Evaluation of the MagNA pure LC instrument for extraction of hepatitis C virus RNA for the COBAS AMPLICOR Hepatitis C Virus Test, version 2.0.

The COBAS AMPLICOR system has played a major role in the transition of molecular diagnostics from research to routine clinical laboratory use by automating the nucleic acid amplification and detection processes. However, sample preparation remains a labor-intensive portion of the procedure. In this study, we evaluated the performance of the COBAS AMPLICOR Hepatitis C Virus Test, version 2.0 (Roche Molecular Systems, Branchburg, N.J.) following manual hepatitis C virus (HCV) RNA extraction versus automated extraction with the MagNA Pure LC instrument (Roche Applied Science, Indianapolis, Ind.). Parallel replicate testing was performed with standard dilutions of 100, 75, 60, and 0 HCV IU/ml and 153 clinical specimens. An analytical sensitivity of 75 IU/ml was achieved with either the manual or the standard-volume (200 microl) automated extraction methodologies (25 of 26 [96.2%]; 95% confidence interval [95% CI], 80.4 to 99.9), whereas the clinical sensitivity and specificity were both 100% with either extraction method. A large-volume (1 ml) automated extraction method was also evaluated with standard dilutions of 40, 25, 10, and 0 IU/ml and the same 153 clinical specimens. The analytical sensitivity of the COBAS AMPLICOR assay with the large-volume extraction method was 25 HCV IU/ml (26 of 26 [100%]; 95% CI, 86.8 to 100), whereas the clinical sensitivity and specificity were both 100%. The MagNA Pure LC instrument is a versatile, labor-saving platform capable of integration with minimal modification of the existing assay procedure. The increased sensitivity of the COBAS AMPLICOR Hepatitis C Virus Test, version 2.0 performed in conjunction with large-volume HCV RNA extraction may be important in HCV diagnostic testing as new therapeutic strategies evolve.

Hepacivirus↗

Comparison of line probe assay and DNA sequencing of 5' untranslated region for genotyping hepatitis C virus: description of novel line probe patterns.

We compared a commercial line probe assay (INNO-LiPA HCV II, Innogenetics, N.V., Ghent, Belgium, distributed by Bayer Diagnostics) to an in-house 5' untranslated region direct DNA sequencing method for genotyping hepatitis C virus (HCV). Initial evaluation demonstrated that the INNO-LiPA HCV II assay and sequencing assay assigned the same genotype for 110/132 (83.3%) patient specimens (98 subtype and 12 genotype only identifications). Following the initial evaluation, the INNO-LiPA HCV II assay was used routinely to genotype HCV from patient specimens submitted to our laboratory for genotyping (n = 1,739). During this second part of the study, novel line probe patterns have been noted and interpreted using the in-house direct sequencing assay. Reactivity at bands 1, 2, 3, 4, 5 and 8 (n = 4) or 1, 2, 3, 4, 6 and 7 (n = 2) represented HCV genotype 1. Reactivity at bands 1, 2, 5 and 9 (n = 1) represented HCV genotype 2. Reactivity at bands 1, 2, 5, 9 and 16 (n = 1) represented HCV genotype 4. Reactivity at bands 1, 2, 5, 9, 10, 11 (weak band) and 12 (n = 118) most likely represented HCV genotype 2b. This information should be of use to INNO-LiPA HCV II assay users.

5' Untranslated Regions↗

A simple PDMS-based electro-fluidic interface for microchip electrophoretic separations.

High voltage electrodes for electrophoresis have been integrated into a polymer layer that can be reversibly bound to glass microchips for electrophoretic separations. By using the liquid precursor to the polymer polydimethylsiloxane (PDMS), platinum electrodes and reservoirs can be positioned prior to solidification, providing a simple and flexible method for electrode interface construction. Field strengths up to 875 V cm(-1) over an 8 cm separation channel can be applied to the system without any loss in performance of the interface. The interface can function as an electro-fluidic interface between the high voltage power supply and the separation channel and, when reversibly sealed to an etched glass plate, functions as a cover plate establishing a hybrid PDMS-glass microchip in which the electrodes are directly integrated onto the device. The versatility of this approach is not only demonstrated by separating DNA fragments in a novel buffer sieving matrix, but also with the molecular diagnostic analysis of a variety of DNA samples for Duschenne Muscular Dystrophy and cytomegalovirus (CMV) infection, using both microchip interface configurations.

Cytomegalovirus Infections↗

Multiplex LightCycler PCR assay for detection and differentiation of Bordetella pertussis and Bordetella parapertussis in nasopharyngeal specimens.

A rapid real-time multiplex PCR assay for detecting and differentiating Bordetella pertussis and Bordetella parapertussis in nasopharyngeal swabs was developed. This assay (LC-PCR-IS) targets the insertion sequences IS481 and IS1001 of B. pertussis and B. parapertussis, respectively, and is performed using the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.). The analytical sensitivity is less than one organism per reaction. Results for Bordetella culture and/or direct fluorescent antibody testing and a second LightCycler PCR assay (target, pertussis toxin gene) were compared to results of the LC-PCR-IS assay for 111 nasopharyngeal swabs submitted for pertussis testing. Of the specimens, 12 were positive (9 B. pertussis and 3 B. parapertussis) and 68 specimens were negative by all methods. Three other specimens were positive for B. pertussis by at least two of the methods (including the LC-PCR-IS assay), and another 28 specimens were positive for B. pertussis by the LC-PCR-IS assay only. No specimens were negative by the LC-PCR-IS assay and positive by the other methods. A conventional PCR method (target, IS481) was also compared to the LC-PCR-IS assay for a different group of nasopharyngeal swab specimens (n = 96): 44 specimens were positive and 41 specimens were negative for B. pertussis with both PCR methods. Nine specimens were positive for B. pertussis by the LC-PCR-IS assay and negative by the conventional PCR assay, and two specimens were positive for B. pertussis by the conventional PCR assay and negative by the LC-PCR-IS assay. Positivity of the two assays was not significantly different (P = 0.0654). The insertion sequence IS481 is also present in Bordetella holmesii; specimens containing B. holmesii may yield false-positive results. The LC-PCR-IS assay takes approximately 45 min to complete post-nucleic acid extraction, compared to 24 h for the conventional PCR assay previously used in our laboratory. The LC-PCR-IS assay is easier to perform than the conventional PCR assay, and the closed system decreases the chance of contamination. All of these characteristics represent a significant improvement in the detection of B. pertussis and B. parapertussis in nasopharyngeal specimens.

Bordetella↗

Varicella-zoster virus detection by polymerase chain reaction using bronchoalveolar lavage specimens.

We report the use of polymerase chain reaction (PCR) techniques from a bronchoalveolar lavage (BAL) specimen for the successful early diagnosis in a case of atypical but severe varicella-zoster virus (VZV) pneumonitis. Atypical presentations of disseminated VZV frequently prolong the time required for accurate diagnosis, resulting in increased morbidity, or mortality. Although further investigation is necessary to determine the sensitivity and positive predictive value of this test, PCR analysis of bronchoscopic specimens may expedite the diagnosis of disseminated VZV.

Aged↗