PubMed Health⌕ Search

Biomedical subjects

P N Taylor

Publications and source records attributed to P N Taylor.

At least 19 recordsLinked to original sources

The functional form of the lognormal distribution as a sum of decaying exponential and sinusoidal terms applied to the isometric pinch force of human fingers.

The transient data of the pinch force produced between the human forefinger and thumb have been shown to fit the functional form of the well-known lognormal density function. Isometeric force generation is achieved by the stochastic recruitment of individual motor units, which sum together. Evidence from animal and human experiments demonstrates that the force generation can be modelled by underdamped terms. It is shown that a lognormal time series (distribution) can be fitted to a sum of exponential decaying sinusoidal terms.

Electric Stimulation↗

A microcontroller system for investigating the catch effect: functional electrical stimulation of the common peroneal nerve.

Correction of drop foot in hemiplegic gait is achieved by electrical stimulation of the common peroneal nerve with a series of pulses at a fixed frequency. However, during normal gait, the electromyographic signals from the tibialis anterior muscle indicate that muscle force is not constant but varies during the swing phase. The application of double pulses for the correction of drop foot may enhance the gait by generating greater torque at the ankle and thereby increase the efficiency of the stimulation with reduced fatigue. A flexible controller has been designed around the Odstock Drop Foot Stimulator to deliver different profiles of pulses implementing doublets and optimum series. A peripheral interface controller (PIC) microcontroller with some external circuits has been designed and tested to accommodate six profiles. Preliminary results of the measurements from a normal subject seated in a multi-moment chair (an isometric torque measurement device) indicate that profiles containing doublets and optimum spaced pulses look favourable for clinical use.

Ankle Joint↗

Electrical stimulation of abdominal muscles for control of blood pressure and augmentation of cough in a C3/4 level tetraplegic.

OBJECTIVES: Evaluation of a FES (Functional Electrical Stimulation) device for the relief of postural hypertension and augmentation of cough in a C3 ventilator-dependent tetraplegic. STUDY DESIGN: A single case study. SETTING: A supra regional spinal unit in the UK. METHOD: A dual channel stimulator was designed that allowed selection and initiation of two predetermined stimulation intensities using a chin controlled joystick. Two sets of 70 mm diameter electrodes were placed either side of the abdomen. Approximately 80 mA, 300 micros, 40 Hz was required for assisted cough while about 40 mA was required for maintenance of blood pressure. After eating, the lower level stimulus is self-administered every 3 to 5 min gradually increasing the time between groups of burst to once every hour after 90 min. RESULTS: Following eating, a blood pressure of 60/45 mmHg was recorded. After five 1 s bursts of stimulation in quick repetition, this was increased to 133/92 mmHg. After 2 min blood pressure had fallen to 124/86 mmHg and to 93/66 after a further 4 min. The electrical stimulation was then repeated, returning the blood pressure to the previous higher level. Measurement of peak expiratory flow showed an increase from 275 l/min for an unassisted cough to 425 l/min when using the device. CONCLUSION: The device is used every day. The user is now independent in coughing function and no longer requires suction or manual assistance. Maintenance of blood pressure has significantly improved his quality of life.

Abdominal Muscles↗

Indices to describe different muscle activation patterns, identified during treadmill walking, in people with spastic drop-foot.

This study was concerned with individuals who were unable to effectively dorsiflex their ankle when walking, as a result of a lesion of the central nervous system (CNS). Indices that categorise and quantify different patterns of calf and anterior tibial muscle activation patterns during treadmill walking have been derived from a sample of fifteen individuals with established hemiplegia following stroke and twelve age-matched individuals without impairment. As subjects walked on a treadmill, force sensitive foot-switches under the heel and first metatarsal head allowed EMG signals from the calf and anterior tibial muscles to be related to phases of the gait cycle. Normal activation periods for each muscle group were identified as percentiles of the gait cycle and indices for muscle activation periods were derived using ratios of integrated EMG during selected periods. Indices were derived that identified statistically significant differences, between normal and hemiplegic subjects, in calf activation during both push-off phase (P<0.001) and early stance phase (P<001), but not activation of tibialis anterior during swing (P=0.325) Observation suggested that integrated tibialis anterior activity during swing phase in hemiplegic subjects was not dissimilar to normal subjects, but the profile in hemiplegic subjects tended to lack the normal second peak of activity at initial foot contact. The reasons for drop-foot were shown to be varied and complex. The indices defined may be useful for directing therapy and measuring outcome.

Adolescent↗

Restoration of tetraplegic hand function by use of the neurocontrol freehand system.

Nine tetraplegic patients with C5 or C6 level spinal cord lesions had the Freehand System, an eight channel Functional Electrical Stimulation device, implanted to allow of hand opening and grasp. This paper describes the surgical implementation of the system and the challenges encountered. Seven of the subjects are currently daily users of the device. One subject is unable to use the system due to disruption of bowel function when the system is used. A second subject suffered a lesion of the posterior interosseous nerve, but this was not thought to be related to system use. Additionally, one subject exhibited symptoms of autonomic dysreflexia, which were alleviated by reduction of the strength of the stimulus. Despite such problems, the Freehand system can significantly improve the functional ability of C5 and C6 lesion tetraplegics.

Activities of Daily Living↗

Clinical use of the Odstock dropped foot stimulator: its effect on the speed and effort of walking.

OBJECTIVE: To assess the clinical effectiveness of the Odstock dropped foot stimulator by analysis of its effect on physiological cost index (PCI) and speed of walking. This functional electrical stimulation (FES) device stimulates the common peroneal nerve during the swing phase of gait. DESIGN: A retrospective study of patients who had used the device for 4 1/2 months. SUBJECTS: One hundred fifty-one patients with a dropped foot resulting from an upper motor neuron lesion. SETTING: A medical physics and biomedical engineering department of a district general hospital specializing in the clinical application of FES and a neurophysiotherapy department at a separate hospital. MAIN OUTCOME MEASURES: Changes in walking speed and effort of walking, as measured by PCI over a 10-meter course. RESULTS: There was a 92.7% compliance with treatment. Stroke patients showed a mean increase in walking speed of 27% (p<.01) and reduction in PCI of 31% (p<.01) with stimulation, and changes of 14% (p<.01) and 19% (p<.01), respectively, while not using the stimulator. Multiple sclerosis patients gained similar orthotic benefit but no "carry-over." CONCLUSIONS: The measured differences in walking with and without stimulation were statistically significant in the stroke and multiple sclerosis groups. In this study use of the stimulator improved walking. Those with stroke demonstrated a short-term "carry-over" effect.

Adult↗

Long pulse biphasic electrical stimulation of denervated muscle.

In recent years a number of studies have employed long pulse biphasic stimulation as a treatment for denervated muscle to improve tissue quality and in some cases to improve contractile capability sufficient to restore function. However, in the U.K., this treatment is yet to be widely adopted clinically. A 5 subject, case based pilot study of long pulse biphasic direct stimulation of peripheral limb denervated muscle is being conducted and its effect on the tissue evaluated by measurement of muscle bulk, limb blood flow, and skin temperature. In cases of partial denervation. trapezoidal shaped pulses are used to minimize sensory and motor nerve fiber recruitment.

Arm↗

Patients' perceptions of the Odstock Dropped Foot Stimulator (ODFS).

OBJECTIVE: To determine the perceived benefit, pattern and problems of use of the Odstock Dropped Foot Stimulator (ODFS) and the users' opinion of the service provided. DESIGN: Questionnaire sent in a single mailshot to current and past users of the ODFS. Returns were sent anonymously. SETTING: Outpatient-based clinical service. SUBJECTS: One hundred and sixty-eight current and 123 past users with diagnoses of stroke (CVA), multiple sclerosis (MS), incomplete spinal cord injury (SCI), traumatic brain injury (TBI) and cerebral palsy (CP). INTERVENTION: Functional electrical stimulation (FES) to correct dropped foot in subjects with an upper motor neuron lesion, using the ODFS. MAIN OUTCOME MEASURES: Purpose-designed questionnaire. RESULTS: Return rate 64% current users (mean duration of use 19.5 months) and 43% past users (mean duration of use 10.7 months). Principal reason cited for using equipment was a reduction in the effort of walking. Principal reasons identified for discontinuing were an improvement in mobility, electrode positioning difficulties and deteriorating mobility. There were some problems with reliability of equipment. Level of service provided was thought to be good. CONCLUSION: The ODFS was perceived by the users to be of considerable benefit. A comprehensive clinical follow-up service is essential to achieve the maximum continuing benefit from FES-based orthoses.

Adult↗

Selecting candidates for a lower limb stimulator implant programme: a patient-centred method.

OBJECTIVE: To develop an effective selection procedure for lower limb functional neurostimulation (LLFNS) for standing in paraplegia. DESIGN: The selection procedure and exclusion criteria were based on the previous experience for two clinical centres with experience of LLFNS. SETTING: Two Regional Spinal Injuries units in southern England. SUBJECTS: 254 fully rehabilitated paraplegics living in the community. INTERVENTION: Patients were invited to participate in the programme, and if suitable to subject themselves to a rigorous staged selection procedure from which they could withdraw at any time. OUTCOME MEASURE: Functionally successful home standing using closed-loop surface electrical stimulation. RESULTS: 57/254 patients were suitable on paper and were accessible. 19 of these (CI = 10-28) were interested in the project and attended one of the spinal centres for details. Twelve (CI = 5-19) of these fulfilled the selection criteria and started on the training programme; and 10 of them completed the muscle training programme successfully. Seven patients (CI = 2-12) achieved closed-loop standing in the laboratory and four patients (CI = 1-8) did so at home.

Adult↗

Correlation of ATP/citrate lyase activity with lipid accumulation in developing seeds of Brassica napus L.

The temporal distribution of ATP/citrate lyase (ACL) activity in developing seeds of Brassica napus L. closely paralleled both that of acetyl-CoA carboxylase and the overall rate of lipid biosynthesis. Maximum ACL activities (250 nmol acetyl-CoA formed min-1.g fresh seed) were recorded between 35 to 42 d after pollination and, if the in vitro data could be extrapolated to the situation in vivo, could account for half of the acetyl-CoA required for the measured rate of fatty acid biosynthesis during seed development. The enzyme appeared to be localized in a subcellular compartment, which was clearly separated from mitochondria on a sucrose gradient and by differential centrifugation, and which corresponded to the chloroplast organelle.

ATP Citrate (pro-S)-Lyase↗

Lumbar root stimulation for restoring leg function: results in paraplegia.

We have implanted an intradural array of 12 tripolar electrodes on the anterior roots L2-S2, left and right, at cauda equina level, in a 33-year-old woman with a complete T9 cord lesion of 3 years' duration. They are driven by an implanted multiplexed stimulator system using radio frequency (RF) power and control signals. All channels generate movements, in patterns that might be predicted from the known anatomy of the cauda equina. In particular, stimulation of L2 and L3 gives hip adduction; L3, L4, and L5 gives quadriceps femoris movements; L5, S1, and S2 gives hamstrings movement; and S1 and S2 give plantar flexion. Stimulation of L5 gives mixed movements at the ankle. Surprisingly, stimulation of the L2 roots has not given strong hip flexion. Responses have been stable. Some thresholds have varied, probably as a result of tissue encapsulation. The moment generated within each degree of freedom of the legs has been measured for each root, using a specially designed multimoment measurement apparatus. For several roots, a movement of lower threshold may be accompanied by a second movement of higher electrical threshold, suggesting that different muscles may have fiber populations that differ in their diameter or their location in the root. The use of stimulus forms that enable selective anodal block may, in the future, enable separation of two distinct movements from a single motor root.

Adult↗

The effects of common peroneal stimulation on the effort and speed of walking: a randomized controlled trial with chronic hemiplegic patients.

OBJECTIVE: To measure the effect of the Odstock Dropped Foot Stimulator (ODFS), a common peroneal stimulator, on the effort and speed of walking. DESIGN: A randomized controlled trial. SUBJECTS: Hemiplegic patients who had suffered a single stroke at least six months prior to the start of the trial whose walking was impaired by a drop-foot. INTERVENTIONS: The treatment, functional electrical stimulation (FES) group, used the stimulator and received a course of physiotherapy; the control group received physiotherapy alone. MAIN OUTCOME MEASURES: Changes in walking speed measured over 10 m and the effort of walking measured by physiological cost index (PCI). RESULTS: Thirty-two subjects completed the trial, 16 in the FES group and 16 in the control group. Mean increase in walking speed between the beginning and end of the trial was 20.5% in the FES group (when the stimulator was used), and 5.2% in the control group. Improvement was also measured in PCI with a reduction of 24.9% in the FES group (when the stimulator was used) and 1% in the control group. No improvement in these parameters was measured in the FES group when the stimulator was not used. CONCLUSION: Walking was statistically significantly improved when the ODFS was worn but no 'carry-over' was measured. Physiotherapy alone, in this group of subjects with established stroke, did not improve walking.

Aged↗

Limb blood flow, cardiac output and quadriceps muscle bulk following spinal cord injury and the effect of training for the Odstock functional electrical stimulation standing system.

As part of the assessment of the Odstock functional electrical stimulation (FES) standing system for mid to low thoracic lesion spinal cord injured (SCI) subjects, cardiac output, high blood flow and quadriceps muscle thickness were measured before and following an electrical stimulation muscle retraining programme. The same parameters were also measured in a group of uninjured subjects and in SCI subjects. It was found that there was no difference in cardiac output between the groups. However thigh blood flow was found to be around 65% of normal values in the spinally injured group. This returned to normal values following the retraining programme. The quadriceps muscle wasted to approximately 50% of its original thickness in the first 3 weeks following spinal cord injury. The retraining programme increased the muscle thickness to near normal values.

Adult↗

Characterisation of saporin genes: in vitro expression and ribosome inactivation.

A. Saponaria (soapwort) genomic library was screened with a PCR-derived saporin-specific gene probe. The nucleotide sequences of three saporin genomic clones were determined. One of the clones contained a full-length saporin coding sequence whilst the other two were truncated. A hybrid full-length saporin coding sequence was constructed using the two truncated clones. An SP6 promoter sequence and in-frame initiation codon was added to each of the coding sequences using PCR. In vitro translation of saporin coding sequence transcripts in rabbit reticulocyte lysates resulted in the specific depurination of 28S RNA. This indicated that the saporin sequences encoded functional polypeptides with RNA N-glycosidase activity.

Amino Acid Sequence↗

Use of air in double contrast barium enema--is it still acceptable?

There is conflicting evidence regarding the benefit of using carbon dioxide in a double contrast barium enema. In a double blind prospective study, 200 patients undergoing out-patient double contrast barium enemas (DCBE) were randomly allocated to receive either air or carbon dioxide (CO2) insufflation. After 24 h they were requested to complete and return a questionnaire regarding abdominal pain and distension experienced following the examination. The use of CO2 reduced the incidence of severe post-DCBE pain from 27% to 7%. There was a higher incidence of severe pain in younger patients, regardless of which gas was used. The incidence of severe pain following DCBE was unrelated to the presence or absence of abdominal pain as part of the patient's symptomatology. In the light of these findings we advocate the routine use of CO2 in DCBE.

Abdominal Pain↗

Practical low cost stand/sit system for mid-thoracic paraplegics.

The use of functional electrical stimulation (FES) to enable paraplegics to stand is not new or indeed difficult to undertake under laboratory conditions. However, there are substantial problems to overcome before such systems can be used routinely by patients without professional supervision. The overriding consideration has to be one of safety, i.e. the system must be 'fail safe'. Secondly, the system must be quick and easy to use in a wide variety of locations, otherwise it will not provide any increase in function. Finally, it must be inexpensive enough to be available to a large number of paraplegics. The primary aim of our work was to provide such a system to enable mid-thoracic lesion paraplegics to stand wherever they wish. This involved the development of a microprocessor-based stimulator to enable the stimulating envelope to be individually tailored to a given patient's requirements and the provision of closed loop control to minimize fatigue. A folding standing frame was also designed which replaces the arm rests on a standard wheelchair. Using this system, the user is able to stand within 30 s of stopping and can remain standing for up to 10 min. Cosmetic calipers (knee-ankle-foot orthoses) are also being used for paraplegics who require to stand for longer periods. It is hoped that such a system will provide stable standing for a large number of paraplegics at a unit cost of approximately 750 pound.

Electric Stimulation↗