PubMed Health⌕ Search

Biomedical subjects

P Raimondi

Publications and source records attributed to P Raimondi.

12 recordsLinked to original sources

Transarticular repair of the brachial plexus. Case report.

This paper illustrates the repair of a complex and unusually placed iatrogenic injury of the brachial plexus. The authors present the case of a 36-year old woman, musician (piano solista), with a dumbbell tumour of the brachial plexus. A general surgeon performed a gross total removal of the tumour, cutting it flush with the exit of the neuroforamen and this resulted in a severe upper brachial plexus injury. Four months later, the brachial plexus was repaired with a nerve graft, using a double extraforaminal and preforaminal approach via the transarticular route. The surgical procedure proved to be effective and without significant consequences for the patient.

Adult↗

Ultrarelativistic-positron-beam transport through meter-scale plasmas.

We report on the first study of the dynamic transverse forces imparted to an ultrarelativistic positron beam by a long plasma in the underdense regime. Focusing of the 28.5 GeV beam is observed from time-resolved beam profiles after the 1.4 m plasma. The strength of the imparted force varies along the approximately 12 ps full length of the bunch as well as with plasma density. Computer simulations substantiate the longitudinal aberration seen in the data and reveal mechanisms for emittance degradation.

Journal Article↗

Transverse envelope dynamics of a 28.5-GeV electron beam in a long plasma.

The transverse dynamics of a 28.5-GeV electron beam propagating in a 1.4 m long, (0-2)x10(14) cm(-3) plasma are studied experimentally in the underdense or blowout regime. The transverse component of the wake field excited by the short electron bunch focuses the bunch, which experiences multiple betatron oscillations as the plasma density is increased. The spot-size variations are observed using optical transition radiation and Cherenkov radiation. In this regime, the behavior of the spot size as a function of the plasma density is well described by a simple beam-envelope model. Dynamic changes of the beam envelope are observed by time resolving the Cherenkov light.

Journal Article↗

X-ray emission from betatron motion in a plasma wiggler.

The successful utilization of an ion channel in a plasma to wiggle a 28.5-GeV electron beam to obtain broadband x-ray radiation is reported. The ion channel is induced by the electron bunch as it propagates through an underdense 1.4-meter-long lithium plasma. The quadratic density dependence of the spontaneously emitted betatron x-ray radiation and the divergence angle of approximately (1-3)x10(-4) radian of the forward-emitted x-rays as a consequence of betatron motion in the ion channel are in good agreement with theory. The absolute photon yield and the peak spectral brightness at 14.2-keV photon energy are estimated.

Journal Article↗

Observation of plasma focusing of a 28.5 GeV positron beam.

The observation of plasma focusing of a 28.5 GeV positron beam is reported. The plasma was formed by ionizing a nitrogen jet only 3 mm thick. Simultaneous focusing in both transverse dimensions was observed with effective focusing strengths of order tesla per micron. The minimum area of the beam spot was reduced by a factor of 2.0+/-0.3 by the plasma. The longitudinal beam envelope was measured and compared with numerical calculations.

Journal Article↗

Novel final focus design for future linear colliders.

The length, complexity, and cost of the present final focus designs for linear colliders grow very quickly with the beam energy. In this Letter, a novel final focus system is presented and compared with the one proposed for the Next Linear Collider (NLC Zeroth-Order Design Report, edited by T. O. Raubenheimer, SLAC Report No. 474, 1996). This new design has fewer optical elements and is much shorter, nonetheless achieving better chromatic properties. Moreover, the new system is more suitable for operation over a larger energy range.

Journal Article↗

Reverse dorsal digital island flap.

The anatomic and clinical bases for a reliable and versatile homodigital flap for covering difficult distal dorsal and dorsolateral wounds of the long fingers are presented. This one-step procedure, which uses the dorsal skin of the first or second phalanx transposed as a reverse island flap, preserving the collateral nerve and artery to the fingertip, has proved valuable in salvaging the severely injured digits of nine patients (for a total of 12 flaps). It would seem to be a relatively simple way of achieving early recovery because it does not require distant flap reconstruction, the immobilization of adjacent digits, or homodigital flaps that might jeopardize an already injured finger. Furthermore, it reduces the time of hospitalization and improves patient welfare.

Adult↗

D-dimer plasma concentration in various clinical conditions: implication for the use of this test in the diagnostic approach of venous thromboembolism.

Plasma measurement of D-Dimer (DD) represents a definite aid in the diagnostic approach of outpatients with suspected venous thromboembolism (VTE). However, the high sensitivity (about 95%) of the test which allows to rule out VTE when concentrations are below a given cutoff (500 micrograms/L as measured by the ELISA technique) is counterbalanced by a poor specificity (about 40%). Because the specificity might even be lower in patients who are hospitalized we determined the DD plasma concentration in 255 patients who were consecutively admitted in general internal medicine wards with various pathological conditions. The proportion of patients who had DD levels below the cutoff of 500 micrograms/L was 6% (1/18) in patients with VTE and 22% (52/237) in hospitalized patients without VTE: the figure was 21% in patients with pulmonary infections, 14% in patients with other infections, 11% in patients with neoplastic diseases, 34% in patients with coronary or cerebrovascular disease, 19% in patients with cardiac failure, 69% in patients with rheumatologic disease and in 16% in subjects with miscellaneous clinical conditions. The high rate of elevated plasma DD in hospitalized patients questions the usefulness of this test in the diagnostic approach of VTE in aged patients who present with concomitant disease like infections, neoplasia, cardiac failure and many other pathological conditions, except rheumatologic affections and coronary or cerebrovascular diseases.

Aged↗

[Vibration, back pain and physical exercise in high-risk professionals: a cross-sectional study].

Repeated loads and vibration stress in professional settings are relevant risk factors for back pain. Aim of this cross-sectional study was to estimate: a) the prevalence of back pain in two high-risk professional samples (helicopter pilots and bus drivers); b) the association between physical/sports exercise and back pain subjective perception across age. Prevalence of back pain is 94% in helicopter pilots and 74% in bus drivers; prevalence of back pain significantly increases with age. The positive effect of regular physical/sports exercise on subjective back pain significantly decreases with age. Physical or sports exercise adapted to structural characteristic of patients can result effective in diminishing personal impairment in subjects at professional risk.

Adolescent↗