PubMed Health⌕ Search

Biomedical subjects

P T Pisciotto

Publications and source records attributed to P T Pisciotto.

17 recordsLinked to original sources

Nationwide survey of home transfusion practices.

BACKGROUND: Limited information exists on home transfusion practices. STUDY DESIGN AND METHODS: In 1995, a survey requesting data for 1994 was sent to 1273 American Association of Blood Banks (AABB) institutional members and 113 non-AABB home health care agencies that provide out-of-hospital transfusions. RESULTS: Of 943 respondents, 102 provide blood to a home transfusion program, 37 provide blood and run a home transfusion program, and 13 run a home transfusion program only, for a total of 152 (16%) with some involvement in home blood transfusions. Most of the 50 respondents with a home transfusion program are licensed by their state and accredited by the Joint Commission on Accreditation of Healthcare Organizations. All respondents have written policies for home transfusion, and 90 percent require a signed informed-consent document before initiating transfusions in the home. Most have policies requiring that there be a second adult and a telephone in the home, that the home be deemed safe for transfusion, that the patient's physician be readily available, and that the patient have had prior transfusions. The most common component issued by the blood providers was red cells, followed by platelets. White cell-reduced components were always provided by 36 percent of respondents. The most common patient diagnosis was cancer. Home transfusions were provided primarily by registered nurses. Only 14 percent of respondents indicated that the medical director of the blood bank is responsible for approving a patient for home transfusion. A posttransfusion visit is performed by 46 percent of respondents. CONCLUSION: Although most facilities have policies for the administration of home transfusions, there remains marked heterogeneity among blood providers and transfusionists regarding home transfusion practices.

Adult↗

Hypotensive reactions: a previously uncharacterized complication of platelet transfusion?

BACKGROUND: In 1993, the American Association of Blood Banks (AABB) received reports of severe hypotensive reactions associated with platelet transfusions. The question arose as to whether these reports were indicative of a previously uncharacterized platelet transfusion reaction. STUDY DESIGN AND METHODS: To further characterize these reactions, the AABB Transfusion Practices Committee developed a series of three questionnaires. The initial questionnaire was sent to all AABB institutional members; the two subsequent questionnaires were sent to those institutions reporting severe and/or unusual platelet transfusion reactions. This report focuses on the 24 responses to the third and most detailed questionnaire, which specifically addressed reactions that were characterized by hypotension and/or unexplained respiratory failure. RESULTS: Of the 24 detailed responses received, 4 were not considered to represent unusual reactions to platelet transfusion, 3 described reactions consistent with a (presumably unrecognized) diagnosis of transfusion-related acute lung injury, and 17 described reactions that were primarily characterized by hypotension. The majority of the hypotensive reactions occurred within 1 hour of the beginning of the transfusion (88%), were associated with respiratory distress (82%), and resolved rapidly after cessation of the transfusion (82%). Eighty-eight percent of implicated components had been white cell reduced by filtration. CONCLUSION: The hypotensive platelet transfusion reactions that were described appear to represent a previously uncharacterized complication of platelet transfusion. However, the nature of the questionnaires used in this investigation does not allow the drawing of firm conclusions as to the frequency or the cause of these reactions.

Adolescent↗

The effect of solvent/detergent-treated plasma on red cells stored in vitro.

BACKGROUND: The potential use of solvent/detergent-treated plasma (S/D plasma) in transfusion practice raises concerns about the cytolytic effects that any residual solvent and detergent in the virally inactivated blood component might have on units of red cells in vitro, if the two components are mixed during preparation. STUDY DESIGN AND METHODS: S/D plasma was mixed with variously processed units of stored red cells, in vitro, to evaluate the effect the residual solvent and detergent would have on cell membrane integrity. A paired protocol design was used in which half-units of red cells were exposed to S/D plasma (test), and the matched half-units were exposed to either the supernatant additive solution from the original red cell unit or standard fresh-frozen plasma (FFP) (control). After incubation for up to 5 days, the units were evaluated for evidence of hemolysis or changes in other red cell storage assays. RESULTS: This study showed that, for fresh additive solution red cells (AS-1), the 5-day storage plasma hemoglobin levels were comparable in the red cells exposed to S/D plasma (21 mg/dL) and in the paired half-units stored in the original AS-1 supernatant (31 mg/dL) (p > 0.05). Similar findings were recorded for stored AS-1 red cells (S/D plasma; 111 mg/dL vs. AS-1 supernatant, 147 mg/dL; p > 0.05); stored CPDA-1 red cells (S/D plasma, 133 mg/dL vs. FFP, 103 mg/dL; p > 0.05); frozen red cells (S/D plasma, 28 mg/dL vs. FFP, 18 mg/dL; p > 0.017); and stored irradiated AS-1 red cells (S/D plasma, 608 mg/dL vs. AS-1 supernatant, 726 mg/dL; p > 0.05). Comparable results were found for other assays, including levels of plasma potassium, osmotic fragility, and red cell antigen titer. CONCLUSION: These data show that S/D plasma does not induce red cell lysis even after 5 days of in vitro storage. These results are consistent with previous findings by this laboratory that platelets are not harmed by storage in S/D plasma. Red cells resuspended in S/D plasma and stored for up to 5 days maintain in vitro storage characteristics that are acceptable for the use of the cells in clinical transfusion practice.

Blood Preservation↗

Prophylactic versus therapeutic platelet transfusion practices in hematology and/or oncology patients.

BACKGROUND: Platelet utilization has steadily increased throughout the past three decades. At the same time, there has been very little study of the current transfusion practices. STUDY DESIGN AND METHODS: A survey was conducted of institutional members of the American Association of Blood Banks (hospitals) that were actively involved in the care of pediatric and/or adult hematology and/or oncology patients. Inquiries were made relating to the extent of prophylactic versus therapeutic use of platelets, criteria used for prophylactic transfusion of platelets and type, and dose of platelets used. Data were analyzed according to patient age and type of hospital. RESULTS: Of 786 responding hospitals, 630 (80.2%) provided sufficient data for analysis; 126 of that 630 provided care for pediatric patients. The majority (60.9%) of responding hospitals had a minimum of four hematologists and/or oncologists. Eighty-four percent of hospitals reported transfusing some apheresis platelets. The dose of platelet concentrates most frequently used for adults ranged from 6 to 10, with pools of 10 more commonly used in community hospitals. More than 70 percent of hospitals reported transfusing platelets primarily for prophylaxis: 60 percent of hospitals set the threshold platelet count for prophylactic platelet transfusion at 20,000 per microL, with approximately 20 percent each transfusing at higher and lower levels. A platelet count of 50,000 per microL was most frequently required for performance of a minor invasive procedure. CONCLUSION: The data from this study show that the majority of institutions use prophylactic platelet transfusion in both pediatric and adult hematology and/or oncology patients. However, there is considerable variation in platelet transfusion practice.

Adult↗

Transfusion practices in human immunodeficiency virus-infected patients.

BACKGROUND: The reported immunomodulatory effects of transfusion raise concern about the potential for virus activation and tumor growth in human immunodeficiency virus (HIV)-infected patients. In the absence of "standards" of transfusion practice for such patients, a survey of transfusion policies among institutions specializing in the care of HIV-infected patients was performed to delineate current practices. STUDY DESIGN AND METHODS: A survey developed by the Transfusion Practices Committee of the American Association of Blood Banks was sent to 47 AIDS clinical trial units and 14 regional hemophilia centers in North America. RESULTS: Forty-three percent of centers completed the survey. Most centers observed more than 200 HIV-infected patients each. The key findings were that 1) 81 percent of centers used identical red cell transfusion criteria for HIV-infected and noninfected patients; 2) 52 percent used recombinant human erythropoietin as initial treatment for zidovudine-induced anemia, while 46 percent used recombinant human erythropoietin for anemia not associated with zidovudine; 3) 35 percent of centers used white cell-reduced blood components in lieu of cytomegalovirus (CMV)-seronegative components when administering transfusion(s) to CMV-seronegative patients; 4) 27 percent gamma-radiated cellular components, but no case of graft-versus-host disease had been observed; 5) > 85 percent of centers used monoclonal factor VIII for pediatric and adult hemophiliacs infected with HIV; 6) approximately one-third of centers routinely white cell-reduced cellular components; and 7) the most common reasons for white cell reduction included reduction of febrile reactions and CMV risk, reduction of platelet alloimmunization, and delay of immunomodulatory consequences of transfusion. CONCLUSION: There is marked heterogeneity in transfusion practice for HIV-infected patients. Modification of cellular components to achieve different objectives is routine in many centers.

Blood Transfusion↗

In vitro characteristics of white cell-reduced single-unit platelet concentrates stored in syringes.

BACKGROUND: Platelet concentrates (PCs) for premature infants may be subjected to filtration, centrifugation, and various storage conditions before transfusion. STUDY DESIGN AND METHODS: As there are few data on the cumulative effect of these procedures on PCs, platelet properties (including biochemical and functional in vitro assays) were evaluated after the processing of single units of PCs through a 1-unit-capacity high-efficiency white cell (WBC)-reduction filter followed by syringe storage at either 22 or 37 degrees C for 6 hours. Two- and 5-day-old PCs, volume-reduced PCs, and prestorage WBC-reduced PCs were evaluated. RESULTS: WBC filtration consistently resulted in a 3 to 4 log10 reduction in WBCs, with less than 15-percent platelet loss. No adverse effects of platelet function or evidence of increased platelet activation as determined by the percentage of P-selectin positivity were noted. A decrease in pH associated with increased lactate production and consumption of glucose was observed following syringe storage under all conditions tested. Such changes were most pronounced, however, with volume-reduced PCs stored at 37 degrees C (pH 6.31 +/- 0.15, lactate 23.0 +/- 3.06 mmol/L). All pH levels at the end of storage were above the minimum Food and Drug Administration requirement (pH 6.0). CONCLUSION: The in vitro data suggest that single units of PCs can undergo WBC filtration followed by syringe storage for up to 6 hours and still maintain acceptable storage characteristics. The practice of maintaining volume-reduced PCs in syringes for 6 hours at 37 degrees C in isolettes during transfusion should, however, be avoided.

Blood Component Removal↗

Leukocyte reduction in blood component therapy.

PURPOSE: To review methods of preventing or minimizing the adverse effects associated with the transfusion of passenger leukocytes present in cellular blood components and to define groups of patients who are at risk for adverse effects. DATA SOURCES: English-language articles on transfusion medicine. STUDY SELECTION: Original reports describing the pathogenesis of leukocyte-induced adverse effects in transfusion recipients and the influence of leukocyte-reduced blood components on these effects. DATA EXTRACTION: Evaluation of the diagnosis, transfusion history, and treatment of the study patients; the methods and results of leukocyte reduction; and specific outcomes, including development of alloimmunization to leukocytes, febrile reactions to transfusion, and platelet refractoriness. DATA SYNTHESIS: Passenger leukocytes are the chief cause of alloimmunization to human leukocyte antigen (HLA) and leukocyte-specific antigens in transfusion recipients. Alloimmunization may result in febrile transfusion reactions, platelet refractoriness, and acute lung injury. Leukocytes are also the vector for transfusion-associated cytomegalovirus infection. Technologic advances in the leukocyte reduction of cellular blood components have made it possible to reduce the number of leukocytes to fewer than 10(7) per transfusion. Findings suggest that the use of leukocyte-reduced cellular blood components may minimize or prevent recurrent febrile reactions and alloimmunization to leukocyte antigens. Cytomegalovirus may not be transmitted by blood components containing fewer than 10(7) leukocytes. CONCLUSIONS: Leukocyte reduction in red blood cell and platelet transfusions using third-generation filters is indicated for selected patients who are likely to receive long-term transfusion support, to prevent recurrent febrile reactions and to prevent or delay alloimmunization to leukocyte antigens. Leukocyte-depleted transfusions may also be indicated to delay or prevent refractoriness to platelet transfusion.

Blood Component Transfusion↗

In vitro characteristics of volume-reduced platelet concentrate stored in syringes.

For convenience, small volumes of platelet concentrate (PC) intended for neonatal patients are often dispensed in syringes. The PC, however, may remain in the syringe for up to several hours before the actual transfusion. As there are few data on the effect of such syringe storage on PCs, the in vitro syringe storage properties of small volumes of 1- and 5-day-old units, and volume-reduced units of PC were evaluated. In four separate experiments, PCs were stored in syringes in volumes of 10, 15, or 30 mL for up to 6 hours at 20 to 24 degrees C without agitation. Platelets were evaluated for pH, platelet count, and a variety of biochemical and in vitro functional assays. Results showed that even with the equivalent of a full unit of platelets stored in the syringe for up to 6 hours, the pH did not fall below 6.0. Although there was an increase in lactate production and consumption of glucose, which paralleled the decline in pH, the changes were not greater than those seen in platelets stored up to 5 days in gas-permeable blood bags. Similar results were seen for PCs stored in syringes for 6 hours at 37 degrees C. All of the pH levels recorded at the end of 6 hours of syringe storage were above the minimum required level of pH 6.0. Data from in vitro platelet assays imply that at any time during their shelf life, PCs can be stored in gas-impermeable polypropylene syringes for up to 6 hours and can maintain acceptable storage characteristics; in vivo data are needed to confirm these observations.

Blood Glucose↗

Induction of mucosal glutathione synthesis by arsenic.

In the rat, oral administration of 1 mg/kg arsenic (as As2O3) binds rapidly to mucosal glutathione such that effective glutathione concentration is reduced. In response to the binding of arsenic to glutathione, de novo synthesis of glutathione occurs in the mucosal cell, resulting in twice the normal concentrations of glutathione within 3 h. This finding may explain acquired tolerance to arsenic, as well as the protective effect of arsenic against selenium toxicity.

Animals↗

Characteristics and natural history of alloimmunization following HLA-matched leukocyte transfusion in Hunter's syndrome.

The characteristics and natural history of alloimmunization to HLA were studied in five patients with Hunter's syndrome receiving long term transfusions of leukocytes collected from human leukocyte antigen (HLA) matched donors. Patients were not given any other blood component transfusions. All patients became alloimmunized at an average interval of eight months following an average of 15 transfusions. All patients developed HLA alloantibodies to transfused cross-reactive HLA antigens. Antibodies to transfused incompatible HLA antigens also developed in all patients. Multispecific HLA antibodies in which specificity determination could not be made were also seen in four patients. In a small number of patients in this study, despite matching for the private HLA specificities, HLA alloimmunization was not prevented. In fact, broad alloimmunization was seen uniformly in our patients.

Adult↗

Therapeutic plasmapheresis in patients with renal disease.

Therapeutic plasmapheresis has been enthusiastically applied in recent years to a number of disease entities associated with renal failure. It seems reasonable to attempt removal of intravascular macroglobulins or immune complexes by this mechanism; however, multiple modalities of therapy are often employed virtually simultaneously, confounding the delineation of successful treatment. Two case reports are presented to illustrate the lack of immediate response to pheresis in patients receiving other modalities of treatment. It is clear that controlled clinical trials are needed to define better the usefulness of plasmapheresis in renal diseases.

Aged↗

Outcomes assessment of a residency program in laboratory medicine.

During a down-sizing of residency programs at a State University Medical School, hospital based residents' positions were eliminated. It was determined to find out the characteristics of the residents who graduated from the Laboratory Medicine Program, to compare women graduates with men graduates, and to compare IMGs with United States Graduates. An assessment of a 25 year program in laboratory medicine which had graduated 100 residents showed that there was no statistically significant difference by chi 2 analysis in positions (laboratory directors or staff), in certification (American Board of Pathology [and subspecialties], American Board of Medical Microbiology, American Board of Clinical Chemistry) nor in academic appointments (assistant professor to full professor) when the male graduates were compared with the female graduates or when graduates of American medical schools were compared with graduates of foreign medical schools. There were statistically significant associations by chi 2 analysis between directorship positions and board certification and between academic appointments and board certification. Of 100 graduates, there were 57 directors, 52 certified, and 41 with academic appointments. Twenty-two graduates (11 women and 11 men) attained all three.

Academic Medical Centers↗