PubMed Health⌕ Search

Biomedical subjects

P Rahko

Publications and source records attributed to P Rahko.

4 recordsLinked to original sources

Ultrasonic imaging of myocardial strain using cardiac elastography.

Clinical assessment of myocardial ischemia based on visually-assessed wall motion scoring from echocardiography is semiquantitative, operator dependent, and heavily weighted by operator experience and expertise. Cardiac motion estimation methods such as tissue Doppler imaging, used to assess myocardial muscle velocity, provides quantitative parameters such as the strain-rate and strain derived from Doppler velocity. However, tissue Doppler imaging does not differentiate between active contraction and simple rotation or translation of the heart wall, nor does it differentiate tethering (passively following) tissue from active contraction. In this paper, we present a strain imaging modality called cardiac elastography that provides two-dimensional strain information. A method for obtaining and displaying both directional and magnitude cardiac elastograms and displaying strain over the entire cross-section of the heart is described. Elastograms from a patient with coronary artery disease are compared with those from a healthy volunteer. Though observational, the differences suggest that cardiac elastography may be a useful tool for assessment of myocardial function. The method is two-dimensional, real time and avoids the disadvantage of observer-dependent judgment of myocardial contraction and relaxation estimated from conventional echocardiography.

Aged↗

Beneficial effects of pimobendan on exercise tolerance and quality of life in patients with heart failure. Results of a multicenter trial. The Pimobendan Multicenter Research Group.

BACKGROUND: This multicenter trial was conducted to determine the efficacy and safety of pimobendan, an inotropic agent with calcium-sensitizing properties and activity as a phosphodiesterase inhibitor, in patients with heart failure. METHODS AND RESULTS: One hundred ninety-eight ambulatory patients with symptoms of moderate to severe heart failure despite therapy with digitalis and diuretics with or without a single vasodilator were randomly assigned to receive either placebo (n = 49) or pimobendan (n = 149) in a double-blind fashion for 12 weeks. A dose range of pimobendan was used including 2.5 (n = 49), 5 (n = 51), or 10 mg/day (n = 49). One hundred fifty-eight (80%) patients were taking a converting enzyme inhibitor (CEI) and 28 (14%) patients were taking a non-CEI vasodilator. At end point, the 5-mg dose of pimobendan significantly increase exercise duration compared with placebo (121.6 +/- 19.1 seconds, p less than 0.001), whereas the 10-mg dose produced an increase of borderline significance (81.1 +/- 19.5 seconds, p = 0.05). Peak VO2 was significantly increased by 2.23 +/- 0.58 ml/kg/min in the 5-mg group (p less than 0.01 versus placebo). Furthermore, quality of life measured with the Minnesota Living With Heart Failure Questionnaire improved by 8.5 +/- 2.3 units in the 5-mg group compared with 1.3 +/- 2.2 units in the placebo group (p less than 0.01). There were a total of 23 all-cause hospitalizations in the placebo group, which was significantly greater compared with 33 in the three groups treated with pimobendan (p less than 0.01). There were no significant differences between the placebo and pimobendan groups with respect to changes in ejection fraction and plasma norepinephrine measured at baseline and at the completion of the 12-week study, proarrhythmic effect, or the number of patients with a significant adjustment in background therapy. Eleven patients died, including three (6%) on placebo and eight (5%) on pimobendan (p = NS). Among all adverse events, headache tended to be more common in the pimobendan groups compared with placebo, with the incidence increasing with dose (p less than 0.05). CONCLUSIONS: These data demonstrate that pimobendan significantly increases exercise duration, peak VO2, and quality of life in patients with heart failure. Pimobendan appears to be useful adjunctive therapy when added to digitalis, diuretics, and vasodilators.

Analysis of Variance↗

Transthoracic 2D echocardiographic guidance for percutaneous removal of a nonopaque intracardiac catheter fragment.

A radiolucent fragment of a fractured central venous catheter embolized to the right heart resulting in life-threatening dysrhythmias in a middle-aged male patient who had undergone orthotopic liver transplantation 1 day earlier. The fragment was removed via the right transjugular route using sonographic guidance to entrap the fragment with a brightly echogenic snare. The technique described protects the caval anastomoses in the liver transplant recipient and overcomes the limitation of fluoroscopy in removing radiolucent bodies.

Cardiac Catheterization↗