PubMed Health⌕ Search

Biomedical subjects

P Niedermann

Publications and source records attributed to P Niedermann.

5 recordsLinked to original sources

Modular approach to fabrication of three-dimensional microchannel systems in PDMS-application to sheath flow microchips.

A modular approach to fabrication of three-dimensional microchannel systems in polydimethylsiloxane (PDMS) is presented. It is based on building blocks with microstructuring on up to three faces. The assembled 3D-microchip consists of three building blocks in two layers. For assembly of the bottom layer two building blocks are joined horizontally, whereby the side structuring of the first is sealed against the flat side surface of the other. This results in the formation of a vertical interconnection opening between the building blocks to supplement the microstructuring on the lower faces. The 3D microchannel system is completed by placing a third building block, with microstructuring only on its lower face, on top of the assembled layer. While plasma assisted bonding is used between the two building blocks of the bottom layer, inherent adhesion is sufficient between the layers and for attaching the assembled 3D-microchip to a substrate. This modular approach was applied to the fabrication of a 3D-sheath flow microchip. It comprises a 20 microm deep microchannel system with sample inlet, open sensing area and outlet in the bottom layer and sheath flow inlet in the top layer. 100 microM fluorescein at 6 microL min(-1) was used as sample flow and water at increasing flow rates as sheath flow. With ratios of sheath to sample flow up to 20:1 sample layers down to 1 microm thickness could be generated. Sample layer thickness was determined via volume detection on an epi-fluorescence microscope followed by image analysis.

Journal Article↗

A small scanning tunnelling microscope with large scan range for biological studies.

We have developed a scanning tunnelling microscope specially designed for biological application presenting some new features: the scanner tube is mounted parallel to the surface of the sample which enables a high resolution optical microscope to be brought close to the sample when working in air or liquids. The maximum scan range is 5x20 microm with a vertical range of 20 microm and the total size of the system does not exceed 10x40 mm. The piezo-sensitivity of the scanner tube versus applied voltage was analysed by interferometry measurements and by using scanning tunnelling microscopes. We found a value for the piezoelectric constant d13 of -1.71 A/V at low voltages (under a few volts) going up to -2 A/V for higher voltages. Large-scale images of a carbon grid showed a surprisingly good linearity of the scanner tube.

Microscopy, Electron, Scanning↗