Transpupillary laser phototherapy of tumors and vascular anomalies of retina and choroid: theoretical approach and clinical implications.

BACKGROUND: Small retinal and choroidal tumors situated near the optic nerve or macula, such as retinoblastomas and malignant melanomas, as well as various other anomalies, in particular vascular malformations, may successfully be treated by photocoagulation. Model assumptions geared towards maximizing efficiency and minimizing undesirable side effects are forwarded, and the most important parameters subserving photothermal destruction, such as radiation field and thermal energy, analyzed. The influence exerted by physical traits of various tissues involved are also considered. METHODS: The model approximations presented are based on classical radiation and absorption laws, as well as on the scattering properties of the various tissues implicated, these being considered as a function of wavelength and their relevance to the photodestructive task at hand. Particular attention is paid to the rate processes and reaction kinetics of irradiated proteins. CONCLUSIONS: Radiation sources emitting in the near-infrared range of the electromagnetic spectrum, such as the diode (810 nm) and the cw Nd:YAG (1064 nm) lasers, are optimal for the treatment of tumors and large, voluminous entities (such as Hippel-Lindau angiomas), owing to the good tissue penetration properties of their light. Those emitting in the shorter wavelength range, such as the argon ion (488 and 514 nm) and first harmonic--mode Nd:YAG (532 nm) lasers, are not suitable for such tasks, but they are ideal for the destruction of fine sanguinous structures, within which their light is strongly absorbed but through which it penetrates poorly. For the treatment of large anomalous structures, a combined short/long wavelength--strategy should also be considered as a viable alternative. Such a "wavelength mixture" is emitted by the xenon high pressure lamp of the once renowned Meyer-Schwickerath light coagulator. The precision and safety of photothermal destruction methods depend, in the first approximation, upon the details of the pulse energy deposition (wavelength, pulse height and duration, pulse dynamics, mode composition, focussing), the choice of which is determined by the optical and thermal constants of the irradiated tissues. Higher pulse energies will, of course, be more effective in destroying neoplastic cells, but the risk of producing undesired collateral heat damage will also increase concomitantly. Until we can ascertain the physical properties of the pathological tissues treated with certainty, we will hardly be able to achieve more than an approximation of an ideal treatment strategy. But with increasing developments in in vivo-diagnostic techniques, we expect that this goal will be attainable in the not too distant future.

Animals↗

Material characterization of the pig kidney in relation with the biomechanical analysis of renal trauma.

The objective of this study was an investigation of the material properties of the fresh pig kidney and parametric characterization of its elastic and inelastic material behavior. The material investigation included density measurements, uniaxial as well as three-dimensional compression tests, tensile tests. and shear tests on the samples extracted from the fresh pig kidney. For comparison, density measurements on a number of soft synthetic materials were also performed. Compression tests on the radial and the tangential specimens from the cortex tissue were performed at various loading rates. Three-axial compression tests were performed on the cortex tissues placed in a compression chamber. Shear tests were performed by punching a cylinder into a slice of the cortex. Tensile tests were carried out on the outer capsule. For characterization of the material behavior, a non-linear theoretical simulation based on a two parameter Blatz model was used. For characterization of the time-dependent behavior of the pig kidney cortex, a four-parameter linear viscoelastic model was employed. From the present experimental and theoretical studies, a number of conclusions were derived: (1) The general behavior of the pig kidney cortex samples under compression showed the general non-linear features typical of the soft tissues; the stress strain diagram was composed of a very flat part at very low stress level to about 30% relative deformation which was followed by a steeply rising stiffening leading to the radial rupture of samples marked by a maximum nominal rupture strain of about 50%. (2) The uniaxial compression tests on the radial and the tangential samples from the cortex tissue showed an increase of the rupture stress with the increase in the loading rate, but a decrease in the related rupture strain. (3) The long-term uniaxial compression tests on the cortex specimens under sustained constant load showed an instantaneous deformation followed by a creep response which eventually approached an asymptote. (4) Simulation of the non-linear material behavior of the cortex tissue under uniaxial compression by the Blatz model gave two pairs of material parameters for the cortex in the radial and the tangential directions. Furthermore, fitting of the assumed four-parameter linear viscoelastic model with the experimental data resulted in the viscoelastic material parameters.

Animals↗

A novel ex vivo model for investigation of fluid displacements in bone after endoprosthesis implantation.

Tissue perfusion and mass transport in the vicinity of implant surfaces prior to integration or bonding may play a crucial role in modulating cellular activities associated with bone remodeling, in particular, at early stages of the integration process. Furthermore, fluid displacements have been postulated to transduct mechanical stress signals to bone cells via loading-dependent flow of interstitial fluid through the lacunocanalicular network of bone. Thus, an understanding and new possibilities for influencing these processes may be of great importance for implant success. An ex vivo model was developed and validated for investigation of fluid displacements in bone after endoprosthesis implantation. This model serves to explicate the effects of surgical intervention as well as mechanical loading of the implant-bone construct on load-induced fluid flow in the vicinity of the implant. Using this model, we intend to quantify perfusion and extravascular flow dynamics in the vicinity of implants and define optimal conditions for enhancing molecular transport of osteotropic agents from the implant surface to apposing bone as well as from the blood supply to the implant surface. Furthermore, the elucidation of main transport pathways may help in understanding the distribution of wear particles in bone surrounding implant, a process which has been postulated to cause osteolysis and implant loosening.

Journal Article↗

High-definition true-colour television for use in minimally invasive medical procedures.

Endoscopes are key elements in the application of minimally invasive medical procedures. Thereby, image quality, ease of application and safety are of decisive importance for the user. This communication is primarily concerned with aspects relating to image quality. Standard television technology is presently used in endoscopes for image presentation purposes. It is however shown, that the inherent optical quality of most endoscopes exceeds the performance of standard TV. Accordingly, a special purpose advanced digital television system exhibiting true colour performance has been developed. Since endoscopic images usually are circular, its aspect ratio is quadratic with a spatial resolution of 1000 x 1000 pixels. It has furthermore a temporal resolution of 1 to 30 Hz noninterlaced and a contrast resolution of 56.6 dB. The design and performance of the system is documented.

Endoscopes↗

Biconcave contact lenses: a critical analysis of their optical properties.

BACKGROUND AND OBJECTIVE: The purpose of this experiment was to compare biconcave contact lenses with other contact lenses already used for observation and irradiation of the retina and choroid. MATERIALS AND METHODS: The optical performance of different biconcave lenses is described in terms of magnification, resolution, and field of view. The optical properties of the eye were taken into account using the Gullstrand's model of the human eye. RESULTS: The performance of biconcave contact lenses represents a compromise between that of Goldmann's and wide angle indirect contact lenses. An upright image, with good peripheral image quality and an intermediate field of view is characteristic of such design. In addition, laser irradiation with large spot sizes is less hazardous when using such negative contact lenses compared to positive lenses of the same absolute refractive power. CONCLUSIONS: Biconcave contact lenses qualify as a complement to planoconcave lenses for chorioretinal observation and irradiation tasks. For the same magnification factor, the field of view is smaller than that obtained with indirect contact lenses but the image degradation in the periphery of the retina is reduced.

Contact Lenses↗

Virtual reality based surgery simulation for endoscopic gynaecology.

Virtual reality (VR) based surgical simulator systems offer very elegant possibilities to both enrich and enhance traditional education in endoscopic surgery. However, while a wide range of VR simulator systems have been proposed and realized in the past few years, most of these systems are far from able to provide a reasonably realistic surgical environment. We explore the basic approaches to the current limits of realism and ultimately seek to extend these based on our description and analysis of the most important components of a VR-based endoscopic simulator. The feasibility of the proposed techniques is demonstrated on a first modular prototype system implementing the basic algorithms for VR-training in gynaecologic laparoscopy.

Computer Graphics↗

In vivo tracer transport through the lacunocanalicular system of rat bone in an environment devoid of mechanical loading.

Although diffusion has been shown to be the major contributing mechanism for molecular transport in the extravascular spaces of organs and soft tissues, it is unlikely that diffusion alone can account for molecular transport in the porous, yet relatively impermeable matrix of bone. Rather, it has been proposed that fluid flow induced by the deformations that bone is subjected to during daily activities may promote molecular transport through convective mixing of fluids or enhancement of molecular transport from the capillaries to the outermost osteocytes within a given osteon. As the relative contribution of diffusive and convective transport in the bone matrix has not yet been elucidated, we conducted experiments to study the primary role of diffusion for molecular transport within bone and to establish a baseline for fluid transport whereby mechanical loading effects are negligible. Procion red and microperoxidase were utilized as short-term (i.e., low MW, transported on the order of minutes) and long-term (i.e., comparatively high MW, transported on the order of hours) molecular tracers, respectively, to elucidate in vivo the pathways and extent of transport in the metacarpus and tibia of 60-day-old (i.e., skeletally immature) and 180-day-old (i.e., skeletally mature) animals. The tracers were introduced intravenously and the animals were maintained in an anesthetized state for the duration of the experiment to prevent physiological loading. In short-term studies, procion red tracer distribution was highly dependent on bone structure, demarcating spaces apposing the vascular pathways in the trabecular bone of immature animals and vascular and extravascular pathways (i.e., specifically, the lacunocanalicular system) within compact bone of mature animals. In longer term studies using microperoxidase, reaction product was concentrated in soft tissues as well as along a subperiosteal and subendosteal band of bone. In contrast, little peroxidase reaction product was observed in the metacarpal and tibial cortices of either immature or mature animals. Based on the results of these studies, diffusive transport mechanisms may suffice to insure an adequate supply of small molecules, such as amino acids, to osteocytes in the midcortex within minutes. In contrast, diffusion alone may not be efficient for transport of larger molecules. Thus, another mechanism of transport, such as convective transport by means of load-induced fluid flow, may be necessary to provide a sufficient supply of larger molecules, such as proteins to osteocytes for the maintenance of metabolic activity, as well as for activation or suppression of modeling processes.

Age Factors↗

The higher injury risk of abnormal kidneys in blunt renal trauma.

OBJECTIVE: To investigate the vulnerability of abnormal kidneys in blunt trauma, and to determine clinical features which enable identification of patients at risk of renal abnormality, hence modifying their management. MATERIAL AND METHODS: The medical records of 120 patients with blunt renal trauma were reviewed. Presence of pre-existing renal abnormalities, clinical symptoms, contrast study findings, associated injuries and the estimated impact velocity were recorded. RESULTS: Pre-existing renal abnormalities were found in 23 patients (19%). Patients with renal abnormalities had a lower rate of associated trauma to other abdominal organs, a lower Injury Severity Score (ISS) and their kidneys were more frequently injured by low velocity impacts. Of the patients with normal kidneys requiring surgery, hemodynamics and/or severity of the renal lesions triggered the operative indications in all cases, whereas most (57%) of the abnormal kidneys were operated because of their underlying renal pathology. CONCLUSION: Patients at risk for harbouring renal pathology are characterized by the association of monotrauma, macroscopic hematuria and low impact velocity. In this clinical setting, contrast studies should be generously indicated, since the management of abnormal kidneys unmasked by trauma is, to a large extent, dependent on the type of pathology.

Abdominal Injuries↗

Experimental elucidation of mechanical load-induced fluid flow and its potential role in bone metabolism and functional adaptation.

Several researchers have developed theories implicating some manifestation of mechanical forces such as stress, strain, and strain energy density for the initiation of cellular processes associated with functional adaptation. The mechanisms underlying dynamic bone growth and repair in response to mechanical stimuli, however, are not fully understood. Load-induced fluid flow has been postulated to provide a mechanism for the transmission of mechanical signals (eg, via shear stresses, enhancement of molecular transport, or electrical effects) and the subsequent elicitation of a functional adaptation response in bone. Although indirect evidence for such fluid flow phenomena can be found in the literature pertaining to strain-generated potentials, experimental studies are inherently difficult. This motivated the authors to develop theoretical as well as ex vivo, in vitro, and in vivo experimental methods for the study of transport processes and fluid flow within bone under well-controlled mechanical loading conditions. By introducing tracer substances such as disulphine blue, procion red, and microperoxidase into the experimental system, transport and fluid flow could be visualized at tissue, cellular, and subcellular levels, respectively. Based on these studies, it could be shown that load-induced fluid flow represents a powerful mechanism to enhance molecular transport within compact bone tissue. Furthermore, the distribution of transport-elucidating tracers is a function of mechanical loading parameters as well as the location within the cross-section of the bone cortex.

Adaptation, Physiological↗

Biomechanical analysis and clinical treatment of blunt renal trauma.

The treatment of renal trauma is evolving and increasingly focusing on the nonoperative and expectant management. In this review the ongoing controversy concerning the diagnosis and management of major blunt renal trauma shall be revisited. The contribution also includes a biomechanical approach for analyzing the renal injury mechanisms using a computer-simulated model of the kidney. In this connection, results of the modelling and simulations of the kidney subjected to the external forces shall be presented. Based on these findings a bending mechanism is postulated that may be responsible for renal injuries. Finally, the role of injury biomechanics research in the clinical management of trauma patients as well as in the area of injury prevention is discussed.

Abdominal Injuries↗

Continuous noninvasive measurement of cerebral arterial and venous oxygen saturation at the bedside in mechanically ventilated neonates.

OBJECTIVES: To test the practicablity of a new spectrophotometric method using pulse oximetric techniques in combination with special filters for the noninvasive determination of cerebral arterial and venous oxygen saturation and oxygen extraction in neonatal intensive care unit patients. The spectrophotometer used three different wavelengths at a sampling rate of 100 Hz. DESIGN: Clinical evaluation of a new method and comparison with previously published data. SETTING: Design and construction of the special spectrophotometer at the Biomedical Engineering Laboratory of the Swiss Federal Institute of Technology. Measurements in the neonatal intensive care unit of the University Hospital, Zurich, Switzerland. PATIENTS: Convenience sample of 15 clinically stable newborn infants, who were mechanically ventilated and receiving supplemental oxygen. Median gestational age was 29 5/7 wks (range 26 3/ 7 to 36 0/7), median birth weight was 1555 g (720 to 2500), median postnatal age was 4 days (1 to 10). INTERVENTIONS: The emitter and receiver were placed on the forehead near the sagittal sinus, between 2 and 2.8 cm apart, and the pulsating light attenuations (arterial and venous pulse waves) were recorded. MEASUREMENTS AND MAIN RESULTS: Arterial and venous pulse waves were satisfactory in 10 of 15 infants. Mean cerebral arterial oxygen saturation was 89.9 +/- 5.4% (SD), mean cerebral venous oxygen saturation was 73.0 +/- 8.9%, and mean cerebral oxygen extraction was 16.9 +/- 11.7%. A linear regression analysis demonstrated a significant correlation between mean PCO2 and venous oxygen saturation (slope 1.0%/torr, p < .05) and between mean PCO2 and cerebral oxygen extraction (slope -1.3%/torr, p < .05). CONCLUSION: This new method has the potential for monitoring continuously, noninvasively, and simultaneously cerebral arterial and venous oxygen saturation and oxygen extraction in mechanically ventilated preterm infants.

Blood Gas Analysis↗

The anisotropic structure of the human left and right ventricles.

An important determinant of cardiac output derives from the structure of the ventricular wall given by the arrangement of the cardiac muscle fibres. A key feature of this arrangement is both a global and local anisotropy. First, a preparation method necessary for analyzing the main aspects of spatial fibre architecture is outlined. Global anisotropy can be described by a gross band-like structure wrapping both left and right ventricles while local anisotropy results from the arrangement of the individual muscle fibres within the band. In pathologic cases this basic structure may be disturbed leading to cardiac failure. Second, a Finite Element model, formulated on the basis of Magnetic Resonance measurements has been devised which is intended to reflect the global as well as the local anisotropy of the ventricles in order to further the understanding of cardiac performance.

Animals↗

The heart's fibre alignment assessed by comparing two digitizing systems. Methodological investigation into the inclination angle towards wall thickness.

Myocardial contractile pathways which are not aligned strictly parallel to the heart's epicardial surface, give rise to forces which also act in the ventricular dilating direction. We developed a method which allows us to assess any fibre orientation in the three-dimensional myocardial weave. Decollagenized hearts were prepared by peeling-off fibre strands, following their main fibre orientation down to near the endocardium. In the subepicardium the strands followed a course more or less parallel to the epicardium, whereas from the mid-wall on they tended to dive progressively deeper into the wall. The preparation displays more or less rugged surfaces rather than smooth layers. The grooves and crests on the exposed surfaces were sequentially digitized by two methods: (1) Using a magnet tablet (3 Draw Digitizer System, Polhemus, Cochester VTO 5446, USA) on a dilated pig heart we manually followed the crests using a stylus, handling each groove and crest as an individual contractile pathway. (2) A constricted cow heart was digitized using a contact-free optical system (opto TOP, Dr. Breuckmann, Meersburg, Germany), which is based on the principle of imaging triangulation. Using specially developed software the inclination angles of selected crests and grooves with respect to the epicardial surface were calculated. The two digitizing methods yield comparable results. We found a depth- and side-specific weave component inclined to the epi-endocardial direction. This oblique netting component was more pronounced in the inner 1/3 of the wall than in the subepicardium. The inclination angle probably increases with increasing wall thickness during the ejection period. Manual digitizing is an easy and fast method which delivers consistent results comparable with those obtained by the cumbersome high resolution optical method. The rationales for the assessment of transmural fibre inclination are (1) the putative existence of dilating forces inherent in the myocardial weave and (2) the possible overproportional increase in the oblique transmural weave component during myocardial hypertrophy, which would entail a reduction in efficiency of ventricular performance in terms of haemodynamic work.

Animals↗

The assessment of intramural stress alignment on the beating heart in situ using micro-ergometry: functional implications.

The main local stress transmission pathways in the left ventricular base, midportion and apex in up to seven layers have been assessed in normal dog and porcine hearts, in hypertrophied dog hearts, and in three pig hearts having undergone a temporary left ventricular outflow stricture. The rotational sensitivity of needle force probes was used to determine the focal surface-parallel direction of the myocardial tension vector. In all places investigated the orientation of the force transmission pathways differs slightly from the morphologically determined fibre alignment. Vector rotation upon an axis normal to the epicardial surface is definitely tempered as compared to fibre rotation. Alterations in the force transmission pathways assessed in hypertrophied dog hearts by micro-ergometry qualitatively confirm structural remodelling in so far as an irregularity in the transmural rotation of the main stress vector was found. The measured disparities between the alignment of the myocardial fibre weave and the direction of stress transmission both in the normal and the diseased heart is widely individual, and hence, scattering of the data is marked. However, it must also be called into consideration that the measured orientation of force vectors is that at the moment of highest developed force, only. Further investigations will elucidate if discrepancies between that force vector and morphology are less pronounced when the vector is averaged over the entire heart cycle.

Animals↗

[The conservative treatment of major kidney injuries].

The choice of treatment (surgical or conservative) for major renal trauma still remains controversial. The objective of this study was to compare the results of patients with major renal trauma (grade III and IV) primarily treated by surgical intervention (1980-1992) with those in patients mainly treated conservatively (1992-1995). Between 1980 and 1995, 83 patients with major renal trauma were hospitalized at our institution. Our results show a higher nephrectomy rate of 44% in the case of primary surgical intervention compared to conservative management (27%). The outcome of twenty-two patients treated conservatively was analyzed prospectively with repeated radiological imaging, blood pressure profiles, and renal function assessment by means of MAG 3 renal scintigraphy. No patient developed renovascular hypertension and the relative function of the traumatized kidney was greater than 40% in 95% of patients. In conclusion, our results confirm a lower nephrectomy rate in the case of conservative management without any increase of the immediate or long-term morbidity. Major renal trauma (grade III, IV) can therefore be effectively treated by conservative management and primary surgical repair is only indicated in patients with hemodynamic instability, persistent hematuria and associated visceral injuries.

Adolescent↗

Automated finite element analysis of excised human femora based on precision -QCT.

The creation of 3-D finite element (FE) models of bone and implant-bone systems is a labor-intensive task due to the need to model different cases and variations, to perform patch tests and to account for the nonhomogeneous material properties with an acceptable amount of work. In this study, we developed an interface between a precision QCT and a FE system and applied it to a specimen bone. With the new method, the time necessary for model generation was reduced substantially. Furthermore, the elastic properties for each element were automatically derived from the corresponding CT-values. In order to demonstrate the importance of taking into account inhomogeneity, a comparison between the nonhomogeneous model and a homogeneous, "averaged" model was performed.

Biomechanical Phenomena↗

Improved monitoring of preterm infants by Fuzzy Logic.

Keeping the oxygenation status of newborn infants within physiologic limits is a crucial task in intensive care. For this purpose several vital parameters are supervised routinely by monitors, such as electrocardiograph, transcutaneous partial oxygen pressure monitor and pulse oximeter. Each monitor issues an alarm signal whenever an upper or lower limit of the parameter(s) measured is exceeded. However, in practice it turns out, that a considerable amount of false alarms is generated by artefacts, which are attributed mostly to movements of the infants. Eliminating these false alarms would be of benefit to the staff as well as the patients of the intensive care unit. Accordingly, an automated system based on Fuzzy Logic was developed, which is capable of distinguishing between critical situations and artefacts. The system is based on a Transputer IMS T425 in a PC, which collects the data from the monitors, plots it on a colour screen, saves it to hard disk and analyses it by Fuzzy Logic. Fuzzy algorithms were developed to generate more reliable alarms. All vital parameters of eight infants, who either moved often and/or frequently produced real alarm situations, were recorded. Synchronously the infants' movements and care procedures were video taped. The data and video were analysed off line with the help of an experienced neonatologist. His judgement was compared to the analysis of the Fuzzy Logic system. The results show that it is possible to improve the reliability of the monitored data with the aid of an evaluation strategy based on Fuzzy Logic and hence distinguish between real alarm situations and movement artefacts to the extent that an application in an intensive care unit under routine conditions becomes conceivable.

Algorithms↗

A new laser scalpel--a brief report.

One may consider the clad silica fibre cutting probe as a cheap alternative of the popular sapphire probe, sharing some of its properties. Made of silica, the scalpels have a fair heat tolerance and may be used without cooling by liquids or gas as is necessary with sapphire blades. The laser scalpel described here is driven (powered) with a 10 W cw Nd:YAG laser energy source (1064 nm) and possesses good cutting and haemostatic properties. It may also be used with lasers emitting other wavelengths. One may assume that a diode laser emitting in the near infrared (800-810 nm) may have very similar, although no analogous cutting properties when used with the described scalpel.

Equipment Design↗