PubMed Health⌕ Search

Biomedical subjects

P Pedroso

Publications and source records attributed to P Pedroso.

9 recordsLinked to original sources

Assessment of a new test to detect Legionella urinary antigen for the diagnosis of Legionnaires' Disease.

Given that the rate of mortality by Legionella pneumonia increases in incorrectly treated patients, rapid diagnosis and early antibiotic treatment are needed. We have assessed the performance of a new enzyme immunoassay (EIA) test (Bartels Inc. Trinity Biotech Company, Wicklow, Ireland) to detect Legionella pneumophila antigen in urine comparing it to Binax EIA (Binax, Portland, Maine). We also evaluated the capability of both EIAs to detect extracted soluble antigens of Legionella strains. Using nonconcentrated urine samples (NCU) the sensitivity of Bartels EIA was 74.1% (66/89) and the sensitivity of Binax EIA was 51.7% (46/89). The sensitivity of both EIA tests were 91.5% (54/59) using concentrated urine samples (CU). Specificity of both EIA tests was 100% in NCU and CU. Bartels EIA was able to detect all serogroup L. pneumophila antigens, achieving a higher sensitivity in the case of L. pneumophila serogroup 1 soluble antigen. The new EIA was found to be a useful test for the rapid diagnosis of Legionella pneumonia, being a better alternative to the Binax EIA if NCU is used.

Antigens, Bacterial↗

Detection of Streptococcus pneumoniae antigen by a rapid immunochromatographic assay in urine samples.

STUDY OBJECTIVES: Evaluation of a newly available rapid (15 min) immunochromatographic membrane test (ICT) to detect Streptococcus pneumoniae in urine samples, in order to assess its utility in the diagnosis of bacteremic and nonbacteremic pneumococcal pneumonia. DESIGN: Retrospective study. SETTING: We studied urine samples from 51 patients with bacteremic and nonbacteremic pneumonia due to S pneumoniae diagnosed by blood culture and pneumococcal polysaccharide capsular antigen detection by counterimmunoelectrophoresis in urine samples, 16 patients with probable pneumococcal pneumonia, 71 patients with nonpneumococcal pneumonia, and 16 patients with pneumonia but no pathogen identified. Urine samples were collected and frozen at - 20 degrees C until used. The ICT test was performed following the instructions of the manufacturer. MEASUREMENTS AND RESULTS: S. pneumoniae antigen was detected in 41 of 51 patients with pneumococcal pneumonia (80.4%); results were positive in 23 of 28 bacteremic cases (82.1%) and in 18 of 23 nonbacteremic cases (78.3%). From patients with a diagnosis of presumptive pneumococcal pneumonia, antigen was detected in seven urine samples (43.7%) and also in one case of the 16 patients with pneumonia but no pathogen identified. The specificity of the ICT test was 97.2%. CONCLUSION: The ICT assay is a valuable tool for the diagnosis of pneumococcal pneumonia, especially for the nonbacteremic cases.

Adolescent↗

Longitudinal analysis of fibroblast growth factor expression after transplantation and association with severity of cardiac allograft vasculopathy.

BACKGROUND: Vascular smooth muscle cell growth factors are postulated to contribute to cardiac allograft vasculopathy (CAV). Few data quantitatively address the timing, location, or stimuli for growth factor expression and relationship to CAV. METHODS AND RESULTS: Acidic fibroblast growth factor (aFGF) mRNA expression was determined in serial endomyocardial biopsies during the first year after transplantation. Patients with high levels of aFGF mRNA and elevations after the early posttransplant period had significantly more severe CAV than patients with low aFGF and no late elevations. CONCLUSIONS: Parenchymal aFGF expression varies between patients and in the same patient over time and correlates with development of CAV.

Biopsy↗

Evaluation of a rapid immunochromatographic assay for the detection of Legionella antigen in urine samples.

A new immunochromatographic membrane assay for detecting Legionella pneumophila serogroup 1 antigen in urine samples (Binax Now Legionella Urinary Antigen Test; Binax, USA) was evaluated. Its sensitivity, specificity and level of agreement with the Binax enzyme immunoassay were compared using nonconcentrated and concentrated urine samples. The overall agreement between the two tests was 98.1%; the specificity of both was 100%. The sensitivity of the immunochromatographic assay was 55.5% in nonconcentrated urine and 97.2% in concentrated urine in comparison with the enzyme immunoassay, using concentrated urine as the reference test. This immunochromatographic assay screens successfully for Legionella pneumophila serogroup 1 soluble antigen in concentrated urine samples.

Adult↗

Comparison of the Binax Legionella urinary antigen enzyme immunoassay (EIA) with the Biotest Legionella Urin antigen EIA for detection of Legionella antigen in both concentrated and nonconcentrated urine samples.

We evaluated a newly commercial enzyme immunoassay (EIA) (Biotest Legionella Urin Antigen EIA; Biotest AG, Dreieich, Germany) for detection of antigens of all Legionella pneumophila serogroups with a relatively wide spectrum of cross-reactivity as well as antigens of other Legionella spp. by comparing its sensitivity and specificity with those of an EIA for detection of L. pneumophila serogroup 1 antigen (Legionella urinary antigen EIA; Binax, Portland, Maine). Both tests were performed with both concentrated and nonconcentrated urine samples. We also evaluated the capabilities of both EIAs to detect extracted soluble antigens of American Type Culture Collection (ATCC) Legionella strains (L. pneumophila serogroups 1 to 14, L. bozemanii, and L. longbeachae). The sensitivity of the Biotest EIA was 66.66% in nonconcentrated urine and 86.66% in concentrated urine. The sensitivity of the Binax EIA was 63.76% and 88.88% in nonconcentrated and concentrated urine, respectively. The specificity was 100% in nonconcentrated and concentrated urine for both assays. The Binax EIA and Biotest EIA detected extracted soluble antigens of L. pneumophila serogroups 1 to 14 and L. bozemanii ATCC strains. The cross-reactions observed with the Binax EIA were probably due to common epitopes directly related to lipopolysaccharide. Further studies are required to determine the usefulness of the Binax EIA for detection of urinary antigens from Legionella species and serogroups other than L. pneumophila serogroup 1. The Biotest EIA proved to be as rapid, sensitive, and specific as the Binax EIA for the diagnosis of legionellosis. Concentration of antigen present in urine increased the sensitivities of both techniques with no reduction in specificity.

Adult↗

Gram-scale purification of phosphorothioate oligonucleotides using ion-exchange displacement chromatography.

The purification of oligonucleotides by ion-exchange displacement chromatography is demonstrated on the gram-scale. Using a 50 mmD x 100 mmL (203 ml) column operated in the displacement mode, 1.2 g of a 24mer phosphorothioate oligonucleotide was purified. Product yield for this separation was 70% (780 mg) at a purity of 96.4% and the mass balance recovery of all oligonucleotide was 97.5%. The displacement purification of four additional phosphorothioate oligonucleotides ranging in length from 18 to 25 bases is also demonstrated on the semi-preparative (10-50 mg) scale. All of these oligonucleotides were purified using similar displacement conditions and typical results were 60% yield at 96% purity. The displacement portion of these separations required <15 min and total cycle time including equilibration, feed loading and regeneration can be performed in under 30 min. These results seem to indicate that displacement chromatography may be amenable to generalizations in separation protocol that would greatly reduce the effort required to obtain an optimized purification scheme for moderately long oligonucleotides.

Chromatography, High Pressure Liquid↗

Rapid screening with indirect immunotoxin for monoclonal antibodies against human small cell lung cancer.

For the first time, a screening procedure for antitumor monoclonal antibodies (MOABs) has been developed in which the ability of MOABs to mediate the indirect action of another immunotoxin is the primary criterion for selection of hybridomas for expansion and cloning. Use of the indirect immunotoxin makes it possible to screen MOABs for cytotoxic potential without the necessity of covalently coupling toxin to each individual MOAB. Hybridomas derived from spleens of immunized mice were screened for the synthesis of monoclonal antibodies able to participate in the delivery of a pharmacologically active, indirect immunotoxin conjugate to H69 lung cancer cells. The indirect immunotoxin conjugate was goat anti-mouse immunoglobulin disulfide linked to pokeweed antiviral protein. There was no correlation between the results of the screening with the indirect immunotoxin and an enzyme-linked immunosorbent assay screen for binding of MOAB to tumor cell membranes. An indirect immunotoxin prepared from Fab' fragments of goat anti-mouse immunoglobulin was also effective as an indirect immunotoxin conjugate. Each screening of more than 300 hybridomas was performed in 3 days. The indirect immunotoxin screen detected antitumor MOABs which were not detected by the conventional enzyme-linked immunosorbent assay method. A MOAB selected by the indirect immunotoxin screen was conjugated to pokeweed antiviral protein; the conjugate mediated immunocytotoxicity in a standard direct toxicity assay.

Animals↗