PubMed Health⌕ Search

Biomedical subjects

P Popp

Publications and source records attributed to P Popp.

At least 19 recordsLinked to original sources

Membrane-assisted liquid-liquid extraction coupled with gas chromatography-mass spectrometry for determination of selected polycyclic musk compounds and drugs in water samples.

Selected polycyclic musk compounds and drugs were extracted from water samples by membrane-assisted micro liquid-liquid extraction. The two-phase extraction system consisted of polyethylene membrane bags filled with an organic solvent. Chloroform proved to be most suited as acceptor phase to extract caffeine, Galaxolide, Tonalide, phenazone and carbamazepine from aqueous samples. The compounds were enriched from 50 mL sample into a volume of 500 microL of chloroform. Gas chromatography-mass spectrometry (GC-MS) was applied for analysis. The extraction procedure was optimised in regard to membrane material, extraction time and temperature. The evaluation of the entire analysis protocol found limits of detection that ranged from 20 to 200 ng/L. The linear range of calibration covered one magnitude with standard deviations between 4 and 12%. Method comparison with standard analysis techniques such as solid-phase extraction (SPE) combined with GC-MS as well as LC-MS-MS confirmed this method as an easy and reliable protocol, even for the monitoring of matrix-loaded wastewater. The analysis of real samples established the feasibility of the technique.

Calibration↗

[Impact of a PACS/RIS-integrated speech recognition system on radiology reporting time and report availability].

PURPOSE: Quantification of the impact of a PACS/RIS-integrated speech recognition system (SRS) on the time expenditure for radiology reporting and on hospital-wide report availability (RA) in a university institution. MATERIAL AND METHODS: In a prospective pilot study, the following parameters were assessed for 669 radiographic examinations (CR): 1. time requirement per report dictation (TED: dictation time (s)/number of images [examination] x number of words [report]) with either a combination of PACS/tape-based dictation (TD: analog dictation device/mini-cassette/transcription) or PACS/RIS/speech recognition system (RR: remote recognition/transcription and OR: online recognition/self-correction by radiologist), respectively, and 2. the Report Turnaround Time (RTT) as the time interval from the entry of the first image into the PACS to the available RIS/HIS report. Two equal time periods were chosen retrospectively from the RIS database: 11/2002 - 2/2003 (only TD) and 11/2003 - 2/2004 (only RR or OR with speech recognition system [SRS]). The mid-term (> or = 24 h, 24 h intervals) and short-term (< 24 h, 1 h intervals) RA after examination completion were calculated for all modalities and for CR, CT, MR and XA/DS separately. The relative increase in the mid-term RA (RIMRA: related to total number of examinations in each time period) and increase in the short-term RA (ISRA: ratio of available reports during the 1st to 24th hour) were calculated. RESULTS: Prospectively, there was a significant difference between TD/RR/OR (n = 151/257/261) regarding mean TED (0.44/0.54/0.62 s [per word and image]) and mean RTT (10.47/6.65/1.27 h), respectively. Retrospectively, 37 898/39 680 reports were computed from the RIS database for the time periods of 11/2002 - 2/2003 and 11/2003 - 2/2004. For CR/CT there was a shift of the short-term RA to the first 6 hours after examination completion (mean cumulative RA 20 % higher) with a more than three-fold increase in the total number of available reports within 24 hours (all modalities). The RIMRA for CR/CT/MR was 3.1/5.8/4.0 in the first 24 hours, and 2.0 for XA/DS in the second 24-hour interval. CONCLUSION: In comparison to tape-based dictation, an SRS results in a significantly higher primary time expenditure and a modified report dictation workflow. In a university institution, a PACS/RIS-integrated SRS achieves a marked improvement in both short- and mid-term RA which eventually results in an improvement in patient care.

Efficiency, Organizational↗

Optimized method for the determination of 25 polychlorinated biphenyls in water samples using stir bar sorptive extraction followed by thermodesorption-gas chromatography/mass spectrometry.

An optimized method using stir bar sorptive extraction (SBSE) for the determination of 25 polychlorinated biphenyls (PCBs) from water samples among them three of the most toxic coplanar PCBs (PCB 77, PCB 126 and PCB 169) was developed. Since the investigated PCBs comprise all steps of chlorination (from PCB 1 as monochlorobiphenyl to PCB 209 as decachlorobiphenyl) the results should be representative for the total class of the 209 PCB congeners. For 8 ml spiked water samples with 2 ml methanol addition and 2 h exposure time of stir bars recoveries between 28% (PCB 209) and 93% (PCB 1, PCB 52, PCB 77) were found. Detection limits between 0.05 ng/l and 0.15 ng/l were calculated for the combination of SBSE and thermodesorption-GC/MS. The procedure was applied to the investigation of groundwater and river water samples from the industrial region of Bitterfeld northern Leipzig, Germany.

Gas Chromatography-Mass Spectrometry↗

Determination of phenols in lake and ground water samples by stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry.

A simple and inexpensive method for sorptive extraction of phenols from water samples is presented. A polydimethyl siloxane (PDMS) stir bar (Twister) is used as an extraction medium for derivatized phenols, which is thermally desorbed and analyzed by gas chromatography-mass spectrometry (GC-MS). Its performance was illustrated and evaluated for the enrichment of microg l(-1) to ng l(-1) of phenol and selected chlorophenols in water samples. The method showed good linearity, recoveries and blank levels, as well as advantages such as sensitivity, simplicity, low cost and high feasibility, being successfully applied for the analysis of phenolic compounds in natural water samples.

Calibration↗

Determination of Ochratoxin A in small volumes of human blood serum.

A new simple and rapid method for analysing Ochratoxin A (OTA) in small volumes of human blood serum using capillary zone electrophoresis coupled to laser-induced fluorescence is described. The clean-up procedure solely consists of a double extraction step. To improve the reproducibility of migration times and quantification, two internal standards were used. The limit of detection was 0.55 ng/ml, with a linear range of 1-100 ng/ml of OTA in spiked human blood serum. The method is used to rapidly screen suspected patients.

Humans↗

Polydimethylsiloxane rod extraction, a novel technique for the determination of organic micropollutants in water samples by thermal desorption-capillary gas chromatography-mass spectrometry.

A novel, simple and inexpensive approach to absorptive extraction of organic compounds from environmental samples is presented. It consists of a polydimethylsiloxane rod used as an extraction media, enriched with analytes during shaking, then thermally desorbed and analyzed by GC-MS. Its performance was illustrated and evaluated for the enrichment of sub- to ng/l of selected chlorinated compounds (chlorobenzenes and polychlorinated biphenyls) in water samples. The new approach was compared to the stir bar sorptive extraction performance. A natural ground water sample from Bitterfeld, Germany, was also extracted using both methods, showing good agreement. The proposed approach presented good linearity, high sensitivity, good blank levels and recoveries comparable to stir bars, together with advantages such as simplicity, lower cost and higher feasibility.

Dimethylpolysiloxanes↗

Diffusion-based calibration for solid-phase microextraction of benzene, toluene, ethylbenzene, p-xylene and chlorobenzenes from aqueous samples.

Short-term solid-phase microextraction (SPME) was performed to test a recently proposed semi-empirical model for the prediction of concentrations of analyte in water samples from the fibre-extracted mass without further calibration. The mass uptake rates obtained for benzene, toluene, ethylbenzene and p-xylene (BTEX) differ considerably from the before published, showing that interfibre comparability is a serious issue. The relative prediction errors are between -55% for benzene and +82% for p-dichlorobenzene under optimal conditions, i.e. they are by an order of magnitude higher than originally published. A sensitivity analysis shows the dominant influence of the estimated thickness of the diffusional boundary layer around the fibre on the concentration predicted. Empirical modification of the model equation for this parameter yields satisfactory results under the conditions tested for both BTEX and the selected chlorobenzenes.

Benzene↗

Membrane-assisted solvent extraction of polychlorinated biphenyls in river water and other matrices combined with large volume injection-gas chromatography-mass spectrometric detection.

Membrane-assisted solvent extraction was applied to the determination of polychlorinated biphenyls (PCBs) in aqueous samples. The apparatus of membrane-assisted solvent extraction consisted of a 20 ml headspace vial which was filled with 15 ml of the aqueous sample. The membrane bag was placed into the vial and the extraction took place in an agitator. After extraction, the analytes were transferred into the inlet of a gas chromatograph by large volume injection. A mass-selective detector was used. The whole procedure was fully automated. The work included optimization of the extraction conditions (stirring rate and extraction time) and the influence of matrix effects like salt addition and the presence of organic solvents was studied. Calibration was performed using injection volumes of 100 and 400 microl. Several parameters like linearity and reproducibility of the procedure were determined. At optimized conditions detection limits in the ng/l range were achieved. The effectiveness of the method towards real samples was tested by analyzing river water, white wine and apple juice.

Gas Chromatography-Mass Spectrometry↗

Solid-phase microextraction fibre-water distribution constants of more hydrophobic organic compounds and their correlations with octanol-water partition coefficients.

Fibre coating-water distribution constants (Kfw) of more hydrophobic chemicals were determined with six different solid-phase microextraction fibre types (including a polyoctylmethylsiloxane (C8) prototype) by fibre exposure to agitated large-volume water samples lasting several days. The results obtained are comparable with Kfw values obtained under dynamic conditions. Octanol-water partition coefficients (Kow) were measured with the mixture of distributing substances to examine log Kfw-log Kow relationships based on a consistent dataset. Kfw values obtained with liquid polymer fibre coatings correlate reasonably well with the hydrophobicity of the test compounds (with decreasing sensitivity in the following order: 7 microm polydimethylsiloxane (PDMS)>100 microm PDMS>C8>polyacrylate) whereas this is not the case with the PDMS-divinylbenzene (DVB) and Carbowax-DVB fibres, partially porous coatings which provide the highest Kfw values for all substances tested.

Octanols↗

One-step cleanup for PAH residue analysis in plant matrices using size-exclusion chromatography.

A new one-step cleanup procedure, based on size-exclusion chromatography (SEC), usable for the extracts from accelerated solvent extraction (ASE), Soxhlet extraction, or ultrasonic extraction (USE), is described. The method is suitable for the determination of polycyclic aromatic hydrocarbons (PAHs), especially from very complicated plant matrices (e.g. pine needles, deciduous leaves, mosses). The main improvement compared with previous conventional procedures is that analyte peaks barely overlap with matrix peaks in the chromatograms and that it is a very rapid and simple one-step procedure with clearly improved analytical performance. Essential advantages of this SEC procedure are the sharper GC-MS chromatograms for the PAH fraction at retention times between 9.2 and 12.0 min, distinctly separated substance peaks resulting in better analysis, shorter running times, and lower solvent consumption.

Acer↗

Trace analysis of technical nonylphenol, bisphenol A and 17alpha-ethinylestradiol in wastewater using solid-phase microextraction and gas chromatography-mass spectrometry.

To enable high sample throughput, an automated solid-phase microextraction (SPME) method coupled with GC-MS for the trace analysis of technical nonylphenol, bisphenol A and 17alpha-ethinylestradiol was developed. The extraction performance of different SPME fibre coatings was examined, with polyacrylate proving most suitable. Although study of the extraction time showed that the analytes have not reached equilibrium after 3 h, as a compromise an extraction time of 1 h was applied in all the experiments with detection limits between 0.04 and 1 microg l(-1) for wastewater effluent. The mean reproducibility of the technique is 8% RSD. Carry-over effects are negligible. The linearity of calibration curves ranges over three orders of magnitude. The method was tested for determining the analytes in influents and effluents of constructed wetland plants and in model wastewater used in laboratory experiments.

Benzhydryl Compounds↗

Selective enrichment of sulfides, thiols and methylthiophosphates from water samples on metal-loaded cation-exchange materials for gas chromatographic analysis.

The suitability of using metal-loaded sorbents for solid-phase extraction to enrich organic sulfur compounds from water samples was studied. To test the retention behavior of a number of sulfides, thiols and methylthiophosphates, a cation-exchanger was loaded with various metal ions. The elution behavior of sulfur compounds was investigated with different solvents. A combination of Pb2+-modified cation-exchanger as sorbent and CS2 (1%, v/v) in toluene proved to be the most suitable approach for the given problem. Using GC with a pulsed flame photometric detector yielded detection limits of between 0.6 and 2.9 microg/l. The results showed good reproducibility with relative standard deviations of 2-11%.

Calibration↗

Solid-phase microextraction of phthalates from water.

Solid-phase microextraction (SPME) with six different non-polar and polar fibres was used to extract seven phthalate esters from water samples for analysis by gas chromatography-mass spectrometry. With regard to extraction efficiency and repeatability of the extractions, the 70-microm Carbowax-divinylbenzene fibre was especially suitable for the selected phthalates with water solubilities between 4200 mg l(-1) (dimethyl phthalate) and 0.0003 mg l(-1) (di-n-octyl phthalate). Linearity was controlled in the range between 0.02 and 10 microg l(-1). In analysed drinking water samples from Leipzig (Germany) and Katowice (Poland) four of the investigated phthalates [diethyl phthalate, di-n-butyl phthalate, butylbenzyl phthalate and di(2-ethylhexyl) phthalate] were found to be present in concentrations between 0.02 and 0.6 microg 1(-1).

Calibration↗

Membrane-enclosed sorptive coating. an integrative passive sampler for monitoring organic contaminants in water.

An integrative sampler that consists of a bar coated with poly(dimethylsiloxane) (PDMS) enclosed in a dialysis membrane bag has been developed combining the advantages of the passive sampling approach with solventless preconcentration of organic solutes from aqueous matrixes and subsequent desorption of the sequestered analytes on-line with a capillary GC/MS system. The performance of the sampler was tested for integrative sampling of hydrophobic persistent organic pollutants including gamma-hexachlorocyclohexane, hexachlorobenzene, 2,2'-bis(4-chlorophenyl)-1,1'-dichloroethylene, polycyclic aromatic hydrocarbons, and polychlorinated biphenyls in the laboratory in a continuous-flow system. Linear uptake of all test analytes during exposure periods up to one week has been observed, and concentration proportionality of response of the sampler has been demonstrated. Over the range of controlled laboratory conditions, the magnitude of sampling rate values varied from 47 to 700 microL h(-1) per sampler. The uptake rate of chemicals was dependent on their molecular mass, as well as on the partition coefficient between the PDMS and water. A decrease in sampling rates with decreasing water temperature was observed. The sampling device has the potential to detect low aqueous concentrations (ng to pg L(-1)) of test substances.

Adsorption↗

Combining membrane extraction with mobile gas chromatography for the field analysis of volatile organic compounds in contaminated waters.

A mobile gas chromatographic device (Airmobtx HC 1000 monitor manufactured by Airmotec, Germany), originally designed for the analysis of benzene, toluene, ethylbenzene and xylenes (BTEX) in air, was connected to a flow cell for dynamic membrane extraction. Volatile organic compounds (VOCs) diffuse out of a water stream through a hollow fibre, are enriched onto sorption tubes integrated in the mobile device, and are then thermally desorbed and analysed by gas chromatography-flame ionisation detection. Battery operation of the device enables continuous on-site analysis of VOCs. Influences of the water flow-rate on system response and memory effects were investigated. The linear range of the method depends on the flow-rate of the water sample and did not exceed two orders of magnitude. The detection limits for trichloroethene, chlorobenzene and the BTEX compounds were found to be between 0.1 and 1.0 microg/l using a water flow-rate of 30 ml/min. Dynamic membrane extraction combined with the mobile gas chromatographic device was used for the on-site analysis of contaminated waters in the area of Leipzig.

Benzene↗

Use of semipermeable membrane devices (SPMDs). Determination of bioavailable, organic, waterborne contaminants in the industrial region of Bitterfeld, Saxony-Anhalt, Germany.

Triolein-containing semipermeable membrane devices (SPMDs) were employed as passive samplers to provide data on the bioavailable fraction of organic, waterborne, organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polynuclear aromatic hydrocarbons (PAHs) in streams flowing through a highly polluted industrial area of Bitterfeld in Saxony-Anhalt, Germany. The contamination of the region with organic pollutants originates in wastewater effluents from the chemical industry, from over one-hundred years of lignite exploitation, and from chemical waste dumps. The main objective was to characterise time-integrated levels of dissolved contaminants, to use them for identification of spatial trends of contamination, and their relationship to potential pollution sources. SPMDs were deployed for 43 days in the summer of 1998 at four sampling sites. The total concentration of pollutants at sampling sites was found to range from a low of 0.8 microgram/SPMD to 25 micrograms/SPMD for PAHs, and from 0.4 microgram/SPMD to 22 micrograms/SPMD for OCPs, respectively. None of the selected PCB congeners was present at quantifiable levels at any sampling site. A point source of water pollution with OCPs and PAHs was identified in the river system considering the total contaminant concentrations and the distribution of individual compounds accumulated by SPMDs at different sampling sites. SPMD-data was also used to estimate average ambient water concentrations of the contaminants at each field site and compared with concentrations measured in bulk water extracts. The truly dissolved or bioavailable portion of contaminants at different sampling sites ranged from 4% to 86% for the PAHs, and from 8% to 18% for the OCPs included in the estimation. The fraction of individual compounds found in the freely dissolved form can be attributed to the range of their hydrophobicity. In comparison with liquid/liquid extraction of water samples, the SPMD method is more suitable for an assessment of the background concentrations of hydrophobic organic contaminants because of substantially lower method quantification limits. Moreover, contaminant residues sequestered by the SPMDs represent an estimation of the dissolved or readily bioavailable concentration of hydrophobic contaminants in water, which is not provided by most analytical approaches.

Environmental Monitoring↗

Polyaromatic hydrocarbon concentrations and patterns in sediments and surface water of the Mansfeld region, Saxony-Anhalt, Germany.

The composition and spatial distribution of polyaromatic hydrocarbons (PAHs) and their relation to potential pollution sources were investigated in the Böse Sieben Creek, Saxony-Anhalt, Germany, using two techniques: semipermeable membrane devices (SPMDs) and sediment analysis. SPMD is an integrative device that passively samples hydrophobic chemicals of low to moderate molecular weight (< 600 Da) in water. SPMDs were placed in water for 34 days at three sites where sediments were also sampled. Fifteen PAHs were determined in SPMDs and in sediment samples to evaluate the concentration levels and specific PAH patterns. Time-weighted average aqueous PAH concentrations were estimated from the PAH amount accumulated in SPMDs during the deployment period using previously reported sampling rates. Sediment-water partition coefficients were used to estimate PAH concentrations in pore water from sediments. Calculated pore water concentrations were, on average, almost three orders of magnitude higher than those calculated from SPMDs. Thus, in addition to contamination from other sources, the water concentration at the sampling sites might be elevated due to contaminant mobilization from historically contaminated sediments. Relative PAH patterns from SPMDs and sediment were compared using principal component analysis, and were correlated with the PAH patterns from different potential contamination sources, including Theisen sludge, one of the by-products of the smelting process for copper production in the region in the past, which is likely to be the main contamination source of PAHs. Moreover, three origin indices (concentration ratios of PAH isomer pairs) were used to evaluate the suitability of these compounds as tracers to distinguish between the contamination arising from different sources. The evaluation of contaminant patterns permits the conclusion that the PAHs are of pyrolytic, industrial origin, possibly including contamination by Theisen sludge, and rules out a petrogenic source for the hydrocarbons.

Environmental Monitoring↗

Determination of polycyclic aromatic hydrocarbons in waste water by off-line coupling of solid-phase microextraction with column liquid chromatography.

A new method for the determination of polycyclic aromatic hydrocarbons (PAHs) in waste water using solvent-free solid-phase microextraction (SPME) is described. The PAHs are extracted with a 100 microm polydimethylsiloxane (PDMS) fiber, desorbed in 40 microl acetonitrile and measured with LC and fluorescence detection. The detection limits of this very simple method under the given conditions (extraction from 5 ml sample, extraction time 1 h) are in the range of 1-6 ng l(-1). The standard deviations (n = 6) at a concentration level of 0.8 microg l(-1) are between 1.8 and 14.4%. The procedure was used for the determination of PAHs in contaminated water samples.

Chromatography, Liquid↗