Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

The physical characteristics of a clinical prototype amorphous silicon-based flat panel imager for full-breast digital mammography have been investigated. The imager employs a thin thallium doped CsI scintillator on an amorphous silicon matrix of detector elements with a pixel pitch of 100 microm. Objective criteria such as modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), and noise equivalent quanta were employed for this evaluation. The presampling MTF was found to be 0.73, 0.42, and 0.28 at 2, 4, and 5 cycles/mm, respectively. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 55% at close to zero spatial frequency at an exposure of 32.8 mR, and decreases to approximately 40% at a low exposure of 1.3 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.

Algorithms↗

Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications.

We report the performance of a 41 X 41-cm2 amorphous silicon-based flat panel detector designed for radiographic imaging applications. The detector consists of an array of photodiodes and thin film transistor switches on a 0.2-mm pitch with an overlying thallium-doped cesium iodide scintillator. The performance of the detector was evaluated through measurement of the frequency-dependent detective quantum efficiency [DQE(f)]. Measurements of the characteristic curve and modulation transfer function (MTF) are also reported. All measurements were made in a radiographic imaging mode with a readout time of 125 ms. We evaluated a total of 15 detectors. One detector was characterized at a range of exposures and at three different electronic gain settings. Measurements of DQE(f) and MTF were also performed as a function of position on one detector. The measured DQE at an exposure of about 1 mR was 0.66 at zero spatial frequency and fell smoothly with frequency to a value of 0.24 at the Nyquist frequency, 2.5 cycles/mm. The DQE is independent of exposure for exposures in the upper 80% of each gain range, but is reduced somewhat at lower exposures because of the influence of additive system noise. The reduction can be controlled by adjusting the electronic gain. For a gain that allows a maximum exposure of 5 mR, the DQE at 0.056 mR was 0.64 at zero frequency and 0.19 at 2.5 cycles/mm. The standard deviation in DQE among measurements on different detectors was less than 0.02 at any frequency. The presampling MTF was 0.26 at 2.5 cycles/mm. The standard deviation in MTF among measurements on different detectors was less than 0.01 at any frequency. Both MTF and DQE were substantially independent of position on the detector.

Biophysical Phenomena↗