In vivo electroporation of skeletal muscle: threshold, efficacy and relation to electric field distribution.

In vivo electroporation is increasingly being used to deliver small molecules as well as DNA to tissues. The aim of this study was to quantitatively investigate in vivo electroporation of skeletal muscle, and to determine the threshold for permeabilization. We designed a quantitative method to study in vivo electroporation, by measuring uptake of (51)Cr-EDTA. As electrode configuration influences electric field (E-field) distribution, we developed a method to calculate this. Electroporation of mouse muscle tissue was investigated using either external plate electrodes or internal needle electrodes placed 4 mm apart, and eight pulses of 99 micros duration at a frequency of 1 Hz. The applied voltage to electrode distance ratio was varied from 0 to 2.0 kV/cm. We found that: (1) the threshold for permeabilization of skeletal muscle tissue using short duration pulses was at an applied voltage to electrode distance ratio of 0.53 kV/cm (+/-0.03 kV/cm), corresponding to an E-field of 0.45 kV/cm; (2) there were two phases in the uptake of (51)Cr-EDTA, the first indicating increasing permeabilization and the second indicating beginning irreversible membrane damage; and (3) the calculated E-field distribution was more homogeneous for plate than for needle electrodes, which was reflected in the experimental results.

Animals↗

The effects of radiofrequency fields on cell proliferation are non-thermal.

The number of reports on the effects induced by radiofrequency (RF) electromagnetic fields and microwave (MW) radiation in various cellular systems is still increasing. Until now no satisfactory mechanism has been proposed to explain the biological effects of these fields. One of the current theories is that heat generation by RF/MW is the cause, in spite of the fact that a great number of studies under isothermal conditions have reported significant cellular changes after exposure to RF/MW. Therefore, this study was undertaken to investigate which effect MW radiation from these fields in combination with a significant change of temperature could have on cell proliferation. The experiments were performed on the same cell line, and with the same exposure system as in a previous work [S. Kwee, P. Raskmark, Changes in cell proliferation due to environmental non-ionizing radiation: 2. Microwave radiation, Bioelectrochem. Bioenerg., 44 (1998), pp. 251-255]. The field was generated by signal simulation of the Global System for Mobile communications (GSM) of 960 MHz. Cell cultures, growing in microtiter plates, were exposed in a specially constructed chamber, a Transverse Electromagnetic (TEM) cell. The Specific Absorption Rate (SAR) value for each cell well was calculated for this exposure system. However, in this study the cells were exposed to the field at a higher or lower temperature than the temperature in the field-free incubator i.e., the temperature in the TEM cell was either 39 or 35 +/- 0.1 degrees C. The corresponding sham experiments were performed under exactly the same experimental conditions. The results showed that there was a significant change in cell proliferation in the exposed cells in comparison to the non-exposed (control) cells at both temperatures. On the other hand, no significant change in proliferation rate was found in the sham-exposed cells at both temperatures. This shows that biological effects due to RF/MW cannot be attributed only to a change of temperature. Since the RF/MW induced changes were of the same order of magnitude at both temperatures and also comparable to our previous results under isothermal conditions at 37 degrees C, cellular stress caused by electromagnetic fields could initiate the changes in cell cycle reaction rates. It is widely accepted that certain classes of heat-shock proteins are involved in these stress reactions.

Algorithms↗

Radio-frequency ring applicator: energy distributions measured in the CDRH phantom.

SAR distributions were measured in the CDRH phantom, a 1 cm fat-equivalent shell filled with an abdomen-equivalent liquid (sigma = 0.4-1.0 S m-1; dimensions 22 x 32 x 57 cm) to demonstrate the feasibility of the ring applicator to obtain deep heating. The ring electrodes were fixed in a PVC tube; diameter 48 cm, ring width 20 cm and gap width between both rings 31.6 cm. Radio-frequency energy was fed to the electrodes at eight points. The medium between the electrodes and the phantom was deionised water. The SAR distribution in the liquid tissue volume was obtained by a scanning E-field probe measuring the E-field in all three directions. With equal amplitude and phase applied to all feeding points, a uniform SAR distribution was measured in the central cross-section at 30 MHz. With RF energy supplied to only four adjacent feeding points (others were connected to a 50 omega load), the feasibility to perform amplitude steering was demonstrated; SAR values above 50% of the maximum SAR were measured in one quadrant only. SAR distributions obtained at 70 MHz showed an improved focusing ability; a maximum at the centre exists for an electric conductivity of the abdomen-equivalent tissue of 0.6 and 0.4 S m-1.

Electromagnetic Fields↗

Deep heating using a movable applicator phased array hyperthermia system. A preclinical feasibility study.

A preclinical evaluation of the 'movable applicator phased array hyperthermia system' was performed. The system employs four coherent applicators enabling power steering by amplitude and phase control. This concept has already been used in other systems, but the combination with a compact applicator design and easy movement of applicators has not been used before. The paper contains a description of the system and a verification of its performance using quality assurance tests with scanned E-field measurements. A clinical simulation was performed in pig to address the clinical feasibility of the system. The target volume was the left kidney. Two heating sessions, with and without occluded blood-flow to the kidney, were performed. In the low-flow experiments a temperature of 48 degrees C and 46 degrees C was obtained in the upper and lower pole of the kidney respectively. For the high-flow experiment the temperature in the upper pole was 48 degrees C.

Animals↗

Incidence of cancer in persons with occupational exposure to electromagnetic fields in Denmark.

Several studies suggest that work in electrical occupations is associated with an increased risk of cancer, mainly leukaemia and brain tumours. These studies may, however, not be representative if there is a publication bias where mainly positive results are reported. To study an unselected population the incidence of cancer was followed up over a 17 year period (1970-87) in a cohort of 2.8 million Danes aged 20-64 years in 1970. Each person was classified by his or her industry and occupation in 1970. Before tabulation of the data on incidence of cancer, each industry-occupation group was coded for potential exposure to magnetic fields above the threshold 0.3 microT. Some 154,000 men were considered intermittently exposed and 18,000 continuously exposed. The numbers for women were 79,000 and 4000 respectively. Intermittent exposure was not associated with an increased risk of leukaemia, brain tumours, or melanoma. Men with continuous exposure, however, had an excess risk of leukaemia (observed (obs) 39, expected (exp) 23.80, obs/exp 1.64, 95% CI 1.20-2.24) with equal contributions from acute and other leukaemias. These men had no excess risk of brain tumours or melanoma. A risk for breast cancer was suggested in exposed men but not in women. The risk for leukaemia in continuously exposed men was mainly in electricians in installation works and iron foundry workers. Besides electromagnetic fields other exposures should be considered as possible aetiological agents.

Adult↗

Multi-applicator hyperthermia system description using scattering parameters.

Hyperthermia systems using electromagnetic phased arrays have often been investigated from a SAR distribution point of view. One of the problems in these systems is that the achieved SAR distribution is different from the intended one because of changes in the generator signals due to mutual coupling between applications. The use of circuit theory and S-parameters in the description of an N-applicator phased array system is introduced in this paper, and a compact matrix equation giving excitation as a function of generator signals is derived. Measurement of the S-parameters is discussed using a phased array deep heating system (Danish Hyperthermia Foundation (DHF)) as an example. In a phantom experiment a significant improvement in the SAR distribution is demonstrated when the developed method is applied.

Electromagnetic Phenomena↗

Quality assurance for radiofrequency regional hyperthermia.

Today most treatments with regional hyperthermia are applied using radiofrequency systems with 'focus' steering by amplitude and phase control. This paper deals with quality assurance procedures developed to ensure controlled and safe treatments in such systems. Our results show how the deviations between requested and observed phase and amplitude vary with frequency, and how these deviations depend on both the geometry of the object (phantom) inside the system and the power level applied. The results also indicate that the investigated systems' internal quality assurance procedures were inadequate and that additional procedures should be applied. Since the system parameters depend on patient and treatment specific conditions it is concluded that there is a need for QA measurements before or during treatment. This paper deals specifically with the commercial BSD-2000 system from BSD Medical Corp. in Salt Lake City, Utah, as installed in Bergen, but the procedure outlined can be applied to other phase and amplitude-controlled RF-RHT systems with only minimal adjustments.

Calibration↗