A novel method for the prediction of functional biological activity of polyethylene wear debris.

The comparative performance of artificial hip joints has been extensively investigated in vitro through measurements of wear volumes. In vivo a major cause of long-term failure is wear-debris-induced osteolysis. These adverse biological reactions are not simply dependent on wear volume, but are also controlled by the size and volumetric concentration of the debris. A novel model is presented which predicts functional biological activity; this is determined by integrating the product of the biological activity function and the volumetric concentration function with the wear volume over the whole particle size range. This model combines conventional wear volume measurements with particle analysis and the output from in vitro cell culture studies to provide a new indicator of osteolytic potential. The application of the model is demonstrated through comparison of the functional biological activity of wear debris from polyethylene acetabular cups articulating under three different conditions in a hip joint simulator.

Biocompatible Materials↗

Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.

The wear debris generated from ultra high molecular weight polyethylene (UHMWPE) have been recognised as one of the major causes of failure in total hip replacements (THR). It is essential to reduce the wear debris generated from UHMWPE acetabular cups in order to minimise this problem. Debris in the submicron size range is believed to have greater osteolytic potential. It is now known that crosslinked UHMWPE acetabular cups have reduced volumetric wear rates but little is known about the influence of crosslinking on the size and morphology of the wear debris. In this study, the wear of grade GUR 1020 crosslinked (vacuum gamma irradiated), GUR 1120 crosslinked (acetylene enhanced irradiated) and non cross linked (ethylene oxide sterilised) GUR 1020 UHMWPE was compared in multidirectional pin-on-plate wear tests under three different counterface conditions (smooth, isotropically rough and scratched counterfaces). Multidirectional motion was chosen because this motion was closer to the relative motion in the natural hip. From this study, better wear resistance of crosslinked UHMWPE compared with non-crosslinked UHMWPE was demonstrated for the smooth counterface conditions. However, in the rough and scratched counterface conditions, the vacuum gamma irradiated crosslinked material produced significantly higher wear rates than the non-crosslinked material. The analysis of the wear debris showed that the majority of the volume of the acetylene enhanced crosslinked UHMWPE wear debris was in the most biologically active size range (0.1 to 0.5 microm). In contrast, the non-crosslinked material and the vacuum gamma irradiated crosslinked material had a greater proportion of the volume of the debris in the larger size ranges which are less biologically active. This has important implications for its osteolytic potential.

Acetylene↗

A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups.

This study validates a hip joint simulator configuration as compared with other machines and clinical wear rates using smooth metal and ceramic femoral heads and ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. Secondly the wear rate of UHMWPE cups is measured in the simulator with deliberately scratched cobalt-chrome heads to represent the type of mild and severe scratch damage found on retrieved heads. Finally, the scratching processes are described and the resulting scratches compared with those found in retrieved cobalt-chrome heads. For smooth cobalt-chrome and zirconia heads the wear rates were found to be statistically similar to other simulator machines and within the normal range found from clinical studies. An increased wear rate was found with cobalt-chrome heads scratched using either the diamond stylus or the bead cobalt-chrome but the greatest increase was with the diamond scratched heads which generated scratches of similar dimensions to those on retrieved heads. A greater than twofold increase in wear rate is reported for these heads when compared with smooth heads. This increased wear rate is, however, still within the limits of data from clinical wear studies.

Acetabulum↗

A study of the wear resistance of three types of clinically applied UHMWPE for total replacement hip prostheses.

Ultra high molecular weight polyethylene (UHMWPE) is routinely used as one half of a bearing couple in clinical orthopaedic applications. This material is generally one of two grades, compression moulded GUR 1120, with a molecular weight of 4.4x 10(6) g mol(-1), or ram extruded GUR 4150HP with a molecular weight of 7.3x10(6) g mol(-1) although other grades are used as well. This study examines the effect of molecular weight and processing method by comparing the wear resistance of these two materials together with a non-standard extruded form of GUR 1120. Wear studies have been conducted against counterface surfaces which represent new and scratch-damaged femoral heads with bovine serum lubricant in a uniaxial reciprocating test configuration. No difference in the wear resistance was found between any material when tested against smooth cobalt chrome counterfaces. On rough cobalt chrome counterfaces, although no statistically significant difference (P>0.05) was found between the extruded and compression moulded GUR 1120, the extruded GUR 4150HP had a consistently better wear resistance. These results are discussed with reference to previous wear studies as well as the physical and mechanical properties of these materials.

Animals↗

A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates.

In some designs of hip joint simulator the cost of building a highly complex machine has been offset with the requirement for a large number of test stations. The application of the wear results generated by these machines depends on their ability to reproduce physiological wear rates and processes. In this study a hip joint simulator has been shown to reproduce physiological wear using only one load vector and two degrees of motion with simplified input cycles. The actual path of points on the femoral head relative to the acetabular cup were calculated and compared for physiological and simplified input cycles. The in vitro wear rates were found to be highly dependent on the shape of these paths and similarities could be drawn between the shape of the physiological paths and the simplified elliptical paths.

Analysis of Variance↗

A comparison of the wear and debris generation of GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) ultra high molecular weight polyethylene.

The wear debris generated from UHMWPE (ultra high molecular weight polyethylene) has been recognised as one of the major causes of failure in THR (total hip replacement). GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) which are currently the most frequently used materials in THR were studied in pin-on-plate wear test. The wear particles generated from this test were observed by scanning electron micrograph and analysed by image analysis. The results from this study showed that GUR 4150HP had superior wear resistance than GUR 1120 under relatively high wear factor conditions. These results also highlighted the importance of multidirectional motion and its effect on the wear rates of UHMWPE. The multidirectional motion tended to show a higher wear factor than previous studies using unidirectional motion conducted under otherwise similar conditions. The wear debris analysis conducted with the wear particles collected from unidirectional (relatively rough) pin-on-plate wear tests (GUR 1120 and GUR 4150HP) showed that the greatest number of particles had a size range of 0.1-0.5 micron followed by 0.5-1.0 micron, 1.0-5.0 microns and 5.0-10.0 microns, in both GUR 1120 and GUR 4150HP. However, comparing the masses of the wear particles, the bigger size range of greater than 10 microns, had the highest percent mass followed by 1.0-5.0 microns, 0.5-1.0 micron, 0.1-0.5 micron and 5.0-10.0 microns.

Biocompatible Materials↗

The influence of stress conditions on the wear of UHMWPE for total joint replacements.

In vitro studies of the effect of contact stress on the wear of ultra high molecular weight polyethylene (UHMWPE) in orthopaedic applications have produced contradictory results which predict both increased and decreased wear with increasing contact stress. In vivo studies of functioning hip prostheses have reported that 22 mm femoral heads generate lower linear and volumetric wear rates than 32 mm femoral heads. The effect of decreasing the head size will increase the contact stress but decrease the sliding distance per motion cycle. The present study consists of wear experiments under a range of contact stress magnitudes and application conditions in order to simulate the wear processes occurring in vivo. The results from these tests indicated that the wear factor actually decreases with increasing contact stress if the stress was not varied with time. If a time dependent or spatially varying stress was applied, the wear factor can increase greatly when compared to similar magnitude constant contact stress. This effect may be due to the complex relationship between the rate of wear particle generation and the rate at which the particles are released from the interface. The results of these wear experiments are discussed in terms of the influence of the stress conditions upon potential wear processes in total hip and knee prostheses.

Journal Article↗