PubMed Health⌕ Search

Biomedical subjects

P Leimeister

Publications and source records attributed to P Leimeister.

3 recordsLinked to original sources

[Computed tomography of the abdomen with multidetector-array CT].

BACKGROUND: The advent of multidetector CT (MDCT) constitutes a quantum leap creating a wealth of new opportunities in medical imaging. However, while the basic principles of spiral CT still apply, we are now challenged to rethink our strategies in planning a CT study to take full advantage of the increased capabilities of MDCT. MATERIALS AND METHODS: We report here our preliminary experiences with MDCT for abdominal CT imaging within a 5-month period. During this time, suitable protocols for investigation of the abdomen using MDCT were developed. The capabilities of MDCT allow for tailoring dedicated CT protocols for routine applications as well as for biphasic liver studies and CT angiography of the aorta and abdominal vessels. RESULTS: The speed of MDCT can either be used to reduce the time needed to cover a given volume, or to use narrower beam collimations to increase the resolution of detail along the z-axis and reduce volume averaging. Higher scan speed allows reduction of the amount of contrast material in vascular applications and suppression of motion artifacts. Higher spatial resolution with thinner collimations reduces volume averaging and improves the detection of small hepatic and pancreatic lesions. Detailed analysis of vascular structures and high-quality three-dimensional reformations become feasible. New problems arise from the large amount of data generated by MDCT. CONCLUSIONS: MDCT offers a wealth of new opportunities that help us to come to a fast and accurate diagnosis in suspected abdominal disease. Traditional indications for performing CT are reemphasized and new clinical applications can be exploited.

Abdomen↗

[Image analysis in multislice spiral CT of the lung with MPR and MIP reconstructions].

PURPOSE: To test, whether axial, coronal and sagittal MIP and MPR reconstructions of diagnostic quality can be obtained from 1-mm collimation MSCT data of the chest for the evaluation of thoracic anatomy and pathology. MATERIALS AND METHODS: 1-mm collimation MSCT scans were obtained with a pitch of 6 in an acrylic phantom and in 20 patients. Axial images were reconstructed with 0.6-mm increment. Multiplanar reformations (MPRs) and sliding thin-slab maximum intensity projections (STS-MIPs) were reconstructed in axial, coronal and sagittal planes. Images were printed in lung windows and evaluated by three readers by using a standardized evaluation scheme. RESULTS: Overall, both methods allowed good visualization of anatomic structures. MIP was superior for visualization of the pulmonary arteries (p < 0.05) while central and peripheral bronchi and the lung parenchyma were better depicted on multiplanar reconstructions. A confident diagnosis of thoracic pathology was feasible using both modalities, however MIPs appeared less usefull for evaluation of gross parenchymal abnormalities, such as pneumonic infiltrates or fibrotic changes. No significant difference in the degree of motion artifacts were detected between both modalities. CONCLUSION: MSCT data sets are ideally suited for generating MPR and MIP reconstructions. While MIPs are superior for the evaluation of thoracic vessels, MPR is advantageous for visualizing central and peripheral bronchi and the pulmonary parenchyma.

Humans↗

Electrocardiographically gated thin-section CT of the lung.

PURPOSE: To determine whether electrocardiographic (ECG) gating improves image quality of thin-section computed tomographic (CT) scans of the lung obtained with a subsecond CT scanner. MATERIALS AND METHODS: Thin-section CT was performed in 35 patients by using standard techniques. Three additional sections were obtained in each patient with prospective ECG gating at corresponding levels of the paracardiac lung parenchyma. Non-ECG-gated and ECG-gated sections were then rated in blinded fashion by three experienced radiologists for overall image quality, spatial resolution, and diagnostic value and for different types of respiratory and cardiac motion artifacts. RESULTS: ECG gating helped significantly reduce artifacts caused by cardiac motion (i.e., distortion of pulmonary vessels, double images, or blurring of the cardiac border) (P < .05). ECG gating did not reduce respiratory motion artifacts. In patients with heart rates of less than 76 beats per minute, ECG gating significantly improved overall image quality (P = .041). ECG gating was not perceived to increase the diagnostic value of thin-section CT scans. CONCLUSION: ECG gating improves image quality of thin-section CT scans of the lung by reducing cardiac motion artifacts that may mimic disease. It must be established whether ECG gating can help increase the diagnostic accuracy of thin-section CT for the evaluation of subtle parenchymal disease.

Adult↗