PubMed HealthSearch

Biomedical subjects

P Mainil-Varlet

Publications and source records attributed to P Mainil-Varlet.

4 recordsLinked to original sources

Sterility, mechanical properties, and molecular stability of polylactide internal-fixation devices treated with low-temperature plasmas.

The effect of low-temperature plasma on sterility, molecular, mechanical, and crystalline properties of poly (L-lactide), poly (L/D-lactide) and poly (L/DL-lactide) was investigated. Polymers were treated for 15 and 30 min at 100 W with nitrogen, argon, oxygen, and carbon dioxide plasma. All polymers treated with oxygen or carbon dioxide plasma were rendered sterile after 15 min of treatment. Only 70% of the samples treated under similar conditions with nitrogen or argon plasma were sterile. Extension of the exposure time to 30 min and increasing power to 200 W did not improve sterilization efficiency. Plasma sterilization, under the conditions used, caused no significant decrease or increase in overall molecular weight or polydispersity of the polylactides used. In most instances the effect of plasma sterilization was to slightly increase the overall molecular weight of the polymers studied. Treatment with argon plasma led to a more consistent increase in molecular weight than did treatment with nitrogen, oxygen, or carbon dioxide. Analysis of the surface (skin) of a poly(L-lactide) injection-molded rod following plasma sterilization indicated an increase in molecular weight as related to the interior (core) of the rod. Comparison of Mark-Houwink plots for the surface and interior of poly(L-lactide) injection-molded rods following plasma sterilization indicated an increase in chain branching for the surface relative to the interior of the rod. Generally the highly crystalline poly(L-lactide) was less susceptible to change upon plasma treatment than was the less crystalline poly(L/D-lactide) and poly(L/DL-lactide). The mechanical properties (shear strength, bending strength, and moduli) of the polylactides were not affected by plasma treatment. The overall melting temperature and the heat of melting of polylactides studied were not affected by plasma treatment. The melting temperature of the skin of the samples was about 1 degree C higher than the melting temperature of the core due to the chain orientation upon injection-molding. Plasma treatment of the polylactides reduced the melting temperature of the skin by 3 degrees C to 5 degrees C due to the crosslinking or branching at the surface layer.

Analysis of Variance

Functional evaluation of megaprostheses replacing the proximal femur.

Between 1987 and 1991, 20 large proximal femoral replacements were performed in 19 patients (10 males and 9 females). The median age was 60 years (15 to 89 years). Four patients presented with a primary sarcoma involving the proximal femur; 15 had bone destruction secondary to metastatic disease. Twelve of the 20 had a pathological bone fracture. The average length of the proximal femoral resection was 12 cm (7 to 26 cm). Fourteen patients could be evaluated for pain and function according to the SICOT hip-evaluation score. All patients, except one with rapidly progressing local disease, were able to walk again independently using one or two crutches. Limping and a positive Trendelenburg sign were observed in all cases but two.

Activities of Daily Living