PubMed Health⌕ Search

Biomedical subjects

P T Charles

Publications and source records attributed to P T Charles.

6 recordsLinked to original sources

Quantitative assessment of filter-based cDNA microarrays: gene expression profiles of human T-lymphoma cell lines.

MOTIVATION: While the use of cDNA microarrays for functional genomic analysis has become commonplace, relatively little attention has been placed on false positives, i.e. the likelihood that a change in measured radioactive or fluorescence intensity may reflect a change in gene expression when, in fact, there is none. Since cDNA arrays are being increasingly used to rapidly distinguish biomarkers for disease detection and subsequent assay development (Wellman et al., Blood, 96, 398-404, 2000), the impact of false positives can be significant. For the use of this technology, it is necessary to develop quantitative criteria for reduction of false positives with radioactively-labeled cDNA arrays. RESULTS: We used a single source of RNA (HuT78 T lymphoma cells) to eliminate sample variation and quantitatively examined intensity ratios using radioactively labeled cDNA microarrays. Variation in intensity ratios was reduced by processing microarrays in side-by-side (parallel mode) rather than by using the same microarray for two hybridizations (sequential mode). Based on statistical independence, calculation of the expected number of false positives as a function of threshold showed that a detection limit of [log(2)R] >0.65 with agreement from three replicates could be used to identify up- or down-modulated genes. Using this quantitative criteria, gene expression differences between two related T lymphoma cell lines, HuT78 and H9, were identified. The relevance of these findings to the known functional differences between these cell types is discussed.

False Positive Reactions↗

Explosives detection in soil using a field-portable continuous flow immunosensor.

A field method for quantitative analysis of explosives in contaminated soil samples is described. The method is based on a displacement immunoassay performed in a commercial instrument, the FAST 2000, engineered by Research International Inc. The method can be used on-site to measure 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) within 5min. For this study, replicate analyses were performed on soil extracts prepared from each field sample as well as appropriate controls, blanks, and laboratory standards. Statistical analyses were done to assess accuracy, bias, and predictability of the method. The results demonstrated that the immunosensor could be used effectively to screen environmental samples for the presence or absence of explosives. In most samples, the method also provided quantitative values that were in good agreement with standard laboratory analyses using HPLC. A limited number of sample matrices interfered with the immunoassay and produced results that varied significantly from the laboratory data. In each case, the compounds causing the problem have been identified and efforts are being made to minimize these matrix interferences in future field evaluations.

Chromatography, High Pressure Liquid↗

Trace level detection of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) by microimmunosensor.

Reported in this paper is the development and characterization of a highly sensitive microcapillary immunosensor for the detection of the explosive, hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX). The immunosensor exploits antibodies as recognition elements for target antigens, fluorescence dye conjugates for reporter molecules and fused silica microcapillaries for its high surface-to-volume ratio. Detection of RDX with the microcapillary immunosensor requires covalent immobilization of anti-RDX antibodies on the inner core of the microcapillaries via heterobifunctional cross-linker chemistry. Subsequent saturation of all antibody binding domains follows with a synthetically prepared fluorescent analog of RDX. Displacement immunoassays were performed with the microcapillary immunosensor with the injection of unlabeled RDX at concentration levels from 1 part-per-trillion (pptr) to 1000 part-per-billion (ppb). As unlabeled RDX reaches the binding domain of the antibody, fluorescent RDX analog is displaced from the antibody, flows downstream and is measured by a spectrofluorometer. Fluorescence measurements of the displaced fluorescent RDX analog were equated to a standard calibration curve to quantify sample concentration. Complete evaluation of the RDX microcapillary immunosensor for selectivity and sensitivity was performed based on the following criteria: variable flow rates, antibody cross-reactivity, reproducibility and cross-linker (carbon spacer) comparison. Results indicate the lowest detectable limit (LDL) for RDX is 10 pptr (ng/l) with a linear dynamic range from 0.1 to 1000 ppb (ug/l).

Biosensing Techniques↗

Novel trifunctional carrier molecule for the fluorescent labeling of haptens.

We developed a novel trifunctional carrier molecule for the synthesis of hapten-fluorophore conjugates as reporter molecules in immunoassays. This carrier eliminates some of the disadvantages associated with currently used fluorophore-labeling procedures including high nonspecific binding. The backbone of the carrier consists of the 21 amino acid residues of the insulin A-chain molecule. This polypeptide provides a single site (terminal amino group) for covalent coupling of the hapten, three carboxyl groups for the attachment of fluorophores, and four sulfhydryl groups for derivatization with hydrophilic residues to compensate for the hydrophobic effect of the attached fluorophores. The sites for fluorophore attachment are 4, 17, and 21 amino acids away from the hapten attachment site. This spatial separation minimizes quenching of the fluorescence signal due to interaction of the fluorophores with each other and with the attached hapten. In this study, 2,4-dinitrophenol (DNP) was selected as model hapten, fluorescein as label, and S-sulfonate groups as hydrophilic residues. The properties of the DNP-insulin A-chain-fluorescein conjugate (DNP-Ins-Fl) were compared to those of a DNP derivative labeled with a single fluorescein moiety via a small lysine spacer (DNP-Lys-Fl). The DNP-Ins-Fl conjugate exhibited a 3-fold lower nonspecific adsorption to immobilized non-immune IgG contributing to an approximately 3-fold more efficient displacement from the binding sites of an immobilized monoclonal anti-DNP antibody by the antigen DNP-lysine. Furthermore, at equimolar concentrations the DNP-Ins-Fl generated a 2.6-fold higher fluorescent signal than DNP-Lys-Fl.(ABSTRACT TRUNCATED AT 250 WORDS)

Amino Acid Sequence↗

A continuous flow immunoassay for rapid and sensitive detection of small molecules.

An immunosensor operating in continuous flow and capable of detecting low molecular weight antigens is described. The approach differs from previously described continuous flow assays by not requiring incubation steps or the introduction of additional reagents following the loading of the sample into the system. Detection of the antigen is rapid, occurring within 3 min in the system described. The assay is based on the binding of labeled antigen to an immobilized antibody, with subsequent displacement of the labeled antigen when antigen is present in the buffer flow. Signal detection occurs downstream of the antigen recognition event. In this study, the hapten 2,4-dinitrophenol (DNP) as DNP-lysine was used as model antigen. To generate a labeled antigen, DNP was coupled to the terminal amino group of insulin A chain (tetra S-sulfonate form) which provides two tyrosine residues for the introduction of an 125I-label (DNP-Ins-125I) or three carboxyl groups for the attachment of three fluorescein residues (DNP-Ins-Fl). The radiolabeled antigen was used to establish assay conditions. Subsequently, fluorescein was substituted for the radioisotope label in order to develop an assay independent of the restrictions associated with isotopes. Using this flow immunoassay, we were able to detect DNP-lysine down to a detection limit of 143 nM (29 pmol/200 microliters) using DNP-Ins-125I or DNP-Ins-Fl as labeled antigen. The density of immobilized antibody and the flow rate were identified to be critical parameters for the sensitivity of the assay.

Animals↗

Synthesis of a fluorescent analog of polychlorinated biphenyls for use in a continuous flow immunosensor assay.

A synthetic scheme has been developed for the preparation of a dye-labeled analog of polychlorinated biphenyls. The reaction of 2,3,5-trichlorophenol with 3-bromopropylamine hydrobromide under basic conditions was used to introduce a free primary amine group into the parent compound by formation of a stable ether linkage. Reaction of this amine with the succinimidyl ester of a sulfoindocyanine dye resulted in amide bond formation to produce a fluorescently-labeled product. The dye conjugate was used to charge a column containing immobilized antibodies against polychlorinated biphenyls. Upon application of samples containing various concentrations of polychlorinated biphenyls, the fluorescent analog was displaced from the column in amounts proportional to the concentration of analyte. Concentrations of polychlorinated biphenyl as low as 1 ppm were measurable using this system.

Antibodies↗