PubMed Health⌕ Search

Biomedical subjects

P S Astridge

Publications and source records attributed to P S Astridge.

4 recordsLinked to original sources

Failure of plasma atrial natriuretic peptide levels to increase during exercise in patients with chronic atrial fibrillation.

It is generally accepted that plasma atrial natriuretic peptide release occurs secondary to atrial stretch. The influence of coordinated atrial contraction (AC) upon this process is not fully appreciated. The aim of the study was to determine the importance of coordinated AC upon peripheral atrial natriuretic peptide levels (alpha-hANP) during exercise. Peripheral alpha-hANP levels were measured at rest and during exercise in 12 patients with complete heart block (CHB) and permanent rate responsive pacemakers. Seven patients had coordinated AC and five had chronic atrial fibrillation (AF). Each patient performed three treadmill exercise tests. Maximal inspired oxygen volume (VO2 max) was determined during test 1. Tests 2 and 3 were performed to 70% VO2 max, the pacemaker being programmed to either VVI or VVIR mode. Plasma alpha-hANP was measured using a two-site immunoradiometric assay. At rest there was a small but significant difference between the two patient groups: AF 60.2 pg/mL versus AC97.6 pg/mL; P = 0.03. During exercise in the AC patients, there was a significant increase in alpha-hANP levels, in VVIR mode, to 238.4 pg/mL, and in VVI mode, to 207.9 pg/mL, P = 0.002 and 0.003, respectively. In those patients with chronic AF, there was no significant rise or fall in alpha-hANP levels in either pacing mode, VVIR 65.2 pg/mL, VVI 46.6 pg/mL. Previous workers have suggested that alpha-hANP release by nonfunctioning atria is normal. We have shown that the presence of coordinated AC is required for the release of alpha-hANP during exercise in patients with CHB, and that this appears to be independent of ventricular rate.

Adult↗

The response of implanted dual chamber pacemakers to 50 Hz extraneous electrical interference.

Twenty-two patients with dual chamber pacemakers with interchangeable lead configuration were exposed to 50 Hz electromagnetic interference. Current, at corporeal levels from 0-600 microA, was applied between electrodes on shoulders and feet using a bedside injection unit. Pacemaker behavior was monitored with telemetered event markers and intracardiac electrograms. In bipolar mode, noise reversion mode was induced in all except two Medtronic units at high (> 170 microA) levels of corporeal current. In the Intermedics, Siemens Pacesetter, and Telectronics models, onset of noise reversion mode was preceded by a window of inappropriate function, characterized by rate acceleration due to atrial malsensing, or pacemaker inhibition due to ventricular malsensing. In unipolar mode, pacemaker malfunction occurred at much lower current levels. Inappropriate behavior preceded the onset of protective noise reversion mode. During current injection, all pacemakers could be interrogated and reprogrammed, and intracardiac telemetry was reliably obtained except in two Medtronic units at high current levels. No pacemaker was reset by the electrical interference, and no cross-talk was seen. Use of bipolar mode confers a high degree of protection from extraneous electrical interference, but in unipolar mode pacemakers may be inhibited by small amounts of corporeal current, potentially encountered in every day life. The current injection unit allows safe, controllable, and quantifiable investigation of the effects of the electric field induced by a current on implanted pacemakers. Telemetry of annotated intracardiac signals during electromagnetic interference clarifies observations of pacemaker acceleration and inhibition.

Adult↗

Torsades de pointes ventricular tachycardia and terodiline.

We report five patients (four women, one man; mean age 74 years, range 55-87) taking terodiline who had torsades de pointes ventricular tachycardia associated with prolongation of the QT interval. The QT interval was normal before the introduction of terodiline in three patients and returned to normal after terodiline withdrawal in four. Atrioventricular conduction disturbance or bradycardia were evident in all patients. Terodiline should be prescribed with caution to elderly patients.

Aged↗