PubMed Health⌕ Search

Biomedical subjects

P M Dummer

Publications and source records attributed to P M Dummer.

At least 19 recordsLinked to original sources

The outcome of root canal treatment. A retrospective study within the armed forces (Royal Air Force).

OBJECTIVE: The objective of this study was to investigate the outcome of conventional root canal treatment in a general practice setting within the Royal Air Force dental service. Design Retrospective review. METHODS: Teeth that had been root-filled for 12 months or more by Royal Air Force dental practitioners in patients attending a large Royal Air Force dental centre were included in the study. Following clinical and radiographic review the root fillings were classified as 'definitely successful', 'probably successful' or 'failed' The effect on success of several variables on the outcome was investigated. RESULTS: Out of a total of 406 teeth, 59% were maxillary teeth and 41% were mandibular teeth. Sixty-nine per cent of the total sample had pre-existing periapical radiolucencies. Cold lateral condensation of gutta-percha was the most widely used filling technique (64% of all cases). Fifty per cent of the teeth had root fillings within 2 mm of the radiographic apex, 32% were greater than 2 mm from the radiographic apex and 18% were overfilled. Cold lateral condensation was the most successful (92% overall) filling technique. Maxillary anterior teeth had a better success rate (96%) than other tooth types. Teeth with pre-existing periapical radiolucencies had a higher success rate (87%) than those cases where there was no pre-existing periapical radiolucency (80%). Root fillings that were less than 2 mm from the radiographic apex of the tooth had a higher success rate (88% overall) than those that were greater than 2 mm from the radiographic apex (77% overall). Of the 406 cases, 57% (n=231) were classified as definitely successful, 28% (n=114) were classified as probably successful and 15% (n=62) were classified as failures. Thus, the overall success rate combining definitely successful and probably successful root fillings was 85% (n=344). CONCLUSIONS: Root fillings placed using cold lateral condensation of gutta-percha to within 2 mm of the radiographic apex of the tooth were associated with the best outcome.

Administration, Topical↗

A study of endodontic treatment carried out in dental practice within the UK.

AIM: The purpose of this study was to gather both qualitative and quantitative information on the nature of root canal treatment carried out by a group of dentists working within the United Kingdom. METHODOLOGY: A two-part questionnaire was posted to 720 dentists who graduated from the Dental School, Cardiff, Wales, UK. The first part requested basic information regarding age, year of qualification, field of practice, etc. The second part consisted of 15 questions on endodontic practice and root canal treatment. RESULTS: The response rate was 41.5%. Two hundred and ninety-nine questionnaires contained useful information. The majority of practitioners did not use rubber dam during root canal treatment. The vast majority (89%) exposed a radiograph with an instrument of known length in situ to gauge the 'working length', a small number relied upon tactile sensation. Most practitioners used local anaesthetic solution as an irrigant during instrumentation of the root canal. A wide variety of instruments were used for root canal treatment; a stepback technique was preferred by almost half the practitioners. Antiseptic solution was preferred as an interappointment dressing. More than half of the respondents used laterally condensed gutta-percha to obturate root canals in anterior teeth but only one-third used the same technique in posterior teeth. Less than half the respondents exposed a radiograph to check the fit of the master point prior to obturation. Two-thirds of practitioners used a zinc oxide based material as their root canal sealer. Three-quarters of the practitioners exposed a post obturation radiograph. CONCLUSIONS: The results of this study suggest that although some dentists are using the techniques taught during their undergraduate careers, a large percentage now use techniques with no evidence of clinical effectiveness.

Adult↗

Canal shapes produced sequentially during instrumentation with Quantec SC rotary nickel-titanium instruments: a study in simulated canals.

AIM: The aim of this study was to determine the shaping ability of Quantec SC nickel-titanium rotary instruments in simulated root canals. METHODOLOGY: Forty simulated canals consisting of four different shapes in terms of angle and position of curvature were prepared with Quantec SC instruments. Sequential still images were taken of the canals using a video camera attached to a computer with image analysis software. Images were taken preoperatively, and then after instrument 7 (Size 25, 0.05 taper), instrument 8 (size 25, 0.06 taper), and instrument 10 (size 45, 0.02 taper) were taken to length. Each sequential postoperative image was superimposed individually over the preoperative image in order to highlight the amount and position of material removed during preparation. RESULTS: Overall, the mean preparation time to size 10 was 3.6 min with 12 mm canals taking on average less time than 8 mm canals. There was a highly significant difference between the canal types (P < 0.0001). No instruments fractured within the canal or deformed, although one instrument separated from the latch grip. All canals remained patent. Following preparation to size 10, 19 canals (48%) retained their length, eight (20%) lost length, and 13 (32%) gained length; the magnitude of the change in length was always 0.5 mm or below. Following preparation to size 7 instruments all canals showed aberrant shapes. Excess removal of material along the outer aspect of the curve between the beginning of the curve and the end-point (outer widening) was found in 26 canals (65%) after instrument 7. At the same stage of preparation six canals (15%) had zips, three (8%) had ledges and five (13%) had perforations. Following preparation to size 10, 27 (68%) canals were perforated. CONCLUSIONS: Under the conditions of the study, Quantec SC instruments consistently produced aberrations when canals were enlarged to size 7 (size 25, 0.05 taper) or above. Care should be exercised when using these instruments in real teeth.

Dental Alloys↗

An audit of root canal treatment performed by undergraduate students.

AIM: The objective of this study was to audit the quality of root canal treatment performed by undergraduate students on adult patients. METHODOLOGY: All root canal treatment completed by first and second clinical year undergraduates over a 12-month period were included in the study. The availability and readability of pretreatment, diagnostic length, try-in point and postoperative radiographs were noted for each case. All readable postoperative radiographs of primary treatments were examined for quality of the root filling, categorized as complete, incomplete apical, incomplete apical and lateral or not assessable. The distance from the radiographic apex of the root to the apical extent of each root filling was measured to 0.1 mm precision. RESULTS: Undergraduates performed primary treatment on 157 teeth. A postoperative radiograph was available in 97% of cases. A try-in point radiograph was unavailable in one-fifth of cases. Twenty-seven teeth (13%) were categorized as satisfactory in terms of both radiographic quality and distance of the root filling from the radiographic apex. CONCLUSIONS: Overall, the technical quality of root canal treatment completed by undergraduate students was poor.

Adult↗

Comparison of lateral condensation and thermomechanically compacted warm alpha-phase gutta-percha with a single cone for obturating curved root canals.

OBJECTIVE: To evaluate and compare the sealability and radiographic quality of root fillings in extracted teeth by using lateral condensation of gutta-percha or alpha-phase gutta-percha in conjunction with a single gutta-percha cone. STUDY DESIGN: A total of 108 single-rooted teeth were divided into 2 groups of 54 teeth based on canal shape. Canals were prepared to a minimum 0.055 taper and enlarged to a size 35 at the working distance. Irrigation was done with 17% EDTA and 2.5% sodium hypochlorite (NaOCl) to remove smear layer. One group was obturated by using cold lateral condensation of gutta-percha; the other group was obturated with thermomechanically compacted alpha-phase gutta-percha and a single cone of gutta-percha. Apical extrusion of sealer or gutta-percha was recorded. Sealability of each technique was assessed by dye penetration. The radiographic quality of obturation was also determined. RESULTS: Root canals filled with alpha-phase gutta-percha and a single cone had significantly more extrusion of sealer than canals filled by lateral condensation. Lateral condensation achieved significantly better scores for radiographic quality. There was no significant difference between the 2 filling techniques in terms of apical or coronal leakage. CONCLUSIONS: Thermomechanically condensed alpha-phase gutta-percha used in conjunction with a single gutta-percha cone had poorer radiographic quality than laterally condensed gutta-percha.

Dental Leakage↗

Ribbon dentistry.

Explore the source record for details and available documents.

Artifacts↗

Evaluation of the Trifecta obturating technique.

The aim of this project was to evaluate and compare the radiographic quality and sealability of root fillings in extracted human teeth using lateral condensation of gutta-percha or the Trifecta obturating system. One hundred freshly extracted human mature, single-rooted teeth were divided into four identical groups of 25 teeth on the basis of root canal shape. The root canals of two groups were prepared in such a way as to produce a relatively parallel canal shape with little or no flare towards the coronal orifice. The root canals of the other two groups were prepared in such a way as to produce a canal shape that was deliberately more flared to ensure that they were wider at the orifice than at the endpoint of the preparation. All root canals were flushed with 17% EDTA solution and 2.5% NaOCl to remove the dentinal smear layer. The canals of one flared and one parallel group were obturated using cold lateral condensation and the canals of the other two groups were obturated using the Trifecta system. The sealability of each technique was assessed by a dye penetration method. The radiographic quality of obturation was determined for each canal using a 4-point scale. Canals filled with thermoplasticised gutta-percha had significantly less apical dye penetration than those obturated by lateral condensation (P < 0.001). Lateral condensation achieved significantly better scores for radiographic quality than thermoplasticised gutta-percha from both the bucco-lingual (P < 0.001) and the mesio-distal views (P < 0.001). Root canals obturated using the Trifecta technique showed significantly more apical extrusion of sealer than those obturated by lateral condensation (P < 0.001). Under laboratory conditions the Trifecta technique had better sealability but poorer radiographic quality than lateral condensation.

Dental Leakage↗

Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: Part 1.

AIM: To determine the general efficacy and shaping ability of Hero 642 nickel-titanium rotary instruments during the preparation of simulated canals. Part 1 of this two-part report describes the efficacy of the instruments in terms of three-dimensional canal form. METHODOLOGY: A total of 40 simulated root canals made up of four different shapes in terms of angle and position of curvature were prepared by Hero 642 instruments using a crown-down preparation sequence. The efficacy of the instruments was assessed in terms of preparation time, instrument failure, canal blockages and loss of canal length. Intra-canal impressions were taken of the prepared canals in order to assess three-dimensional canal form. RESULTS: The mean time for canal preparation was 8.6 min and was influenced significantly (P < 0.05) by canal shape. Two instruments fractured and eight instruments deformed; significant differences were observed between canal shapes (P < 0.05). All of the canals remained patent. Fifteen canals (39.5%) maintained the correct working distance, 15 lost distance and eight canals gained length. Examination of intracanal impressions demonstrated that the majority of canals (79%) had apical stops; canal shape had a significant influence (P < 0.001) on the quality of apical stops. With one exception all canals had smooth canal walls and all of the canals showed good flow characteristics. Taper was poor in 30 canals (79%) and good in eight canals (21%). CONCLUSIONS: Hero 642 rotary nickel-titanium instruments prepared simulated canals rapidly but with a three-dimensional form that lacked adequate taper.

Dental High-Speed Equipment↗

Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: Part 2.

AIM: To determine the shaping ability of Hero 642 nickel-titanium rotary instruments during the preparation of simulated canals. METHODOLOGY: A total of 40 simulated root canals made up of four different shapes, in terms of angle and position of curvature, were prepared by Hero 642 instruments using a crown-down preparation sequence. Pre- and postoperative images of the canals were taken using a video camera attached to a computer with image analysis software. The pre- and postoperative views were superimposed to highlight the amount and position of material removed during preparation. This report describes the efficacy of the instruments in terms of prevalence of canal aberrations, the amount and direction of canal transportation and overall postoperative shape. RESULTS: Four zips and four elbows were created during preparation, all in canals with 40 degrees, 12 mm curves. No perforations or danger zones were created. Highly significant differences (P < 0.001) were apparent between the canal shapes in total canal width at the apex and beginning of the curve, and in the amount of resin removed from the inner and outer aspects of the curve at the orifice. Canal transportation was most frequently directed toward the outer aspect of the curve at specific points along the canal, except at the orifice, where it was apparent that canals with 20 degrees curves transported toward the inner. Overall, mean absolute transportation was always less than 0.15 mm; however, significant differences occurred between canal shapes at the end-point (P < 0.01), apex of the curve (P < 0.01) and at the orifice (P < 0.01). CONCLUSIONS: Under the conditions of this study, Hero 642 rotary nickel-titanium instruments created canals with few aberrations and no perforations. The relatively high proportion of aberrations in canals with short, acute curves may indicate that instruments with increased taper should be used with caution at or near the full working distance. Further research in real teeth is necessary to elucidate the full potential of these new rotary instruments for use in root canal preparation.

Dental High-Speed Equipment↗

Canal shapes produced sequentially during instrumentation with Quantec LX rotary nickel-titanium instruments: a study in simulated canals.

AIM: The aim of this study was to determine the shaping ability of Quantec LX nickel-titanium rotary instruments in simulated root canals. METHODOLOGY: Forty simulated canals consisting of four different shapes in terms of angle and position of curvature were prepared with Quantec LX instruments. Sequential still images were taken of the canals using a video camera attached to a computer with image analysis software. Images were taken preoperatively; after, instrument 7 (Size 25, 0.05 taper), instrument 8 (size 25, 0.06 taper), and instrument 10 (size 45, 0.02 taper) were taken to length. Each sequential postoperative image was superimposed individually over the preoperative image in order to highlight the amount and position of material removed during preparation. Intra-canal impressions after preparation to size 10 were taken to evaluate three-dimensional canal form. RESULTS: Overall, the mean preparation time to size 10 was 4.7 min; canal shape did not have a significant effect on speed of preparation. No instruments fractured within the canal, but 7 instruments separated from the latch grip, and a further 3 instruments deformed. All canals remained patent. Following preparation to size 10, 29 canals (72%) retained their length, 7 (17%) lost length, and 4 gained length; the magnitude of the change in length was always below 1 mm. Zips were created in 3 canals (7%) after use of size 10 instruments, but no perforations or danger zones were produced. Excess removal of material along the outer aspect of the curve between the beginning of the curve and the end-point (outer widening) was found in 22 canals (55%) after instrument 7, in 30 (75%) canals after size 8 and in 35 canals (88%) after size 10. There was a significant difference (P < 0.0001) between canal shapes for the incidence of this aberration at all sizes. CONCLUSIONS: Under the conditions of the study, Quantec LX instruments tended to remove excess material from the outside of the curve between the beginning of the curve and the end-point. These aberrations increased in prevalence and severity following the use of larger instruments when they were taken to length. Size 8, 9 and 10 Quantec LX instruments should be used with care and short of length, especially in severely curved canals.

Analysis of Variance↗

Comparison of cold lateral condensation and a warm multiphase gutta-percha technique for obturating curved root canals.

AIM: The aim of this project was to evaluate and compare the radiographic quality and sealability of root fillings in extracted human teeth using lateral condensation of gutta-percha or multiphase gutta-percha obturation (Alphaseal). METHODOLOGY: A total of 108 freshly extracted human, mature single-rooted teeth were divided into two identical groups of 54 teeth on the basis of root canal shape. The canals were prepared to a minimum 0.055 taper and enlarged to size 35 at the apex. All root canals were flushed with 17% EDTA solution and 2.5% NaOCl to remove the dentinal smear layer. The canals of one group were obturated using cold lateral condensation of gutta-percha and the canals of the other group were filled using a warm multiphase gutta-percha obturation technique. The extrusion of sealer and/or gutta-percha through the apex of the teeth was recorded using a simple yes/no scheme. The sealability of each technique was assessed by a dye penetration method. The radiographic quality of obturation was determined for each canal using a four-point scale. RESULTS: Root canals filled by multiphase obturation had significantly more extrusion of sealer (P < 0.001) and gutta-percha (P < 0.001) than canals filled by lateral condensation. Canals filled by multiphase gutta-percha obturation had significantly less apical dye leakage than those obturated by lateral condensation (P < 0.05). Lateral condensation achieved significantly better scores for radiographic quality than multiphase obturation from the bucco-lingual view (P < 0.01). CONCLUSIONS: Under laboratory conditions multiphase gutta-percha had better sealability but poorer radiographic quality than lateral condensation.

Composite Resins↗

Cleaning effectiveness of root canal irrigation with electrochemically activated anolyte and catholyte solutions: a pilot study.

AIM: The aim of this study was to evaluate the potential of electrochemically activated (ECA) anolyte and catholyte solutions to clean root canals during conventional root canal preparation. METHODOLOGY: Twenty extracted single-rooted human mature permanent teeth were allocated randomly into four groups of five teeth. The pulp chambers were accessed and the canals prepared by hand with conventional stainless steel endodontic instruments using a double-flared technique. One or other of the following irrigants was used during preparation: distilled water, 3% NaOCl, anolyte neutral cathodic (ANC) (300 mg L-1 of active chlorine), and a combination of anolyte neutral cathodic (ANC) (300 mg L-1 of active chlorine) and catholyte. The teeth were split longitudinally and the canal walls examined for debris and smear layer by scanning electron microscopy. SEM photomicrographs were taken separately in the coronal, middle and apical parts of canal at magnification of x800 to evaluate the debridement of extracellular matrix and at a magnification of x2500 to evaluate the presence of smear layer. RESULTS: Irrigation with distilled water did not remove debris in the apical part of canals and left a continuous and firm smear layer overlying compressed low-mineralized predentine. All chemically active irrigants demonstrated improved cleaning potential compared to distilled water. The quality of loose debris elimination was similar for NaOCl and the anolyte ANC solution. The combination of anolyte ANC and catholyte resulted in improved cleaning, particularly in the apical third of canals. The evaluation of smear layer demonstrated that none of the irrigants were effective in its total removal; however, chemically active irrigants affected its surface and thickness. Compared to NaOCl, the ECA solutions left a thinner smear layer with a smoother and more even surface. NaOCl enhanced the opening of tubules predominantly in the coronal and middle thirds of canals, whereas combination of ANC and catholyte resulted in more numerous open dentine tubules throughout the whole length of canals. CONCLUSIONS: Irrigation with electrochemically activated solutions cleaned root canal walls and may be an alternative to NaOCl in conventional root canal treatment. Further investigation of ECA solutions for root canal irrigation is warranted.

Chlorine↗

Comparison of laterally condensed and low-temperature thermoplasticized gutta-percha root fillings.

The aim of this study was to evaluate and compare the radiographic quality and sealability of root fillings in extracted human teeth using lateral condensation of gutta-percha or low-temperature thermoplasticized gutta-percha (Ultrafil). One hundred freshly extracted human, mature single-rooted teeth were divided into four identical groups of 25 teeth on the basis of root canal shape. The root canals of two groups were prepared in such a way to produce a relatively parallel shape with little or no flare toward the coronal orifice. The root canals of the other two groups were prepared in such a way as to produce a canal shape that was deliberately more flared to ensure that they were wider at the orifice than at the end point of the preparation. All root canals were flushed with 17% EDTA solution and 2.5% NaOCl to remove the dentinal smear layer. The canals of one flared group and one parallel group were obturated using cold lateral condensation, and the canals of the other two groups were obturated using low-temperature thermoplasticized gutta-percha. The sealability of each technique was assessed by a dye penetration method. The radiographic quality of obturation was determined for each canal using a 4-point scale. Canals filled with thermoplasticized gutta-percha had significantly less apical dye penetration than those obturated by lateral condensation (p < 0.001). Lateral condensation achieved significantly better scores for radiographic quality than thermoplasticized gutta-percha from both the buccolingual (p < 0.005) and mesiodistal views (p < 0.001). Low-temperature thermoplasticized gutta-percha root fillings were associated with significantly more apical extrusion of sealer (p < 0.001) and gutta-percha (p < 0.005). Under laboratory conditions the low-temperature thermoplasticized gutta-percha had better sealability but poorer radiographic quality than lateral condensation.

Chelating Agents↗

Clinical problems associated with unusual cases of talon cusp.

CASE REPORT: Talon cusp is an uncommon dental anomaly manifested as an accessory cusp-like structure on the crown of anterior teeth. This report describes two unusual cases of talon cusp. Case 1 showed bilateral anomalous cusps on the palatal aspects of maxillary supernumerary teeth, causing premature contact and tooth impaction. In case 2, a double-fused talon cusp was projected from the palatal surface of a large geminated central incisor. A talon cusp is not an innocuous defect, as it may provide a substantial diagnostic, treatment planning and procedural challenge. Early diagnosis and management are important to avoid complications.

Adolescent↗

Preclinical endodontology: an international comparison.

AIM: The aim of this study was to compare preclinical endodontic teaching in Europe, Scandinavia and North America, and to place recent UK data in an international context. METHODOLOGY: A postal questionnaire was sent to all undergraduate dental schools in North America, Scandinavia, and Europe. Data were requested on a range of issues relating to endodontic teaching. RESULTS: Forty-three percent of the 170 schools surveyed returned completed questionnaires. There was considerable international consensus on the content of preclinical courses, with most schools advocating preflaring canal preparation techniques, sodium hypochlorite for irrigation, and cold lateral condensation as the standard obturation method. There was little consensus on the standard use of intracanal medicaments, though calcium hydroxide was universally popular. The practice of single visit treatment was advocated by at least 70% of schools in all geographical areas. A number of innovations appear to be gaining acceptance in preclinical teaching, with more than 20% of schools teaching the use of electronic apex locators, and a quarter of Western European, Scandinavian and North American schools embracing nickel-titanium instrumentation. Regional differences in the priority and resource given to endodontic teaching were striking. On average, UK schools had the worst staff:student ratios for preclinical endodontic teaching, and allocated substantially less time allocation for this teaching compared with Western European, Scandinavian and North American schools. CONCLUSIONS: It was concluded that although teachers in the UK were broadly advocating techniques recommended elsewhere, the academic infrastructure and priority given for endodontic teaching in the UK was limited in the international context. This may have some impact on the quality of endodontic provision within the UK General Dental Services.

Curriculum↗

Shaping ability of .04 and .06 taper ProFile rotary nickel-titanium instruments in simulated root canals.

AIM: The aim of this study was to determine the shaping ability of ProFile .04 and .06 taper rotary nickel-titanium instruments in simulated canals. METHODOLOGY: A total of 40 simulated root canals made up of four different shapes in terms of angle and position of curvature were prepared using the 'crowndown' approach recommended by the manufacturer. Pre-operative pictures of each canal were recorded on optical discs using an image analysis package. The simulated canals were prepared and postoperative pictures superimposed on the original images. RESULTS: No instrument fractures occurred and none deformed; none of the canals became blocked with debris. Change in working distance was, on average, 0.063 mm with 33 canals retaining the correct length. Overall, five zips (12.5%) were created and 24 (60%) canals demonstrated a widened area on the outer aspect of the canal between the end-point and the curve. Two danger zones (5%) were created and two perforations but no ledges were found. Between canal shapes there were highly significant differences (P < 0.0001) for the incidence of zips and elbows but not for the other aberrations. There were highly significant differences (P < 0.0001) for the total width of the canals between the various canal shapes at the apex of the curve, the beginning of the curve and half way to the orifice, and a significant difference (P < 0.05) at the end-point. There were highly significant differences (P < 0.0001) for the amount of resin removed from the outer aspect of the curve at the end-point and at the beginning of the curve, and significant differences (P < 0.05) at the apex of the curve and half way to the orifice. There were highly significant differences (P < 0.0001) for the amount of resin removed from the inner aspect of the curve at the beginning of the curve and half way to the orifice. Overall, transportation was towards the outer aspect of the canal except at the beginning of the curve. CONCLUSIONS: Under the conditions of this study the combined use of .04 and .06 taper ProFile instruments was rapid, effective and produced good canal shapes except in those specimens with short curves that began near the end-point.

Dental High-Speed Equipment↗

The effect of alterations in horizontal X-ray beam angulation and bucco-lingual cavity width on the radiographic depth of approximal cavities.

The effects of changes in horizontal X-ray beam angulation and different cavity shape on images of approximal cavities on bite-wing radiographs were examined using a laboratory model. Cylindrical-, rectangular- and cone-shaped bur cut cavities were prepared in the approximal surfaces of 108 teeth and their depth determined using silicone putty impressions. Spatial relationships were controlled by fixing specimens into perspex blocks. Standardized radiographs were taken at baseline (0 degree) and then using pre-angled wedges to imitate horizontal X-ray beam movements of 5, 10 and 15 degrees in both mesial and distal directions. Radiographic cavity depth to the nearest 0.1 mm was measured. Over the range of X-ray beam movements, more than 72% of cavities deepened compared to baseline. As bucco-lingual cavity width increased the magnitude of the depth change increased. For some cylindrical cavities increases equating to 200% over baseline were seen; in some rectangular cavities increases of up to 400% over baseline occurred. The present study suggests that changes in irradiation geometry from baseline are likely to result in a cavity appearing to deepen. In a clinical context over-treatment is therefore the most likely outcome.

Dental Caries↗