PubMed Health⌕ Search

Biomedical subjects

P Morimont

Publications and source records attributed to P Morimont.

11 recordsLinked to original sources

Effects of U-46619 on pulmonary hemodynamics before and after administration of BM-573, a novel thromboxane A2 inhibitor.

We studied the effects on pulmonary hemodynamics of U-46619, a thromboxane A2 (TXA2) agonist, before and after administration of a novel TXA2 receptor antagonist and synthase inhibitor (BM-573). Six anesthetized pigs (Ago group) received 6 consecutive injections of U-46619 at 30-min interval and were compared with six anesthetized pigs (Anta group) which received an increasing dosage regimen of BM-573 10 min before each U-46619 injection. Consecutive changes in pulmonary hemodynamics, including characteristic resistance, vascular compliance, and peripheral vascular resistance, were continuously assessed during the experimental protocol using a four-element Windkessel model. At 2 mg/kg, BM-573 completely blocked pulmonary hypertensive effects of U-46619 but pulmonary vascular compliance still decreased. This residual effect can probably be explained by a persistent increase in the tonus of the pulmonary vascular wall smooth muscles sufficient to decrease vascular compliance but not vessel lumen diameter. Such molecule could be a promising therapeutic approach in TXA2 mediated pulmonary hypertension as it is the case in pulmonary embolism, hyperacute lung rejection and endotoxinic shock.

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5↗

Effects of BM-573, a novel thromboxane A2 inhibitor, on pulmonary hemodynamics in endotoxic shock.

Thromboxane A2 is considered to be partially responsible for the increase in pulmonary vascular resistance observed after endotoxin administration and to participate in proinflammatory reactions. The effects of a novel dual TXA2 synthase inhibitor and TXA2 receptor antagonist (BM-573) on pulmonary hemodynamics were investigated in endotoxic shock. 30 mins before the start of a 0.5 mg/kg endotoxin infusion, 6 pigs (Endo group) received a placebo infusion and 6 other pigs (Anta group) received a BM-573 infusion. In Endo group, pulmonary artery pressure increased from 25 +/- 1.8 (T0) to 42 +/- 2.3 mmHg (T60) (p < 0.05) after endotoxin infusion while, in Anta group, it increased from 23 +/- 1.6 (T0) to 25 +/- 1.5 mmHg (T60). This difference is due to a reduction in pulmonary vascular resistance in Anta group while pulmonary arterial compliance changes in Endo group remained comparable with the evolution in Anta group. In Endo group, PaO2 decreased from 131 +/- 21 (T0) to 74 +/- 12 mmHg (T300) (p < 0.05), while in Anta group, PaO2 was 241 +/- 31 mmHg at the end of the experimental period (T300). These results demonstrate that TXA2 plays a major role in pulmonary vascular changes during endotoxin insult. Concomitant inhibition of TXA2 synthesis and of TXA2 receptors by BM-573 inhibited the pulmonary vasopressive response during the early phase of endotoxin shock as well as the deterioration in arterial oxygenation.

Animals↗

Effect of hemodiafiltration on pulmonary hemodynamics in endotoxic shock.

Hemofiltration can improve pulmonary hemodynamics during septic shock. The main objective of the study was to determine whether hemodiafiltration (HDF) would also have beneficial effects on pulmonary hemodynamics during septic shock. In the Endo group, six anesthetized pigs received a 0.5 mg/kg endotoxin infusion over 30 min. In the HDF group (n = 6), HDF was started 30 min after the end of the endotoxin infusion, while in the Control group (n = 4) they received HDF but no endotoxin infusion. Pulmonary hemodynamics were analyzed in detail with a four-element windkessel model. Although in the Control group, HDF did not alter pulmonary hemodynamic parameters, in the HDF group, it was responsible for an amplification of the deleterious pulmonary vascular response to endotoxin insult. Our results show that HDF must be used cautiously in septic shock since it can precipitate right heart failure by increasing pulmonary vascular resistance.

Animals↗

Alteration of left ventriculo-arterial coupling and mechanical efficiency during acute myocardial ischemia.

AIM: Myocardial revascularisation being frequently performed during acute myocardial ischemia, in a hostile hemodynamic environment, we evaluated left ventriculo-arterial (VA) coupling, left ventricular (LV) mechanical efficiency, and the mechanical properties of the systemic vasculature during acute myocardial ischemia. METHODS: In 6 pigs, vascular properties [characteristic impedance (R(1)), peripheral resistance (R(2)), compliance (C), inductance (L), arterial elastance (E(a))] were estimated with a windkessel model. LV function was assessed by the slope (E(es)) of end-systolic pressure-volume relationship (ESPVR), and stroke work (SW) - end-diastolic volume (EDV) relation. Pressure-volume area (PVA) was referred to as myocardial oxygen consumption. VA coupling was defined as E(es)/E(a), and mechanical efficiency as SW/PVA. After baseline recordings, the left anterior descending coronary artery was ligated and hemodynamic measures obtained every 30 minutes for 3 hours. Data are expressed as mean (SEM). RESULTS: Coronary occlusion induced an ESPVR rightward shift, and decreased E(es) from 3.67 (0.33) to 1.92 (0.20) mmHg/ml and the slope of the SW - EDV relationship from 72.3 (3.4) to 40.4 (4.5) mmHg (p<0.001), while E(a) increased from 3.33 (0.56) to 4.65 (0.29) mmHg/ml (p<0.005). This was responsible for a dramatic alteration of VA coupling from 1.22 (0.11) to 0.44 (0.07), (p<0.001). While R2 increased from 1.72 (0.30) to 2.38 (0.16) mmHg x s x ml(-1) (p<0.05) and C decreased from 0.78 (0.16) to 0.46 (0.08) ml/mmHg (p<0.05), R(1) and L were unchanged. Coronary occlusion decreased SW from 4056 (223) to 2580 (122) mmHg.ml (p<0.001), while PVA and SW/PVA decreased from 5575 (514) to 4813 (317) mmHg x ml (NS), and from 0.76 (0.04) to 0.57 (0.03) (p<0.001), respectively. CONCLUSION: Acute myocardial ischemia severely altered left ventriculo-arterial coupling and LV mechanical efficiency. Impaired left VA coupling was due to a combination of augmented arterial elastance, secondary to early vasoconstriction later associated with decreased arterial compliance, and decreased LV contractility.

Animals↗

[Auricular zona].

Explore the source record for details and available documents.

Aged↗