Toolkit for lung sound analysis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to P Piirilä.
Explore the source record for details and available documents.
Cough is a primitive reflex typically consisting of an initiating deep inspiration, glottal closure, and an explosive expiration accompanied by a sound. The flow characteristics of cough have been shown to differ between different pulmonary diseases. Cough sounds are generated at the larynx and in the lungs. Modern analysing techniques have also been applied in cough sound studies, and differences in cough sound duration and spectra have been found in pulmonary diseases with different bronchopulmonary pathophysiology. Since the objective assessment of cough is clinically important, automatic cough detectors and counters have been constructed, e.g. to assess the efficacy of antitussive drugs. Also, ambulatory methods for assessment of cough have been reported. This review includes a brief history of cough research and present methods available for objective assessment of cough.
Crackles are short interrupted breath sounds usually associated with pulmonary disorders. According to present opinion, a crackle is generated when an abnormally closed airway opens during inspiration or closes at the end of expiration. The timing of crackles in breathing cycles can be assessed with phonopneumography, their duration with time-expanded waveform analysis, and their pitch with analysis of frequency spectra. The timing, pitch and waveform of crackles are different in pulmonary disorders reflecting different pulmonary pathophysiology. This review deals with the genesis, auscultation, recording and analysis of crackles, with an emphasis on modern signal-processing methods.
Occupational respiratory symptoms caused by decorative flowers are seldom reported in the literature. In the years 1985-1993 four such cases of occupational asthma were diagnosed at the Institute of Occupational Health of Finland. Occupational asthma was caused by freesias (n = 1), chrysanthemums (n = 1), and tulips (n = 2). The diagnoses were based on work-related respiratory symptoms during flower handling in the patients' histories, specific challenge tests, and allergologic examinations. Flower allergy is rare but can even develop into occupational asthma. It usually leads to a change of profession.
Air-flow standardized breath sounds were recorded at the chest and at the trachea during histamine challenge test and after subsequent bronchodilation in 12 asthmatics and 6 healthy controls for spectral analysis, to be compared with simultaneous changes in spirometric variables. Of all the lung sound variables measured, the changes in median frequency of the power spectrum (F50) of tracheal expiratory sounds were found to correlate best (r = 0.853, p < 0.0001) with changes in FEV1. The increase of F50 during histamine challenge was significantly larger in asthmatics than in healthy control subjects (p < 0.005). The provocative dose of histamine inducing a decrease of 15 percent in FEV1 (PD15FEV1) and the provocative dose causing an increase of 30 percent in tracheal expiratory F50 (PD30F50) were significantly related (r = 0.754, p = 0.012). In asthmatics, the breath sound frequency distribution in terms of median frequency reflected acute changes in airways obstruction with high sensitivity and specificity. The present method for breath sound analysis can be applied for patients with limited cooperation during bronchial challenge tests.
Recorded crackling lung sounds of 11 patients with pneumonia were studied with phonopneumography, FFT spectrography and time-expanded waveform display. The sounds were recorded on average six days after the onset of pneumonia and the recording was repeated two to four days later. In the first recording the crackles were coarse and midinspiratory. The patients with unilateral pneumonia had a significant difference in the upper frequency limit of inspiratory sound of the FFT spectrum between the healthy and diseased lung (p less than 0.01). In the second recording, the beginning of crackling had shifted later (p less than 0.01) and the end point of crackling also became later (p less than 0.05). The largest deflection width of the individual crackles became shorter (p less than 0.05). The results indicate that the pneumonic crackles vary markedly during the clinical course of pneumonia. The duration of the individual crackles became shorter and the timing of the crackles shifted toward the end of inspiration.
Crackling lung sounds are associated with many pulmonary diseases. Their occurrence reflects the quality and the severity of the disease. An automatic method for crackle detection is developed, based on analysing the spectral stationarity of the lung sound. The method is validated by studying the crackles of 20 adult patients; 10 with fibrosing alveolitis (FA) and 10 with bronchiectasis (BE). The number of crackles detected by the automatic method in inspiratory cycles is compared to the number of crackles counted from time-expanded waveforms by two expert observers. The total number of inspiratory cycles studied is 117 and that of crackles 1064. The method has a sensitivity of 89 per cent and a positive predictivity of 88 per cent for patients with FA, and 80 per cent and 83 per cent respectively, for patients with BE. The linear correlation coefficients between the numbers of crackles counted by the automatic method and by the observers is 0.86 (p less than 0.001) for the patients with FA and 0.93 (p less than 0.001) for the patients with BE. The values refer to whole inspiratory cycles. The new automatic method seems reliable enough for clinical and scientific purposes. It enables a rapid and objective analysis of large materials with crackling lung sounds.
In lung sound research, low-frequency noise usually disturbs the sound signal being recorded. Some researchers therefore use high-pass filtration before the final analysis. In this study, the effect of digital and analog high-pass filtration on the morphology of the lung sound crackles is evaluated. The original nonprefiltered crackle waveform is presented, and the effect of the high-pass filtration on the crackle waveform characteristics is elucidated in one patient with silicoasbestosis.
We have studied the crackling lung sounds of ten patients with cryptogenic fibrosing alveolitis, ten with bronchiectasis, ten with chronic obstructive pulmonary disease, and ten with heart failure by analyzing frequency, waveform, and timing of crackles. The upper frequency limit of inspiratory sounds was higher in CFA than in COPD or in HF. The period of crackling was shorter in COPD than in CFA or BE. Inspiratory crackling terminated significantly earlier in COPD than in CFA, BE, or HF. The initial deflection width and the two-cycle duration of the expanded waveforms of crackles were smaller in CFA than in BE, COPD, or HF. The largest deflection width was smaller in CFA than in BE, HF, or COPD and smaller in BE than in HF. The results indicate that crackling lung sounds in different diseases have distinctive features and that their analysis can be of diagnostic value.
Eleven patients on haemodialysis were treated with erythropoietin (EPO), 50-200 U kg-1 once to three times a week, for up to 1 year. After outset of EPO all patients became transfusion-independent. Four patients did not reach the target haemoglobin (Hb) level 100 g l-1 in 5 months. These patients had higher serum concentrations of aluminium (225 +/- 87 micrograms l-1, mean +/- SD) than the responding patients (55 +/- 56 micrograms l-1). Addition of desferrioxamine to treatment with EPO resulted in a rapid rise in Hb values in these patients. Thus, aluminium may inhibit EPO responsiveness. All patients were iron overloaded. Serum ferritin levels declined in all but one patient with secondary haemochromatosis. In exercise tests the aerobic capacity and oxygen uptake increased during EPO therapy. Peak oxygen consumption (Vo2 peak), oxygen pulse, oxygen uptake at anaerobic threshold (AT) and total work output (W max) increased 19%, 36%, 26% and 24%, respectively. Lean body mass (LBM) increased by 8%. Taken together, all clinical EPO effects measured appeared clinically favourable.
The aim of this study was to determine whether the flow dynamics and sound spectra of spontaneous cough show characteristic differences in asthma, acute and chronic bronchitis, TBCS and FPD. During the cough, the air flow from the mouth and the sound from the sternal manubrium were simultaneously recorded. The cough sounds were analyzed spectrographically. Peak expiratory flow during cough was significantly lower in asthma than in TBCS, acute bronchitis or FPD. Duration of the first cough sound was longer in asthma than in FPD, TBCS or chronic bronchitis. The number of additional cough sounds was smaller in asthma than in the other conditions. The highest frequency components of cough sound were lower in asthma than in chronic bronchitis or TBCS. The results indicate that pulmonary diseases differ with respect to acoustic and dynamic characteristics of spontaneous cough. This finding may prove useful in the diagnosis of cough.
Explore the source record for details and available documents.
A study was designed to investigate whether asthma, when carefully managed, is associated with an increased risk of complications in connection with pregnancy. One hundred and eighty one asthmatic women were monitored during 198 pregnancies. Antiasthmatic treatment consisted of inhaled beta 2 adrenergic drugs, beclomethasone, sodium cromoglycate, oral theophylline, and systemic corticosteroids as needed. Postpartum information on asthmatic symptoms and infant feeding was collected by means of a questionnaire. A control group of 198 non-asthmatic pregnant women was matched for age and parity. Atopic women had less severe asthma than non-atopic women. During pregnancy 40% of the patients were managed with the same antiasthmatic medication as before pregnancy; 18% needed less and 42% more medication. Pre-eclampsia occurred more often in asthmatic than control subjects, especially in patients with severe asthma. Hypoglycaemia occurred more often in infants of mothers with severe asthma than in infants of mothers with less severe disease. Theophylline medication at term did not influence labour or delivery. Asthma caused no emergencies during labour. Among the asthmatic subjects 28% of babies were delivered by caesarean section compared with 17% in the control group. There was no difference between asthmatic and control subjects with regard to length of gestation, birth weight, incidence of perinatal deaths, low Apgar scores, neonatal respiratory difficulties, hyperbilirubinaemia, or malformations. It is concluded that severe asthma or systemic corticosteroid treatment (or both) during pregnancy seems to increase the incidence of mild pre-eclampsia in the mother and hypoglycaemia in the infant. The findings suggest that careful supervision of asthma during pregnancy and labour by obstetricians and chest physicians working in close collaboration should prevent most of the serious obstetric and neonatal complications of asthma in pregnancy reported by previous authors.
Reliable long-term assessment of cough is necessary in many clinical and scientific settings. A new method for long-term recording and automatic analysis of cough is presented. The method is based on simultaneous recording of two independent signals: high-pass filtered cough sounds and cough-induced fast movements of the body. The acoustic signals are recorded with a dynamic microphone in the acoustic focus of a glass fiber paraboloid mirror. Body movements are recorded with a static charge-sensitive bed located under an ordinary plastic foam mattress. The patient can be studied lying or sitting with no transducers or electrodes attached. A microcomputer is used for sampling of signals, detection of cough, statistical analyses, and on-line printing of results. The method was validated in seven adult patients with a total of 809 spontaneous cough events, using clinical observation as a reference. The sensitivity of the method to detect cough was 99.0 percent, and the positive predictivity was 98.1 percent. The system ignored speaking and snoring. The method provides a convenient means of reliable long-term follow-up of cough in clinical work and research.
Explore the source record for details and available documents.