PubMed Health⌕ Search

Biomedical subjects

P Onnerfjord

Publications and source records attributed to P Onnerfjord.

10 recordsLinked to original sources

Binding mitochondria to cryogel monoliths allows detection of proteins specifically released following permeability transition.

Following proapoptotic signals such as calcium-induced mitochondrial permeability transition or translocation of proapoptotic proteins, mitochondria induce cell death through release of apoptogenic proteins. The mechanism of release and the identity of the released proteins are currently debated. Earlier attempts at identification of the apoptogenic proteins have been hampered by a high nonspecific background. Our aim was to develop a novel method where background release was eliminated, allowing proteins specifically released from mitochondria following proapoptotic stimulation to be identified. Liver mitochondria were immobilized and washed on cryogel monoliths prior to induction of protein release (calcium or Bid/Bax). Immobilized mitochondria exhibited normal morphology and swelling response and retained respiratory activity. The released proteins were collected, concentrated, separated on polyacrylamide gels which were cut into pieces, trypsin-digested, and analyzed using liquid chromatography-tandem mass spectrometry. Control samples contained no protein, and stimulation with calcium and Bid/Bax resulted in identification of 68 and 82 proteins, respectively. We conclude that, in combination with the robust proteomic approach, immobilization on cryogel monoliths is a fruitful approach for studying specific protein release from isolated mitochondria. We propose that this method is a powerful tool to further characterize the role of mitochondria in cell death induction.

Animals↗

Signal amplification using "spot-on-a-chip" technology for the identification of proteins via MALDI-TOF MS.

The presented "spot-on-a-chip" technology enables easy enrichment of samples in the low nanomolar (1-5 nM) range and provides a fast and reliable automated sample preparation method for performing matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) analysis with high sensitivity and throughput. Through microdispensing, which allows accurate deposition of 60-pL droplets, dilute samples were enriched by making multiple droplet depositions in nanovials. The sample was confined to a defined spot area (300 x 300 microm), and multiple depositions increase the surface density of analyte in the nanovial, thereby providing detection of low attomole levels. The impact of the nanovial geometry with respect to the MALDI-TOF MS resolution for peptides deposited in the microfabricated silicon vials was investigated and the optimal geometry and size were determined. The spot-on-a-chip technology, that is, the combination of microdispensing, micromachined silicon nanovials and on-spot enrichment provides a signal amplification of at least 10-50 times as compared to an ordinary sample preparation. The linearity of the enrichment effect is shown by the analysis of a peptide mixture at the 5 nM level. The signal amplification provided by the spot-on-a-chip enrichment is demonstrated by the analysis of relevant biological samples, interleukin-8 from a spiked cell supernatant, and by successful protein identification of an excised spot from a high-sensitivity silver-stained two-dimensional electrophoresis gel separation.

Adrenocorticotropic Hormone↗

Identification and characterization of asporin. a novel member of the leucine-rich repeat protein family closely related to decorin and biglycan.

Asporin, a novel member of the leucine-rich repeat family of proteins, was partially purified from human articular cartilage and meniscus. Cloning of human and mouse asporin cDNAs revealed that the protein is closely related to decorin and biglycan. It contains a putative propeptide, 4 amino-terminal cysteines, 10 leucine-rich repeats, and 2 C-terminal cysteines. In contrast to decorin and biglycan, asporin is not a proteoglycan. Instead, asporin contains a unique stretch of aspartic acid residues in its amino-terminal region. A polymorphism was identified in that the number of consecutive aspartate residues varied from 11 to 15. The 8 exons of the human asporin gene span 26 kilobases on chromosome 9q31.1-32, and the putative promoter region lacks TATA consensus sequences. The asporin mRNA is expressed in a variety of human tissues with higher levels in osteoarthritic articular cartilage, aorta, uterus, heart, and liver. The deduced amino acid sequence of asporin was confirmed by mass spectrometry of the isolated protein resulting in 84% sequence coverage. The protein contains an N-glycosylation site at Asn(281) with a heterogeneous oligosaccharide structure and a potential O-glycosylation site at Ser(54). The name asporin reflects the aspartate-rich amino terminus and the overall similarity to decorin.

Adult↗

Protein identification platform utilizing micro dispensing technology interfaced to matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

An integrated protein microcharacterization/identification platform has been developed. The system has been designed to allow a high flexibility in order to tackle challenging analytical problems. The platform comprises a cooled microautosampler, an integrated system for microcolumn HPLC, and a capillary reversed-phase column that is interfaced to matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) system via a low internal volume flow-through microdispenser. The chromatographic separation is continuously transferred onto a MALDI target plate as discrete spots as the dispenser ejects bursts of droplets of the column effluent in a precise array pattern. A refrigerated microfraction collector was coupled to the outlet of the flow-through microdispenser enabling enrichment and re-analysis of interesting fractions. The use of target plates pre-coated with matrix simplified and increased the robustness of the system. By including a separation step prior to the MALDI-TOF-MS analysis and hereby minimizing suppression effects allowed us to obtain higher sequence coverage of proteins compared to conventional MALDI sample preparation methodology. Additionally, synthetic peptides corresponding to autophosphorylated forms of the tryptic fragment 485-496 (ALGADDSYYTAR) of tyrosine kinase ZAP-70 were identified at sensitivities reaching 150 amol.

Amino Acid Sequence↗

Integrated microanalytical technology enabling rapid and automated protein identification.

Protein identification through peptide mass mapping by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has become a standard technique, used in many laboratories around the world. The traditional methodology often includes long incubations (6-24 h) and extensive manual steps. In an effort to address this, an integrated microanalytical platform has been developed for automated identification of proteins. The silicon micromachined analytical tools, i.e., the microchip immobilized enzyme reactor (mu-chip IMER), the piezoelectric microdispenser, and the high-density nanovial target plates, are the cornerstones in the system. The mu-chip IMER provides on-line enzymatic digestion of protein samples (1 microL) within 1-3 min, and the microdispenser enables subsequent on-line picoliter sample preparation in a high-density format. Interfaced to automated MALDI-TOF MS, these tools compose a highly efficient platform that can analyze 100 protein samples in 3.5 h. Kinetic studies on the microreactors are reported as well as the operation of this microanalytical platform for protein identification, wherein lysozyme, myoglobin, ribonuclease A, and cytochrome c have been identified with a high sequence coverage (50-100%).

Autoanalysis↗

Homogeneous sample preparation for automated high throughput analysis with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry.

This work presents a simple method for obtaining homogeneous sample surfaces in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the automated analysis of peptides and proteins. The sample preparation method is based on applying the sample/matrix mixture onto a pre-deposited highly diluted matrix spot. The pre-deposited crystals act as seeds for the new sample containing crystals which become much smaller in size and more evenly distributed than with conventional methods. This 'seed-layer' method was developed, optimised and compared with the dried-droplet method using peptides and proteins in the 1000-20,000 Da range. The seed-layer method increases the surface homogeneity, spot to spot reproducibility and sample washability as compared with the commonly used dried-droplet method. This methodology is applicable to alpha-cyanohydroxycinnamic acid, sinapinic acid and ferulic acid, which all form homogeneous crystal surfaces. Within-spot variation and between-spot variation was investigated using statistics at a 95% confidence level (n = 36). The statistical values were generated from more than 5000 data points collected from 500 spectra. More than 90% of the sample locations results in high intensity spectra with relatively low standard deviations (RSDs). Typically obtained data showed an RSD of 19-35% within a sample spot as well as in-between spots for proteins, and an RSD of < or = 50% for peptides. Linear calibration curves were obtained within one order of magnitude using internal calibration with a point-RSD of 3% (n = 10). The sample homogeneity allows mass spectra (average of 16 laser shots) to be obtained on each individual sample within 15 sec, whereby a 100 spot target plate can be run in 25 min. High density target plates using the seed-layer method were prepared by spotting approximately 100 picoliter droplets onto the target, resulting in sample spots < or = 500 microns in diameter using a flow-through piezo-electric micro-dispenser. By using this automated sample preparation step lower standard deviations are obtained in comparison to manually prepared samples.

Coumaric Acids↗

Picoliter sample preparation in MALDI-TOF MS using a micromachined silicon flow-through dispenser.

This paper presents a picoliter sample preparation technique utilizing the flow-through principle, allowing on-line coupling of chromatographic systems to be made. The work was performed in order to investigate the characteristics and the physicochemical properties of the sample preparation using typical mobile phase conditions from mu-CLC (column liquid chromatography) separations. The device presented here is a pressure pulse-driven dispenser, formed by two silicon structures processed by conventional micromachining. The pressure pulse is generated in the flow-through channel by a piezoceramic element. Depending on the orifice size, the droplets ejected range between 30 and 200 pL. The maximum ejection frequency is 500 Hz, limited by resonances within the unit. A pyramid-shaped nozzle improves the directivity of the droplets since it reduces the wetting of the orifice front surface area. The risk of particles sticking close to the orifice is also minimized. The analyses of the deposited sample spots were carried out on a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer with delayed extraction. It was possible to detect attomole amounts (159-248 amol) of various proteins (cytochrome c, ribonuclease A, lysozyme, and myoglobin) from a single droplet of matrix:analyte 1:1 (drop volume approximately 110 pL). Additionally, it was found that sample enrichment could be carried out using multiple depositions on the same spot; i.e., 31 nM of insulin was easily detected when more than four depositions were made on the same spot, while no detection was possible without sample enrichment. Size optimization of the MALDI sample spot gave target zones of 100-500-micron diameter that matched the size of the laser focal point and resulted in a considerably increased sample throughput.

Cell Line↗

Fluorescence polarisation for immunoreagent characterisation.

Antibodies were characterised using fluorescence polarisation, a homogeneous assay technique in which all reagents are in solution. Kinetic studies on the association and dissociation of the immunocomplex were performed. A competitive assay was used and the sensitivities, operational linearities, as well as the specificities of the immunoassays were experimentally determined for various antibody preparations with specificity for triazines. Detection limits for atrazine in water samples were determined to be within the range of 0.08-0.4 ng ml(-1) using a 5-min incubation time and a 0.5-ml sample volume.

Animals↗

High sample throughput flow immunoassay utilising restricted access columns for the separation of bound and free label.

A flow immunodetection system with high sample throughput capacity is described for the screening of various analytes. The immunochemical detection principle is based on the chromatographic separation of the formed immunocomplex (AbAg or AbAg*) and the free antigen (Ag) by a restricted access (RA) column, utilising size-exclusion and reversed-phase mechanism. A fluorescein labelled analyte (Ag*) was used in the competitive assay format with fluorescence detection. The speed and simplicity of the assay were the greatest advantages, allowing measurement of the analyte to be carried out in less than 1 min. The biocompatibility and capacity of the restricted access material allowed multiple injections of up to 5000, without any breakthrough of the fluorescent tracer molecule and thus need for regeneration. The flow immunoassay was developed using the well-known atrazine herbicide and some transformation products as model compounds, due to their human toxicity and widespread use. The sample throughput was 80 samples per hour and the detection limits were 1.4 nM (300 pg/ml) for atrazine (Ab I) and 2.3 nM (500 pg/ml) for the sum of triazines (Ab II-III). Different sample matrices, PBS buffer, creek water, and urine were successfully applied in the flow system without the need for any sample handling step. For plasma samples an additional clean-up step using solid-phase extraction had to be included. The resulting detection limits for atrazine in plasma and water samples using this clean-up and trace enrichment procedure were found to be 2 ng/ml and 20 pg/ml, respectively. The analysis could be performed at a sample throughput rate of 400 per 6-h working shift.

Atrazine↗

A flow immunoassay for studies of human exposure and toxicity in biological samples.

This paper describes a heterogeneous competitive flow immunoassay with a high sample throughput which can be used for the screening of smaller analytes in various samples. The method is based on off-line incubation of the analyte (Ag), a fluorescent labelled tracer (Ag*) and the corresponding antibody (Ab). The separation of bound (Ab-Ag*) and free tracer (Ag*) is based on a size exclusion and reversed phase mechanism utilizing a restricted access (RA) column. The column traps the free unbound tracer (Ag*) in its hydrophobic (C18) inner cavity but excludes the large Ab-Ag* complex, which is passed on and measured by the fluorescence detector. The flow immunoassay was developed using the triazine herbicide atrazine as a model compound owing to its human toxicity and widespread use. A sample throughput of 80 samples per hour and a detection limit of 300 pg ml-1 in water were obtained. Urine samples were successfully applied for direct injections into the flow system, while for human plasma samples an additional clean-up step using solid phase extraction was efficiently included where pure extract is obtained with the highly stable and biocompatible extracting column material. The resulting detection limits for atrazine in plasma and water samples using this clean-up and trace enrichment procedure were found to be 2 ng ml-1 and 20 pg ml-1 respectively.

Animals↗