PubMed Health⌕ Search

Biomedical subjects

P Lamm

Publications and source records attributed to P Lamm.

At least 19 recordsLinked to original sources

Association between vasopressor dependence and early outcome in patients after cardiac surgery.

Arterial hypotension with vasopressor dependence is a major problem after cardiac surgery. We evaluated the early postoperative course of 1558 consecutive patients scheduled for cardiac surgery, and compared the outcome of patients with and without vasopressor dependence (defined as the need for > 0.1 microg x kg(-1) x h(-1) noradrenaline for > 3 h in the face of normovolaemia). Vasopressor dependence was diagnosed in 424 patients (27%) and was associated with a higher incidence of postoperative renal failure (67 (15.7%) vs 7 (0.6%), respectively; p < 0.0001), a longer duration of ventilation (median IQR [range]) 14 (8-26 [6-39]) h vs 8 (5-11 [4-32]) h; p < 0.0001), a greater need for red cell transfusion (3 (1-5 [0-10]) units vs 1 (0-2 [0-4]) units; p < 0.001) and a longer length of stay in the ICU (4 (2-6 [2-9] days) vs 2 (1-3 [1-6] days; p < 0.001). Vasopressor dependence could be predicted from a combination of factors, including pre-operative ejection fraction < 37%, cardiopulmonary bypass lasting > 94 min, and postoperative interleukin-6 > 837 pg x ml(-1).

Aged↗

Trendelenburg positioning after cardiac surgery: effects on intrathoracic blood volume index and cardiac performance.

BACKGROUND AND OBJECTIVE: The efficacy of the Trendelenburg position, a common first step to treat suspected hypovolaemia, remains controversial. We evaluated its haemodynamic effects on cardiac preload and performance in patients after cardiac surgery. METHODS: Twelve patients undergoing mechanical ventilation of the lungs who demonstrated left ventricular 'kissing papillary muscles' by transoesophageal echocardiography, thus suggesting hypovolaemia, were positioned 30 degrees head down for 15 min immediately after cardiac surgery. Cardiac output by thermodilution, central venous pressure, pulmonary artery occlusion pressure, left ventricular end-diastolic area by transoesophageal echocardiography and intrathoracic blood volume by thermo- and dye dilution were determined before, during and after this Trendelenburg manoeuvre. RESULTS: Trendelenburg's manoeuvre was associated with increases in central venous pressure (9 +/- 2 to 12 +/- 3 mmHg) and pulmonary artery occlusion pressure (8 +/- 2 to 11 +/- 3 mmHg). The intrathoracic blood volume index increased slightly (dye dilution from 836 +/- 129 to 872 +/- 112 mL m(-2); thermodilution from 823 +/- 129 to 850 +/- 131 mL m(-2)) as did the left ventricular end-diastolic area index (7.5 +/- 2.1 to 8.1 +/- 1.7 cm2 m(-2)), whereas mean arterial pressure and the cardiac index did not change significantly. After supine repositioning, the cardiac index decreased significantly below baseline (3.0 +/- 0.6 versus 3.5 +/- 0.8 L min(-1) m(-2)) as did mean arterial pressure (76 +/- 12 versus 85 +/- 11 mmHg), central venous pressure (8 +/- 2 mmHg) and pulmonary artery occlusion pressure (6 +/- 4 mmHg). The intrathoracic blood volume index and left ventricular end-diastolic area index did not differ significantly from baseline. CONCLUSIONS: Trendelenburg's manoeuvre caused only a slight increase of preload volume, despite marked increases in cardiac-filling pressures, without significantly improving cardiac performance.

Blood Volume↗

Optimizing fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations. Comparison with aortic systolic pressure variations.

BACKGROUND: Mechanical ventilation causes changes in left ventricular preload leading to distinct variations in left ventricular stroke volume and systolic arterial pressure. Retrospective off-line quantification of systolic arterial pressure variations (SPV) has been validated as a sensitive method of predicting left ventricular response to volume administration. We report the real-time measurement of left ventricular stroke volume variations (SVV) by continuous arterial pulse contour analysis and compare it with off-line measurements of SPV in patients after cardiac surgery. METHODS: SVV and SPV were determined before and after volume loading with colloids in 20 mechanically ventilated patients. RESULTS: SVV and SPV decreased significantly after volume loading and were correlated (r=0.89; P<0.001). Changes in SVV and changes in SPV as a result of volume loading were also significantly correlated (r=0.85; P<0.005). Changes in SVV correlated significantly with changes in stroke volume index (SVI) (r=0.67; P<0.005) as did changes in SPV (r=0.56; P<0.05). SVV determined before volume loading correlated significantly with changes in SVI (R=0.67; P <0.005). Using receiver operating characteristics curves, the area under the curve was statistically greater for SVV (0.824; 95% confidence interval: [CI] 0.64-1.0) and SPV (0.81; CI: 0.62-1.0) than for central venous pressure (0.451; CI: 0.17-0.74). CONCLUSIONS: Monitoring of SVV enables real-time prediction and monitoring of the left ventricular response to preload enhancement in patients after cardiac surgery and is helpful for guiding volume therapy.

Aorta, Abdominal↗

Continuous graft perfusion: optimizing the quality of saphenous vein grafts.

BACKGROUND: Healthy unaltered vascular endothelium in graft material is a prerequisite for a successful CABG operation. Damage done to the endothelium during vein harvest is responsible for an early graft occlusion rate of 20% in the first year after operation. Minimally invasive vein harvesting is regarded to minimize the damage done to the Endothelium. We compared minimally invasive vein harvesting with conventional vein harvesting and studied the influence of a continuous perfusion of the veins with patient autologous blood on their endothelial integrity. METHODS: 80 patients were randomly split into 4 groups: Group 1: Conventional vein harvest and storage of the vein in a crystalloid solution before usage. Group 2: Endoscopic vein harvest and storage in cristallloid solution. Group 3: Conventional harvest under continuous perfusion of the vein with 100 ml blood via the heart lung machine. Group 4: Endoscopic vein harvest under continuous perfusion. Immediately prior to the first peripheral anastomosis a sample was taken from each graft and evaluated by scanning electron microscopy. The endothelial integrity was rated in 5 categories (from "completely confluent endothelium" (1) to "no endothelium" (5)). RESULTS: Group 1: 2.7+/-1.13 Group 2: 2.2+/-1.06 Group 3: 1.6+/-0.68 Group 4: 1.6+/-0.69 CONCLUSION: In regard to the endothelial integrity endoscopic vein harvesting is superior to conventional vein harvest. If the grafts are harvested while continuously perfused with blood there is no more difference between the groups. Considering the well known additional benefits such as reduction in wound healing disorders endoscopic vein harvesting appears to be the preferable technique.

Angioscopy↗

Autologous endothelialized vein allograft: a solution in the search for small-caliber grafts in coronary artery bypass graft operations.

BACKGROUND: Early graft failure after the use of less satisfactory autologous grafts (30% of all vein grafts) is caused primarily by the following problems: (1) suitable autologous transplants are limited; (2) biotechnology has not yet been able to produce reliable graft substitutes that are legally and ethically approved; and (3) current prosthetic materials are prothrombotic. To overcome these problems, we developed an easily accessible, quality-controlled graft. METHODS AND RESULTS: Human autologous venous endothelial cells (HAVECs) were isolated from short segments of peripheral veins unsuitable for bypass grafting. After mechanical deendothelialization of cryopreserved allograft veins (CAVs) and precoating with recipient autologous serum, these homologous cells were seeded by use of a rotating device. Growth of a confluent HAVEC layer within 1 week in a special incubator was observed. After histological and mechanical tests, 12 patients received 15 grafts in total. Bypass operation was followed by clinical and angiographic follow-up. Production period was 22+/-8 days. HAVEC-coated CAVs showed normal connective tissue wall structure and a tight endothelial monolayer (burst pressure >2000 mm Hg). To date, 12 CABG patients lacking suitable autologous graft material have been treated. One patient died of a cause unrelated to the grafts, which were found morphologically normal and patent during autopsy. Of 15 grafts, 2 were occluded at the first angiographic follow-up. The oldest graft has now been in place for approximately 3 years. Immune suppression was not administered. CONCLUSIONS: At present, autologous endothelialized CAVs present good alternative small-caliber grafts for patients lacking suitable autologous vessels.

Aged↗

Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination.

PURPOSE: To evaluate the performance of two different continuous cardiac output monitoring systems based on the thermodilution principle in critically ill patients. METHODS: Nineteen cardiac surgical patients were randomly assigned to continuous cardiac output monitoring using one of the two systems under study (group I, IntelliCath(TM) catheter, n=9; group II, Opti-Q(TM) catheter, n=10). Each patient was studied over a period of three hours. Conventional bolus thermodilution cardiac output measurements were carried out every 15 min leading to 13 measurements in each patient. The continuous cardiac output values were compared with the bolus thermodilution measurements. Bias (mean difference between continuous and bolus thermodilution) and precision (SD of differences) were calculated as a measure of agreement between the respective continuous method and conventional bolus thermodilution. RESULTS: The range of measured cardiac outputs was 3.8-15.4 L*min(-1) (IntelliCath(TM)) and 3.5-8.3 L*min(-1) (OptiQ(TM)). Bias and precision was 0.06 +/- 0.76 L*min(-1) (IntelliCath(TM)) and -0.04 +/- 0.74 L*min(-1) (OptiQ(TM)), respectively. There was no difference in bias between the two systems (P=0.38). +/- 2 SD of the differences (i.e., 95% of the differences) did not fall within the predetermined limits of agreement of +/- 0.5 L*min(-1). CONCLUSIONS: There was no difference between the two systems regarding the agreement with conventional bolus thermodilution as the standard. A discrepancy between bolus and continuous thermodilution cardiac output measurement techniques above the clinically acceptable limits suggest that they are not interchangeable.

Adult↗

Intensive care after minimally invasive and conventional coronary surgery: a prospective comparison.

OBJECTIVE: The purpose of this study was to compare the intensive care course of patients after minimally invasive coronary surgery to conventional coronary artery bypass grafting. DESIGN: Prospective observational study. SETTING: Intensive care unit of a university hospital. PATIENTS AND PARTICIPANTS: One hundred and five patients with two-vessel disease consecutively scheduled for elective coronary bypass surgery were enrolled. INTERVENTIONS: Two techniques of revascularization were performed: the Octopus procedure via median sternotomy without cardiopulmonary bypass (n = 52) and conventional coronary artery bypass grafting CABG (n = 53). MEASUREMENTS AND RESULTS: Three major categories describing the patients' postoperative course were defined: (1) clinical and laboratory findings, i.e., transfusion rate, catecholamine support, duration of ventilation, Simplified Acute Physiology Score II (SAPS II), serum levels of cardiac enzymes and lactic acid; (2) postoperative complications, i.e., incidence of myocardial infarction (MI), atrial fibrillation (AF), and neurological deficits; (3) this category was defined as "the extent of care" as represented by the Therapeutic Intervention Scoring System (TISS), and the length of stay in the ICU and in the hospital. In the Octopus group significantly lower figures were noted for duration of ventilation [6.1(5.5/9.5) vs 10.2(8.2/11.8) h], cardiac enzymes (CK-MB-Mass [5.1(2.0/8.3) vs 31.3(21.4/39.3) ng/ml], and lactic acid [2.0(1.5/3.3) vs 3.2(2.2/6.5) mmol/l]), incidence of AF (2/52 vs 9/53), and neurological deficits (0/52 vs 4/53), TISS score [72(44/83) vs 84(73/93)], LOS in the ICU [2(1/2) vs 2(2/2) days], and in the hospital [6(5/9) vs 9(8/12) days]. Catecholamine support, SAPS II scores, and incidence of MI of each group did not differ significantly. CONCLUSIONS: Off-pump coronary surgery via the Octopus technique was superior to conventional CABG regarding the course of patients in the early postoperative period. This implies benefits for the patients and the entire healthcare system.

APACHE↗

Re-OPCAB vs. Re-CABG for myocardial revascularization.

BACKGROUND: The present study compared redo coronary artery bypass grafting (Re-OPCAB) techniques with conventional redo coronary artery bypass grafting (Re-CABG) with particular focus on myocardial damage and clinical outcome parameters. METHODS: Redo OPCAB (Re-OPCAB) was performed on 20 consecutive patients (15 males, mean age 63.2 +/- 9.3 years) using either the anterolateral approach for minimally invasive direct coronary artery bypass (n = 4) or the Octopus technique with regular sternotomy (n = 16). The Re-CABG group consisted of 20 consecutive patients (18 males, mean age 67.1 +/- 6.6 years). Groups did not differ in the number of atherosclerotic risk factors, or left ventricular, renal or liver function. RESULTS: Duration of surgery, number of bypass grafts and amount of transfused red blood cells did not differ significantly between both groups. Requirement of epinephrine (mg/h) within the first 24 h was lower in the Re-OPCAB group (Re-OPCAB: 0.14 +/- 0.22 vs. CABG: 0.88 +/- 0.97; p<0.01). In addition, CKMB levels at 24 h after operation were lower in the Re-OPCAB group (Re-OPCAB: 10.0 +/- 10.1 vs. Re-CABG: 38.7 +/- 28.1 U/l, p<0.001). There were no acute myocardial infarctions or deaths in the perioperative period. In the CABG group, there was a longer time period to extubation (hours) (Re-OPCAB: 9.8 +/- 3.9 vs. Re-CABG: 28.7 +/- 25.5; p<0.001), and the length of ICU stay was significantly prolonged (OPCAB: 1.3 +/- 0.5 versus Re-CABG: 4.4 +/- 8.7; p<0.001). The graft patency rate at follow-up was 95% in the Re-OPCAB group. CONCLUSION: Re-OPCAB results in decreased cardiac specific enzyme release, reduced requirement of inotropes and comparable clinical outcome in the early postoperative period. It is an appropriate alternative to conventional Re-CABG in selected patients awaiting reoperation for myocardial revascularization. Larger prospective and randomized trials are required to select the appropriate patient who benefits most from one or the other treatment regime.

Aged↗

The harmonic scalpel: optimizing the quality of mammary artery bypass grafts.

BACKGROUND: The damage done to the endothelium during the preparation of a graft used in an aortocoronary procedure is a risk factor for early graft failure. We compared the effect on the endothelium of the mammary arteries when the harvest was done either by the harmonic scalpel (HS) or the high-frequency electrocauter (HF). METHODS: Twenty-four mammary arteries were harvested and divided into two groups depending on the use of the HS or the HF. The endothelial damage was analyzed with a scanning electron microscope. The groups were compared in regard to the size of the internal mammary artery (IMA) pedicle. RESULTS: The endothelial damage of the IMAs taken down with the HS was significantly less than when taken down with the HF if the IMA pedicle size was less than 0.5 cm. CONCLUSIONS: The HS has a positive effect on the endothelial preservation, especially when the preparation is done closely to the IMA. The HS is profitable in minimally invasive procedures, particularly when it is difficult to keep a wide enough distance from the IMA.

Electrocoagulation↗

Markers of myocardial ischemia after minimally invasive and conventional coronary operation.

BACKGROUND: The purpose of this study was to evaluate the course of serum markers of myocardial tissue damage after two different types of minimally invasive coronary surgical procedures (MICS) as compared with conventional coronary artery bypass grafting (CABG). METHODS: We enrolled 87 patients with one- or two-vessel disease scheduled for one of the three procedures: minimally invasive direct coronary artery bypass grafting (MIDCABG) by lateral thoracotomy (n = 29), the OCTOPUS method by median sternotomy (n = 27), and CABG (n = 31). Creatine kinase activity (CK), creatine kinase MB activity (CK-MB act), creatine kinase MB mass concentration (CK-MB mass), myoglobin concentration (MG), and cardiac troponin I concentration (cTnI) were measured perioperatively until the second postoperative day. RESULTS: Creatine kinase-MB, CK-MB mass, and cTnI were significantly higher after CABG and were nearly maintained within the normal range in MICS. Creatine kinase and MG were significantly lower in the OCTOPUS group than in the MIDCABG or CABG groups. CONCLUSIONS: Minimally invasive coronary surgical procedures cause less myocardial injury than CABG as indicated by specific serum markers. However, higher CK and MG reflect more substantial skeletal muscle trauma during MIDCABG operation compared with OCTOPUS procedures.

Adult↗

Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: a prospective criterion standard study in patients after cardiac surgery.

OBJECTIVE: To evaluate the accuracy of a new pulse contour method of measuring cardiac output in critically ill patients. DESIGN: A prospective criterion standard study. SETTING: Cardiac surgery intensive care unit in a university hospital. PARTICIPANTS: Nineteen cardiac surgery patients requiring intensive care treatment with pulmonary artery catheters after surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The pulse contour cardiac output monitor uses transpulmonary bolus thermodilution measurements to calibrate the system. In each patient, the pulse contour cardiac output values were compared with conventional thermodilution. The method described by Bland and Altman and linear regression analysis were used for comparison. The mean difference (bias) +/- standard deviation of differences (precision) was 0.31 +/- 1.25 L/min for pulmonary bolus thermodilution cardiac output versus pulse contour cardiac output and 0.21 +/- 0.73 L/min for pulmonary bolus thermodilution cardiac output versus transpulmonary bolus thermodilution cardiac output. Linear regression (correlation) analyses were pulse contour cardiac output = 0.97 thermodilution + 0.53 (r = 0.88), and transpulmonary cardiac output = 0.87 thermodilution + 1.09 (r = 0.96). There was a small increase 60 minutes after recalibration but not a statistically significant difference between pulse contour cardiac output and pulmonary bolus thermodilution cardiac output (p = 0.52). CONCLUSIONS: Bias and precision are acceptable, and the system provides results that agree with conventional thermodilution. This study demonstrates the clinical applicability of the pulse contour cardiac output monitoring system.

Adult↗

Less invasive, continuous hemodynamic monitoring during minimally invasive coronary surgery.

BACKGROUND: Minimally invasive coronary surgery has gained more and more clinical acceptance. A clear contrast to the minimally invasive idea is the highly invasive pulmonary artery catheter used for hemodynamic monitoring during the operation. We evaluated a less invasive device which calculates cardiac output (CO) and hemodynamics based on arterial pulse-contour analysis. METHODS: In 20 patients revascularized by the off-pump technique with the octopus system, agreement of CO by pulse-contour was compared to pulmonary arterial and femoral arterial thermodilution and hemodynamic alterations during the operation were recorded. Pulse-contour CO is computed by measuring the area under the arterial pressure waveform and dividing it by aortic impedance. Aortic impedance is determined by an arterial thermodilution at the onset of the system. RESULTS: Correlation of pulmonary arterial and arterial thermodilution CO to pulse-contour CO was 0.91 and 0.90 respectively (both p<0.01). Coefficients of variations were 6.2% and 6.7%. The bias was 0.1 L per minute and standard deviations were 0.42 L per minute and 0.55 L per minute. Hemodynamic changes during the operations were seen mainly during the distal anastomosis of the first diagonal branch; only slight changes occurred during the anastomosis of the left anterior descending coronary artery. CONCLUSIONS: Arterial pulse-contour analysis is easy to use and minimally invasive, thus qualifies as a reliable routine monitoring tool during minimally invasive coronary surgery with tissue stabilizers.

Aged↗

Surgical versus medical care for postoperative cardiac surgical patients at the general ward.

OBJECTIVES: To shorten hospital stay after cardiac surgery, several risk factors have been defined to identify patients who can be discharged early. These risk factors are dependant on the patient; no studies exist on the influence of the treating physician himself on postoperative patient stay. METHODS: In a university affiliated cardiac surgical clinic we investigated patients who were postoperatively treated either on medical wards with no cardiac surgeon's presence or on a cardiac surgical ward; at both types of wards physicians had several years experience with cardiac surgical patients. Taking several risk factors for postoperative morbidity into account, postoperative length of stay and incidence of wound healing complications have been compared. RESULTS: Within a 3-month period, 84 patients were treated at the cardiac surgical ward, 102 patients at the medical wards. Risk factors for postoperative morbidity were present in 87% of patients, statistically independent of postoperative wards. Although demographic data and median ICU-stay of both patient groups was comparable, the median post-ICU stay was 9 days at the surgical and 13 days at the medical wards (P < 0.0001). Incidence of wound healing complication was higher (19.6%) at the medical wards than at the surgical ward (10.7%), without reaching statistical significance. CONCLUSION: As patients at the respective wards were statistically not different, the difference in post-ICU stay, infection and costs must depend on the treating physicians. As a consequence, postoperative care for cardiac surgical patients in all cases should include direct cardiac surgical participation.

Aged↗

Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution.

OBJECTIVE: To compare two thermodilution methods for the determination of cardiac output (CO)-thermodilution in the pulmonary artery (COpa) and thermodilution in the femoral artery (COa)-with each other and with CO determined by continuous pulse contour analysis (COpc) in terms of reproducibility, bias, and correlation among the different methods. Good agreement between the methods would indicate the potential of pulse contour analysis to monitor CO continuously and at reduced invasiveness. DESIGN: Prospective criterion standard study. SETTING: Cardiac surgical intensive care unit in a university hospital. PATIENTS: Twenty-four postoperative cardiac surgery patients. INTERVENTIONS: Without interfering with standard hospital cardiac recovery procedures, changes in CO as a result of the postsurgical course, administration of vasoactive substances, and/or fluid administration were recorded. CO was first recorded after a 1-hr stabilization period in the intensive care unit and hourly thereafter for 6 hrs, and by subsequent determinations at 9, 12, and 24 hrs. MEASUREMENTS AND MAIN RESULTS: There were 216 simultaneous determinations of COpa, COa, and COpc. COpc was initially calibrated using COa, and no further recalibration of COpc was performed. COpa ranged from 3.0 to 11.8 L/min, and systemic vascular resistance ranged from 252 to 2434 dyne x sec/cm5. The mean difference (bias) +/-2 SD of differences (limits of agreement) was -0.29+/-1.31 L/min for COpa vs. COa, 0.07+/-1.4 L/min for COpc vs. COpa, and -0.22+/-1.58 L/min for COpc vs. COa. In all but four patients COpc correlated with COa after the initial calibration. Correlation and precision of COpc vs. COa was stable for 24 hrs. CONCLUSIONS: Femoral artery pulse contour CO correlates well with both COpa and COa even during substantial variations in vascular tone and hemodynamics. Additionally, CO determined by arterial thermodilution correlates well with COpa. Thus, COa can be used to calibrate COpc.

Adult↗

Reduction of wound healing problems after median sternotomy by use of retention sutures.

Obese people have a higher risk of sternal wound dehiscence resulting from traction of suprasternal tissue. In such patients we recommend the use of retention sutures with extracorporeal plates to improve tissue connection and to disburden fascia and skin sutures. This augmented closure is simple and effective and, since 1996, has prevented wound healing problems in more than 50 patients with a body mass index greater than 27.

Body Mass Index↗