Homocysteine and methylmalonic acid concentrations in cerebrospinal fluid: relation with age and Alzheimer's disease.

BACKGROUND: Homocysteine may be involved in the pathogenesis of late onset Alzheimer's disease. It is implicated in the metabolism of several important pathways in the brain. Methylmalonic acid (MMA) is related to the metabolism of branched chained amino acids and fatty acids. OBJECTIVES: To compare cerebrospinal fluid (CSF) total homocysteine and MMA in elderly subjects, patients with Alzheimer's disease, and younger healthy controls. SUBJECTS: CSF samples were obtained from 33 patients under 20 years of age; 28 patients aged 21 to 60 years; 22 normal elderly subjects aged over 60; and 38 Alzheimer patients aged over 60. RESULTS: CSF total homocysteine increased with age (mean (SD): 57 (35) nmol/l in the youngest group v 123 (89) nmol/l in the elderly group (p<0.001)). There was no difference between the elderly group and Alzheimer patients (115 (62) nmol/l). CSF MMA did not differ in the elderly group and the Alzheimer group (38 (13) v 35 (14) ng/ml). In the youngest group, it was significantly higher (60 (15) ng/ml). CONCLUSIONS: CSF total homocysteine is not increased in Alzheimer's disease compared with age matched controls. CSF total homocysteine was correlated with age. The decrease in CSF MMA levels with age eliminates a lack of vitamin B-12 at neuronal level.

Adult↗

Increases of IgA milk concentrations correlate with IgA2 increment.

IgA, IgA1, and IgA2 concentrations were determined in 81 defatted human milk samples: colostrum (days 1-5, n = 42), transitional milk (days 6-14, n = 18) and mature milk (days 15-75, n = 21) by immunonephelometry. Correlations were found between total IgA levels and the concentrations of both IgA subclasses (P < 0.0001). The levels of the three molecules decreased over lactation with significant differences (P < 0.05) between colostrum and transitional milk levels and between colostrum and mature milk. Colostral IgA1 and IgA2 mean concentrations dropped respectively from 10.89 +/- 2.12 g/L, and 15.41 +/- 2.10 g/L to 1.83 +/- 0.73 g/L and 3.40 +/- 1.25 g/L in transitional milk reaching finally to 0.36 +/- 0.07 g/L and 0.27 +/- 0.06 g/L in mature milk. IgA2 concentrations were higher than those of IgA1 when the total IgA level was high. The IgA2 levels in colostrum could be an adaptation resistance of IgA to potentially harmful pathogens able to secrete IgA proteases and also a way to regulate colonization of the microflora in the newborn.

Female↗

Changes in lactoferrin and lysozyme levels in human milk during the first twelve weeks of lactation.

Changes in the lactoferrin and lysozyme concentration of human milk during lactation were determined by microparticle-enhanced nephelometric immunoassays of 360 milk samples collected from 64 lactating volunteers. These 360 samples were colostrum from days 1 to 5 postpartum (142 samples), transitional milk from days 6 to 14 (106 samples), and 112 mature milk samples obtained from days 15 to 28 (34 samples), from days 29 to 56 (50 samples) and from days 57 to 84 postpartum (28 samples). The concentration and percentage of lactoferrin vs. total protein were found to be significantly higher in colostrum (5.8 g/L, 27%) than in transitional milk (3.1 g/L, 22%) or day 15 to 28 mature milk (2.0 g/L, 19%), then increased in day 29 to 56 mature milk (2.2 g/L, 22%) and day 57 to 84 mature milk (3.3 g/L, 30%). The concentration of lysozyme decreased from colostrum (0.37 g/L) to transitional milk (0.27g/L) and day 15 to 28 mature milk (0.24 g/L), then increased in day 29 to 56 mature milk (0.33 g/L) and was highest in day 57 to 84 mature milk (0.89 g/L). The percentage of lysozyme vs. total protein was found to be always rising during lactation: colostrum, 2%; transitional milk, 2%; days 15 to 28, 2%; days 29 to 56, 3%; and days 57 to 84 mature milk, 8%.

Colostrum↗

Sequential C3 and C4 levels in human milk in relation to prematurity and parity.

Similarly to many immune molecules of human milk, C3 and C4 levels decrease during lactation. We investigated the influence, over the first three weeks of lactation, of both prematurity and parity on the sequential evolution of these levels. Milk C3 and C4 concentrations were measured by immunonephelometry in 494 individual samples collected from 76 lactating mothers. C3 and C4 concentrations were higher in milk from preterm or primiparous mothers. The major differences were observed in milk from days 5-8 and 9-20, likely due to pronounced interindividual variations in levels of days 1-4 milk. Milk from mothers of precocious (33 weeks' gestation or less) preterm newborns presented higher concentrations and a slower decrease of C3 and C4 levels than that from mothers of late (33-37 weeks' gestation) preterm newborns, when compared to term mothers. Finally, the inversion of the C3/C4 ratio occurring over time, previously reported, appeared later in milk from mothers of preterm newborns. The influence of prematurity was even greater in primiparous than in multiparous mothers. Both C3 and C4 levels therefore appear to be influenced in human milk by the parity and prematurity of the delivery. Mothers from preterm newborns seem to provide higher levels of C3 for a longer period post delivery.

Complement C3↗

C3/C4 concentration ratio reverses between colostrum and mature milk in human lactation.

The levels of complement fractions C3 and C4 were assayed in human milk in a classic nephelometric assay adapted to this secretion. Concentrations of these molecules were measured in 667 milk samples obtained sequentially from 76 volunteer lactating mothers during the first 12 weeks of lactation. Immunonephelometry was performed using skimmed milk samples diluted 10 times and yielded reproducible (coefficients of variation in within- and between-run precision lower than 9% for C3 and than 14% for C4) and accurate (linear recovery in dilution-overloading assay) data. High concentrations (mean +/- SE) were found for C3 (199.32+/-16.35 mg/L) and C4 (113.42+/-11.16 mg/L) in colostrum samples (n = 159; days 1-5). A significant (P<0.001) and rapid decrease was observed in transitional milk samples (n = 198; days 6-14), containing 57.71+/-5.18 and 72.39+/-4.98 mg/L of C3 and C4, respectively. Stable lower levels were noted in mature milk samples (n = 310; days 15-84) at 30.36+/-1.57 mg/L for C3 (P<0.001) and 53.38+/-3.61 mg/L for C4 (P<0.05). The decrease rate was different for C3 and C4, yielding a reversal of the C3/C4 ratio between colostrum and more mature milk.

Calibration↗

Immunological and nutritional composition of human milk in relation to prematurity and mother's parity during the first 2 weeks of lactation.

BACKGROUND: To investigate the effect of prematurity and parity on the dynamics of the major immunologic and nutritional proteins of human milk over the first 2 weeks of lactation. METHODS: Microparticle-enhanced nephelometric immunoassays were developed for the quantification of alpha-lactalbumin, beta-casein, serum albumin, lactoferrin, and lysozyme in human milk. These components, immunoglobulin A, and total proteins were assayed in 368 individual samples collected from 74 mothers. RESULTS: The dynamics of the major immunologic and nutritional proteins in early lactation presented similar patterns in preterm and term human milks. In comparison with term milk, preterm milk was globally characterized by higher concentrations of immune proteins and lower concentrations of nutritive proteins. These differences were increased by the degree of prematurity, which, however, influenced the absolute and relative protein concentrations differently, depending on the stage of lactation. The protein composition of term milk was similar, whatever the mother's parity. Conversely, the influence of prematurity on the levels of milk proteins during the first days of lactation was even greater in primiparous mothers. CONCLUSIONS: This precise description of the composition of preterm and term milk, regarding the main nutritional and immunologic proteins, confirms the influence of both prematurity and parity on milk components and demonstrates the combined effect of these two conditions.

Female↗

Changes in the kappa-casein and beta-casein concentrations in human milk during lactation.

A microparticle-enhanced nephelometric immunoassay was developed for kappa-casein quantification in human milk. Together with a previously reported beta-casein comparable immunoassay, it was applied to 862 samples milk, collected from 82 mothers, to investigate the changes in casein concentrations in human milk during the first twelve weeks of lactation. kappa-casein immunoassay is sensitive (detection limit in the reaction mixture, 0.02 mg/L) and can be performed in diluted milk, excluding any interference or sample pretreatment. It allowed the quantitation of kappa-casein over a large range of concentrations (0.14-4.56 g/L) with accuracy and precision (coefficients of variation from 3 to 10%). beta- and kappa-casein concentrations and percentages among milk total proteins increase between colostrum (2.6 g/L, 14.3% and 1.2 g/L, 6. 5%, respectively) and transitional milk (4.4 g/L, 33.2% and 1.3 g/L, 9.5%), decrease at different rates from the third to the eighth week, then remain stable at least up to the end of the third month of lactation (2.7 g/L, 25.3% and 0.9 g/L, 8.5%). The beta-casein/kappa-casein ratio is higher in colostrum (0.61) than in transitional and mature milk (0.30) and could be related to a better digestibility of colostrum casein micelles by the neonate during the first days of life.

Antibodies↗

Microparticle-enhanced nephelometric immunoassay of lysozyme in milk and other human body fluids.

Quantitation of lysozyme in human milk was performed by a microparticle-enhanced nephelometric immunoassay based on the measurement of the light scattered during the competitive immunoagglutination of a microparticle-lysozyme conjugate with an anti-lysozyme antiserum. This immunoassay has a detection limit of 8 microg/L of reaction mixture and can be performed using diluted milk (1:6000, in reaction mixture), excluding sample pretreatment. Human milk lysozyme can be quantified over the concentration range 0.09-1.50 g/L, with within- and between-run coefficients of variation <5%. Changes in the lysozyme concentration of human milk during lactation were determined in 636 samples. Lysozyme concentrations (mean +/- SE) decreased from colostrum (0.36 +/- 0.02 g/L) to transitional milk (0.30 +/- 0.01 g/L) and mature milk during days 15-42 (0.30 +/- 0.01 g/L), then increased in the mature milk during days 43-56 (0.35 +/- 0.01 g/L) and especially during days 57-84 (0.83 +/- 0.05 g/L). The proportion of lysozyme contributing to total protein was found to rise during lactation and was as follows: colostrum (1.7%), transitional milk (2.3%), and mature milk from days 15-28 (2.7%), days 29-42 (3.1%), days 43-56 (3.8%), and days 57-84 (7.3%). The assay developed for milk was also suitable for the determination of lysozyme in other human body fluids.

Adolescent↗

Microparticle-enhanced nephelometric immunoassay of alpha-lactalbumin in human milk.

A microparticle-enhanced nephelometric immunoassay was developed for alpha-lactalbumin quantitation in human milk. It is based on the nephelometric measurement of the light scattered during the competitive immunoagglutination of a microparticle-alpha-lactalbumin conjugate with an anti-alpha-lactalbumin antiserum. This immunoassay is sensitive (detection limit in reaction mixture, 1.5 micrograms/L) and could be performed in high dilution of milk, excluding any interference or sample pretreatment. It allowed the quantification of alpha-lactalbumin on a large range of concentrations (0.5-16.9 g/L) with accuracy (linear recovery in dilution-overloading assay) and precision (within- and between-run coefficients of variation from 1 to 7%). Changes in the alpha-lactalbumin concentration of human milk during lactation were determined in 162 samples. The concentration and ratio of alpha-lactalbumin total protein were found to be significantly lower in colostrum (4.9 g/l, 27%) than in transitional milk (5.2 g/L, 40%), then decreased in mature milk (3.4 g/L, 31%).

Binding, Competitive↗

Microparticle-enhanced nephelometric immunoassay of lactoferrin in human milk.

A microparticle-enhanced nephelometric immunoassay was developed for lactoferrin quantitation in human milk. It is based on the nephelometric measurement of the light scattered during the competitive immuno-agglutination of a microparticle-lactoferrin conjugate with an antilactoferrin antiserum. This immunoassay is sensitive (detection limit in reaction mixture, 0.2 mg/L) and can be performed in diluted milk (1/3,000 in reaction mixture), excluding any interference or sample pretreatment. It allowed the quantification of lactoferrin on a large range of concentrations (0.675-21.6 g/L) with accuracy (linear recovery in dilution-overloading assay) and precision (within- and between-run coefficients of variation from 3% to 6%). Changes in the lactoferrin concentration of human milk during lactation were determined in 190 samples. The concentration and ratio of lactoferrin vs. total protein were found to be significantly higher in colostrum (5.9 g/l, 29%) than in transitional milk (2.9 g/L, 22%) or mature milk (2.5 g/L, 24%).

Colostrum↗

Microparticle-enhanced nephelometric immunoassay of human plasminogen.

A microparticle-enhanced nephelometric immunoassay was developed for plasminogen quantitation in human plasma. It is based on the nephelometric measurement of the light scattered by microparticle clusters formed during a sandwich reaction between plasminogen, microparticle--anti-plasminogen conjugate, and the free antibodies of anti-plasminogen rabbit antiserum. This immunoassay was sensitive (detection limit in reaction mixture, 34 micrograms/L) and could be performed in 500-fold diluted human plasma, excluding any interference or sample pretreatment. It allowed the quantitation of plasminogen on a large range of concentrations (17-550 mg/L), with a security in antigen excess reaching 1,100 mg/L, with accuracy (linear recovery in dilution-overloading assay and correlation with conventional immunonephelometry), and precision (within- and between-run coefficients of variation lower than 8%). A normal reference range from 54 to 148 mg/L (mean +/- 2 SD) was calculated from plasminogen concentration in plasma from 130 adults. Easy to perform (no washing or phase separation) and rapid (two steps of 30 minutes then 1 hour of incubation at room temperature), this microparticle-enhanced nephelometric immunoassay could be an interesting alternative method for human plasminogen quantitation.

Adult↗

Isoelectric restriction of human immunoglobulin isotypes.

The partition of human serum immunoglobulins along a pH gradient of ampholynes was investigated using the recently developed method of preparative isoelectrofocusing. Each isotype was demonstrated to display a specific pI range, with limited overlapping. IgA appear to be the most acidic serum immunoglobulins while IgG are clearly basic.

Adolescent↗

Quantitative characterization of bovine plasminogen binding to caseins.

The binding of bovine plasminogen to whole casein, alpha s-casein, beta-casein, and kappa-casein is responsible for the progressive proteolysis of milk and dairy products. A sensitive and accurate microparticle-enhanced nephelometric immunoassay was developed to measure free plasminogen after interaction between bovine plasminogen and caseins and the quantitative parameters of plasminogen/casein binding were established. Two classes of binding sites for plasminogen were found in this study on each of the investigated caseins. Their dissociation constants (Kd) were determined by varying the plasminogen concentration at pH 6.6 and performing Scatchard analysis. The two binding sites appeared to be one of high affinity (Kd = 32 nM) and the other of lower affinity (Kd > 370 nM). The number of both binding sites per casein monomer was low (0.04 to 0.53). The great propensity of casein monomers to self-associate in homopolymers where plasminogen binding sites could be hidden and in copolymers present in bovine milk in the form of whole casein micelles accounts for calculated binding sites < 1 per monomer.

Animals↗

Microparticle-enhanced nephelometric immunoassay of anti-thyroid peroxidase autoantibodies in thyroid disorders.

Crude thyroid peroxidase extracted from human thyroid microsomes was covalently bound onto polyacrylic and polyfunctional copolymerized microparticles. We observed agglutination of the thyroid peroxidase-microparticle conjugate with 13 monoclonal antibodies (mAbs) specific for epitopes on four different antigenic domains of human thyroid peroxidase (TPO; EC 1.11.1.7), after addition of anti-mouse immunoglobulins. We quantified agglutination by measuring with a specially designed nephelometer the light scattered by the conjugates. This allowed us to develop a microparticle-enhanced nephelometric immunoassay for human anti-TPO autoantibodies (aAbs) with defined epitopic specificity, based on the ability of aAbs to inhibit mAb-induced agglutination. Applied to patients with autoimmune thyroid diseases, this assay confirmed the polyclonality of anti-TPO aAbs and their preferential reactivity toward epitopes located on the A and B antigenic domains of the TPO molecule. The same specificities seem to be present in patients with Hashimoto thyroiditis or Graves disease.

Autoantibodies↗

Interactions of complement fraction C1q, fibronectin, and immunoglobulin G with polyacrylic microparticles used as solid-phase in immunoassay.

A microparticle-enhanced nephelometric immunoassay was recently described, where polyacrylic, hydrophilic, and polyfunctional microparticles are used as the solid phase. It is a one-step immunoassay based on the nephelometric quantification of microparticle agglutination. In such assays, the measurement of analytes at low concentration may be impaired by the need of using undiluted biological samples. This leads to work with high concentrations of several proteins liable to interfere with the agglutination process. In this paper, we report on a study performed with human serum and purified proteins, which were assayed by classical analytical methods. This work identified three major components of human serum specifically involved in yielding polyacrylic microparticle instability: complement fraction C1q, fibronectin, and immunoglobulins G. In this order of importance, they all showed a marked ability to be adsorbed on the microparticle's surface. Pretreatment of human serum with microparticles decreased the concentrations in C1q (82%), fibronectin (16%), and immunoglobulin G (4%) very unequally. However, it allowed the elimination of microparticle instability, consequently providing the possible use of such polyacrylic microparticles in a one-step nephelometric immunoassay of analytes at low concentration in biological samples, without washes or phase separation.

Acrylates↗

Synthesis of new hydrophilic microspheres: optimized carriers for microparticle-enhanced nephelometric immunoassays.

To optimize antigen-antibody reactions, we have synthesized chemically well-defined hydrophilic microspheres. Proteins or haptens were covalently linked to these carriers. When the microsphere conjugates were agglutinated by the corresponding antiserum, the size of the complex artificially increased during the immunological reaction. After optimizing various parameters such as the hydrophilic character, repulsion charges, and amount of antigen coupled to the microspheres, we developed a rapid and sensitive immunoassay based on laser light scattering by the complexes.

Animals↗

Microparticle-enhanced nephelometric immunoassay for human C-reactive protein.

Polyfunctional hydrophilic microspheres of 125-nm diameter can be produced by copolymerization of acrylic monomers. Purified c-reactive protein (CRP) was covalently bound to these new micropheres, and the conjugate obtained was used as reagent in a microparticle-enhanced nephelometric immunoassay for human CRP. This assay was based on the measure, with a specially designed nephelometer, of the light scattered by aggregates formed during the immunoagglutination of the conjugate with anti-CRP antiserum. Sensitive inhibition of this agglutination by free CRP (6 ng/ml) allowed CRP quantitation in highly diluted serum samples (1/500-1/2,000), excluding any interference or sample pretreatment. The CRP assay was easy to perform (no washing or phase separation), reliable (coefficients of variation ranged from 1.3% to 9.3% for within-run and between-run determinations), and accurate (mean percentage of recovery: 104%; correlation coefficients with accepted analytical methods greater than or equal to 0.97) over a large range of concentrations. The inhibition mode excluded errors in the antigen excess zone and provided total security at high concentrations.

C-Reactive Protein↗

Development of a rapid microparticle-enhanced nephelometric immunoassay for serum myoglobin in acute myocardial infarction.

A microparticle-enhanced nephelometric immunoassay was developed for myoglobin quantitation in human serum. It uses rabbit antimyoglobin serum and hydrophilic polyacrylic microparticles covalently coated with baboon myoglobin in a competitive immunoagglutination system. The level of microparticle agglutination is assessed with a specially designed nephelometer. This sensitive (45 ng/ml of myoglobin detected in serum) and accurate (coefficients of variation from 3.0% to 8.2% in precision study and linear recovery of myoglobin in overloaded sera) immunoassay was evaluated with human sera from patients suffering from acute myocardial infarction. Myoglobin levels in patient's serum on admission appeared to be correlated with clinical and biological parameters assessed in emergency wards and later. This new, rapid, and easy microparticle-enhanced nephelometric immunoassay could thus be useful in emergency conditions for the early quantitation of serum myoglobin.

Adult↗