PubMed Health⌕ Search

Biomedical subjects

P Maksud

Publications and source records attributed to P Maksud.

5 recordsLinked to original sources

Absolute activity quantitation in simultaneous 123I/99mTc brain SPECT.

UNLABELLED: Dual-isotope imaging can allow simultaneous assessment of brain perfusion using a 99mTc-labeled tracer and neurotransmission using an 123I-labeled tracer. However, the images are affected by scatter, cross talk, attenuation, distance-dependent collimator response (DCR), and partial-volume effect. We determined the accuracy and precision of activity quantitation in simulated normal and pathologic studies of simultaneous 123I/99mTc brain SPECT when compensating for all degrading phenomena. METHODS: Monte Carlo simulations were performed using the Zubal brain phantom. Contamination caused by high-energy 123I decay photons was incorporated. Twenty-four 99mTc and 123I activity distributions were simulated on the basis of normal and pathologic patient activity distributions. Cross talk and scatter were corrected using a new method based on a multilayer perceptron artificial neural network (ANN), as well as by the asymmetric window (AW) approach; for comparison, unscattered (U) photons of 99mTc and 123I were recorded. Nonuniform attenuation and DCR were modeled in an iterative ordered-subset expectation maximization (OSEM) algorithm. Mean percentage biases and SDs over the 12 normal and 12 pathologic simulated studies were computed for each structure with respect to the known activity distributions. RESULTS: For 123I, AW + OSEM yielded a bias of 7% in the cerebellum, 21% in the frontal cortex, and 36% in the corpus callosum in the simulated normal population. The bias was increased significantly in the striata of simulated pathologic studies (P < 0.05). The bias associated with ANN was significantly lower (<9% in these brain structures, P < 0.05). For 99mTc with AW + OSEM, the bias was 60% in the corpus callosum, 36% in the striata, and 18%-22% in the cortical lobes in the simulated normal population. This bias was <11% in all brain structures with ANN. In the simulated pathologic population, the bias associated with AW increased significantly in the cortical lobes to 55% (P < 0.05), although it did not change significantly with ANN. CONCLUSION: The accuracy and variability over simulated normal and pathologic studies of both 99mTc and 123I activity estimates were very close with ANN to those obtained with U + OSEM. ANN + OSEM is a promising approach for absolute activity quantitation in simultaneous 99mTc/123I SPECT.

Alzheimer Disease↗

Artificial neural network as a tool to compensate for scatter and attenuation in radionuclide imaging.

UNLABELLED: This study investigates the ability of artificial neural networks (ANN) to simultaneously correct for attenuation and Compton scattering in scintigraphic imaging. METHODS: Three sets of experiments are conducted using images of radioactive sources with various shapes and distributions in a homogeneous medium. Numerical Monte Carlo simulations and physical phantom acquisitions of radioactive geometric sources provide the basic material for correction. Our method is based on the following assumptions: information needed to correct for scattering can be extracted from the energy spectrum at each pixel without any assumption concerning the source distribution, and two diametrically opposed energy spectrum acquisitions yield enough information on the source location in the diffusing medium for simultaneous correction for attenuation and scattering. RESULTS: Qualitative and quantitative evaluations of scatter correction by ANN demonstrate its ability to perform scatter correction from the energy spectra observed in each pixel. By using the energy spectra of incident photons detected in two diametrically opposed images, multilayer neural networks are able to perform a proper restitution of projection images without any assumption on geometry or position of radioactive sources in simple geometric cases. ANN corrections compare favorably to those provided by five of the most popular methods. A satisfying correction of both scatter and attenuation is observed for a human pelvis scan obtained during routine clinical practice. CONCLUSION: An ANN is an efficient tool for attenuation and Compton scattering in simple model cases. The results obtained for routine scintigrams in a much more complex situation are strong incentives for performing further studies.

Bone and Bones↗

[Parathyroid adenoma encapsulated in a thyroid adenoma: an anatomical curiosity].

We describe a primitive hyperparathyroid in a old woman due to a parathyroid adenoma localized by Technetium 99m, Thallium 201 scintigraphy within the thyroid gland. During surgery, this adenoma was found inside a thyroid adenoma. It is the second case reported on the literature in a such localization. We underline the interest of the scintigraphy Technetium 99m, Thallium 201, for the detection of ectopic parathyroid adenoma.

Adenoma↗

Chronic cisplatin nephropathy in rats.

The long-term renal effects of cisplatin have been very poorly studied. Therefore we investigated the chronic renal effects of various doses of cisplatin in three groups of male Sprague-Dawley rats. Group I received two injections of 5 mg/kg body weight (bw) at 4-week intervals, group II four injections of 2.5 mg/kg bw at 4-weeks intervals, and group III one injection of 5 mg/kg bw and four injections of 2.5 mg/kg bw at 4-weeks intervals. Controls received an equivalent amount of isotonic saline. Each group was evaluated 1, 3, or 6 months after the last injection of cisplatin. One, 3 and 6 months after the last injection, cisplatin induced a marked decrease in glomerular filtration rate (GFR) evaluated as clearance of [99mTc]DTPA and creatinine clearance in all treated rats. Urinary NAG excretion remained unaltered. At 3 months post-cisplatin treatment GFR was significantly less (P < 0.05) in group III (0.18 +/- 0.02 ml/min/100 g bw) when compared with group I (0.23 +/- 0.02 ml/min/100 g bw) or II (0.23 +/- 0.04 ml/min/100 g bw). In group I GFR was similar 1 month (0.24 +/- 0.02), 3 months (0.23 +/- 0.02) and 6 months (0.23 +/- 0.03 ml/min/100 g bw) after cisplatin treatment. Cisplatin induced atrophy and dilatation of tubules with mononuclear cell infiltration associated with cyst formation. The glomerular and tubulointerstitial lesions were significantly enhanced in group III when compared with groups I and II. This study indicates that repeated administration of cisplatin may induce a chronic tubulointerstitial nephropathy associated with a marked decrease in GFR, which is stable over time. The incidence and severity of chronic cisplatin toxicity is dose-related and is not modified by dividing the dose.

Animals↗

Renal function and blood pressure in patients receiving long-term, low-dose cyclosporine therapy for idiopathic autoimmune uveitis.

OBJECTIVE: To determine the renal side effects of long-term, low-dose cyclosporine therapy (initial dose, 5 mg/kg body weight per day) in patients with autoimmune idiopathic uvetis. DESIGN: Cohort study with at least 2 years of follow-up. SETTING: A teaching hospital in Paris, France (Hôpital Pitié-Salpétrière). PATIENTS: Sixteen patients with idiopathic autoimmune uveitis who were normotensive and had normal renal function before treatment. Cyclosporine was administered orally for at least 2 years at an initial dosage of 5 mg/kg body weight per day. RESULTS: After 2 years of treatment, the serum creatinine level increased by 35 +/- 5 mumol/L (0.40 +/- 0.06 mg/dL) (95% CI, 25 to 46 mumol/L, [73 +/- 4 to 108 +/- 4 mumol/L]). Creatinine clearance decreased significantly from 120 +/- 5 mL/min to 75 +/- 4 mL/min. Glomerular filtration rate decreased from 116 +/- 8 mL/min to 75 +/- 3 mL/min, and effective renal plasma flow decreased from 455 +/- 24 mL/min to 338 +/- 30 mL/min (P less than 0.05). Cyclosporine induced a significant increase in serum uric acid, total cholesterol, and serum potassium levels. Blood pressure was normal in all patients before treatment; 81% (95% CI, 64% to 98%) of these patients developed hypertension after 24 months of treatment. Blood pressure was controlled with a single drug in all but two patients. CONCLUSIONS: In patients with healthy native kidneys, long-term cyclosporine therapy, even at a low dose (5 mg/kg per day), is nephrotoxic and is associated with a high incidence of hypertension.

Adult↗