P N Wells

Publications and source records attributed to P N Wells.

At least 19 recordsLinked to original sources

Physics and engineering: milestones in medicine.

The history of the development of the applications of physics and engineering in medicine provides an insight into contemporary practice and can help to mould the future. Physics and engineering form a continuum, and, in the present context, engineering is indistinguishable from applied physics. The modern scientific era, which extends over 500 years, is characterised by numerous significant developments: for example, the Nobel prizes which most closely relate to physics and engineering in medicine were for X-rays and radioactivity, the electrocardiogram, the scattering of radiation, the cyclotron, nuclear magnetic resonance, the transistor, radioimmunoassay and computed tomography; and a medical physicist has received the Peace Prize. The origins and development of nuclear medicine, magnetic resonance and ultrasonic imaging are representative of the whole field. Physics and engineering rank alongside other medical sciences and underpin many of their applications. In what is now the developed world, human life expectancy has increased dramatically, but the costs and risks of modern medicine have meanwhile become a huge problem. The growing divergence of rich and poor is now arguably the greatest challenge. The future cannot be predicted, but the potential of physics and engineering to improve medicine has never been greater.

Biomedical Engineering↗

Continuous wave ultrasonic tomography.

As an object rotates with respect to a stationary ultrasonic beam, the scattering centers within the object return echoes that are Doppler-shifted in frequency by amounts depending on the velocities of the individual scatterers. The scattering centers that lie on a line of constant cross-range all have the same effective velocity in the direction pointing toward the transducer; therefore, the backscattered echo amplitude at any particular frequency is the line integral of the scattered radiation at the cross-range corresponding to that frequency. The amplitudes of the returned signals at other frequencies give the line integrals for the scatterers at the corresponding cross-ranges. The amplitude as a function of frequency can be interpreted as a tomographic projection. A continuum of the projections at different positions is generated while the object is rotating. A tomographic reconstruction algorithm can produce an image of the distribution of scattering centers in the insonified object from these projections. A microscanner was developed to investigate the approach of using continuous wave (CW) ultrasound for cross-sectional imaging. The resolution is limited by the target size and the ultrasonic wavelength.

Algorithms↗

Advances in ultrasound: from microscanning to telerobotics.

This paper is in memory of W V Mayneord (1902-1988). Experiments conducted in Mayneord's laboratory were amongst the first to show that ultrasound had diagnostic potential. Now, one in every four imaging studies uses ultrasound. Amongst numerous contemporary advances, microscanning is concerned with imaging subcentimetre size volumes of tissue in three dimensions with 10-100 microns resolution. The traditional approach is by pulse echo imaging, with a focused ultrasonic beam in the frequency range 20-100 MHz. This approach may be complemented by ultrasonic CT (to correct for attenuation and speed variations), reflex transmission imaging (to provide attenuation data) and synthetic aperture scanning (to decrease imaging time). Harmonic microscanning may reduce artefacts, and elasticity imaging may also be possible. Microscanning is likely to have applications in pathology and in the operating room, for trackless microintervention, in molecular biology and drug studies, and in experimental imaging of small mammals including, in particular, the mouse. Robotics is the engineering science concerned with devices that are able to execute tasks usually performed by humans. Two procedures, ultrasonically guided biopsy and ultrasonic laparoscopy, are being used to demonstrate the feasibility of telerobotics. The approach is that of telepresence, as distinct from supervisory control or virtual reality. Problems associated with image compression and communications latency are identified. Although incremental developments in medical ultrasound have resulted from clinical pull, major advances have, in general, been due to technical push.

England↗

Ultrasound in vascular pathologies.

The choice of the optimal ultrasonic frequency for vascular studies is determined by the required resolution and penetration. Anatomical real-time two-dimensional imaging and blood flow studies provide complementary information. Intravascular scanning allows high-frequency ultrasound to be used, with correspondingly good spatial resolution. Contrast resolution is degraded by beam side lobes and the limited dynamic range of the ultrasonic pulse. The physics of ultrasonic scattering by blood, pulsed Doppler and duplex scanning and colour flow imaging performances determines the limits of clinical applications. Contrast agents enhance the echogenicity of blood, improving sensitivity and, through second harmonic detection, suppressing solid tissue echoes. Three-dimensional display, with segmentation by the presence of the flow signal, facilitates spatial perception. Clinical applications in vascular pathologies are summarised.

Blood Flow Velocity↗

Doppler studies of the vascular system.

Ultrasonic Doppler methods are routinely used to study the vascular system. Flow and tissue motion information can be obtained by frequency and time domain processing. Instruments range in complexity from simple continuous wave devices without imaging capability through to advanced real-time 2D colour flow scanners and intravascular devices. 3D display is also possible. Contrast agents can be used to increase the detectability of blood flow signals. The properties of the tissue impose an envelope on achievable ultrasonic imaging. Doppler studies can provide information about flow velocity profile, vessel compliance, wall shear rate, pressure gradient, perfusion, tumour blood flow and the presence of emboli. These capabilities can be integrated in an holistic picture of ultrasonic vascular studies.

Cardiovascular System↗

Splanchnic blood flow in patients with cirrhosis and portal hypertension: investigation with duplex Doppler US.

PURPOSE: To investigate splanchnic blood flow changes in patients with hepatic cirrhosis and portal hypertension. MATERIALS AND METHODS: Duplex Doppler ultrasound (US) was used to measure blood flow in the superior mesenteric artery (SMA) and splenic artery in 20 patients with biopsy-proved cirrhosis and clinical evidence of portal hypertension, and in 20 healthy volunteers who were matched for age and sex. RESULTS: Mean SMA and splenic artery blood flow was significantly greater in the patients than in healthy subjects. Neither SMA nor splenic artery blood flow was increased in patients with normal-sized spleens; however, blood flow was significantly elevated in patients with splenomegaly. Total splanchnic blood flow in patients was also significantly elevated compared with healthy subjects. Total splanchnic blood flow in patients with normal-sized spleens was not significantly elevated compared with healthy subjects, but splanchnic flow was significantly increased in patients with splenomegaly. CONCLUSION: Blood flow is increased in the SMAs and splenic arteries of patients with cirrhosis and portal hypertension. Increased splanchnic blood flow associated with cirrhosis may occur exclusively in patients with splenomegaly.

Blood Flow Velocity↗

Ultrasonic colour flow imaging.

Real-time ultrasonic colour flow imaging, which was first demonstrated to be feasible only about a decade ago, has come into widespread clinical use. Ultrasound is scattered by ensembles of red blood cells. The ultrasonic frequency that gives the best signal-to-noise ratio for backscattering from blood depends on the required penetration. The frequency of ultrasound backscattered from flowing blood is shifted by the Doppler effect. The direction of flow can be determined by phase quadrature detection, and range selectivity can be provided by pulse-echo time-delay measurements. The Doppler frequency spectrum can be determined by Fourier analysis. Early two- and three-dimensional flow-imaging systems used slow manual scanning; velocity colour coding was introduced. Real-time colour flow imaging first became feasible when autocorrelation detection was used to extract the Doppler signal. Time-domain processing, which is a broad-band technique, was also soon shown to be practicable, for analysing both radio-frequency pulse-echo wavetrains and two-dimensional image speckle. Frequency- and time-domain processing both require effective cancellation of stationary echoes. The time-domain approach seems to have advantages in relation to both aliasing and the effects of attenuation in overlying tissues. Colour-coding schemes that can be interpreted without the need to refer to keys have been adopted, for both velocity and flow disturbance. Colour coding according to signal power has also been reintroduced. Three-dimensional display has been demonstrated. In interpreting colour flow images, it is important to understand the functions of critical system controls and the origins of artifacts. Various strategies can be adopted to increase the image frame rate. The problems of performance measurement and safety need to be kept under review. There are numerous opportunities for further development of ultrasonic colour flow imaging, including improvements in system design, methods of image display, the use of contrast agents and the solution of previously unexplored clinical problems.

Blood Flow Velocity↗

Phantoms for studying the acceleration and turbulence of liquids using magnetic resonance imaging.

Magnetic resonance angiography is a relatively new method used to image vascular structure. However, a limitation manifested through signal loss due to non-stable flow makes this technique unreliable for directly visualizing occlusions and estimating the degree of stenosis. In this study, a quantitative approach is developed to understand further the situations where signal loss occurs and a phase mapping technique is used quantitatively to study acceleration in test objects designed to generate flow disturbance. In regions of acceleration the correlation coefficient between magnetic resonance imaging velocity and the inverse of area was r > 0.999 (p < 0.001). The range of acceleration calculated was 6514-63,053 mm s-2 and at maximum acceleration the measured velocity had a systematic error of 4.0(+/- 2.0)% and coefficient of variation of 3.1%. Test objects were devised and utilized for demonstrating non-stable flow and jet formation with comparison being made to predictions from fluid dynamics theory.

Acceleration↗

Milestones in cardiac ultrasound: echoes from the past. History of cardiac ultrasound.

Although the antecedents of cardiac ultrasound can be traced back to the 1870s, it was in 1954 that Edler and Hertz published their milestone paper. M-mode echocardiography reached its peak in the early 1970s, when the fibre-optic recorder made the method clinically viable. It was not long before real-time two-dimensional imaging was developed, however, and the invention of pulsed Doppler laid the foundation of duplex scanning. In 1985, colour flow imaging gave a fresh impetus to echocardiography. In parallel with the main developments, intravascular and transoesophageal scanning have gained clinical popularity within the last decade, together with techniques for the display of three-dimensional images. Other innovations include contrast agents, pressure gradient measurement and promising methods for tissue characterisation. It seems that current techniques are safe, but this needs to be kept continuously under review.

Echocardiography, Doppler↗

The present status of ultrasonic imaging in medicine.

The ultrasonic techniques that are used routinely in medical imaging have resulted from basic scientific discoveries, new methods of signal analysis and image processing, the development of transducer materials and fabrication techniques, and the application of digital electronics. The system designer is constrained by the ultrasonic properties of tissues, especially speed and attenuation: these properties determine the optimum choices of ultrasonic frequency, and spatial contrast and temporal resolutions. Ultrasonic Doppler techniques provide information about moving targets, including blood flow. Two-dimensional images of anatomical structure and blood flow can be combined in real-time displays. Other advances include sonoelasticity imaging, computed tomography, three-dimensional imaging, contrast agents and quality assurance. Contemporary ultrasonic diagnostic techniques seem to be safe, but the search for possible hazards is continuing with emphasis on thermal effects and cavitation.

Blood Flow Velocity↗

An image processing technique for the identification of contact pixels applied to x-ray CT images of implanted hip prostheses.

Uncemented prosthetic joint implants used in orthopaedic surgery are usually coated with a porous surface to encourage bone ingrowth. Better contact between the endosteal bone and the porous surface improves ingrowth, and such contact may be increased if the joint further subsides into position in the first weeks following implantation. An image processing technique has been developed as part of a study undertaken to determine the effect of early subsidence on endosteal contact. The method provides a measure of the degree of contact between the surfaces from transverse x-ray CT images, but is suitable for application to any image with a similar intensity distribution.

Hip Prosthesis↗

The development of equipment for the technical assessment of respiratory motion induced artefacts in MRI.

A device and technique to study the effects of respiratory motion on the quality of magnetic resonance images is proposed. The construction of the device enables a variety of test objects to be mounted and used in the evaluation of imaging parameters that may be affected by motion. The equipment is constructed of cast acrylic and the movement is actuated and controlled pneumatically thus ensuring that there are no interactions with the magnetic field and radiofrequency detection system to cause further image artefacts. Separate studies have been performed, using ultrasound, to assess the degree and rate of movement of organs owing to respiration in order to derive the motion parameters for the apparatus. Preliminary results indicate that the technique produces motion induced artefacts simulating those which are the result of the effects of respiration.

Diaphragm↗

A comparative study of velocity measurements in major blood vessels using magnetic resonance imaging and Doppler ultrasound.

Velocity measurements in major blood vessels were obtained in studies of volunteers using magnetic resonance imaging (MRI) and compared with Doppler ultrasound (US). The vessels studied were the abdominal aorta, superior mesenteric artery, common carotid artery, superficial femoral artery and middle cerebral artery. Using a paired t-test, no significant difference was found between velocity values estimated by MRI and US (p > 0.08). The relative advantages of each technique in radiological practice are discussed.

Adult↗

Ultrasonics: a window into biomedical science.

Ultrasonics has always been concerned with biomedical research. When the journal started, most applications were in therapy and surgery, but diagnosis soon became dominant. Many key developments received early publication: these included Doppler ultrasound, real-time imaging, tumour neovascularization and, arguably most significant of all, phased array scanning. Now in its thirtieth year of publication, Ultrasonics has contributed greatly to the development of biomedical science and it promises to have an important continuing role.

History, 20th Century↗

Estimation of total hepatic blood flow by duplex ultrasound.

The volume flow rate of blood in the portal vein and the hepatic artery was measured using a duplex ultrasound system. Two sections of the hepatic artery were studied; the common hepatic artery where measurements were made just after the bifurcation of the coeliac axis to splenic and hepatic arteries and the hepatic artery itself, where measurements were made just proximal to the porta hepatis in a straight stretch of artery overlying the portal vein. Total hepatic blood flow was taken as the sum of hepatic artery and portal vein flows. A group of 10 normal healthy volunteers in the fasting state was studied. The mean (SD) volume blood flow in the vessels was measured to be: hepatic artery 3.5 (45%) ml/min/kg, common hepatic artery 6.9 (30%) ml/min+/kg, portal vein 13.5 (21%) ml/min/kg, total hepatic flow 17.0 (16%) ml/min/kg.

Blood Flow Velocity↗