Real in vivo kinematic differences between mobile-bearing and fixed-bearing total knee arthroplasties.

We did an in vivo fluoroscopic study comparing the sagittal plane kinematics of mobile-bearing and fixed-bearing total knee arthroplasties in a unique group of patients. These patients were part of a larger bilateral randomized controlled outcome trial with each patient having received both types of total knee arthroplasties. Invited patients did three exercises with each of their different knee replacements; extension against gravity, flexion against gravity, and a step-up. These exercises were recorded using video fluoroscopy, and a series of still digital images over the flexion range were retrieved. The relationship of patella tendon angle to knee flexion angle for each patient was derived. The patella tendon angle to knee flexion angle of the mobile-bearing knee behaved in a linear manner more closely replicating the normal knee, whereas the fixed-bearing knee behaved in a nonlinear, more variable manner. This pattern of results was similar for all three exercises with each patient having one knee replacement that behaved differently in the sagittal plane when compared with their other knee replacement. These kinematic differences may explain the clinical differences observed in the randomized controlled trials that compared these two total knee arthroplasties.

Adult↗

The effect of hip resurfacing on oxygen concentration in the femoral head.

We inserted an electrode up the femoral neck into the femoral head of ten patients undergoing a metal-on-metal hip resurfacing arthroplasty through a posterior surgical approach and measured the oxygen concentration during the operation. In every patient the blood flow was compromised during surgery, but the extent varied. In three patients, the oxygen concentration was zero at the end of the procedure. The surgical approach caused a mean 60% drop (p < 0.005) in oxygen concentration while component insertion led to a further 20% drop (p < 0.04). The oxygen concentration did not improve significantly on wound closure. This study demonstrates that during hip resurfacing arthroplasty, patients experience some compromise to their femoral head blood supply and some have complete disruption.

Adult↗

Osteonecrosis in retrieved femoral heads after failed resurfacing arthroplasty of the hip.

We present the histological findings of bone retrieved from beneath the femoral components of failed metal-on-metal hip resurfacing arthroplasties. Of a total of 377 patients who underwent resurfacing arthroplasty, 13 required revision; for fracture of the femoral neck in eight, loosening of a component in three and for other reasons in two. None of these cases had shown histological evidence of osteonecrosis in the femoral bone at the time of the initial implantation. Bone from the remnant of the femoral head showed changes of osteonecrosis in all but one case at revision. In two cases of fracture which occurred within a week of implantation, the changes were compatible with early necrosis of the edge of the fracture. In the remaining six fractures, there were changes of established osteonecrosis. In all but one of the non-fracture cases, patchy osteonecrosis was seen. We conclude that histological evidence of osteonecrosis is a common finding in failed resurfaced hips. Given that osteonecrosis is extensive in resurfaced femoral heads which fail by fracture, it is likely to play a role in the causation of these fractures.

Arthroplasty, Replacement, Hip↗

Influence of stem geometry on the stability of polished tapered cemented femoral stems.

Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year migration of the Exeter stem with a more recent design, the CPS-Plus, which has a wider shoulder and a more rectangular cross-section. The hypothesis was that these design features would increase rotational stability. Both stems subsided approximately 1 mm relative to the femur during the first two years after implantation. The Exeter stem was found to rotate into valgus (mean 0.2 degrees , sd 0.42 degrees ) and internally rotate (mean 1.28 degrees , sd 0.99 degrees ). The CPS-Plus showed no significant valgus rotation (mean 0.07 [correction] degrees, sd 0.29 [correction] degrees ) or internal rotation (mean -0.03 degrees , sd 0.75 degrees ). A wider, more rectangular cross-section improves rotational stability and may have a better long-term outcome.

Aged↗

Is there a place for shelf acetabuloplasty in the management of adult acetabular dysplasia? A survivorship study.

We followed up 76 consecutive hips with symptomatic acetabular dysplasia treated by acetabular shelf augmentation for a mean period of 11 years. Survival analysis using conversion to hip replacement as an end-point was 86% at five years and 46% at ten years. Forty-four hips with slight or no narrowing of the joint space pre-operatively had a survival of 97% at five and 75% at ten years. This was significantly higher (p = 0.0007) than that of the 32 hips with moderate or severe narrowing of the joint-space, which was 76% at five and 22% at ten years. There was no significant relationship between survival and age (p = 0.37) or the pre- and post-operative centre-edge (p = 0.39) and acetabular angles (p = 0.85). Shelf acetabuloplasty is a reliable, safe procedure offering medium-term symptomatic relief for adults with acetabular dysplasia. The best results were achieved in patients with mild and moderate dysplasia of the hip with little arthritis.

Acetabulum↗

Roentgen stereophotogrammetric analysis of the Birmingham hip resurfacing arthroplasty. A two-year study.

The Birmingham hip resurfacing (BHR) arthroplasty is a metal-on-metal prosthesis for which no medium- or long-term results have been published. Despite this, it is increasing in popularity as an alternative to stemmed prostheses for younger patients. Since the fixation of the socket is conventional, the major concern is long-term failure of the femoral component. This can be predicted by the use of roentgen stereophotogrammetric analysis (RSA). We have therefore undertaken such a study of the BHR femoral component over a period of two years. Twenty patients (22 hips) underwent a standard BHR procedure. Migration of the femoral component was measured by RSA at intervals of three, six, 12 and 24 months. At 24 months the total three-dimensional migration of the head was 0.2 mm. This was not statistically significant. Previous studies have shown that implants which loosen quickly have rapid early migration. Our results therefore suggest that the BHR femoral component is an inherently stable device which is likely to perform well in the long term.

Adult↗

The influence of cement viscosity on the early migration of a tapered polished femoral stem.

It is unclear whether it is best to use high-viscosity or low-viscosity cement for fixation of total hip replacement (THR) femoral components. This study examines the influence of cement viscosity on the migration of the Exeter femoral component using roentgen stereophotogrammetric analysis (RSA). Simplex, CMW1 and CMW3 G cements were examined in a total of 46 patients over a 12-month period. The overall pattern of migration for all cohorts was one of subsidence and rotation into valgus. There was no significant difference in any aspect of migration between the groups. In vitro studies demonstrate that low-viscosity cement forms a more stable bone-cement interface. Several groups have examined the in vivo effect of cement viscosity on stem longevity with conflicting results. For a polished, tapered implant that is designed to subside, cement viscosity does not influence the 1-year migration, and it is therefore unlikely to affect long-term outcome.

Aged↗

A correlative study of clinical and histological findings of revision hip arthroplasty for rheumatoid arthritis and inflammatory joint disease.

OBJECTIVE: Primary hip arthroplasty in rheumatoid arthritis (RA) and other forms of inflammatory joint disease (IJD) is generally thought to be associated with a less favourable outcome in terms of implant survival and other complications. Whether the duration of implant survival correlates with the degree of rheumatoid-like inflammatory changes in periprosthetic tissues is uncertain. METHODS: Histopathological changes in periprosthetic tissues obtained following revision surgery of 34 total hip replacements on 27 patients with IJD (RA 18 cases: ankylosing spondylitis three cases; juvenile chronic arthritis six cases) were examined. RESULTS: A heavy diffuse lymphocyte and plasma cell infiltrate +/- lymphoid aggregates was noted in 29% of cases in whom the mean implant survival was 5.6 years (range: 2-8 years). Where little or no lymphocytic infiltrate was noted in periprosthetic tissues, the mean implant survival was 8.6 years (range: 1-17 years). Revision arthroplasty was not undertaken for early or late infection of a primary hip replacement. CONCLUSIONS: Our findings indicate that implant survival is less in those cases where there is a heavy lymphocyte and plasma-cell infiltrate in periprosthetic tissues. These findings suggest that the presence of a heavy chronic inflammatory-cell infiltrate in periprosthetic tissues is likely to be a contributory factor in causing early implant failure in RA.

Adolescent↗

A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial.

Before proceeding to longer-term studies, we have studied the early clinical results of a new mobile-bearing total knee prosthesis in comparison with an established fixed-bearing device. Patients requiring bilateral knee replacement consented to have their operations under one anaesthetic using one of each prosthesis. They also agreed to accept the random choice of knee (right or left) and to remain ignorant as to which side had which implant. Outcomes were measured using the American Knee Society Score (AKSS), the Oxford Knee Score (OKS), and determination of the range of movement and pain scores before and at one year after operation. Preoperatively, there was no systematic difference between the right and left knees. One patient died in the perioperative period and one mobile-bearing prosthesis required early revision for dislocation of the meniscal component. At one year the mean AKSS, OKS and pain scores for the new device were slightly better (p < 0.025) than those for the fixed-bearing device. There was no difference in the range of movement. We believe that this is the first controlled, blinded trial to compare early function of a new knee prosthesis with that of a standard implant. It demonstrates a small but significant clinical advantage for the mobile-bearing design.

Aged↗

The effect of anteversion on femoral component stability assessed by radiostereometric analysis.

Internal rotation of a femoral stem within the femur, with posterior migration of the femoral head (PHM) relative to the femur, is an important mode of failure. The relationship between anteversion and rotational stability for the Exeter (Howmedica International Ltd, London, UK) and Charnley Elite (DePuy International Ltd, Leeds, UK) stems was investigated using radiostereometric analysis (RSA). For the Elite, there was a significant (P=.01) correlation between anteversion and PHM, whereas for the Exeter, there was no significant correlation (P=.6). Increasing anteversion of the Elite was associated with decreasing PHM and increased stability. Of stems, 20% of the Elite and none of the Exeter were classified as having reduced rotational stability because their PHM was >2 SDs from the mean. All reduced rotational stability implants had anteversion substantially <20 degrees. Polished collarless tapered stems such as the Exeter seem to have enhanced rotational stability. For conventional stems, increasing anteversion increases stability. It is recommended that these stems are anteverted 20 degrees.

Hip Prosthesis↗

Serum levels of cobalt and chromium in a complex modular total hip arthroplasty system.

There is concern that modularity in a total hip arthroplasty system increases serum cobalt and chromium ion levels. This study measures the serum cobalt and chromium levels in patients with an Oxford Universal Hip (Corin, Cirencester, United Kingdom), which has a modular sliding mechanism; patients with a similarly manufactured hip with no sliding mechanism; and a control group. Loosening was excluded clinically and radiologically. Arthroplasty patients had statistically higher levels of serum cobalt and chromium than controls, but there was no significant difference in levels between the implanted groups.

Arthroplasty, Replacement, Hip↗

Evidence for the validity of a patient-based instrument for assessment of outcome after revision hip replacement.

The Oxford hip score (OHS) is a patient-based instrument for assessment of outcome which is often used after total hip replacement, and the EuroQol 5D (EQ5D) is a patient-based generic questionnaire for health assessment. In an analysis of the outcome at one year of 609 revision hip replacements (RHRs), we compared the OHS and EQ5D scores, postoperative patient satisfaction and change in pain. About 25% of the operations were repeat RHRs. At one year, 57% of patients were very pleased with their operation. The correlation between preoperative and postoperative scores and change scores for the OHS and EQ5D was high. For both instruments the effect sizes were large, but the greater effect size of the OHS suggests that it is particularly sensitive to improvements after RHR. The effect scores of the OHS declined with the number of previous RHRs, while those for the EQ5D seemed less sensitive. Our results confirm the value of the OHS in assessing outcome after RHR.

Arthroplasty, Replacement, Hip↗

Prosthetic Joint Infection.

Total joint replacement has been one of the most remarkable successes of modern medical technology. Once John Charnley had solved the problems of implant design, choice of materials, implant fixation, and infection (initial rates of infection were approximately 10%), the way was clear for the widespread use of this valuable treatment, which is highly effective at removing pain and restoring function. Unfortunately, infection still remains an important, though less common, problem. It is associated with serious morbidity (pain, loss of function, wound breakdown, wound discharge, implant failure) and sometimes mortality. It may be impossible to eradicate or suppress infection in the long term without removal of the prosthesis, and most clinicians would consider it unwise to re-implant a new prosthesis in the presence of infection. Hence, patients with infected prosthetic joints generally require multiple additional operations and prolonged periods of antibiotic therapy. Even radical attempts at cure may fail (in 10% to 15% of cases in most series), requiring further cycles of treatment with progressively deteriorating function. Thus, the treatment of prosthetic joint infection is arduous for the patient and the health care team, with no guarantee of success.

Journal Article↗

Prospective evaluation of criteria for microbiological diagnosis of prosthetic-joint infection at revision arthroplasty. The OSIRIS Collaborative Study Group.

A prospective study was performed to establish criteria for the microbiological diagnosis of prosthetic joint infection at elective revision arthroplasty. Patients were treated in a multidisciplinary unit dedicated to the management and study of musculoskeletal infection. Standard multiple samples of periprosthetic tissue were obtained at surgery, Gram stained, and cultured by direct and enrichment methods. With reference to histology as the criterion standard, sensitivities, specificities, and likelihood ratios (LRs) were calculated by using different cutoffs for the diagnosis of infection. We performed revisions on 334 patients over a 17-month period, of whom 297 were evaluable. The remaining 37 were excluded because histology results were unavailable or could not be interpreted due to underlying inflammatory joint disease. There were 41 infections, with only 65% of all samples sent from infected patients being culture positive, suggesting low numbers of bacteria in the samples taken. The isolation of an indistinguishable microorganism from three or more independent specimens was highly predictive of infection (sensitivity, 65%; specificity, 99.6%; LR, 168.6), while Gram staining was less useful (sensitivity, 12%; specificity, 98%; LR, 10). A simple mathematical model was developed to predict the performance of the diagnostic test. We recommend that five or six specimens be sent, that the cutoff for a definite diagnosis of infection be three or more operative specimens that yield an indistinguishable organism, and that because of its low level of sensitivity, Gram staining should be abandoned as a diagnostic tool at elective revision arthroplasty.

Arthroplasty, Replacement, Hip↗

Ultrasonically driven tools.

Ultrasonically driven tools have been employed extensively in revision hip surgery during the last 2 years at the Nuffield Orthopaedic Centre. In combination with hand revision instruments, the removal of cement, in particular the removal of the distal cement plug, has been made safer. One significant complication that has occurred with this device is reported and advice on its prevention offered.

Adult↗

Revision of cemented fixation and cement-bone interface strength.

Interfacial shear strength between poly(methyl methacrylate) (PMMA) bone cement and cancellous bone was measured in bone samples from human proximal femora. Samples were prepared with fresh cement-bone, fresh cement inside a mantle of existing cement and with fresh cement-revised bone surfaces. Push-out tests to measure shear strength caused failure only at bone-cement interfaces; revised bone interfaces were 30 per cent weaker (P < 0.02) than primary interfaces. The clinical relevance is that revision of cemented joint arthroplasties may necessitate removal of components with sound cement-bone fixation. The practice of removing all traces of PMMA cement may not yield the optimal fixation; adhesion of fresh cement to freshly prepared surfaces of the existing cement might also be considered where circumstances are favourable.

Bone Cements↗

The frozen hip.

Explore the source record for details and available documents.

Diagnosis, Differential↗

Ischaemic contracture of the intrinsic muscles of the hands. A hazard of physical restraint.

A case is described of bilateral ischaemic contracture of the intrinsic muscles of the hands, presenting in a mentally-disturbed patient one year after a reported period of immobilisation in a physical restraint device. Involvement of the deep thenar muscles and the interossei on the radial side of the hand can be explained by consideration of the anatomy of the deep palmar arch. Division of the tendons of the contracted interosseous muscles proximal to the metacarpophalangeal joints and release of the left first web improved hand function. Those who supervise the use of physical restraint devices should be aware of the risk of intrinsic muscle ischaemia and of the need for prompt diagnosis and treatment.

Adult↗