PubMed HealthSearch

Biomedical subjects

P Matos

Publications and source records attributed to P Matos.

6 recordsLinked to original sources

[Civil aviation and cardiology. Admission rules and follow-up of the technical flying personnel of TAP-Air Portugal].

The authors, based in European and American rules, consensus positions of Clinical Aerospace Congresses and their own experience, marked admission and follow-up rules of conduct for TAP Air Portugal aircrew. They stressed the importance of modern technology in arterial pressure ambulatory diagnosis and pointed the necessity of arterial pressure treatment in the other cardiovascular risk factors context. They relief ischemic myocardial disease because it is incompatible with flying safety, even in those submitted to coronary angioplasty or bypass graft surgery. For those with arrhythmias, valvular heart disease, myocarditis, cardiomyopathy and adult life congenital heart disease, we emphasize admission and follow-up rules.

Aerospace Medicine

[Mitral prostheses with and without dysfunction: evaluation using 2-D Doppler echocardiography].

STUDY OBJECTIVE: To evaluate the flow characteristics of normal and abnormal functioning mechanical and bioprosthetic (B) mitral valves. DESIGN: Prospective study in patients submitted to mitral valve replacement. SETTING: Laboratory of Echocardiography at Santa Marta Hospital. PATIENTS: 61 consecutive and asymptomatic patients with normally functioning mitral prosthesis (prt)--37 Bjork-Shiley (B-S), 11 Carpentier-Edwards (C-E), 5 Hancok (HAN), 7 Ionescu-Shiley (I-S) and 1 Wessex--and 15 pts with abnormal prosthetic function (6 B-S, 5 Hall-Kaster, 2 C-E, 1 I-S and 1 HAN). INTERVENTION: Prosthetic mitral flow record, using 2D-Doppler echocardiography, to analyse: peak velocity (PV), peak gradient (PG), mean gradient (MG), pressure half time (PHT), area (A) and presence of regurgitation (R). RESULTS: Normally functioning prosthetic valves--PV ranged from 88 to 186 cm/s (134.6 +/- 24.3) in B-S prt and 133 to 198 cm/s (157.4 +/- 18.8) in B, p less than 0.0001. The prt B-S showed a greater PG (10.3 +/- 2.5 vs 7.6 +/- 2.6 mmHg), MG (3.1 +/- 1.1 vs 2.6 +/- 1 mmHg) and smaller area (2.3 +/- 0.4 vs 2.5 +/- 0.4 cm2) then Bioprosthetic ones, p less than 0.0001, p = 0.003, p = 0.003 respectively. There was a significant correlation between PG and MG: r = 0.84, r = 0.87, r = 0.84 respectively in B-S prt, Bioprosthesis and both, p less than 0.001. Mild regurgitation was present in 8 pts with prt B-S and 4 with B. Malfunctioning prosthetic valves--The mean of PV was 238.5 +/- 29.2 cm/s in prt B-S compared to 265.48.2 +/- 48.2 cm/s in B. Significant regurgitation, was detected by Doppler technic in 100% of B and 72% of mechanical prt. PV greater than 2 m/s has a 100% sensitivity and specificity to separate normal from abnormal prosthesis function. CONCLUSIONS: These data may be useful as reference values to the follow-up of pts with these types of prt. The prt B-S seems to have more optimal hemodynamics profile than B ones. Protodiastolic transprosthetic PV greater than 2 m/s suggest abnormal functioning valve. PG is a significant determinant of MG.

Adult

[Flow patterns of a normally functioning monocuspid aortic prosthesis evaluated using Doppler echocardiography].

STUDY OBJECTIVE: Flow analysis in normally functioning eccentric monocuspid aortic prosthetic valves, to obtain a reference data list. DESIGN: To analyse, using 2D-Doppler Echocardiography, aortic flow velocity and systolic time intervals in clinically normal patients (pts), by physical examination. SETTING: Referred pts to the Echocardiographic Laboratory at Santa Marta Hospital--HCL. PATIENTS: Sequential sample of 61 pts with aortic prosthesis (41 Bjork-Shiley and 20 Hall-Kaster) without clinical evidence of either cardiac failure or significant aortic regurgitation. Patients with bad quality record were also excluded. INTERVENTIONS: Doppler Echocardiography was used to record transaortic flow, and the following indexes were analysed: instantaneous peak velocity (pv) and gradient (pg), presence of regurgitation, systolic time intervals and both preejection period/ejection time (PEP/ET) and acceleration time/ejection time (AT/ET). RESULTS: Pv ranged from 1.1 to 4 m/sec (mean 2.4 +/- 0.2. The prosthesis size 19 and 21 showed a greater pg compared to the larger ones: 46.3 +/- 14.4 mmHg against 12.6 +/- 6.4 mmHg (p less than 0.001). Occasionally a pg over 50 mmHg was found in the prosthesis size 19 and 21. The correlation between prosthesis size and pg was also significant (r = -0.62; p less than 0.001). PEP interval was 60 +/- 10 milisec in prosthesis no. 19 and 90 +/- 13 milisec in no. 27 (p less than 0.01). AT ranged from 77 +/- 14 to 88 +/- 14 milisec (mean 82 +/- 13). ET was 294 +/- 5.4 milisec in valves size 19 and 257 +/- 34 millisec in no. 25 (p less than 0.05); there was also a significant difference between prosthesis size 19 and 27 (p less than 0.05). Mild regurgitation was detected in 32.7% of cases. CONCLUSIONS: These data may be particularly useful as reference values to the follow-up of pts these types of prosthesis. Significant differences were found in pg between different valve sizes and this should be remembered when proceeding to standard evaluation by 2D-Doppler Echocardiography. Regurgitation is frequently detected in normally functioning prosthesis, not deeper than 2 cm in the left ventricle.

Adult

Sex preselection in New York City: who chooses which sex and why.

With its increasing success, sex preselection has become a matter of general concern, and interest in it is growing. Three aspects of sex preselection in New York City were considered. Who is choosing the sex? Which sex is being chosen? Why have the choices been made? In this investigation, 178 couples were studied and all 57 non-American couples chose boys; however, 120 American couples chose boys and girls with equal frequency depending upon the gender of the children at home. Non-American couples chose boys for economic and business reasons (40%), cultural reasons (30%), and personal reasons (30%). Sex preselection is valuable in preventing sex-linked genetic disorders. Many are fearful of a sudden change in sex ratios should sex preselection be successfully and inexpensively carried out.

Cultural Diversity