The Heartmate III: design and in vivo studies of a maglev centrifugal left ventricular assist device.

A compact implantable centrifugal left ventricular assist device (LVAD) (HeartMate III) featuring a magnetically levitated impeller is under development. The goal of our ongoing work is to demonstrate feasibility, low hemolysis, and low thrombogenicity of the titanium pump in chronic bovine in vivo studies. The LVAD is based on so-called bearingless motor technology and combines pump rotor, drive, and magnetic bearing functions in a single unit. The impeller is rotated (theta z) and levitated with both active (X, Y) and passive (Z, theta x, theta y) suspension. Six prototype systems have been built featuring an implantable titanium pump (69 mm diameter, 30 mm height) with textured blood contacting surfaces and extracorporeal electronics. The pumps were implanted in 9 calves (< or = 100 kg at implant) that were anticoagulated with Coumadin (2.5 < or = INR < or = 4.0) throughout the studies. Six studies were electively terminated (at 27-61 days), 1 study was terminated after the development of severe pneumonia and lung atelectasis (at 27 days) another study was terminated after cardiac arrest (at 2 days) while a final study is ongoing (at approximately 100 days). Mean pump flows ranged from 2 to 7 L/min, except for brief periods of exercise at 6 to 9 L/min. Plasma free hemoglobin ranged from 4 to 10 mg/dl. All measured biochemical indicators of end organ function remained within normal range. The pumps have met performance requirements in all 9 implants with acceptable hemolysis and no mechanical failures.

Animals↗

The role of diastolic pump flow in centrifugal blood pump hemodynamics.

We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV-Ao) bypass, and parameters were recorded at different pump speeds under general anesthesia. Pump inflow and outflow pressure, arterial pressure, systemic and pulmonary blood flow, and electrocardiogram (ECG) were recorded on the computer every 5 ms. All parameters were separated into systolic and diastolic components and analyzed. The pulmonary flow was the same as the systemic flow during the study (p > 0.1). Systemic flow consisted of pump flow and LV output through the aortic valve. The ratio of systolic pump flow to pulmonary flow (51.3%) did not change significantly at variable pump speeds (p > 0.1). The other portions of the systemic flow were shared by the left ventricular output and the pump flow during diastole. When pump flow increased during diastole, there was a corresponding decrease in the LV output (Y = -1.068X + 51.462; R(insert)(2) = 0.9501). These show that pump diastolic flow may regulate expansion of the left ventricle in diastole.

Analysis of Variance↗

Continuously maintaining positive flow avoids endocardial suction of a rotary blood pump with left ventricular bypass.

This study showed the usefulness of maintaining positive pump flow to avoid endocardial suction and as an assist bypass. Three calves were implanted with centrifugal pumps. Hemodynamics and pump parameters were measured at varying pump speeds (from 1,100 to 2,300 rpm). In each test pump, speed was adjusted to create 3 hemodynamic states: both positive and negative flow (PNF), positive and zero flow (PZF), and continuously positive flow (CPF). The pump flow volume was determined during systole (Vs) and diastole (Vd). Vs in PNF was 29.6 ml and was not significantly different from Vs in PZF (p > 0.15). Vd in PNF was significantly different from Vd in PZF (p < 0.05). All bypass rates of PNF were over 30% of pulmonary flow. All PZF bypass rates were between the PNF rate and the CPF rate. These data showed that PZF satisfied the minimum requirement of assist flow and was under 100% bypass. Thus, PZF may avoid endocardial suction.

Analysis of Variance↗

Development of the Nimbus/University of Pittsburgh innovative ventricular assist system.

BACKGROUND: Nimbus Inc, and the University of Pittsburgh's McGowan Center for Artificial Organ Development have been collaborators on rotary blood pump technology initiatives since 1992. Currently, a major focus is an innovative ventricular assist system (IVAS) that features an implantable, electrically powered axial flow blood pump. In addition to the blood pump, a major development item is the electronic controller and the control algorithm for modulating pump speed in response to varying physical demand. METHODS: Methods used in developing the IVAS include computational fluid dynamic modeling of the pump's interior flow field, flow visualization of the flow field using laser-based imaging, computer simulation of blood pump-physiological interactions, vibroaccoustic monitoring, and an extensive in vivo test program. RESULTS: Results to date, which are presented below, include successful in vivo tests of blood pumps with blood-immersed bearings, and feasibility demonstration of vibroacoustic monitoring in this application. CONCLUSIONS: This unique blend of industrial experience and technologies with the University-based Research and Development Center has greatly enhanced the progress made on this IVAS project.

Animals↗

Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study.

Many types of rotary blood pumps and pump control methods have recently been developed with the goal of clinical use. From experiments, we know that pump flow spontaneously increases during exercise without changing pump control parameters. The purpose of this study was to determine the hemodynamics associated with the long-term observation of calves implanted with centrifugal blood pumps (EVAHEART, Sun Medical Technology Research Corporation, Nagano, Japan). Two healthy female Jersey calves were implanted with devices in the left thoracic cavity. A total of 22 treadmill exercise tests were performed after the 50th postoperative day. During exercise, the following parameters were compared with conditions at rest: heart rate, blood pressure, central venous oxygen saturation (SvO2), pump speed, and pump flow. The pump flow in a cardiac cycle was analyzed by separating the systole and diastole. Compared to the base data, statistically significant differences were found in the following interrelated parameters: the heart rate (66.8 +/- 5.2 vs. 106 +/- 9.7 bpm), mean pump flow (4.8 +/- 0.2 vs. 7.0 +/- 0.3 L/min), and volume of pump flow in diastole (26.0 +/- 1.8 vs. 13.5 +/- 2.5 ml). During exercise, the volume of pump flow in systole was 3 times larger than that measured in diastole. Blood pressure, SvO2, and pump speed did not change significantly from rest to exercise. These results suggested that the mean pump flow depends on the systolic pump flow. Therefore, the increase in the mean pump flow during exercise under constant pump speed was caused by an increase in the heart rate.

Animals↗

Flow cytometric assays to detect platelet activation and aggregation in device-implanted calves.

Cardiovascular device development often relies upon large-animal models to assess blood biocompatibility prior to initiating clinical trials. Unfortunately, the amount of information gleaned from such trials is limited by simple assays that do not take full advantage of immunotechnological advances that increasingly are applied in clinical studies. Thus we have developed and tested new flow cytometric techniques for measuring circulating activated bovine platelets and platelet microaggregates. Monoclonal antibodies (MAbs) raised against both activated and quiescent bovine platelets were incubated with control and PMA-or ADP-stimulated whole blood. Selected MAbs detected activated bovine platelets and platelet microaggregates in vitro with flow cytometry. Five calves implanted with one of two designs of nonpulsatile ventricular-assist devices (VADs) were followed with these assays prior to and during VAD implantation. Circulating activated bovine platelets and microaggregates increased after implantation in all animals and, alternatively, remained elevated or returned toward preimplant levels. Platelet activation percentages as detected temporally by three MAbs were correlated with one another, and platelet activation was correlated with microaggregate formation. In summary, these new methods for the sensitive measurement of circulating activated bovine platelets and microaggregates may provide valuable information for the development and assessment of future cardiovascular device designs.

Adenosine Diphosphate↗

Assessment of bovine platelet life span with biotinylation and flow cytometry.

Reduced platelet life span is associated with the implantation of a variety of cardiovascular devices and may be used as a gauge of device biocompatibility. In the bovine model, platelet life span has previously been assessed with radioisotope labeling of removed platelets followed by reinjection and periodic gamma counting of blood samples. We report here the use of protein-reactive biotin (sulfo-N-hydroxysuccinimido [NHS]-biotin) as an alternative to radioisotope techniques whereby reinjected biotinylated platelets are subsequently detected in blood samples using phycoerythrin-streptavidin and flow cytometric techniques. Platelet life span was quantified in a normal calf (4.9 days) and in a calf prior to (6.1 days) and following (3.1 days) implantation of a Nimbus Axial Flow Pump ventricular assist device. The assessment of bovine platelet life span with biotinylation and flow cytometry avoids the technical, regulatory, and safety considerations associated with radioisotope usage and appears readily amenable to application in cardiovascular device testing.

Animals↗

Fine trabecularized carbon: ideal material and texture for percutaneous device system of permanent left ventricular assist device.

The development of a percutaneous artificial internal organ system requires a reliable biocompatible connection between the external environment and the inside of the human body. Such is necessary for the success of a permanent left ventricular assist device. However, the search for a satisfactory interface at the epidermal level has proven to be difficult. Carbon has been proposed for this application, but its texture does not typically promote ingrowth from surrounding tissue. We have therefore employed a new processing method to produce a fine trabecularized carbon implant. The method for preparing the implant involves infiltrating low temperature pyrolytic carbon into the surface of a carbon core which is wrapped with carbon fabric. This results in a tightly woven porous structure of carbon (carbon fiber diameter: 35-50 microm, maximal pore size >200 microm) with gradually increasing porosity from 15-75%. We implanted test samples percutaneously in a calf for in vivo histological evaluation. Thirty days after implantation epidermal downgrowth was minimal. Microscopic analysis revealed that a thin fibrous capsule surrounded the implant, and mature connective tissue with accompanying blood vessels filled the pores of the fine trabecularized carbon layer. From these results we suggest that fine trabecularized carbon is ideally suited for a percutaneous device system in a permanent left ventricular assist device.

Animals↗

An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal system).

A compact centrifugal blood pump has been developed as an implantable left ventricular assist system. The impeller diameter is 40 mm, and pump dimensions are 55 x 64 mm. This first prototype, fabricated from titanium alloy, resulted in a pump weight of 400 g including a brushless DC motor. The weight of a second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon (DLC) to improve blood compatibility. Flow rates of over 7 L/min against 100 mm Hg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system (Cool-Seal) is used for the shaft seal. In this seal system, the seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. Purge fluid is continuously purified and sterilized by an ultrafiltration unit which is incorporated in the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular (LV) apex descending aorta bypass was performed utilizing an expanded polytetrafluoroethylene (ePTFE) vascular graft with the pump placed in the left thoracic cavity. In 2 in vivo experiments, the pump flow rate was maintained at 5-9 L/min, and pump power consumption remained stable at 9-10 W. All plasma free Hb levels were measured at less than 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (<0.5 ml/day). In both calves, the pumps demonstrated trouble free continuous function over 6 month (200 days and 222 days).

Alloys↗

Effect of pressure-flow relationship of centrifugal pump on in vivo hemodynamics: a consideration for design.

We have been developing centrifugal pumps for an implantable left ventricular assist device. We manufactured 2 prototype centrifugal pumps (PI, PII). These two have similar designs except for the PII having a volute casing and a large output port. To determine the differences in the hydraulic characteristics between the PI and PII, we carried out in vitro and in vivo experiments. In vitro study showed that the PII had a shallower H-Q curve than that of the PI, and the PII required a pump speed faster than the PI for the same flow rate and pressure head. On the other hand, in vivo study showed that the PII demonstrated a flow pulsatility greater than that of the PI at 1,900 rpm and 8 L/min although no significant change was observed at low pump speeds (< or = 1,500 rpm). This greater pulsatility consisted of a large discharge according to the small differential pressure during the systolic phase and a small discharge according to the large differential pressure during the diastolic phase. In contrast, the PI, having the steeper H-Q curve, showed a small discharge in the systolic phase and a large discharge in the diastolic phase. These results showed that pulsatility synchronized with the native heart beating depended on the slope of the H-Q curve. As a result, the slope of the H-Q curve is important to determine the component of pulsatility synchronized with native cardiac output. Regarding the slope of the H-Q curve, a pump having a volute casing and a large outlet port demonstrates a shallow slope in the H-Q curve. In conclusion, we suggest that a centrifugal pump for use in left ventricular aortic bypass should be designed considering the effect on the native heart pulsatility.

Animals↗

Development of the Nimbus/Pittsburgh axial flow left ventricular assist system.

Nimbus, Inc. and the University of Pittsburgh's School of Medicine have been collaborators developing rotary blood pump technology since 1992. Currently, a major focus is on an implantable left ventricular assist system (LVAS) that utilizes an electric powered axial flow blood pump. In addition to the blood pump, a major development item is the electronic controller and the control algorithm for modulating the pump speed in response to varying physiologic demands. Methods being used in developing the axial flow LVAS include the use of computational fluid dynamic modeling of the interior flow field of the pump, flow visualization of the flow field using laser based imaging, and computer simulation of blood pump-physiological interactions as well as an extensive in vivo test program. Results to date include successful in vivo tests of blood pumps with nonlubricated bearings and demonstrations of auto speed control using electrical current as the observable parameter.

Algorithms↗

Development and initial testing of a pediatric centrifugal blood pump.

BACKGROUND: We are developing a miniaturized centrifugal blood pump for use as a temporary cardiac assist device in neonatal and pediatric sized patients. This pump has a very low priming volume of 13 mL. A small motor stator has also been designed, which resulted in a device that can be placed very close to the patient, thereby minimizing overall circuit volume. METHODS: Testing to date has included in vitro hemodynamic performance, in vitro hemolysis generation, and in vivo evaluation in 5 lambs weighing 5.5 to 21 kg. Two lambs underwent peripheral cannulation from external jugular vein to carotid artery, whereas 3 others were cannulated from left atrium to carotid artery. RESULTS: In vitro data demonstrated pump capacity spanning 0.3 to 3.0 L/min and very low hemolysis generation at these conditions. In vivo, the pump functioned satisfactorily for periods up to 148 hours, and the bypass appeared to be well tolerated by the animals. Plasma free hemoglobin levels remained less than 25 mg/dL during all animal experiments. All devices were thrombus-free at explantation. CONCLUSIONS: We conclude that this device has merit as an alternative to current oversized systems used for neonatal and pediatric cardiac assistance. In addition, a chronic neonatal lamb model in which to evaluate pediatric circulatory assist devices has been developed successfully.

Animals↗

Long-term animal survival with an implantable axial flow pump as a left ventricular assist device.

We are developing an axial flow blood pump with Nimbus Inc. (AxiPump). For in vivo evaluation the AxiPump has been used as a left ventricular assist device with a left ventricular and descending aorta cannulation and implantation in a small pocket on the left lateral abdominal wall just posterior to the costal margin. Electrical and flow probe leads exit the body transcutaneously. A purge line that delivers the purge fluid for lubrication of the seal between the rotor and stator bodies in the purge fluid bearing system is tunneled with the other leads. Following acute animal studies, 3 animals have been supported for over 1 month with this AxiPump system. All laboratory results were within normal limits except during a recovery period from surgical damage. Hemolysis was not a serious problem. In the first case, the purge system failed at 28 days, and in the second and third cases, the nonpurge bearing system worked well for 57 and 52 days, respectively. Bearings are still under development in this kind of pump. However, this success encourages us to improve the AxiPump as a long-term assist device.

Animals↗

Controller for an axial flow blood pump.

A rotary blood pump inherently provides only one noninvasive "observable" parameter (motor current) and allows for only one "controllable" parameter (pump speed.) To maintain the systemic circulation properly, the pump seed must be controlled to sustain appropriate outlet flows and perfusion pressure while preventing pulmonary damage caused by extremes in preload. Steady-state data were collected at repeated intervals during chronic trials of the Nimbus AxiPump (Nimbus, Inc., Rancho Cordova, California, U.S.A.) in sheep (n = 7) and calves (n = 12). For each data set, the pump speed was increased at increments of 500 rpm until left ventricular and left atrial emptying was observed by left atrial pressure diminishing to zero. The effect of decreasing preload was evaluated perioperatively by inferior vena cava occlusion at a constant pump speed. Fourier analysis established a relationship between changes in the pump preload and the power spectra of the pump current waveform. Based on these results, a control method was devised to avoid ventricular collapse and maintain the preload within a physiologic range. The objective of this controller is the minimization of the second and third harmonic of the periodic current waveform. This method is intended to provide a noninvasive regulation of the pump by eliminating the need for extraneous transducers.

Animals↗