PubMed Health⌕ Search

Biomedical subjects

P Tengvall

Publications and source records attributed to P Tengvall.

At least 19 recordsLinked to original sources

Inflammatory response to titanium surfaces with fibrinogen and catalase coatings: an in vitro study.

The aim of the present study was to evaluate the possibility to modulate the early inflammatory response in vitro by coating titanium surfaces with candidate proinflammatory (fibrinogen coated turned titanium "Fib") and antiinflammatory proteins (catalase on top of fibrinogen coated turned titanium "Cat"). Additionally, turned titanium surfaces (Ti) were used as controls. The discs were incubated with human mononuclear cells. Adhered cells were investigated with respect to number, viability, differentiation (acute marker 27E10 vs. chronic marker RM3/1), and cytokine production (TNF-alpha and IL-10), after 24 and 72 h. The results indicated that it is possible to modulate the inflammatory response with protein coatings. However, the strongest inflammatory response, indicated by increased number of adhered cells and release of pro and antiinflammatory mediators, was induced by Cat. Furthermore, the cytokine production on this surface was not sensitive to LPS stimulation. Differentiation measured as the expression of the chronic cell surface marker, dominated after 72 h for all surface modifications and Cat displayed an increased number compared to the others. A decrease in the total number of adhered cells and amounts of TNF-alpha were observed on all surfaces over time. The cell viability was, in general, high for all tested surfaces. In conclusion, the study proved it possible to influence the early inflammatory response in vitro by immobilizing protein coatings to titanium surfaces. However, the catalase surface demonstrated the strongest inflammatory response, and the possibility to selectively use the potent antiinflammatory capacity of catalase needs to be further evaluated.

Catalase↗

Surface immobilized bisphosphonate improves stainless-steel screw fixation in rats.

An increase in the mechanical fixation in bone of metallic biomaterials is considered advantageous in joint replacement and fracture surgery. Different approaches to improve fixation may be e.g. surface roughening, Ca-mineral coating or surface immobilization of growth factors or drugs. In the present work, bisphosphonate, a class of drugs that inhibit bone resorption, was immobilized onto stainless-steel screws. The screws were first roughened and coated with immobilized and cross-linked fibrinogen. Subsequently, an N-bisphosphonate, pamidronate, was immobilized onto fibrinogen, and another N-bisphosphonate, ibandronate, adsorbed on top of this. The so coated screws were inserted into the tibiae of eight male Sprague-Dawley rats. Another eight rats received screws prepared in the same way, but without the bisphosphonate coating. Pullout strength tests were performed after 2 weeks of implantation. The results showed a 28% (p=0.0009) higher pullout force and 90% increased pullout energy for the bisphosphonate coated screws, and support the idea that surface immobilized bisphosphonates can be used to improve biomaterials fixation in bone.

Adsorption↗

Penetration and loading of human serum albumin in porous silicon layers with different pore sizes and thicknesses.

Human serum albumin was adsorbed into porous silicon layers with thickness up to 3 microm and with different mean pore radius in the range 4.5-10 nm. The adsorbed amount of protein was quantified by I(125) radioactive labeling techniques and ellipsometry. The results show that albumin penetrated into the pores when the mean pore radius was larger than 5.5 nm, but could not totally occupy the available surface area when the layer thickness was larger than 1 microm. Loading of albumin both into porous layers and onto plane silicon as a function of albumin concentration was also investigated. These measurements show that loading of protein increased with protein concentration at least up to 10 mg/ml for porous silicon and up to 1 mg/ml for plane silicon. The maximum deposition into the type of porous layers used here was 28 microg/cm(2), compared to 0.36 microg/cm(2) for plane silicon.

Adsorption↗

Bone formation after 4 weeks around blood-plasma-modified titanium implants with varying surface topographies: an in vivo study.

The aim of the present study was to investigate and compare the stability and bone ingrowth capacity to screw-shaped titanium implants with five different surface treatments. The implants were: (1) standard turned with a thin blood plasma coat (TP), (2) NaOH-etched dito with pore size 0.2-0.3 microm (E), (3) NaOH-etched with pore size 0.2-0.3 microm and a thin blood plasma coat (EP), (4) electrochemically oxidised with pore size 1-2 microm (O), (5) electrochemically oxidised with pore size 1-2 microm and a thin blood plasma coat (OP). A total of 66 implants were divided into the above-described five groups and inserted for 4 weeks into tibia and femur of 11 rabbits. The implants were evaluated by resonance frequency (RF) measurements at the time of insertion and removal, and analysed histomorphometrically at removal. The RF measurements showed that the implant stability was lower in soft bone compared to dense and increased with time. No significant differences were observed between the different surface modifications. The histomorphometric analysis revealed no statistically significant differences between the implants regarding bone-to-metal contact (BMC) and bone area inside the threads (BA). The above results indicate that thin blood plasma-coated and non-coated screw-shaped titanium implants with turned, NaOH-etched and electrochemically etched surface profiles integrate similarly to bone at 1 month of implantation.

Bone Development↗

IL-1alpha, IL-1beta and TNF-alpha secretion during in vivo/ex vivo cellular interactions with titanium and copper.

Titanium (Ti) and copper (Cu) were used to evaluate cytokine secretion around materials with different chemical properties. Ti disks were coated with Cu or left uncoated. The disks were inserted subcutaneously in rats for 1, 3, 12, 18, 24 and 48 h. Interleukin-1alpha (IL-1alpha), IL-1beta and tumor necrosis factor-alpha (TNF-alpha) concentrations were measured in vivo around the materials, in sham operated sites, and after ex vivo incubation of surface adherent cells. Ti and Cu revealed distinct cytokine expression patterns. Cu recruited cells showed higher and prolonged release of IL-1alpha than Ti at longer times (>24 h), whereas Ti exhibited a transient IL-1alpha response at earlier periods (<24 h). An early enhanced secretion of TNF-alpha characterized Ti. Low amounts of IL-1beta were found around both materials. Sham site recruited cells produced lower levels of cytokines. The results after ex vivo incubations were similar to those in vivo. This study shows that material chemical properties influence early cytokine production. The Ti-associated transient rise of IL-1alpha and TNF-alpha may be of importance for the early tissue response around biocompatible materials, while a delayed high IL-1alpha expression could be a marker of inflammation induced by toxic materials.

Animals↗

Peptide functionalized poly(L-lysine)-g-poly(ethylene glycol) on titanium: resistance to protein adsorption in full heparinized human blood plasma.

The graft copolymer poly(L-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) and its RGD- and RDG-functionalized derivatives (PLL-g-PEG/PEG-peptide) were assembled from aqueous solutions on titanium (oxide) surfaces. The polymers were characterized by NMR in order to determine quantitatively the grafting ratio, g (Lys monomer units/PEG side chains), and the fraction of the PEG side chains carrying the terminal peptide group. The titanium surfaces modified with the polymeric monomolecular adlayers were exposed to full heparinized blood plasma. The adsorbed masses were measured by in situ ellipsometry. The different PLL-g-PEG-coated surfaces showed, within the detection limit of the ellipsometric technique, no statistically significant protein adsorption during exposure to plasma for 30 min at 22 degrees C or 37 degrees C, whereas clean, uncoated titanium surfaces adsorbed approximately 350 ng/cm2 of plasma proteins. The high degree of resistance of the PEGylated surface to non-specific adsorption makes peptide-modified PLL-g-PEG a useful candidate for the surface modification of biomedical devices such as implants that are capable of eliciting specific interactions with integrin-type cell receptors even in the presence of full blood plasma. The results refer to short-term blood plasma exposure that cannot be extrapolated a priori to long-term clinical performance.

Blood Proteins↗

C1q-independent activation of neutrophils by immunoglobulin M-coated surfaces.

Neutrophil granulocytes are known to rapidly adhere and undergo frustrated phagocytosis upon contact with immunoglobulin and/or complement protein opsonized artificial surfaces. In this study, we examined the relation between serum protein deposition and human neutrophil activation on hydrophobic glass and silicon model surfaces that were coated with immunoglobulin G or M (IgG/IgM), both initiators of the classical complement pathway. Protein adsorption from normal human serum (NHS) was quantified with null-ellipsometry combined with antibody techniques. The neutrophil oxygen radical production was registered by luminol-amplified chemiluminescence (CL) and the morphology, as well as changes in the content of filamentous actin (F-actin), were documented by fluorescence microscopy. Complement factor 3 (C3) bound to both IgG- and IgM-coated surfaces, but surprisingly C1q was found only on IgG-coated surfaces. Both immunoglobulins triggered complement dependent neutrophil activation. However, CL and F-actin accumulation were found sensitive to the presence of C1q in the serum only at the IgG-coated surface. We suggest that spontaneously adsorbed IgM activates the complement system and interacts with neutrophils by C1q-independent mechanisms.

Actins↗

Ellipsometric in vitro studies on the activation of complement by human immunoglobulins M and G after adsorption to methylated silicon.

Human serum immunoglobulin M (IgM) or human immunoglobulin G (IgG) were adsorbed to dichlorodimethyl silane (DDS) treated silicon. Subsequently, the model surfaces were incubated in normal-, complement factor 1q (C1q)-complement factor B or complement factor 2 (C2)-depleted human sera at 37 degrees C for up to 1.5 h. The serum deposition and binding of selected polyclonal complement antibodies into this layer were then quantified by null ellipsometry. Both types of precoated surfaces bound large amounts of anti-complement factor 3c (anti-C3c), anti-properdin and anti-C3d, after incubation in normal serum. In contrast to IgG coated surfaces, IgM coated surfaces bound no anti-C1q after the serum incubations and no anti-C3c deposition lag time was observed after incubations in EGTA serum. Upon immersions of IgM coated surfaces in the different sera, a rapid complement activation via a C1q factor B, and Ca(2+)-independent, but C2 dependent pathway, was indicated. When IgM was instead immobilized to APTES/glutaraldehyde surfaces, anti-C3c deposition was lower after incubations in EGTA than normal serum. The results suggest that, under the present experimental conditions, human IgM and IgG activate the complement system differently.

Journal Article↗

Ellipsometric in vitro studies on blood plasma and serum adsorption to zirconium.

Ellipsometry/antibody techniques were used to study the adsorption of heparinized human blood plasma and serum onto spontaneously oxidized zirconium, and a colorimetric assay measured the formation of kallikrein by the surface in citrated plasma. After 10 min incubation in the blood plasma the protein film thickness was approximately 4.2 nm, and the film bound polyclonal antibodies mainly against high molecular weight kininogen (HMWK), immunoglobulin G (IgG) and fibrinogen. After 5 or 60 min of incubations in whole normal or EGTA sera, antibodies against complement factor 3 (C3) and complement factor 3d (C3d) deposited to the surface. Factor H and complement factor 1q (C1q) were detected similarly after 1 and 5 min of incubation in 1-10% normal serum in veronal buffer, respectively. The indications are that upon contact with blood plasma, zirconium activates the intrinsic pathway of coagulation and is opsonized with C3. The failure to detect properdin and transient presence of factor H at the surface suggest that complement binds to zirconium although the activation becomes quickly down-regulated.

Adsorption↗

In vitro preparation and ellipsometric characterization of thin blood plasma clot films on silicon.

The wound-healing process around implants differs from that of a normal healing without the inserted material. In this work, the composition of a natural wound surface was mimicked through clotting of a thin human blood plasma film with approximate ellipsometric thickness of 100 nm onto differently pretreated silicon surfaces. Their stability was investigated by incubations in sodium dodecyl sulphate (SDS) solutions. The enzymatic clot degradation was induced through addition of human tissue plasminogen activator (t-PA) to the plasma and the surface protein remnants after the degradation were analyzed with polyclonal antibodies. The results show that the plasma films were not SDS resistant on hydrophilic silicon. However, stability was obtained after preparation on hydrophobic silicon or when albumin or fibrinogen was immobilized to silicon before the plasma incubations. Different surfaces bound different polyclonal antibodies after the clot film degradation. The methods indicate a simple means to improve or reestablish a normal tissue inflammatory response around biomaterials.

Blood Coagulation↗

Protein adsorption to oligo(ethylene glycol) self-assembled monolayers: experiments with fibrinogen, heparinized plasma, and serum.

Low protein adsorption is believed advantageous for blood-contacting materials and ethylene glycols (EG)-based polymeric compounds are often attached to surfaces for this purpose. In the present study, the adsorption of fibrinogen, serum, and plasma were studied by ellipsometry on a series of well-defined oligo(EG) terminated alkane-thiols self-assembled on gold. The layers were prepared with compounds of the general structure HS-(CH2)15-CONH-EGn, where n = 2, 4, and 6. Methoxy-terminated tri(EG) undecanethiol and hydroxyl-terminated hexadecanethiol self-assembled monolayers (SAMs) were used as references. The results clearly demonstrate that the adsorption depends on the experimental conditions with small amounts of fibrinogen adsorbing from a single protein solution, but larger amounts of proteins from serum and plasma. The adsorption of fibrinogen and blood plasma decreased with an increasing number of EG repeats and was temperature-dependent. Significantly less serum adsorbed to methoxy tri(EG) than to hexa(EG) and more proteins remained on the latter surface after incubation in a sodium dodecyl sulfate (SDS) solution, indicating a looser protein binding to the methoxy-terminated surface. All surfaces adsorbed complement factor 3 (C3) from serum and plasma, although no surface-mediated complement activation was observed. The present study points to the importance of a careful choice of the protein model system before general statements regarding the protein repellant properties of potential surfaces can be made.

Adsorption↗

Complement activation on immunoglobulin G-coated hydrophobic surfaces enhances the release of oxygen radicals from neutrophils through an actin-dependent mechanism.

Neutrophil granulocytes are among the first cells to encounter a plasma protein-coated implant and may through frustrated phagocytosis release toxic oxidative species. We used two model surfaces, hydrophobic and hydrophilic glass, to investigate the effects of plasma immunoglobulin G (IgG)-complement interactions for neutrophil adhesion and respiratory burst. The respiratory burst was measured with luminol-amplified chemiluminescence and cell adhesion was determined by labeling neutrophils with 2', 7'-bis-(carboxy-ethyl)-5(6)-carboxyfluorescein. We demonstrate that the IgG-triggered neutrophil adhesion and oxygen radical production is augmented in the presence of normal human serum, in particular on hydrophobic surfaces, indicating that complement factors enhance the neutrophil activation. We propose that the complement factors C3, C5a, and C1q are especially important for this amplification, but factor B is probably not. Disturbance of the actin filament dynamics with cytochalasin B or jasplakinolide blocked the neutrophil radical generation on all surfaces. However, these drugs did not affect the number of adherent neutrophils. We suggest that there is a synergistic interaction between adsorbed IgG, and the complement system, which amplifies the neutrophil acute inflammatory responses through a dynamic actin cytoskeleton on synthetic surfaces.

Actins↗

Peptide modified gold-coated polyurethanes as thrombin scavenging surfaces.

Thin layers of gold were deposited on polyurethane film and chemisorbed with three peptides having an N-terminal cysteine: Cys-Pro-Arg, Cys-(L)Phe-Pro-Arg, and Cys-(D)Phe-Pro-Arg. The ability of these surfaces to act as thrombin scavengers was evaluated. The peptides are related to the known thrombin inhibitor Phe-Pro-Arg chloromethyl ketone and were shown to have significant thrombin inhibitory activity in solution. Attachment of the peptides to gold was confirmed by water contact angle and X-ray photoelectron spectroscopy measurements. Thrombin adsorption from a buffer and plasma was investigated, and chromogenic substrate assays were carried out for thrombin activity on the surfaces and in the supernatant following adsorption. The data suggest that the peptide-modified surfaces are able to adsorb thrombin with high affinity from a buffer and that thrombin is taken up selectively from plasma. The Cys-(D)Phe-Pro-Arg modified surfaces showed particularly high affinity for thrombin. It was also found that the activity of thrombin adsorbed on the peptide surfaces was inhibited, and inhibition was greatest on the Cys-(D)Phe-Pro-Arg surface. We concluded that the peptide surfaces may have potential as antithrombogenic materials via their ability to scavenge and inhibit thrombin generated as a result of blood-material contact.

Adsorption↗

Comparison of surface plasmon resonance and quartz crystal microbalance in the study of whole blood and plasma coagulation.

The coagulation of blood plasma and whole blood was studied with a surface plasmon resonance (SPR) based device and a quartz crystal microbalance instrument with energy dissipation detection (QCM-D). The SPR and QCM-D response signals were similar in shape but differing in time scales, reflecting differences in detection mechanisms. The QCM-D response time was longer than SPR, as a physical coupling of the sample to the substrate is required for molecules to be detected by the QCM-method. Change of sample properties within the evanescent field is sufficient for detection with SPR. Both the SPR signals and the QCM-D frequency and dissipation shifts showed dependency on concentrations of coagulation activator and sensitivity to heparin additions. The ratio of dissipation to frequency shifts, commonly considered to reflect viscoelastic properties of the sample, varied with the concentration of activator in blood plasma but not in whole blood. Additions of heparin to the thromboplastin activated whole blood sample, however, made the ratio variation reoccur. Implications of these observations for the understanding of the blood coagulation processes as well as the potential of the two methods in the clinic and in research are discussed.

Animals↗

Analysis of rat plasma proteins desorbed from gold and methyl- and hydroxyl-terminated alkane thiols on gold surfaces.

It is believed that adsorbed blood or plasma components, such as water, peptides, carbohydrates and proteins, determine key events in the concomitant inflammatory tissue response close to implants. The aim of the present study was to develop a procedure for the collection and analysis of minor amounts of proteins bound to solid metal implant surfaces. The combination of a sodium dodecyl sulfate washing method coupled with a polyacylamide gel electrophoretic protein separation technique (SDS-PAGE), Western blot and image analysis enabled the desorption, identification and semiquantification of specific proteins. The analyzed proteins were albumin, immunoglobulin G, fibrinogen and fibronectin. Concentration procedures of proteins were not required with this method despite the small area of the test surfaces. The plasma proteins were adsorbed to pure gold and hydroxylated and methylated gold surfaces, which elicit different tissue responses in vivo and plasma protein adsorption patterns in vitro. The image analysis revealed that the pure gold surfaces adsorbed the largest amount of total and specific proteins. This is in accordance with previous ellipsometry/antibody experiments in vitro. Further, the principles described for the protein analysis can be applied on implant surfaces ex vivo.

Journal Article↗

Blood plasma coagulation studied by surface plasmon resonance.

A surface plasmon resonance (SPR) apparatus was used to investigate blood plasma coagulation in real time as a function of thromboplastin and heparin concentrations. The response curves were analyzed by curve fitting to a sigmoid curve equation, followed by extraction of the time constant. Clotting activation by thromboplastin resulted in increased time constant, as compared to spontaneously clotted plasma, in a dose dependent way. Addition of heparin to the thromboplastin-activated plasma counteracted this effect. Atomic force microscopy (AFM) pictures of sensor surfaces dried after completed clotting, revealed differences in fibrin network structures as a function of thromboplastin concentration, and the fiber thickness increased with decreased thromboplastin concentration. The physical reason for the SPR signal observed is ambiguous and is therefore discussed. However, the results summarized in the plots and the fibrin network properties observed by AFM correlate well with present common methods used to analyze blood coagulation.

Anticoagulants↗

Surface characterization, protein adsorption, and initial cell-surface reactions on glutathione and 3-mercapto-1,2,-propanediol immobilized to gold.

Monolayers of glutathione (GSH) and 3-mercapto-1,2-propanediol (MG) on gold were tested for their bioreactivity by assessing the degree of inflammatory reaction as manifested by the adherence and activation of platelets and white blood cells (wbc) after exposure to blood ex vivo. Surface composition was characterized by XPS, and noncontact optical profilometry was used to determine surface roughness. The thickness and composition of the adsorbed protein layers were measured by ellipsometry/antibody techniques in vitro. Cell adhesion and activation were quantified by acridine orange staining, fluorescein-diacetate staining, and by specific antibodies against cell membrane antigens. Distinct differences among the surfaces were observed relative to the amounts and composition of adsorbed plasma proteins and the adhesion and activation of platelets (CD62P-exposure) and wbc (CD11b/CD18-exposure). GSH surfaces, which adsorbed the least amount of plasma protein, caused the least adherence and activation of platelets (CD62P), followed by the highest activation of wbc (CD11b/18). The MG surfaces caused a rapid recruitment and activation of platelets (CD62P), followed by a lower activation of wbc (CD11b/18). Thus it appears that measurements of the initial adsorption of plasma protein from anticoagulated plasma and of the adhesion and activation of platelets after 8 min of exposure to whole blood cannot be used to predict accurately the adhesion and activation behavior of inflammatory cells after longer periods (2 h) of exposure on different surfaces.

Adsorption↗

Ellipsometric studies in vitro on kinetics of rat complement activation.

The role of complement activation may be important during the early interactions between implantable materials and blood and during the acute inflammatory phase, but it is not well understood. This applies especially to rats that are extensively used in in vivo animal models for materials and surface testing. Features of the kinetics of rat complement activation were studied and compared with human complement by the ellipsometry and antibody techniques. The results indicate that the rat classical pathway is rapidly activated, but it is not as fast as the human system. The activation of the alternative pathway was observed within 5 min in the rat system and within 15 min for the human. Thus, the observations indicate substantial differences in the kinetics between the two species. This may influence the choice of the rat experimental model and the tissue response to materials during in vivo conditions.

Animals↗