PubMed Health⌕ Search

Biomedical subjects

P Robyr

Publications and source records attributed to P Robyr.

4 recordsLinked to original sources

Radiofrequency-Driven and Slow-Magic-Angle-Sample-Spinning Polarization-Transfer Techniques: A Comparative Study

The rate constant of radiofrequency-driven (RF-driven) polarization transfer and that of polarization transfer under slow-magic-angle sample spinning (S-MAS) are compared using a model system, polycrystalline alpha-alpha'-13C2-phthalic acid. While the rate constant under RF irradiation in static samples strongly depends on the orientation of the internuclear vector, the rate constant under S-MAS is hardly sensitive to that orientation and, thus, depends almost exclusively on the internuclear distance. Consequently, polarization-transfer rate constants obtained under S-MAS can be interpreted more simply when used to study local order in polycrystalline or amorphous solids. Copyright 1998 Academic Press.

Journal Article↗

Multilayer Gradient Coil Design

In standard cylindrical gradient coils consisting of wires wound in a single layer, the rapid increase in coil resistance with efficiency is the limiting factor in achieving very large magnetic field gradients. This behavior results from the decrease in the maximum usable wire diameter as the number of turns is increased. By adopting a multilayer design in which the coil wires are allowed to spread out into multiple layers wound at increasing radii, a more favorable scaling of resistance with efficiency is achieved, thus allowing the design of more powerful gradient coils with acceptable resistance values. By extending the theory used to design standard cylindrical gradient coils, we have developed mathematical expressions which allow the design of multilayer coils, and the evaluation of their performance. These expressions have been used to design a four-layer, z-gradient coil of 8 mm inner diameter, which has an efficiency of 1.73 Tm-1 A-1, a resistance of 1.8 Omega, and an inductance of 50 µH. This coil produces a gradient which deviates from linearity by less than 5% within a central cylindrical region of 4.5 mm length and 4.5 mm diameter. A coil has been constructed from this design and tested in simple imaging and pulsed gradient spin echo experiments. The resulting data verify the predicted coil performance, thus demonstrating the advantages of using multilayer coils for experiments requiring very large magnetic field gradients. Copyright 1998 Academic Press.

Journal Article↗

Strong gradients for spatially resolved diffusion measurements.

A new multilayer approach to gradient coil design, which allows the production of very strong gradient coils with reasonable resistance and consequent power dissipation, has been developed. Using this approach we have designed and built a strong z-gradient coil that will accommodate vertically mounted samples contained in 5-mm nuclear magnetic resonance tubes. The coil has an efficiency of 1.73 Tm-1A-1, an inductance of 49 microH, and a resistance of 1.8 omega, with a homogeneous volume consisting of a central cylinder of 4.5-mm length and diameter. This coil has been used to monitor the diffusion of water in Nylon 6.6 at room temperature, during desorption. This system is difficult to monitor via nuclear magnetic resonance (NMR), because the diffusion coefficients are typically less than 10(-13) m2s-1, while the T2 relaxation time is less than 1 ms even when the sample is fully saturated. The resulting measurements show a strong concentration dependence of the T2 relaxation time and self-diffusion coefficient of the absorbed water. The measured concentration profiles are consistent with a Fickian diffusion process with a concentration-dependent diffusion coefficient. The measured self-diffusion values are in reasonable agreement with those inferred from the variation of the concentration profiles as a function of time, using the one-dimensional Fickian diffusion equation.

Absorption↗