Effects of N-acetylcysteine on tissue oxygenation in patients with multiple organ failure and evidence of tissue hypoxia.

Covert tissue hypoxia, particularly of the splanchnic region, appears important in the pathogenesis of multiple organ failure (MOF). This investigation evaluates the effects of N-acetylcysteine (NAC) upon several measures of tissue oxygenation in 10 patients with severe MOF and evidence of splanchnic hypoxia (as suggested by a pathologically low value (< 7.32) of the pH of the gastric mucosa (pHi)). Patients were studied following a prospective, randomized, placebo-controlled, cross-over design. Measurements included pulmonary and systemic haemodynamics, cardiac output by thermodilution, arterial and mixed venous blood gas values, blood lactate concentration, whole-body oxygen uptake by analysis of the expired gases, and pHi by tonometry. A complete set of measurements was obtained before and 45 min after the infusion of NAC (150 mg.kg-1 in 250 mL of saline) and, also, before and 45 min after the infusion of an equivalent volume of saline. NAC increased the cardiac index and vasodilated the systemic circulation (p < 0.01). However, O2 delivery to the tissues did not increase because the arterial oxygen content fell after NAC (p < 0.01). Mean O2 extraction or lactate concentration did not change after NAC, and pHi fell slightly (from 7.11 +/- 0.21 to 7.07 +/- 0.21; p < 0.05). The infusion of saline did not modify any variable significantly. The O2 extraction fraction increased exponentially in those patients with reduced O2 transport to the tissues. These results argue against a beneficial effect of N-acetylcysteine upon tissue oxygenation in patients with severe multiple organ failure and evidence of splanchnic hypoxia. Furthermore, they suggest that the mechanisms controlling the extraction of oxygen by the peripheral tissues in these patients were not impaired.

Acetylcysteine↗

Validation of a new closed circuit indirect calorimetry method compared with the open Douglas bag method.

New equipment designed for the routine measurement of oxygen uptake (VO2) using a closed circuit method has been validated by comparing it with a standard Douglas bag method. The equipment (The Caloric Measurement Unit, CMU) has been tested in 10 critically ill patients during mechanical ventilation (MV) and in 10 spontaneously breathing healthy subjects. Determinations of VO2 and of the resting energy expenditure (REE) were measured in duplicate with the standard method and once with the CMU. Six additional patients receiving MV were studied with the CMU to evaluate the reproducibility and the effect of FIO2 = 1 vs FIO2 = 0.43 on VO2 measurements. Considering the whole group of 10 patients and 10 subjects, the mean difference of VO2 between both methods was -2 +/- 21 ml/min (95% confidence interval, -11.8 to 7.8 ml/min, p = 0.6) standard deviation. Both methods had a similar reproducibility and the mean difference of VO2 measured at the two different FIO2 with the CMU was -3.2 +/- 11 ml/min (95% confidence interval, -14.7 to 8.4 ml/min, p = 0.5). No statistically significant difference was found between derived REE values obtained from either method. These data show a good correlation between the two methods suggesting that CMU may be used in place of the standard method with the same accuracy in measurement of VO2 even at FIO2 = 1.

Adult↗

Wedge pulmonary angiography to determine the accuracy of pulmonary wedge pressure.

Wedge pulmonary angiography was done in 11 patients with acute respiratory failure, to assess the accuracy of pulmonary arterial wedge pressure (WP) as an estimation of left ventricular end-diastolic pressure (LVEDP). The pulmonary artery (PA) catheter tip was placed into a dependent position in the lungs. Although the pulmonary vein was not visualized in 7 of 11 patients, in no case was there a significant difference between WP and LVEDP. When WP is no greater than 15 mm Hg, wedge pulmonary angiography does not reflect the accuracy of WP; however, left ventricular filling pressure can be accurately estimated by WP in most of these patients.

Acute Disease↗

Gastroesophageal reflux in intubated patients receiving enteral nutrition: effect of supine and semirecumbent positions.

The incidence of gastroesophageal reflux (GER) in critically ill patients as well as the effect of a nasogastric tube (NGT) and body position as risk factors for GER were determined. Seventy patients with orotracheal intubation receiving enteral nutrition through a NGT for more than 48 hours were prospectively studied with two randomly assigned body positions: supine or semirecumbent. Detection of GER was achieved by scintigraphy after labeling gastric contents with 500 microCi of technetium-99m sulfur colloid administered through the NGT. In 50 patients scintigraphy was performed after subjects had remained in the randomized position for 2 hours with the NGT pinched. Twenty additional patients were studied after the NGT had been removed. In 50 patients with NGT, GER was present in 74% (37 of 50) and was higher in the supine position (81%, 21 of 26) than in the semirecumbent position (67%, 16 of 24), but this difference was not statistically significant (p = .26). In 20 patients without NGT, the incidence of GER was 35% (7 of 20) and it was also higher in the supine (50%, 6 of 12) than in the semirecumbent position (12%, 1 of 8, p = .16). There was a statistically significant difference between GER in patients with and without NGT (74% vs 35%, p = .0002). These data show that there is a high incidence of GER in patients with orotracheal intubation and NGT. The presence of a NGT is a risk factor for GER. Semirecumbency does not prevent GER, but there is less incidence than in the supine position.