PubMed Health⌕ Search

Biomedical subjects

P S Peigh

Publications and source records attributed to P S Peigh.

At least 19 recordsLinked to original sources

Valve replacement in the small aortic annulus: prospective randomized trial of St. Jude with Medtronic Hall.

OBJECTIVE: The ideal prosthesis for aortic valve replacement in patients with small annuli remains controversial and has yet to be identified. The purpose of this report is to compare the St. Jude (SJ) Medical and Medtronic Hall (MH) valves for aortic valve replacement in the small aortic root. METHODS: From 1986 to 1994 we prospectively randomized 456 patients to receive either the SJ or the MH valve. From this population, 80 patients (SJ, 42 patients; MH 38 patients) had a 19 or 21 mm aortic prosthesis inserted without annulus enlarging procedure. RESULTS: Follow-up was complete in all 80 patients for 270 patient years (mean 40.5 months). Analysis showed that the SJ and MH groups were similar with respect to age, gender, body surface area, valve area, NYHA class, ventricular function, prosthesis size, frequency of revascularization, bypass and global ischemic time. There were two operative deaths (1 SJ, 1 MH). Clinical performance and Dobutamine stress transesophageal doppler echocardiography could not demonstrate a significant advantage of one prosthesis over the other in this population. The change in aortic valve gradient, and left ventricular mass index measured preoperatively and within 12 months postoperatively were not different in both cohorts. CONCLUSION: The study could not detect a difference in the performance of the SJ and MH heart valves for aortic valve replacement in patients with small aortic annuli.

Adult↗

Management of asymptomatic mild aortic stenosis during coronary artery operations.

BACKGROUND: Management of asymptomatic mild aortic stenosis at the time of coronary artery bypass grafting (CABG) remains controversial. We have retrospectively analyzed a cohort of patients requiring aortic valve replacement (AVR) subsequent to CABG and compared their operative morbidity and mortality with that of a group receiving CABG and AVR simultaneously at the first operation. METHODS: Analysis is drawn from 28 patients who required AVR 8 +/- 4 years subsequent to CABG (group A) and 175 patients receiving AVR along with CABG at the primary operation (group B). Groups were similar with respect to age, sex, risk factors for cardiac disease, extent of coronary artery disease, left ventricular function, New York Heart Association class, aortic valve area, number of grafts, and size of prosthesis inserted. RESULTS: Patients having AVR subsequent to CABG had a significantly prolonged aortic cross-clamp time and global myocardial ischemic time and incurred a twofold increase in operative mortality. The actuarial survival at 10 years was not significantly different between cohorts. In the 28 patients in group A, the aortic valve area during the period between operations decreased 0.05 mm2/y. CONCLUSIONS: The operative mortality and morbidity of a second operation for AVR is high, but there is no significant difference in survival at 10 years. In at least a portion of patients having mild aortic stenosis at the time of CABG there will be progression of the stenosis necessitating reoperation at a later date.

Actuarial Analysis↗

Effect of advancing age on cost and outcome of coronary artery bypass grafting.

The clinical and billing records of 250 patients (173 men and 77 women) undergoing isolated coronary artery bypass grafting between 1987 and mid-1990 were retrospectively reviewed to determine charges and clinical results as related to age. Patients were stratified by age into five groups of 50 consecutive patients each: group 1, less than 50 years of age; group 2, 50 to 59 years; group 3, 60 to 69 years; group 4, 70 to 79 years; and group 5, 80 years or older. The groups were compared in regard to perioperative clinical variables, long-term follow-up, and total charges. Group 5 had significantly more postoperative complications than the other four groups (p < 0.05). In addition, length of postoperative hospitalization was significantly longer in group 5 compared with groups 1, 2, and 3 (p < 0.05), and operative mortality in group 5 (20%) was significantly higher than that in the other four groups. The mean total charges for group 5 were $73,399, which was significantly higher than the totals in the other four groups (p < 0.05). Actuarial 3-year survival for the hospital survivors was 87%, 89%, 78%, 82%, and 60% for groups 1, 2, 3, 4, and 5, respectively (p < 0.001). Postoperative performance as measured by the Karnofsky scale was significantly lower in group 5 than in groups 1 and 2 (p < 0.05). These data support the premise that elderly patients undergoing coronary artery bypass grafting have more complications, longer hospitalizations, and higher operative mortality than younger patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Eight years' experience with bridging to cardiac transplantation.

Although bridging to cardiac transplantation has become a therapeutic option for transplant candidates whose condition deteriorates while they are awaiting a donor heart, short-term efficacy has not been proved and long-term survival has not been reported. We retrospectively reviewed data on 44 patients who had circulatory assist devices placed as a bridge to transplantation between May 1985 and April 1993. The 35 male and nine female patients ranged in age from 12 to 65 years (mean 43.8 years). Thirty-one patients were supported with 32 Thoratec (18 left ventricular, 14 biventricular), 11 Novacor, and two Jarvik J-7-70 devices. The duration of device support was from 4 hours to 440 days (mean 45.5 days). Fifteen patients did not receive a donor organ because of infection (ten patients), renal failure (five patients), bleeding (nine patients), cerebrovascular accident (three patients), ventricular fibrillation (one patient), and right heart failure (one patient), and all died. Two patients were weaned from support and survived without transplantation. Twenty-seven patients underwent transplantation, and 26 survived (96%). Overall survival was 64% (28/44). Duration of survival ranged from 2 to 96 months (mean 35 months). Among the 28 hospital survivors, there were four late deaths (all transplant recipients) at 3, 6, 14, and 68 months. Posttransplantation actuarial survivals at 1, 5, and 8 years are 88%, 83%, and 66%. Twenty-three of the 24 patients presently alive are in New York Heart Association functional class I. These data demonstrate the short- and long-term efficacy of bridging to transplantation with circulatory support devices. The excellent survival and full functional recovery of patients undergoing transplantation ensure that donor organs are not being "wasted" on the sickest patients.

Actuarial Analysis↗

Inferior epigastric artery for myocardial revascularization.

From March 1990 through January 1992, 108 patients undergoing myocardial revascularization had one (91) or both (17) inferior epigastric arteries (IEA) used for myocardial revascularization. The internal thoracic artery (ITA) was used bilaterally in 87 patients. Of the 373 distal anastomoses, 210 (56%) were with the ITA, 130 (35%) with the IEA, and 12 (3%) with the gastroepiploic artery. Nineteen patients (18%) received 21 saphenous veins. When compared with the ITA, the IEA demonstrated a longer harvest time (36.5 vs 29.6 min, P < 0.0001), a shorter usable length (11.9 cm vs 16.5 cm, P < 0.001), and similar flow (49.7 cc/min vs 48.7 cc/min, P = NS). The operative mortality was 2.8%. Two deaths resulted from low cardiac output and the one remaining death from complications of a cerebral vascular accident. The most common major complication was respiratory insufficiency, which occurred in 11 patients (12%). There were two sternal infections (2%), and two abdominal wound infections (2%), none of which were fatal. The IEA is an acceptable additional arterial conduit. It can be safely employed with one or both ITAs. Short-term and long-term patency must be established before preferential use of this conduit is advised.

Aged↗

Mitral valve replacement: randomized trial of St. Jude and Medtronic-Hall prostheses.

To better define the merits of the bileaflet and tilting-disc valves, we prospectively randomized 102 patients (mean age, 57 years; range, 11 to 85 years) to receive either the St. Jude (n = 55) or the Medtronic-Hall (n = 47) mitral valve prosthesis between September 1986 and May 1991. The two groups were not different with respect to preoperative New York Heart Association class, incidence of mitral stenosis and insufficiency, angina score, extent of coronary artery disease, ventricular function, completeness of revascularization, or cross-clamp or bypass time. The hospital mortality (14.5% versus 10.6%, St. Jude versus Medtronic-Hall) and late mortality (7.3% versus 2.1%) were not significantly different. Follow-up was complete in 84 of 89 hospital survivors (94%) with a mean of 26 months (range, 1 to 60 months). The linearized rates of valve-related events and the 3-year actuarial survival demonstrated no significant differences between both cohorts. Comparison of the clinical outcome and echocardiographic parameters obtained at the time of follow-up demonstrated no significant differences between the two prostheses. These data indicate that the Medtronic-Hall and St. Jude mitral prostheses are similar with respect to their rates of valve-related complications and hemodynamic profiles. This study suggests that there is no difference between the St. Jude and Medtronic-Hall prostheses with regard to early clinical performance or hemodynamic results and therefore does not support the preferential selection of either prosthesis.

Adolescent↗

Intraaortic balloon pumping in patients requiring cardiac operations. Risk analysis and long-term follow-up.

The intraaortic balloon pump is usually the first mechanical device inserted for perioperative cardiac failure; however, little current information is available regarding short- and long-term effectiveness. From January 1983 through November 1990, 6856 adult patients underwent cardiac surgical procedures, 580 of whom (8.5%) had an intraaortic balloon inserted preoperatively (107 patients), intraoperatively (419 patients), or postoperatively (54 patients). There were 374 men and 206 women with a mean age of 63.9 years (range 19 to 88). Operations included 376 coronary artery bypass grafts, 100 mitral valve replacements (with or without bypass grafting), 70 aortic valve replacements (with or without bypass grafting), 15 double valve replacements (with or without bypass grafting), and 32 other procedures. There were 72 (12.4%) complications related to the balloon pump, of which 42 necessitated surgical intervention including thrombectomy (21), vascular repair (13), fasciotomy (2), aortic repair (1), and amputation (4). Operative mortality for patients supported by the balloon pump was 44%. Multivariate stepwise analysis of 27 parameters revealed six independent predictors of mortality: preoperative New York Heart Association class, transthoracic intraaortic balloon insertion (both p < 0.0001), preoperative administration of intravenous nitroglycerin, age, female gender, and preoperative balloon insertion (p < 0.001). Balloon-related complications were not predictive of death. Of the 326 hospital survivors, only 34 were lost to follow-up. There were 75 late deaths, the cause of which was cardiac in 41 (55%), noncardiac in 20 (27%), and unknown in 14 (19%). Actuarial survivals at 1, 5, and 9 years are 51%, 42%, and 33%. Of the 217 hospital survivors still alive and contacted, 81% were in class I (114) or II (60). These data demonstrate (1) operative mortality for patients requiring an intraaortic balloon in the perioperative period remains high, (2) perioperative risk factors can be identified, (3) complications related to the balloon pump do not affect survival, (4) operative survivors can achieve prolonged survival with excellent functional results, and (5) consideration for alternative methods of circulatory support is justified.

Actuarial Analysis↗

Pulmonary artery balloon counterpulsation for intraoperative right ventricular failure.

Two cases of severe low cardiac output and right ventricular failure after coronary artery bypass grafting necessitated pulmonary artery balloon counterpulsation after intraaortic balloon pumping and maximal inotropic/pressor support were unsuccessful in maintaining a satisfactory cardiac output. Hemodynamic improvement was sufficient to allow removal of the device 2 and 3 days postoperatively, with survival in 1 patient. Pulmonary artery counterpulsation is less morbid in comparison with other mechanical methods of right ventricular support and is applicable in right ventricular failure of intermediate severity.

Aged↗

Coronary bypass grafting with totally calcified or acutely dissected ascending aorta.

From August 1984 through November 1988, 10 of 2,658 patients undergoing coronary artery bypass grafting had ascending aortic disease that was not amenable to proximal anastomoses for coronary bypass grafting. This was due to a calcified aorta in 6 and acute aortic dissection in 4. There were 5 male and 5 female patients with a mean age of 71 years. Cannulation site was the femoral artery in 5, ascending aorta in 3, and aortic arch in 2. Profound hypothermia and ventricular fibrillation, with no cross-clamp or cardioplegia, was used in 9 patients, and circulatory arrest in 1. In 8 patients a single internal mammary artery was used as the total inflow with a saphenous vein graft brought off the internal mammary artery to one or more distal left-sided coronary vessels. Bilateral internal mammary arteries were used in 2 other patients. Operative mortality was zero. There was one perioperative myocardial infarction and one transient stroke without sequelae. All patients have done well from 1 to 6 years postoperatively. These data support the use of internal mammary arteries as single or bilateral proximal conduits for other venoarterial bypass grafts when the aorta is extensively diseased either by calcification or dissection.

Aged↗

Load dependence of the effective regurgitant orifice area in a sheep model of aortic regurgitation.

Treatment of patients with aortic regurgitation with vasodilators reduces regurgitant volume, ventricular dilation and left ventricular mass. Although these effects are presumably due to afterload reduction, it is also possible that the aortic regurgitant orifice area is not constant. To test the latter hypothesis, aortic regurgitation was created in 10 open chest sheep by partial resection of the noncoronary leaflet under direct visualization. Regurgitant flow was measured with an aortic supravalvular electromagnetic probe; aortic and left ventricular pressures were measured with catheter-tipped micromanometer pressure transducers. The effective regurgitant orifice area was calculated by a modification of the continuity equation in a manner similar to the Gorlin equation. The regurgitant orifice area was measured three times: after aortic regurgitation was created, after mean arterial pressure was increased by 15 to 25 mm Hg with intravenous dopamine and after mean arterial pressure was reduced by 15 to 25 mm Hg with intravenous sodium nitroprusside. Comparison of regurgitant volumes and areas obtained after creation of aortic regurgitation and at the conclusion of the experiment in the absence of dopamine or sodium nitroprusside demonstrated no significant change over time. Dopamine administration was associated with an 86 +/- 81% increase in regurgitant volume (p less than 0.01) and a 38 +/- 44% increase in regurgitant orifice area (p less than 0.01). Sodium nitroprusside administration resulted in a 51 +/- 14% decrease in regurgitant volume (p less than 0.001) and a 28 +/- 21% reduction in regurgitant orifice area (p = 0.007). In this model of acute aortic regurgitation, the effective regurgitant orifice area was altered by increasing or decreasing the aortic transvalvular pressure gradient.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Fifteen-year follow-up for double internal thoracic artery grafts.

The internal mammary artery (IMA) is the conduit of choice for myocardial revascularization. From 1972 to 1989, 586 patients received bilateral IMA and supplemental vein grafts. There were 506 men (86%) and 79 women (14%) with a mean age of 55.5 years (range 32-77 years). Unstable angina was present in 138 patients (24%), insulin-requiring diabetes mellitus in 83 (14%) and previous myocardial infarction (MI) in 25 (4%). Preoperative angiography demonstrated triple-vessel disease in 286 patients (49%) and double-vessel disease in the remaining 300 patients (51%). Left main coronary artery disease (stenosis greater than or equal to 50%) was present in 53 (9%). The mean left ventricular score was 7.4 with a range of 5 to 20. The mean number of grafts performed was 3.4 per patient. Hospital mortality was 3.6% (21 patients). Follow-up was done through direct patient contact, via the patient's physician or by telephone contact with the patient themselves or surviving family members. Follow-up was complete in 518 hospital survivors and ranged from 1 month to 17.5 years with a cumulative follow-up of 911 patient years. At 10 and 15 years, respectively, the actuarial freedom from MI was 78% and 72% and freedom from reoperation was 93% and 86%. Actuarial survival at 10 and 15 years was 85% and 70%, respectively. This longitudinal analysis demonstrates that bilateral IMA grafting has a low operative risk. The data suggest that utilization of two IMA grafts yield excellent freedom from recurrent symptoms and provides excellent long-term survival.

Actuarial Analysis↗

Neurological and ophthalmological phenomena after aortic conduit surgery.

Transient neurological and visual signs have been observed in some patients after valved conduit replacement of the aortic valve and ascending aorta. Twenty-seven patients having valved conduit replacement between February 1982 and October 1988 were compared with 21 patients having combined aortic valve replacement (AVR) and ascending aorta (AA) graft replacement. Follow-up in 100% of both groups was obtained for 0.3-6.6 years (mean, 2.6 +/- 0.3 years). Among 20 surviving valved conduit patients, 10 (50.0%) experienced repetitive neurological and visual signs, including scotomata (seven), transient motor ischemic attacks (two), amaurosis fugax (four), and recurring attention lapses suggesting petit mal seizures (one). No patient with AVR + AA graft experienced any events (p = 0.004). All valved conduit and seven (53.8%) of AVR + AA graft patients were on warfarin (p = 0.0016). These events retained the same pattern although they diminished in frequency after 12 months in seven patients (70.0%) and after initiation of dipyridamole in two patients. Rehabilitation was similar in both groups: 18 of 20 (90.0%) valved conduit and 12 of 16 (75.0%) AVR + AA graft patients (p = NS). Transient, repetitive, nonprogressive neurological and ophthalmological phenomena are frequent after valved conduit replacement. The pathophysiological mechanism is unclear, but antiplatelet therapy may provide symptomatic control.

Aorta↗

Favorable results of coronary artery bypass grafting in patients older than 75 years.

There is controversy whether the short-term and long-term results of coronary artery bypass grafting in elderly patients justify performing the procedure. Between January 1977 and December 1986, 4580 patients underwent coronary artery bypass grafting, of whom 222 (4.9%) were 75 years old or older (mean 77 years). There were 143 men and 79 women and 139 (63%) were in New York Heart Association class IV. One hundred forty-six patients (66%) had had at least one preoperative myocardial infarction. Myocardial revascularization was performed under emergency conditions in 17 patients (18%). The mammary artery was used in 43%, 96% of the patients received two or more grafts. The mean number of bypass grafts was 3.1 per patient. The overall hospital mortality rate was 10.8% (24/222), 3.6% for elective procedures, 14.9% in urgent cases, and 35% in emergencies. In contrast, the overall early mortality rate was 3.1% in 4358 patients less than 75 years old. Complications occurred in 83 patients (37%). Of the patients discharged from the hospital, 198 were followed up for a mean of 48 months (1 to 130). Actuarial probability of survival was 75% at 48 months. Postoperatively 70% were in New York Heart Association class I or II and only 21% were rehospitalized for cardiac problems. During the follow-up period 77% of the patients were free from angina, and of those experiencing angina the mean time from operation to the first episode was 75 months. Although elderly patients have a somewhat increased operative mortality rate, particularly if operated on urgently or emergently, long-term survival and freedom from angina are excellent and justify continued performance of coronary bypass grafting in selected patients over 75 years of age.

Actuarial Analysis↗

Right thoracotomy, femorofemoral bypass, and deep hypothermia for re-replacement of the mitral valve.

Ten patients underwent mitral valve re-replacement for the third to sixth time through a right thoracotomy using one-lung anesthesia, femorofemoral bypass, profound systemic hypothermia, and low-flow perfusion without aortic cross-clamping or cardioplegia. The indications for this approach were previous mediastinitis, severe right ventricular hypertension with multiple previous sternotomies, intact coronary artery bypass graft, or previous aortic valve replacement. There was 1 operative death, which was due to end-stage pulmonary hypertension and intractable right heart failure. Blood loss was minimal, and there was no major postoperative morbidity in the 9 surviving patients except for supraventricular arrhythmias.

Adult↗

Fifteen-year experience with 1678 Hancock porcine bioprosthetic heart valve replacements.

The Hancock porcine valve was the first commercially available biologic heart valve and has been in continuous use at the Brigham and Women's Hospital since January 1972. Through December 1987 we implanted 1678 valves in 1533 patients (885 male; 648 female; 17 to 95 years of age, with a mean of 60 years). There were 825 aortic valve replacements (AVR), 562 isolated mitral valve replacements (MVR), and 146 aortic mitral replacements (DVR). Ninety-four per cent of the patients were functional class III or IV. Associated coronary bypass was done in 25% of patients. Four per cent of patients were lost to follow up during a 1- to 16-year period with a mean of 6 years. Morbidity and mortality rates on a actuarial basis were calculated 10 and 15 years after operation for AVR, MVR, and DVR. The data indicates that the probability of reoperation for structural valve failure is quite reasonable as of 10 years, but from 10 to 15 years the numbers sharply fall off so that the probable effective life of the valve is 10 years. However in the elderly age group (equal to or greater than 70 years of age) the incidence of structural valve degeneration is markedly diminished, making this an ideal valve substitute for the elderly. It is also an ideal valve substitute in any patient who has a contraindication to long-term anticoagulation because of current medical or surgical problems.

Adolescent↗

Mitral valve repair for myxomatous degeneration and prolapse of the mitral valve.

From 1984 to 1988, 129 mitral valve reconstructions were done for primary pure mitral regurgitation. Sixty-two (48%) were done for myxomatous degeneration and prolapse of the mitral valve. Anterior leaflet resection was performed in seven patients, posterior leaflet resection in 46, anteroposterior resection in four; five patients received only a ring annuloplasty. Eight patients had coronary bypass grafts. Twenty-four patients received a Carpentier-Edwards annuloplasty ring, 24 a Duran ring, and 14 patients had no ring. Follow-up was 1 to 50 months (mean, 13 months). No patient was lost to follow-up. There was one operative death from gastrointestinal bleeding and two late deaths (one from suicide and one from a myocardial infarction), and the probability of survival at 48 months was 84% +/- 15%. There were no thromboembolic episodes or episodes of endocarditis. However, there were five reoperations (9%) with freedom from reoperation at 48 months of 85% +/- 5%. There was one major anticoagulant hemorrhage. Freedom from all morbidity at 48 months was 81% +/- 8%. Postoperative echocardiographic data in the three different groups of patients undergoing repair on the basis of annuloplasty treatment showed that the peak gradient was less and the valve area was slightly greater with no annuloplasty ring.

Adult↗