some patients with skull-base tumors, it may be advantageous to prescribe proton doses to a lower isodose level than is commonly done.

Algorithms↗

Gamma knife radiosurgery in children.

52 pediatric patients were treated with radiosurgery at the University of California, San Francisco. Arteriovenous malformations were treated in 27 patients. Complete obliteration was noted in 4 of 12 patients imaged more than 2 years after radiosurgery. Arteriovenous malformation rebleed was noted in 1 patient. Symptomatic T2 changes were noted in 2 patients. Among 29 neoplasms treated in 25 patients, local control was noted in 5 of 7 low-grade gliomas, 5 of 14 high-grade gliomas, 4 of 5 craniopharyngiomas and 3 of 3 sarcomas. Three patients treated for neoplasms developed necrosis after radiosurgery.

Adolescent↗

Experience in charged particle irradiation of tumors of the skull base: 1977-1992.

PURPOSE: To review the experience at University of California Lawrence Berkeley Laboratory in using charged particles to irradiate primary neoplasms of the skull base and those extending to the skull base from the nasopharynx and paranasal sinuses. METHODS AND MATERIALS: During the period from 1977 to 1992, 223 patients were irradiated with charged particles at the Lawrence Berkeley Laboratory for tumors either arising in or extending to the skull base, of whom 48 (22%) had recurrent lesions, either post previous surgery or radiotherapy. One hundred twenty-six patients had lesions arising in the cranial base, mostly chordoma (53), chondrosarcoma (27), paraclival meningioma (27) with 19 patients having other histologies such as osteosarcoma or neurofibrosarcoma. There were also 31 patients with primary or recurrent squamous carcinoma of the nasopharynx extending to the skull base, 44 patients with major or minor salivary gland tumors, mostly adenocarcinoma, and 22 patients with squamous carcinoma of the paranasal sinuses, all with cranial base extension. RESULTS: Local control and survival appeared improved in tumors arising in the skull base, following the ability with charged particles to deliver high doses (mean of 65 Gy-equivalent) with relative sparing of the adjacent normal tissues. The Kaplan-Meier 5-year local control was 85% for meningioma, 78% for chondrosarcoma, 63% for chordoma and 58% for other sarcoma. Follow-up ranged from 4-191 months with a median of 51 months. CONCLUSION: Charged particle radiotherapy is highly effective in controlling cranial base lesions which have have been partially resected. Better tumor localization with CT and MRI, improved 3-D treatment planning and beam delivery techniques have continued to reduce the level of serious complications and increase local control and survival.

Female↗

An automated image-registration technique based on multiple structure matching.

A new image-registration technique that matches multiple structures on complementary imaging data sets (e.g., CT and MRI) has been developed and tested with both phantom and patient data. The algorithm assumes a rigid-body transformation and is suitable for correlating structures within the cranium or at the skull base. The basic premise of the new technique is that an optimum transformation is achieved when the relative volume lying outside of the intersection between a structure and its transformed counterpart is a minimum. This relative volume is calculated numerically using a random sampling approach, and a binary searching algorithm was used to step through the nine-dimensional parameter space consisting of three rotation angles, three scaling factors and three components of a translation vector. For the nine tests using phantom data, the automated structure-matching technique was able to predict the correct rotation angles to within +/- 1 degree. The expected clinical performance of the new technique was assessed by comparing results obtained with the new method to those obtained using other techniques for 12 patients who were treated with charged particles at Lawrence Berkeley Laboratory (LBL) and who had image-registration studies performed as part of their treatment plan. For 9 of the 12 patients considered, the new structure-matching technique produced a significantly better registration than the older methods, as measured by the resultant average relative volume lying outside of the intersection between any structure and its transformed counterpart. For the other three patients, results were not significantly different for the new structure-matching method and the older techniques.

Algorithms↗

Charged particle irradiation of sacral chordomas.

PURPOSE: The purpose of this report is determine the impact of charged particle irradiation at Lawrence Berkeley Laboratory (LBL) in treating patients with sacral chordomas. Overall survival, local control, complications, and predictive parameters are analyzed. METHODS AND MATERIALS: Fourteen patients with sacral chordomas were treated with the charged particles helium and neon between 1977 and 1989. The median dose was 7565 cGyE and the median follow up is 5 years. All patients were treated post-operatively; ten had gross residual disease. RESULTS: Kaplan-Meier survival at 5 years is 85%. Overall 5-year local control is 55%. A trend to improved local control at 5 years was seen in patients treated with neon when compared to patients treated with helium (62% vs 34%), in patients following complete resection versus patients with gross residual tumor (75% vs 40%), and in patients who had treatment courses under 73 days (61% vs 21%). Distant metastases were seen in two patients (14%). No patient developed neurologic sequelae or pain syndromes. One previously irradiated patient required colostomy, one patient had delayed wound healing following a negative post-radiation biopsy, and one patient developed a second malignancy. There were no genitourinary complications. CONCLUSION: Our experience indicates that post-operative charged particle irradiation of sacral chordomas appears to result in reasonable local control and survival with acceptable risk, and that additional evaluation on the use of heavy charged particles is warranted.

Adult↗

Clinical gain from improved beam delivery systems.

The feasibility of dynamic conformal heavy charged particle radiotherapy has been investigated at UCLBL, and shows high promise of: 1. an improved therapeutic ratio and 2. reduction in the number of treatment portals required for efficient treatment delivery. Assessment of dose to tumor and critical structures for several anatomical sites have been carried out using a normal tissue complication algorithm developed at LBL. For high-LET charged particle treatment delivery, dynamic conformal therapy using a raster scanned beam with variable modulation and multileaf collimator appears to be the optimal technique for treatment delivery.

Energy Transfer↗

Charged particle radiotherapy of paraspinal tumors.

Between 1976 and 1987, 52 patients with tumors adjacent to and/or involving the cervical, thoracic, or lumbar spinal cord were treated with charged particles at the University of California Lawrence Berkeley Laboratory. The histologies included chordoma and chondrosarcoma (24 pts), other bone and soft tissue sarcoma (14 pts), and metastatic or unusual histology tumors (14 pts). Radiation doses ranged from 29 to 80 Gray-equivalent (GyE), with a median dose of 70 GyE. Twenty-one patients received a portion of their treatment with photons. Median followup was 28 months. For 36 previously untreated patients, local control was achieved in 21/36 patients and the 3-year actuarial survival was 61%. Of 16 patients treated for recurrent disease, 7/16 were locally controlled and the 3-year actuarial survival was 51%. For patients treated for chordoma and chondrosarcoma, probability of local control was influenced by tumor volume (less than 100 cc or greater than 150 cc) and whether disease was recurrent or previously untreated. Complications occurred in 6/52 patients, including one spinal cord injury, one cauda equina and one brachial plexus injury, and three instances of skin or subcutaneous fibrosis. Charged particle radiotherapy can safely deliver high tumor doses to paraspinal tumors with good local control.

Adolescent↗

Preliminary results in heavy charged particle irradiation of bone sarcoma.

Between 1979 and 1989, 17 patients with unfavorable bone sarcoma were treated wholly or in part with heavy charged particle irradiation (helium and/or neon ions) at the University of California Lawrence Berkeley Laboratory. The majority of tumors were located near critical structures such as the spinal cord or brain. Gross tumor was present in all but two patients at the time of irradiation. Six patients were treated for recurrent disease. Histologies included osteosarcoma, Ewing's sarcoma, and recurrent osteoblastoma. Four of the osteosarcomata were believed to have been induced by previous therapeutic irradiation for various tumors. Follow-up time since initiation of radiation ranged from 7 to 118 months (median 40 months). The 5-year Kaplan-Maier local control rate was 48%; the corresponding survival rate was 41%. Over half the patients succumbed to distant metastases despite the majority of patients receiving chemotherapy. In this preliminary study, we have shown that heavy charged particle irradiation can be effectively used for control of bone sarcoma. A Phase II trial is warranted to determine optimal treatment for unresectable or gross residual disease.

Antineoplastic Combined Chemotherapy Protocols↗

Uveal melanoma: development of metastases after helium ion irradiation.

Forty-two (16%) of 261 patients with ocular melanoma who were treated with helium ions between January 1978 and November 1986 have developed metastatic disease. The time between start of helium ion treatment and recognition of metastatic disease ranged from 3 to 67 months (median, 27 months). The mean pretreatment tumor height in the patients with metastases was 7.7 mm. All 42 patients who developed metastatic disease have died. The median survival after diagnosis of metastatic disease was 5 months; the longest survival was 49 months. The most common site of metastasis was the liver (n = 34). Four (10%) of the 42 patients with metastases also had local recurrence of the tumor. Multivariate analysis identified three variables that predicted independently the development of metastases and lack of survival. These variables are anterior location of tumor (P = .027), tumor height greater than 5 mm (P = .02), and tumor diameter greater than 10 mm (P = .0075).

Actuarial Analysis↗

Ciliary body melanoma treated with helium particle irradiation.

Melanoma involving the ciliary body is a rare tumor which carries a poor prognosis when compared to all uveal melanoma. We have treated 54 patients with ciliary body melanoma using helium ions from 1978 to 1985. Because of the high rate of metastatic disease, the 5-year disease specific survival rate is only 59% despite a 5-year local control rate of 98%. The greatest diameter of the tumor was predictive of loss of vision and enucleation (p = .05, p = .04, respectively). Multivariate analysis showed that the greatest diameter of the tumor was the most important predictor of death from metastases. The incidence of neovascular glaucoma at 5 years is 43%. The 5-year actuarial rate of enucleation is 26%. Enucleation was done for pain and/or neovascular glaucoma. Univariate analysis showed treatment volume to be a statistically significant predictor for the development of neovascular glaucoma (p = .0017) and enucleation (p = .0078). Seventy percent of neovascular glaucoma occurred in patients with treatment volume greater than 5.5 cc. Seventy-four percent occurred in patients with an initial ultrasound height greater than 9.2 mm. Using this information, patients at high risk for neovascular glaucoma could be considered for prophylactic treatment with panretinal photocoagulation.

Adult↗

Charged particle radiotherapy for lesions encircling the brain stem or spinal cord.

Since 1981, a specialized technique has been under development at the University of California Lawrence Berkeley Laboratory for charged particle irradiation of tumors partially or completely encircling the brain stem or spinal cord. By dividing the target volume into two or more portions and using a combination of beams, a reasonably homogeneous irradiation of the target volume can be obtained which protects critical CNS structures from over-irradiation. This technique requires knowledge of the physical and biological effects of charged particles, precise, reproducible patient immobilization, careful treatment planning based upon Metrizamide contrast CT and/or MRI scanning, compensation for tissue inhomogeneities, and accurate, verifiable radiation delivery. Uncertainties in the dose distribution must be taken into account when prescribing treatment. We have used this technique in 47 patients with a variety of tumors abutting the brain stem and spinal cord, including chordoma, chondrosarcoma, meningioma, osteosarcoma and metastatic tumors. The results have shown a significant local control rate (62%) and the incidence of serious complications has been acceptable (13%). The median follow-up is 20 months with a range of 6-90 months. We conclude that charged particles can be safely and effectively used to irradiate lesions encircling the brain stem or spinal cord to doses higher than can be achieved with low-LET irradiation.

Brain Neoplasms↗