PubMed Health⌕ Search

Biomedical subjects

P R Rijnbeek

Publications and source records attributed to P R Rijnbeek.

6 recordsLinked to original sources

Minimum bandwidth requirements for recording of pediatric electrocardiograms.

BACKGROUND: Previous studies that determined the frequency content of the pediatric ECG had their limitations: the study population was small or the sampling frequency used by the recording system was low. Therefore, current bandwidth recommendations for recording pediatric ECGs are not well founded. We wanted to establish minimum bandwidth requirements using a large set of pediatric ECGs recorded at a high sampling rate. METHODS AND RESULTS: For 2169 children aged 1 day to 16 years, a 12-lead ECG was recorded at a sampling rate of 1200 Hz. The averaged beats of each ECG were passed through digital filters with different cut off points (50 to 300 Hz in 25-Hz steps). We measured the absolute errors in maximum QRS amplitude for each simulated bandwidth and determined the percentage of records with an error >25 microV. We found that in any lead, a bandwidth of 250 Hz yields amplitude errors <25 microV in >95% of the children <1 year. For older children, a gradual decrease in ECG frequency content was demonstrated. CONCLUSIONS: We recommend a minimum bandwidth of 250 Hz to record pediatric ECGs. This bandwidth is considerably higher than the previous recommendation of 150 Hz from the American Heart Association.

Adolescent↗

A new approach to mechanical simulation of lung behaviour: pressure-controlled and time-related piston movement.

A mechanical lung simulator is described (an extension of a previous mechanical simulator) which simulates normal breathing and artificial ventilation in patients. The extended integration of hardware and software offers many new possibilities and advantages over the former simulator. The properties of components which simulate elastance and airway resistance of the lung are defined in software rather than by the mechanical properties of the components alone. Therefore, a more flexible simulation of non-linear behaviour and the cross-over effects of lung properties is obtained. Furthermore, the range of lung compliance is extended to simulate patients with emphysema. The dependency of airway resistance on lung recoil pressure and transmural pressure of the airways can also be simulated. The new approach enables one to incorporate time-related mechanics such as the influence of lung viscosity or cardiac oscillation. The different relations defined in the software can be changed from breath to breath. Three simulations are presented: (1) computer-controlled expiration in the artificially ventilated lung; (2) simulation of normal breathing; and (3) simulation of viscoelastance and cardiac influences during artificial ventilation. The mechanical simulator provides a reproducible and flexible environment for testing new software and equipment in the lung function laboratory and in intensive care, and can be used for instruction and training.

Biomechanical Phenomena↗

New normal limits for the paediatric electrocardiogram.

AIMS: Previous studies that determined the normal limits for the paediatric ECG had their imperfections: ECGs were recorded at a relatively low sampling rate, ECG measurements were conducted manually, or normal limits were presented for only a limited set of parameters. The aim of this study was to establish an up-to-date and complete set of clinically relevant normal limits for the paediatric ECG. METHODS AND RESULTS: ECGs from 1912 healthy Dutch children (age 11 days to 16 years) were recorded at a sampling rate of 1200 Hz. The digitally stored ECGs were analysed using a well-validated ECG computer program. The normal limits of all clinically relevant ECG measurements were determined for nine age groups. Clinically significant differences were shown to exist, compared with previously established normal limits. Sex differences could be demonstrated for QRS duration and several amplitude measurements. CONCLUSIONS: These new normal limits differ substantially from those commonly used and suggest that diagnostic criteria for the paediatric ECG should be adjusted.

Adolescent↗

PEDMEANS: a computer program for the interpretation of pediatric electrocardiograms.

The interpretation pediatric electrocardiograms (ECGs) is complicated because of the strong age-dependency of the diagnostic criteria. We wanted to develop and evaluate a computer program for the interpretation of pediatric 12-lead ECGs. Continuous age-dependent normal limits were established based on ECGs from 1,912 healthy Dutch children. Additionally, a reference interpretation was obtained for 1,718 ECGs recorded at the Sophia Children's Hospital. The total set of ECGs was divided in a training set of 1076 ECGs and a test set of 642 ECGs. All ECGs were recorded at a sampling rate of 1,200 Hz. Based on the normal limits and the training set, diagnostic rules were formalized in an iterative process by using expert interviews and automatic rule induction. The resultant rules were evaluated on the test set. The performance of the program, on our study population, appears to justify its use in a clinical setting. Preferably, the program should also be evaluated in other clinical centers.

Algorithms↗

Effects of fluticasone propionate on methacholine dose-response curves in nonsmoking atopic asthmatics.

Methacholine is frequently used to determine bronchial hyperresponsiveness (BHR) and to generate dose-response curves. These curves are characterized by a threshold (provocative concentration of methacholine producing a 20% fall in forced expiratory volume in one second (PC20) = sensitivity), slope (reactivity) and maximal response (plateau). We investigated the efficacy of 12 weeks of treatment with 1,000 microg fluticasone propionate in a double-blind, placebo-controlled study in 33 atopic asthmatics. The outcome measures used were the influence on BHR and the different indices of the methacholine dose-response (MDR) curve. After 2 weeks run-in, baseline lung function data were obtained and a MDR curve was measured with doubling concentrations of the methacholine from 0.03 to 256 mg x mL(-1). MDR curves were repeated after 6 and 12 weeks. A recently developed, sigmoid cumulative Gaussian distribution function was fitted to the data. Although sensitivity was obtained by linear interpolation of two successive log2 concentrations, reactivity, plateau and the effective concentration at 50% of the plateau value (EC50) were obtained as best fit parameters. In the fluticasone group, significant changes occurred after 6 weeks with respect to means of PC20 (an increase of 3.4 doubling doses), plateau value fall in forced expiratory volume in one second (FEV1) (from 58% at randomization to 41% at 6 weeks) and baseline FEV1 (from 3.46 to 3.75 L) in contrast to the placebo group. Stabilization occurred after 12 weeks. Changes for reactivity were less marked, whereas changes in log, EC50 were not significantly different between the groups. We conclude that fluticasone is very effective in decreasing the maximal airway narrowing response and in increasing PC20. However, it is likely that part of this increase is related to the decrease of the plateau of maximal response.

Administration, Topical↗