PubMed Health⌕ Search

Biomedical subjects

P Scott Pine

Publications and source records attributed to P Scott Pine.

7 recordsLinked to original sources

Improvement in the reproducibility and accuracy of DNA microarray quantification by optimizing hybridization conditions.

BACKGROUND: DNA microarrays, which have been increasingly used to monitor mRNA transcripts at a global level, can provide detailed insight into cellular processes involved in response to drugs and toxins. This is leading to new understandings of signaling networks that operate in the cell, and the molecular basis of diseases. Custom printed oligonucleotide arrays have proven to be an effective way to facilitate the applications of DNA microarray technology. A successful microarray experiment, however, involves many steps: well-designed oligonucleotide probes, printing, RNA extraction and labeling, hybridization, and imaging. Optimization is essential to generate reliable microarray data. RESULTS: Hybridization and washing steps are crucial for a successful microarray experiment. By following the hybridization and washing conditions recommended by an oligonucleotide provider, it was found that the expression ratios were compressed greater than expected and data analysis revealed a high degree of non-specific binding. A series of experiments was conducted using rat mixed tissue RNA reference material (MTRRM) and other RNA samples to optimize the hybridization and washing conditions. The optimized hybridization and washing conditions greatly reduced the non-specific binding and improved the accuracy of spot intensity measurements. CONCLUSION: The results from the optimized hybridization and washing conditions greatly improved the reproducibility and accuracy of expression ratios. These experiments also suggested the importance of probe designs using better bioinformatics approaches and the need for common reference RNA samples for platform performance evaluation in order to fulfill the potential of DNA microarray technology.

Animals↗

Using RNA sample titrations to assess microarray platform performance and normalization techniques.

We have assessed the utility of RNA titration samples for evaluating microarray platform performance and the impact of different normalization methods on the results obtained. As part of the MicroArray Quality Control project, we investigated the performance of five commercial microarray platforms using two independent RNA samples and two titration mixtures of these samples. Focusing on 12,091 genes common across all platforms, we determined the ability of each platform to detect the correct titration response across the samples. Global deviations from the response predicted by the titration ratios were observed. These differences could be explained by variations in relative amounts of messenger RNA as a fraction of total RNA between the two independent samples. Overall, both the qualitative and quantitative correspondence across platforms was high. In summary, titration samples may be regarded as a valuable tool, not only for assessing microarray platform performance and different analysis methods, but also for determining some underlying biological features of the samples.

Algorithms↗

Workgroup report: Review of genomics data based on experience with mock submissions--view of the CDER Pharmacology Toxicology Nonclinical Pharmacogenomics Subcommittee.

Over the past few years, both the U.S. Food and Drug Administration (FDA) and the pharmaceutical industry have recognized the potential importance of pharmacogenomics and toxicogenomics to drug development. To resolve the uncertainties surrounding the use of microarray technology and the presentation of genomics data for regulatory purposes, several pharmaceutical companies and genomics technology providers have provided the FDA with reports of genomics studies that included supporting toxicology data (e.g., serum chemistry, histopathology). These studies were not associated with any active drug application and were exploratory or hypothesis generating in nature. For training purposes, these reports were reviewed by the Nonclinical Pharmacogenomics Subcommittee consisting of the Center for Drug Evaluation and Research pharmacology and toxicology researchers and reviewers. In this article, we describe some of these submissions and report on our assessment of data content, format, and quality control metrics that were useful for evaluating these nonclinical genomics submissions, specifically in relation to the proposed MIAME/MINTox (minimum information about a microarray experiment/minimum information needed for a toxicology experiment) recommendations. These genomics submissions allowed both researchers and regulators to gain experience in the process of reviewing and analyzing toxicogenomics data. The experience will allow development of recommendations for the submission and review of these data as the state of the science evolves.

Animals↗

Use of a mixed tissue RNA design for performance assessments on multiple microarray formats.

The comparability and reliability of data generated using microarray technology would be enhanced by use of a common set of standards that allow accuracy, reproducibility and dynamic range assessments on multiple formats. We designed and tested a complex biological reagent for performance measurements on three commercial oligonucleotide array formats that differ in probe design and signal measurement methodology. The reagent is a set of two mixtures with different proportions of RNA for each of four rat tissues (brain, liver, kidney and testes). The design provides four known ratio measurements of >200 reference probes, which were chosen for their tissue-selectivity, dynamic range coverage and alignment to the same exemplar transcript sequence across all three platforms. The data generated from testing three biological replicates of the reagent at eight laboratories on three array formats provides a benchmark set for both laboratory and data processing performance assessments. Close agreement with target ratios adjusted for sample complexity was achieved on all platforms and low variance was observed among platforms, replicates and sites. The mixed tissue design produces a reagent with known gene expression changes within a complex sample and can serve as a paradigm for performance standards for microarrays that target other species.

Animals↗

Determination of plasma and brain levels of isotretinoin in mice following single oral dose by high-performance liquid chromatography.

An isocratic reversed-phase high-performance liquid chromatographic method was established and validated according to FDA's Guidance for Industry, "Bioanalytical Method Validation", for the determination of isotretinoin in plasma and brain tissue from mice following single and multiple oral doses of Accutane. Plasma sample preparation included deproteination with acetonitrile-perchloric acid followed by centrifugation. Brain tissue was homogenized and extracted with acetonitrile-perchloric acid followed by centrifugation. The supernatants were analyzed by high-performance liquid chromatography (HPLC). Benz[alpha]anthrancene-7,12-dione was used as the internal standard. Chromatographic separation was achieved on a C18 column using an acetonitrile-aqueous 0.5% acetic acid (85:15, v/v) elution. The average extraction efficiency was >95% for plasma and >82% for brain. The lower limit of quantification was 30 ng/mL for plasma and was 30 ng/0.1g for brain tissue, respectively. The linear range for plasma was 30-600 ng/mL, and 15-300 ng/0.1g for brain. Maximum concentrations of isotretinoin in both plasma and brain were observed at 1h after single oral dosing (25 mg/kg). The maximum concentrations in plasma and brain were 2.36 microg/mL and 0.34 microg/g, respectively. The mean area under curve (AUC) in plasma was 6.13 microg h/mL. The mean eliminate half-life in plasma was estimated as 46 min.

Administration, Oral↗

Identification of platform-independent gene expression markers of cisplatin nephrotoxicity.

Within the International Life Sciences Institute Committee on Genomics, a working group was formed to focus on the application of microarray technology to preclinical assessments of drug-induced nephrotoxicity. As part of this effort, Sprague-Dawley rats were treated with the nephrotoxicant cisplatin at doses of 0.3-5 mg/kg over a 4- to 144-hr time course. RNA prepared from these animals was run on a variety of microarray formats at multiple sites. A set of 93 differentially expressed genes associated with cisplatin-induced renal injury was identified on the National Institute of Environmental Health Sciences (NIEHS) custom cDNA microarray platform using quadruplicate measurements of pooled animal RNA. The reproducibility of this profile of statistically significant gene changes on other platforms, in pooled and individual animal replicate samples, and in an independent study was investigated. A good correlation in response between platforms was found among the 48 genes in the NIEHS data set that could be matched to probes on the Affymetrix RGU34A array by UniGene identifier or sequence alignment. Similar results were obtained with genes that could be linked between the NIEHS and Incyte or PHASE-1 arrays. The degree of renal damage induced by cisplatin in individual animals was commensurate with the number of differentially expressed genes in this data set. These results suggest that gene profiles linked to specific types of tissue injury or mechanisms of toxicity and identified in well-performed replicated microarray experiments may be extrapolatable across platform technologies, laboratories, and in-life studies.

Animals↗

Dye bias correction in dual-labeled cDNA microarray gene expression measurements.

A significant limitation to the analytical accuracy and precision of dual-labeled spotted cDNA microarrays is the signal error due to dye bias. Transcript-dependent dye bias may be due to gene-specific differences of incorporation of two distinctly different chemical dyes and the resultant differential hybridization efficiencies of these two chemically different targets for the same probe. Several approaches were used to assess and minimize the effects of dye bias on fluorescent hybridization signals and maximize the experimental design efficiency of a cell culture experiment. Dye bias was measured at the individual transcript level within each batch of simultaneously processed arrays by replicate dual-labeled split-control sample hybridizations and accounted for a significant component of fluorescent signal differences. This transcript-dependent dye bias alone could introduce unacceptably high numbers of both false-positive and false-negative signals. We found that within a given set of concurrently processed hybridizations, the bias is remarkably consistent and therefore measurable and correctable. The additional microarrays and reagents required for paired technical replicate dye-swap corrections commonly performed to control for dye bias could be costly to end users. Incorporating split-control microarrays within a set of concurrently processed hybridizations to specifically measure dye bias can eliminate the need for technical dye swap replicates and reduce microarray and reagent costs while maintaining experimental accuracy and technical precision. These data support a practical and more efficient experimental design to measure and mathematically correct for dye bias.

Cell Culture Techniques↗