Dosimetric aspects of physical and dynamic wedge of Clinac 2100C linear accelerator.

AIM: To investigate variation of wedge factors on field size and depth for physical and dynamic wedges of identical wedge angles for Clinac 2100C linear accelerator and its clinical implementation. MATERIAL AND METHODS: A computer controlled water phantom dosimetric system is used to generate profile data for physical wedges, whereas a 0.6 cm3 ion chamber is used for generation of profiles for dynamic wedge and wedge factors for both types of wedges. The method has been discussed to handle the dynamic wedge dosimetry in absence of linear array of detectors or film densitometer. RESULTS: A systematic dependence on wedge factor is observed for physical wedge, with respect to depth and wedge angle but not depending on field size. Whereas dynamic wedge shows strong dependence on field size and is not systematic because the dynamic wedge is controlled by segmented treatment tables depending on field size and energy and no significant variation is observed on depth for various wedge angles. The handling of beam data in a commercially available treatment planning system is discussed and a comparison has been made for iso-doses of both types of wedges. CONCLUSION: The dynamic wedge isodose curves shows rather straight lines than physical wedge but larger hot spots at thin edge which needs careful consideration during planning.

Humans↗

Dosimetry of intracavitary applications in carcinoma of the cervix: rectal dose analysis.

The International Commission on Radiation Units and Measurements (ICRU), in its Report-38, has given certain recommendations regarding the specifications of bladder and rectal reference points in the intracavitary treatment of carcinoma of the cervix. Conforming to this report, 182 intracavitary applications performed in stage I and II cervix cases were analyzed. In 113 applications, the maximum rectal dose was found to be in a point on the anteroposterior line drawn through the centre of colpostat sources. However, for our type of applications, the point on the anteroposterior line drawn through the lower end of the uterine tube seldom gets maximum dose. In addition, it was observed that there are other dose points than the ICRU reference point receiving doses close to maximum dose. It was concluded that doses to multiple rectal reference points should be recorded, in addition to the ICRU-defined rectal reference point.

Brachytherapy↗

Geometrical considerations in dose volume analysis in intracavitary treatment.

PURPOSE: The present work was aimed at to study the relationship between the volume enclosed by reference isodose surface and various geometrical parameters of the intracavitary applicator in treatment of carcinoma of cervix. MATERIAL AND METHODS: Pearshape volume of the reference isodose derived from the Total Reference Air Kerma (TRAK) and the product of its dimensions, height H, width W and thickness T which is dependent on the applicator geometry, were estimated for 100 intracavitary applications treated by Selectron LDR machine. Orthogonal radiographs taken for each patient were used for measurement of actual geometric dimensions of the applicator and carrying out the dosimetry on TP-11 treatment planning system. The dimensions H, W and T of reference isodose surface (60 Gy) were also noted. RESULTS: Ratio of the product HWT and the pearshape volume was found mainly to be a function of colpostat separation and not of other geometrical parameters like maximum vertical and anterio-posterior dimension of the applicator. The ratio remained almost constant for a particular combination of uterine tandem and colpostat. Variation in the ratios were attributed to the non-standard geometry. CONCLUSION: The ratio of the volume of reference isodose surface to the product of its dimensions in the applicator depends upon the colpostat separation.

Brachytherapy↗

The dependency of wedge factors on field size and depth in megavoltage beams.

AIM: To investigate the variation of wedge factors on field size, depth on 2 types of telecobalt units and 3 types of medical linear accelerators and to make a simplified approach for day to day calculation procedure. MATERIALS AND METHODS: A 0.125 cm3 ion chamber was used to determine the wedge factors which is connected to the computer controlled radiation field analyser. The wedge factors were determined for field sizes varying from 5 x 5 cm to the maximum square field size available for each wedge angles and at multiple depths upto 25 cm of respective teletherapy units. The results obtained are fitted to a second degree polynomial function. RESULTS: There is no significant variation of wedge factor on field size for all the 3 linear accelerators. The wedge factors are found to vary mainly at larger depths and wedge angles. The variation of wedge factors for 2 types of cobalt units were similar and increase of 3%, 4% and 5.5% is observed for wedge angles 30 degrees, 45 degrees and 60 degrees respectively with respect of depth of maximum build-up. The trend was similar for linear accelerators with maximum increase in wedge factor up to 7.5% for 60 degrees wedge angle at 25 cm depth for 6 MV photon beams. DISCUSSION AND CONCLUSIONS: The determination of wedge factors at various field sizes and depths is essential to ensure accurate dose delivery. With experimental wedge data fitted with second degree polynomial function is a simplified and alternative method which can be adopted for routine dosimetric calculations.

Cobalt Radioisotopes↗

Design and comparison of wedge shaped midline block with rectangular block used in early stage cervical cancers.

PURPOSE: Design of an universal wedge shaped midline block for early stage cervical cancers to get uniform dose distribution around the target volume. MATERIAL AND METHODS: The method of fabrication of wedge shaped midline block is discussed for treatment of early stage cervical cancers based on the configuration of 137Cs pellets used in intracavitary applications and along with external photon beams obtained by using 60Co teletherapy machine and 6 and 10 MV linear accelerators. RESULTS: The dosimetric measurements are carried out to confirm the adequacy of thickness and shape of the block using radiation field analyzer for all the 3 energies. DISCUSSION: The dose distribution comparison has been made with wedge shaped midline block and conventional rectangular shields to show its superiority in getting homogeneous dose distribution around target volume. The shift in 184 intracavitary applications is analyzed in actual clinical applications with respect to central axis of external beams and its comparison is made with both types of blocks. With the shift of 1 cm towards lateral from midline an overdose can occur upto 12 Gy at certain points with rectangular block compared to wedge shaped midline block. CONCLUSION: Since the preparation of individual wedge shaped midline block for every application will be a difficult process for busy centers, the single wedge shaped midline block for each energy is more convenient to handle for busy centers instead of individualized compensating blocks for every intracavitary application.

Brachytherapy↗

A concave tray with divergent block for desired dose distribution around shielded region in megavoltage radiation therapy.

In clinical situations large numbers of rectangular divergent blocks are required at different off-axis positions from central axis to shield sensitive organs. Superiority of divergent blocks over non-divergent blocks on a flat tray lies in improving the dose homogeneity. A method has been developed to minimize the number of divergent shielding blocks by using a concave tray at the collimator. The results of use of a single divergent block are similar to that of the use of several divergent blocks, each to match at different off-axis positions in the radiation beam. This type of single concave tray thus provides a considerable ease of handling divergent blocks in a busy radiotherapy centre.

Bismuth↗

Treatment volume from total reference air kerma (TRAK) in intracavitory applications and its comparison with ICRU reference volume.

PURPOSE: A systematic dosimetry study conforming to International Commission on Radiation Units and Measurements Report Number 38, was carried out for, cancer of Cervix Stage I and II cases at Tata Memorial Hospital. METHODS AND MATERIALS: The reference Volume dimension were noted for each applicator. Also 3-D dosimetry was performed for selected cases, and actual geometric volume enclosed by various isodose surfaces were obtained. A relation was derived, which gave the volume enclosed by any isodose surface as a function of total reference air kerma of the sources in the applicator. The volume enclosed by reference isodose surface was compared with the product of its dimensions height, width, and thickness. RESULTS: The volume enclosed by any isodose surface of an intracavitary application can be easily derived from total reference air kerma of the sources within the applicator. CONCLUSION: Ratio of the volume enclosed by reference isodose surface with the product of its dimensions (HWT) could be a predictive parameter for clinical outcome, besides the reference volume specified by the report.

Brachytherapy↗

Alpha/beta value and importance of dose per fraction for the late rectal and recto-sigmoid complications.

A total of 203 patients with cancer of cervix stage IIIB, treated by radiation alone were analysed retrospectively for the incidence of late rectal and recto-sigmoid complications. The patients were treated with a combination of external irradiation and a single intracavitary insertion during January 1979 to December 1983. The external irradiation was randomised to deliver by four different fractionation regimens having dose per fraction of 2 Gy, 3 Gy, 4 Gy and 5.4 Gy. The doses for various fractionation regimens were matched using the time dose factors (TDF) model. 39 cases of late radiation induced rectal and recto-sigmoid complications were observed. The complication rate increased significantly (p < 0.05) with the size of dose per fraction. Using this clinical data an alpha/beta value of 3.87 +/- 0.74 Gy was estimated for late rectal and recto-sigmoid complications.

Adenocarcinoma↗

CT assisted computation of collimator angle and importance of off-axis planning of inclined lesions.

In the radiation treatment of inclined lesions the longitudinal axis of beam should be always parallel to the longitudinal axis of lesion in the treatment plane. Hence the choice of correct collimator angle is of prime importance in the oblique field off-axis treatment planning of inclined lesions. In this paper a graphical method is discussed to determine the collimator angles from the CT scans taken at different off-axis planes. A phantom was constructed which can simulate conditions like inclined lesion in the patient and CT scans were taken at different levels. The collimator angles estimated from CT scans are found to match with the collimator angles obtained from simulator within +/- 1 degree for various gantry angles. The method is applied to plan a case of cancer of the oesophagus (upper third), which is a typical example of inclined lesion.

Humans↗

Endobronchial brachytherapy: a preliminary experience.

Fourteen patients with malignant airway obstruction were treated with a placement of a flexible nylon catheter for low dose rate manual afterloading Iridium 192 endobronchial brachytherapy using a flexible fibreoptic bronchoscope. Eight patients had obstructive pneumonitis at initial presentation, while 6 cases were recurrences after previous external irradiation. Six evaluable patients of the former group had complete or partial reinflation of lung and were followed by external radiotherapy. Of the latter group, 3 were evaluable and had moderate to good palliation of their symptoms. No complication was observed. The technique is simple and safe with good patient compliance. Further evaluation is indicated to assess its role in the locoregional management of lung cancer.

Airway Obstruction↗

Predictive role of TDF values in late rectal recto-sigmoid complications in irradiation treatment of cervix cancer.

Radiation-induced late rectal and recto-sigmoid complications for different doses per fraction were analyzed retrospectively in 203 cases of Stage IIIB carcinoma of the uterine cervix. The patients were treated with a combination of external irradiation and a single intracavitary insertion during January 1979 to December 1983. The external irradiation was randomised to deliver by four different fractionation regimens having dose per fraction of 2 Gy, 3 Gy, 4 Gy and 5.4 Gy. The doses for various fractionations were matched with the daily regimen using the time-dose factors (TDF) model. A single intracavitary insertion delivered a dose of 22 to 24 Gy to point A using Fletcher-Suit applicator. All patients had a minimum follow-up of 30 months. Thirty nine cases of late radiation induced rectal and recto-sigmoid complications were observed. The complication rate of 8.2% for daily treatment regimen delivering 2 Gy per fraction was increased to 33.3% for once weekly treatment regimen delivering 5.4 Gy per fraction (p = 0.041). Despite similar Time-Dose Factors (TDF) values in four different treatment regimens, the complication rate increased significantly in the once weekly regimen. The analysis suggest that the Time-Dose Factors (TDF) values do not predict correctly the late normal tissue reactions for different dose fractionation schedules.

Adult↗

The severity of late rectal and recto-sigmoid complications related to fraction size in irradiation treatment of carcinoma cervix stage III B.

A retrospective analysis of late rectal and recto-sigmoid complications was carried out of the 203 patients with stage III B carcinoma of uterine cervix, treated using radiation therapy alone during January 1979 to December 1983. The patients were treated with a combination of external irradiation and single intracavitary insertion. External irradiation was randomised to one of the four different fractionation regimens having dose per fraction of 2 Gy, 3 Gy, 4 Gy and 5.4 Gy, delivering with five fractions/week, three fractions/week, two fractions/week and one fraction/week, respectively. The total doses in four different regimens were adjusted using the TDF model. There were 39 cases of late radiation induced rectal and recto-sigmoid complications. The complication rate was correlated with the dose per fraction and TDFs delivered in each regimen. The complication rate of 8.2% for 2 Gy per fraction was increased to 33.33% for 5.4 Gy per fraction. It was found that there is strong correlation (P less than 0.05) between size of dose per fraction and the risk of late complications. Present analysis shows that the empirical models as the NSD and TDF do not predict correctly, the late normal tissue damage for different dose fractionations.

Adult↗