PubMed Health⌕ Search

Biomedical subjects

P Sganzerla

Publications and source records attributed to P Sganzerla.

At least 19 recordsLinked to original sources

The LAST operation is safe and effective: MIDCABG clinical and angiographic evaluation.

BACKGROUND: The aim of this study was to prospectively evaluate the angiographic results of a cohort of consecutive patients who underwent minimally invasive coronary artery revascularization. METHODS: From May 1997 to December 1998, 150 consecutive patients underwent left internal mammary artery to left anterior descending artery anastomosis through a left minithoracotomy on a beating heart in the Cardiovascular Department of Cliniche Gavazzeni, Bergamo, Italy. The mean age was 61.6 years (range, 36 to 84 years); 121 patients (81%) were men. Isolated left anterior descending artery disease was present in 74 patients. RESULTS: In-hospital patency was observed in 100% of the 149 angiographically controlled patients with no anomalies in 99.3% of the anastomoses. Anastomosis was performed on a diseased tract of the target vessel in 3 patients and a stenosis of the target vessel beyond the anastomosis was documented in 3 patients. In one case early angiographic control was not performed due to death of the patient on the 1st postoperative day. The morbidity included postoperative bleeding that required reopening (3.3%) and intraoperative myocardial infarction (2%). CONCLUSIONS: A left internal mammary artery to left anterior descending artery anastomosis on a beating heart through a left minithoracotomy is an alternative approach to myocardial revascularization. Surgical invasiveness is limited, cardiopulmonary bypass risks are avoided, and the procedure is safe and effective. In our consecutive series, postoperative angiographic controls demonstrated graft patency in all patients and very high quality anastomoses. Midterm clinical follow-up (14 months) appears favorable.

Adult↗

Italian BiodivYsio open registry (BiodivYsio PC-coated stent): study of clinical outcomes of the implant of a PC-coated coronary stent.

UNLABELLED: Rapid technological developments have made new materials available for percutaneous coronary intervention procedures. The coronary stent in particular has undergone progressive structural improvements leading to the recent availability of a third generation of stents, namely, coated stents. The rapid evolution of the stent has often made its evaluation problematical, since trials are frequently confined to small groups of patients in single centers. The purpose of this registry was to verify the safety and efficacy of the BiodivYsio stent (a stent coated with phosphorylcholine polymer) in a broad population of patients who reflect the daily reality of coronary intervention in a cardiac catheterization laboratory. METHODS AND RESULTS: The registry was designed to collect the principal angiographic and clinical data of a consecutive series of Oreal worldO patients. Patients were treated with a BiodivYsio stent (Biocompatibles, Galway, United Kingdom) in 12 centers (11 Italian and 1 Swiss) between January 1998 and January 1999. Procedural, in-hospital, 30-day and six-month follow-up data were collected. The monitoring, data entry and statistical analyses were carried out by an independent center. During the study, 218 patients were enrolled; 165 (76%) male and 53 (24%) female, with an average age of 61.6 +/- 9.4 years (range, 36Eth 84 years). A total of 258 stents were implanted in 233 lesions (1.1 stents per lesion), of which 233 (90%) were the BiodivYsio PC coated stent, the remaining 25 implants were of other stent types. The percutaneous transluminal coronary angioplasty and stenting procedure were carried out in 109 (50%) patients with unstable angina, 65 (30%) with stable angina, 29 (13%) with acute myocardial infarction, and 15 (7%) patients with silent ischemia. Procedural success was achieved in 217/218 (99.5%) patients. Optimal results were achieved in 212 (97.7%) patients. In 34 (15.6%) cases, patients were treated with periprocedural abciximab. During the hospitalization period, one (0.4%) death occurred on day 7 due to subacute occlusion of the stent, and 3 (1.4%) myocardial infarctions were reported. At 30-day follow-up, 211 (97.2%) patients were asymptomatic, as were 189 (87%) patients at clinical follow-up at 6 months. CONCLUSIONS: This study evaluated the safety and efficacy of a third-generation stent. The results demonstrate a high procedural success rate and a low incidence of major adverse cardiac events at short- and medium-term follow-up. It appears that the BiodivYsio stent should be considered safe in clinical and/or anatomical situations with a high risk of complications, confirming the hypothesis that PC may have non-thrombogenic properties. To corroborate these results, an appropriately designed study would be required to measure the stentOs efficacy in the most suitable clinical context, i.e., clinical situations that are at the highest risk of ischemic relapse.

Adult↗

Cardiogenic shock due to acute left main coronary artery occlusion: successful treatment with primary angioplasty.

A 56-year-old patient was admitted with cardiogenic shock due to an acute anterior myocardial infarction. Cardiac catheterization with coronary angiography disclosed a thrombotic occlusion of the left main coronary artery. Prompt mechanical recanalization of the infarct-related artery with multiple stent implantations associated with prolonged circulatory and respiratory supports allowed for a partial recovery of the left ventricular function and the discharge of the patient.

Angioplasty, Balloon, Coronary↗

[The early angiographic follow-up of myocardial revascularization in a minithoracotomy: the results of the first 100 consecutive cases].

The use of the left internal thoracic artery anastomized to the left anterior descending coronary artery via a small left thoracotomy to revascularize the anterior wall of the left ventricle has gained wide acceptance since its introduction into clinical practice a few years ago. A mandatory, postoperative angiographic control was suggested in order to check the surgical results of this new method of revascularization. We herein analyze the results of the in-hospital angiographic control of a series of 100 consecutive patients who underwent minimally invasive coronary artery bypass. In all 100 patients the thoracic graft, the anastomosis and the target vessel were patent, with no anomalies in 90 subjects. In 4 patients, a sharp angulation of the thoracic artery in the last third before the anastomosis to the native vessel was observed; in 3 subjects, the arterial graft had been anastomized to a diseased tract of the target vessel and in 3 cases a significant stenosis of the target vessel beyond the anastomosis was documented; in 2 cases the persistence of a thoracic artery branch was discovered. Since 1) neither in-hospital total occlusion of the thoracic graft to the left anterior descending coronary artery via a small thoracotomy was documented nor a significant incidence of major anomalies was observed; 2) the anomalies documented seem to be clinically negligible and may regress in the midterm postoperative period; 3) Doppler flow analysis is able to detect not only the patency but also the presence of significant stenosis in the arterial graft; the in-hospital angiographic control of this surgical technique should be limited to patients with abnormal ultrasonic data or with reappearance of myocardial ischemia in the anterior wall of the left ventricle, thus not reducing the advantages in terms of speed and cost-control of this type of myocardial revascularization.

Aged↗

Refractory coronary artery spasm with superimposed thrombosis: successful treatment with Palmaz-Schatz stent.

Prinzmetal variant angina due to epicardial coronary artery spasm is a disease usually treated with drug therapy with successful results. A case of variant angina, refractory to conventional pharmacological treatment, and complicated by coronary artery thrombosis, was treated with percutaneous transluminal coronary angioplasty and stenting with good immediate and late clinical results.

Aged↗

Local heparin delivery prior to coronary stent implantation: acute and six-month clinical and angiographic results.

Stents increase smooth muscle cell proliferation, which may also lead to in-stent restenosis. A local delivery strategy provides higher drug concentration at the angioplasty site and may limit the proliferative response following stenting. Local heparin delivery was attempted in 35 patients following balloon angioplasty using an "over-the-balloon" style catheter (infusion sleeve). The infusion sleeve was successfully tracked and heparin was delivered in 33 (94%) patients. Heparin (1,000 IU/ml) was delivered under low (45 psi, 2 ml, n = 4), intermediate (75 psi, 4 ml, n = 11), and high (100 psi, 4 ml, n = 18) proximal infusion pressures. Stent placement was successful in all cases. Acute and in-hospital complications were a severe arterial spasm after heparin delivery, a non Q-wave myocardial infarction, and two vascular complications. Ten dissections were observed after PTCA and prior to heparin delivery. Of these dissections, 7 remained unchanged, 2 worsened, and 1 improved with local delivery. When heparin was delivered in the absence of dissection, no new dissections were observed. Of the 33 patients who received heparin, 30 (91%) had no symptoms and a negative exercise test at clinical follow-up. QCA analysis of 6-month follow-up angiograms, performed in 32 of 33 (97%) patients, demonstrated an acute gain of 1.98 +/- 0.67 mm, a late loss of 0.94 +/- 0.78 mm, a net gain of 1.04 +/- 0.78 mm, and a loss index of 0.48 +/- 0.32. Restenosis (> or = 50% stenosis) was observed in 4 of 32 (12%) patients. Local delivery of heparin via the infusion sleeve following PTCA and prior to stent deployment is feasible with an acceptable safety profile and a low clinical and angiographic restenosis rate at 6 months.

Angioplasty, Balloon, Coronary↗

Changes in right ventricular filling dynamics during left anterior descending, left circumflex and right coronary artery balloon occlusion.

AIM: Transient coronary artery occlusion during percutaneous transluminal coronary angioplasty may cause left ventricular diastolic dysfunction. The aim of this study was to evaluate the effect of left anterior descending, left circumflex and right coronary artery balloon occlusion on right ventricular diastolic function. METHODS: Thirty-five patients with single-vessel coronary artery disease and no previous myocardial infarction were selected. Left and right ventricular filling pressures were monitored by Doppler echocardiography and haemodynamic monitoring. This was performed during and immediately after 60 s of coronary balloon occlusion of the left anterior descending artery in 21 cases (Group 1), the left circumflex artery in eight cases (Group 2) and the right coronary artery in six cases (Group 3). Doppler analysis of left and right ventricular filling included peak velocity of early (PFVE) and late ventricular filling (PFVA) and PFVE to PFVA ratio (PFVE/PFVA). RESULTS: In all three groups, balloon inflation induced a significant increase in left and right filling pressures (P < 0.05). No qualitative difference in haemodynamic changes was found between groups during inflation. Significant impairment in the Doppler pattern of left and right ventricular filling occurred after 20 s of coronary occlusion: PFVE values in mitral and tricuspid valves decreased by 14% and 25% in Group 1, 13% and 25% in Group 2, and 10% and 21% in Group 3, respectively, as PFVA remained unchanged in all groups, the PFVE/PFVA ratio of mitral and tricuspid valve flows significantly decreased (Group 1: -12% and -20%, Group 2: -10% and -21%, Group 3: -14% and -21%, respectively). All parameters returned to baseline within 30 s after each balloon deflation. CONCLUSION: Our data suggest that brief episodes of acute myocardial ischaemia, such as those induced by 60 s of coronary artery occlusion during percutaneous transluminal coronary angioplasty, elicit simultaneous diastolic dysfunction of both ventricles, independent of the coronary artery involved.

Angioplasty, Balloon, Coronary↗

Reversal of heart failure with sotalol in a case of incessant supraventricular tachycardia.

Supraventricular tachycardia inducing severe left ventricular enlargement and dysfunction was treated with sotalol in a 17-year-old man, in whom radiofrequency ablation had been unsuccessful. Restoration of sinus rhythm overwhelmed the negative inotropic effect of the drug and caused full reversion to normal of the left ventricular dimensions and function.

Adolescent↗

Treatment of ostial lesions of the left anterior descending coronary artery with Palmaz-Schatz coronary stent.

We evaluated acute and long-term clinical and angiographic results of elective Palmaz-Schatz coronary stent implantation for left anterior descending coronary artery (LAD) ostial stenosis in 23 consecutive patients. Eight patients had stable angina, 14 had unstable angina, and 1 had recent myocardial infarction. Sixteen patients had single-vessel, 5 had double-vessel, and 2 had triple-vessel disease. Clinical success without major complications (death, acute myocardial infarction, emergency coronary artery bypass grafting) was obtained in all cases and technical success in 20 cases (86.9%). After stenting, minimal lumen diameter increased from 1.05 +/- 0.45 mm to 2.89 +/- 0.52 mm (p < 0.001), and percent diameter stenosis decreased from 65.49% +/- 13.36% to 2.94% +/- 19.93% (p < 0.001). One case of subacute thrombosis and no major bleeding occurred. Twenty patients were followed-up for 6 months, during which no acute cardiac event (death, acute myocardial infarction) was observed. Eighteen patients were eligible for follow-up coronary angiography; restenosis (> or = 50% diameter stenosis) was observed in 4 (22.2%). Minimal lumen diameter was 1.77 +/- 0.55 mm, percent diameter stenosis was 39.66% +/- 17.62%, late loss was 1.01 +/- 0.69 mm, net gain was 0.79 +/- 0.55 mm, and loss index (late loss/acute gain) was 0.53 +/- 0.37. This study suggests that elective Palmaz-Schatz stent implantation may be a safe and successful treatment of LAD ostial lesions and provides a large increase in lumen diameter.

Angioplasty, Balloon, Coronary↗

Contribution of PO2, P50, and Hb to changes in arteriovenous O2 content during exercise in heart failure.

Arteriovenous O2 content (a-vCO2) differences increase during exercise in normal subjects through several mechanisms including PO2, O2 pressure at which hemoglobin (Hb) is half saturated with O2 (P50), and Hb concentration changes. The present study was undertaken to evaluate how much these biochemical changes are relevant to a-vCO2 difference through exercise in patients with heart failure. Twenty-seven patients with congestive heart failure [10 patients in functional class A (peak exercise O2 uptake >20 ml x kg-1 x min-1), 9 in class B (20-15 ml x kg-1 x min-1), and 8 in class C (15-10 ml x kg-1 x min-1)] underwent a cardiopulmonary exercise test with once-per-minute simultaneous blood sampling from the pulmonary and systemic arteries for determination of Hb, PO2, PCO2, pH, O2 content (CO2), Hb saturation and lactic acid (pulmonary artery only), and calculation of P50. Analysis of data was done at six exercise stages: the first at rest, the last at peak exercise, and the second to the fifth at one-, two-, three-, and four-fifths of O2 consumption increase. a-vCO2 difference at peak exercise was 14.3 +/- 2.1, 16.9 +/- 2.4, and 14.7 +/- 2.1 (SD) ml/dl in class A, B, and C patients, respectively. The contribution of Hb, P50, and PO2 changes to the increments of a-vCO2 difference during exercise was 21, 17, and 63%, respectively; the only interclass difference observed was for P50, which plays a greater role in a-vCO2 difference in class A. Hb changes act mainly at the arterial site, whereas P50 and PO2 act at the venous site. Hb increase was constant through the test, venous P50 increase was greater above anaerobic threshold, and venous PO2 reduction was most remarkable at the onset of exercise; in class C patients, no venous PO2 change was recorded in the second half of exercise. Thus a-vCO2 difference increase during exercise is notable in patients with heart failure but unrelated to the severity of the syndrome. Hb, P50, and, to the greatest degree, PO2 changes participate in the increment of a-vCO2 difference. In class C patients, the lack of PO2 reduction in the second half of exercise suggests the achievement of a "whole body critical venous PO2."

Anaerobic Threshold↗

[Recurrent restenosis after angioplasty of anomalous right coronary artery].

An anomalous right coronary artery underwent successful percutaneous transluminal coronary angioplasty (PTCA) but exercise-induced myocardial ischemia persisted. Moreover, recurrent restenosis were angiographically documented and treated by repeat PTCA. Post-PTCA large atheroma burden not appreciable by angiography, high take-off, and tangential origin of the vessel from the aorta may be some of the mechanisms involved in myocardial ischemia persistence and restenosis of the vessel.

Angioplasty, Balloon, Coronary↗

Lung-heart interaction as a substrate for the improvement in exercise capacity after body fluid volume depletion in moderate congestive heart failure.

We investigated exercise capacity after fluid depletion in patients with moderate congestive heart failure (CHF). Twenty-one patients underwent ultrafiltration (mean volume +/- SEM: 1,770 +/- 135 ml). Echocardiography, tests of pulmonary function, and a cardiopulmonary exercise test with hemodynamic and esophageal pressure monitoring were performed before ultrafiltration and 3 months later. Tests without invasive measurements were repeated 4 and 30 days after ultrafiltration. Twenty-one control patients followed the same protocol but did not have ultrafiltration. Patients who underwent ultrafiltration and increased their oxygen consumption at peak exercise (peak VO2) by > 10% at the 3-month evaluation (group A1, n = 9) were separated from those who did not (group A2, n = 8); 3 patients did not complete the follow-up. Four days after the procedure, peak VO2 had risen from 17.3 +/- 0.8 to 19.3 +/- 0.9 ml/min/kg in group A1, and from 11.9 +/- 0.7 to 14.1 +/- 0.7 ml/min/kg in group A2 (p < 0.01). Plasma norepinephrine and pulmonary function were consistent with a greater severity of the syndrome in group A2. At 3 months in group A1, the relations of filling pressure to cardiac index of the right and left ventricles were shifted upward; the esophageal pressure swing (differences between end-expiratory and end-inspiratory pressure) for a given tidal volume was lower; the peak exercise dynamic lung compliance had increased from 0.10 +/- 0.05 to 0.14 +/- 0.03 L/mm Hg (p < 0.01). None of these changes were detected in group A2 and control patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Successful transcatheter management of Palmaz Stent embolization after superior vena cava stenting.

A 34-year-old patient with benign superior vena cava syndrome (SVCS) was treated with thrombolytic therapy, balloon angioplasty, and placement of two peripheral Palmaz stents. Embolization of one stent to the right atrium occurred 10 min after successful implantation. This serious complication was successfully managed by percutaneous transcatheter technique with retrieval from the right atrium and subsequent deployment into the right external iliac vein of the lost stent. Complete resolution of SVCS symptoms occurred within 24 hr and moderate superior vena cava restenosis was successfully dilated 8 months later. At 12-month follow-up the patient continues to be asymptomatic.

Adult↗

Prompt and safe femoral hemostasis with a collagen device after intracoronary implantation of Palmaz-Schatz stents.

We report the safety and efficacy of sealing the femoral puncture site with percutaneously applied collagen after Palmaz-Schatz stent implantation in 100 consecutive patients. Patients were anticoagulated with continuous heparin infusion, overlapping oral anticoagulants, and antiplatelet therapy by dextran, aspirin, and dipyridamole. At the time of sheath removal and collagen application, the mean activated partial thromboplastin time and prothrombin time values expressed as international normalized ratio were 3.2 +/- 2.1 and 1.6 +/- 0.7, respectively. The hemostasis time ranged from 1 to 8 minutes (mean 2.18 +/- 2.08 minutes). Only two (2%) patients had major puncture-site bleeding (not seal related in one case) that required surgery and blood transfusions. Small (< 6 cm) and medium (6 to 10 cm) hematomas observed in 12 (12%) and 2 (2%) patients, respectively, resolved spontaneously without sequelae. Local infection developed in 2 (2%) patients, who were successfully treated with antibiotics without clinical consequences. Subacute stent thrombosis was observed in only 1 (1%) patient. Repeat catheterization through the same femoral artery was performed at 6-month follow-up in 55 patients without difficulty or vascular complications. These findings suggest that percutaneous collagen application after coronary stenting is a secure method of achieving prompt and effective femoral hemostasis with a low incidence of major vascular bleeding complications despite intense anticoagulation. Stable hemostasis may allow continued full-dose anticoagulation, reducing the risk of stent subacute thrombosis.

Administration, Cutaneous↗

Usefulness of L-thyroxine to improve cardiac and exercise performance in idiopathic dilated cardiomyopathy.

The short-term effects of L-thyroxine (100 micrograms/day, 10 patients) and placebo (10 patients) on idiopathic dilated cardiomyopathy were compared. Before and at the end of the treatment, a hemodynamic study was performed in the control state and during dobutamine infusion. A cardiopulmonary exercise test was also performed with hemodynamic monitoring. An echocardiogram was recorded in the control state and during acute changes of left ventricular afterload. Plasma levels of triiodothyronine, thyroxine, thyroid-stimulating hormone and norepinephrine were measured. Placebo was ineffective. After administration of L-thyroxine all patients had normal thyroid function. The increase in left ventricular ejection fraction and the rightward shift of the slope of left ventricular ejection fraction/end-systolic stress relation (p < 0.05) indicated an improvement in the cardiac inotropic state. This proved to be independent of adrenergic influences by the unchanged beta 1 response to dobutamine. A decrease in resting systemic vascular resistances and an increase in cardiac output (p < 0.05) were also observed. Cardiopulmonary effort parameters improved (p < 0.05) without hemodynamic changes at peak exercise. It is concluded that L-thyroxine short-term administration improves cardiac and exercise performance in patients with chronic heart failure, without modifying the adrenergic support to the heart and the circulatory parameters at peak exercise.

Aged↗

Sustained improvement in functional capacity after removal of body fluid with isolated ultrafiltration in chronic cardiac insufficiency: failure of furosemide to provide the same result.

OBJECTIVES: This study was designed to investigate whether a subclinical accumulation of fluid in the lung interstitium associated with moderate congestive heart failure interferes with the patient's functional capacity, and whether furosemide treatment can promote reabsorption of the excessive fluid. BACKGROUND: In patients with moderate congestive heart failure, pulmonary overhydration may be detected by chest roentgenography even if therapy is optimized to keep the urinary output normal and to prevent weight gain and dependent edema formation. Removal of the overhydration may help define its significance. METHODS: Patients, whose regimens of digoxin, oral furosemide, and angiotensin-converting enzyme (ACE) inhibitor therapy were kept constant, were randomly allocated to receive ultrafiltration (8 cases) or an intravenous bolus of supplemental furosemide (mean dose: 248 mg; 8 cases). The amount of body fluid removed with each method approximated 1600 mL. Functional performance was assessed with cardiopulmonary exercise tests. RESULTS: Soon after fluid withdrawal by either method, the filling pressures of the two ventricles and body weight were reduced and plasma renin activity, norepinephrine, and aldosterone were augmented. After furosemide administration, hormone levels remained elevated for the next 4 days, and during this period, patients had positive water metabolism, recovery of the elevated ventricular filling pressures, and re-occurrence of lung congestion with no improvement in functional capacity. After ultrafiltration, levels of renin, norepinephrine, and aldosterone fell to below control values within the first 48 hours and water metabolism was equilibrated at a new set point (less fluid intake and diuresis without weight gain). The favorable circulatory and ventilatory adjustments consequent to the reabsorption of lung water improved the functional capacity of these patients. That may also have restored the lung's ability to clear norepinephrine, thus restraining its facilitation of renin release. The improvement continued 3 months after the procedure. CONCLUSIONS: In patients with congestive heart failure the set point of fluid balance is altered in spite of oral furosemide therapy; supplemental intravenous furosemide does not shift the set point, at least not when combined with ACE inhibition. Excessive, although asymptomatic, lung water limits the functional capacity of the patient.

Aged↗