Quantitative density profiling with pure phase encoding and a dedicated 1D gradient.

A new centric scan imaging methodology for density profiling of materials with short transverse relaxation times is presented. This method is shown to be more robust than our previously reported centric scan pure phase encode methodologies. The method is particularly well suited to density imaging of low gyro-magnetic ratio non-proton nuclei through the use of a novel dedicated one-dimensional magnetic field gradient coil. The design and construction of this multi-layer, water cooled, gradient coil is presented. Although of large diameter (7.62 cm) to maximize sample cross section, the gradient coil has an efficiency of several times that offered by conventional designs (6 mT/m/A). The application of these ideas is illustrated with high resolution density-weighted proton (1H) images of hazelnut oil penetration into chocolate, and lithium ion (7Li) penetration into cement paste. The methods described in this paper provide a straightforward and reliable means for imaging a class of samples that, until now, have been very difficult to image.

Cacao↗

A novel high temperature 1H NMR imaging probe for combustion studies: the behaviour of both a lit and unlit methane gas jet.

The design of a NMR probe suitable for very high temperature samples is described. The loop gap resonator is water cooled and tuned to 100 MHz for use in a 2.4 T horizontal bore magnet. The probe has been specifically designed for imaging of the combustion process. An experiment is described in this paper which shows the behaviour of a methane gas jet when both lit and unlit. The jet of gas may be observed in its unlit state flowing at up to 2 ms(-1) from a 1 mm diameter orifice using a Single Point Imaging technique. Images of the lit gas show loss of nuclear polarisation within 3 mm of the orifice. A residual amount of un-decomposed gas is visible in the first few millimetres of the flame neck. A computational fluid dynamics model is used to verify the distribution of molecular methane, as well as the temperature of the flame.

Journal Article↗

An optical method for three-dimensional dosimetry.

Accurate determination of the spatial distribution of the absorbed dose of ionising radiation plays an important role in radiotherapy, industrial radiation processing and many other applications. Computer calculations have frequently been used to estimate three-dimensional (3D) dose distributions in complex geometries and it becomes important to validate these by accurate 3D measurements. For this purpose we have been investigating the use of gelatin gels loaded with a modified Fricke solution which are pale orange in appearance and which, upon irradiation, become increasingly purple when viewed in normal light. This ferrous sulphate xylenol orange in gelatin gel (FXG) system displays very good properties, such as sensitivity, linearity and dynamic range, that make it suitable for 3D dosimetry applications. A high-speed optical tomography readout technique has been developed enabling two-dimensional projections of optical absorption data to be recorded rapidly. From these data the 3D absorbed dose distribution can quickly be derived with minimal degradation due to ion diffusion.

Color↗

A novel high-gradient permanent magnet for the profiling of planar films and coatings.

The design and construction of a low-cost, permanent magnet is described. The magnet is intended for applications which require a large static gradient, such as those for which stray field imaging or fringe field diffusometry are conventionally employed. The magnet has been designed using the scalar potential method. Particular features of the magnet include a field profile such that ||B || is constant in the horizontal plane and such that B is horizontal at the midpoint between the poles. There is a vertical, and therefore orthogonal, strong gradient, G, in ||B ||. The ratio G/ ||B || is constant within a large volume and so allows measurements at a range of gradient strengths. It is this ratio which governs the shape of the pole-pieces. The constructed magnet has a typical operating field of 0.8 T, gives a gradient of 20 Tm-1, and has a useable interpole access of 20 mm. Field plot data show values consistent with the theory. In particular ||B || has a curvature of less than +/-5 microm over a 5 x 5 mm area at the target field. The magnet is most suitable for the one-dimensional profiling of thin planar samples. As an example of the magnet's use, a profile of a sandwich structure made of several polymer layers is shown. In addition, a set of one-dimensional profiles of an alkyd coating, recorded during solvent loss and cross-linking, is presented. This example demonstrates quantitative T2 measurements at a resolution of 6.5 microm across a 70-microm-thick film.

Magnetic Resonance Spectroscopy↗

Sound generation in gradient coil structures for MRI.

When supporting plates of plastic material are subjected to alternating transverse Lorentz forces while in a strong magnetic field normal to the plate surface, compressional waves within the solid produce a modulation of the plate surface that launches an acoustic wave in air along the magnetic field axis. We have extended our previous theory describing this process to include a detailed description of the formation of an acoustic interference pattern in air described by Fraunhofer diffraction at a distance from the plate surface. The extended theory predicts that the observed acoustic signal midpoint and normal to the plate surface gives a variation with frequency in approximate agreement with our previous measurements. The acoustic output off axis shows acoustic blazing that produces two main diffraction peaks with a splitting inversely proportional to the velocity of sound in the plate material. The new results could have important ramifications for the minimization of sound output in gradient coil design for MRI. A new arrangement of coils is proposed to ameliorate the acoustic output problem centrally and normal to the plate by extending the frequency response of the supporting plates to much higher frequencies. Also presented are estimates of the compressional wave velocities deduced from frequency response data recorded at the center-point of a number of different plates.

Magnetic Resonance Imaging↗

A robust single-shot partial sampling scheme.

A method of reducing the amount of data required to reconstruct an image is described. In this scheme, fully sampled low spatial frequency data are acquired up to a given cutoff frequency and above this point, only alternate lines are sampled. Two images are produced, one of low definition and one of high definition but aliased. The proposed algorithm unwraps the aliased data, which are then used to enhance the low pass image, yielding a best estimate of the true image. The reduced sampling technique is shown to afford biological images that are almost indistinguishable from those obtained from a complete data set.

Algorithms↗

A microscope slide probe for high resolution imaging at 11.7 Tesla.

We present details of a novel RF coil for use in NMR microscopy. This coil is an inductively coupled surface coil which is built into a standard microscope slide. The coil is highly sensitive and is also designed so that the sample to be imaged can be viewed under an optical microscope. This facility allows comparison of optical and NMR micrographs, as well as accurate sample positioning. Using the slide coil, images of onion epidermal cells with an in-plane resolution of 4.5 microns have been produced.