PubMed Health⌕ Search

Biomedical subjects

P Toy

Publications and source records attributed to P Toy.

At least 19 recordsLinked to original sources

Cloning and genetic characterization of an evolutionarily conserved human olfactory receptor that is differentially expressed across species.

We have cloned the full-length cDNA and genomic region of a human prostate specific G-protein coupled receptor with properties characteristic of an olfactory receptor. A partial cDNA sequence of this gene, called PSGR, was recently cloned. The gene contains two exons and one intron of 14.9 kb in its 5'untranslated region, and was mapped to human chromosome 11p15.2. A cluster of transcription initiation sites for the 2.8 kb PSGR mRNA was identified. Cloning of the homologous gene from the mouse revealed 93% amino acid homology between the human and mouse or rat (previously cloned as RA1c) proteins, and 99% identity between the rat and mouse homologs. Although northern analysis indicated expression of the human PSGR homolog was prostate specific, its mRNA could also be detected in the olfactory zone and the medulla oblongata of the human brain. In the mouse, the PSGR gene is predominantly expressed in the brain and colon. In the rat, the PSGR homolog is expressed in the liver in addition to the brain. These data add to the growing body of evidence suggesting that olfactory receptors may have functional roles in tissues other than the olfactory organ, and further, suggest that these functions may vary across species.

5' Flanking Region↗

Research opportunities in transfusion medicine.

In recent years, the translation of basic research in transfusion medicine has led to development of novel cellular therapies using well-characterized cell populations isolated from either bone marrow or blood (eg, hematopoietic stem and progenitor cells, T lymphocytes, dendritic cells). Refinements in cell therapies will make possible optimal stem cell engraftment, gene therapy, immunotherapy of cancer and infectious disease, and even solid organ regeneration. Moreover, the immune consequences of transfusion therapy are better appreciated and opportunities are at hand to prevent or blunt unwanted immune responses, such as platelet refractoriness and graft-vs-host disease. Transfusion medicine has become a broad, multidisciplinary field that has evolved beyond issues related to blood procurement and storage. The next series of advances in transfusion medicine will complement the current approaches of donor blood screening and viral/bacterial inactivation steps to ensure a safe and adequate blood supply.

Blood Substitutes↗

Subcutaneous perfusion and oxygen during acute severe isovolemic hemodilution in healthy volunteers.

HYPOTHESIS: Acute severe isovolemic anemia (to a hemoglobin [Hb] concentration of 50 g/L) does not decrease subcutaneous wound tissue oxygen tension (PsqO(2)). SETTING: University hospital operating room and inpatient general clinical research center ward. SUBJECTS: Twenty-five healthy, paid volunteers. METHODS: Subcutaneous oxygen tension and subcutaneous temperature (Tsq) were measured continuously during isovolemic hemodilution to an Hb level of 50 g/L. In 14 volunteers (initially well-perfused), "normal" perfusion (Tsq >34.4 degrees C) was achieved by hydration and systemic warming prior to starting isovolemic hemodilution, while in 11 volunteers (perfusion not controlled [PNC]), no attempt was made to control perfusion prior to hemodilution. MAIN OUTCOME MEASURES: Measurements of PsqO(2), Tsq, and relative subcutaneous blood flow (flow index). RESULTS: While PsqO(2), Tsq, and flow index were significantly lower in PNC vs well-perfused subjects at baseline, there was no significant difference between them at the Hb of 50 g/L (nadir). Subcutaneous PO(2) did not decrease significantly in either group. Arterial PO(2) was not different between the groups, and did not change significantly over time; Tsq and flow index increased significantly from baseline to nadir Hb in both groups. CONCLUSIONS: The level of PsqO(2) was maintained at baseline levels during hemodilution to Hb 50 g/L in healthy volunteers, whether they were initially well-perfused or mildly underperfused peripherally. Given the significant increase in Tsq and flow index, this resulted from a compensatory increase in subcutaneous blood flow sufficient to maintain oxygen delivery. Wound healing depends to a large extent on tissue oxygen delivery, and these data suggest that even severe anemia by itself would not be sufficient to impair wound healing. Thus, transfusion of autologous packed red blood cells solely to improve healing in surgical patients with no other indication for transfusion is not supported by these results.

Acute Disease↗

Fatigue during acute isovolemic anemiain healthy, resting humans.

BACKGROUND: Transfusion guidelines recommend that clinicians assess patients for signs and symptoms of anemia before the transfusion of RBCs. However, studies of signs and symptoms associated with acute isovolemic anemia are limited. The objective of this study was to determine whether acute reduction of Hb concentration to 5 g per dL would result in fatigue, tachycardia, or hypotension in resting, young, healthy, isovolemic humans, and whether changes were reversible with RBC transfusion. STUDY DESIGN AND METHODS: Conscious, resting, healthy adults less than 35 years old (n = 8) underwent acute isovolemic hemodilution to Hb of 5 g per dL and self-scored their energy level at various Hb concentrations. Heart rate and blood pressure were also measured. For controls, measurements of each subject were made during a comparable period of rest without hemodilution. RESULTS: During acute isovolemic hemodilution, energy levels decreased progressively and were lower at Hb of 7, 6, and 5 g per dL than at baseline (p<0.01) or in control sessions (p<0.05). The energy level was lower at Hb 7 g per dL than at 14 ( p = 0.005), lower at Hb 6 g per dL than at 7 (p = 0.01), and lower at Hb 5 g per dL than at 6 (p =0.01). Energy levels rose and were not different from baseline or control levels after transfusion of all autologous RBCs. Similarly, median heart rate increased with hemodilution to Hb of 7, 6, and 5 g per dL and decreased with transfusion of autologous RBCs. Supine blood pressure did not decrease with isovolemic hemodilution. CONCLUSION: In resting, young, healthy humans, acute isovolemic anemia to Hb levels of 7, 6, and 5 g per dL results in decreased self-scored energy levels and in an increase in heart rate but not in hypotension. Changes in energy and heart rate are reversible with the transfusion of autologous RBCs.

Acute Disease↗

Critical oxygen delivery in conscious humans is less than 7.3 ml O2 x kg(-1) x min(-1).

BACKGROUND: The "critical" level of oxygen delivery (DO2) is the value below which DO2 fails to satisfy the metabolic need for oxygen. No prospective data in healthy, conscious humans define this value. The authors reduced DO2 in healthy volunteers in an attempt to determine the critical DO2. METHODS: With Institutional Review Board approval and informed consent, the authors studied eight healthy, conscious volunteers, aged 19-25 yr. Hemodynamic measurements were obtained at steady state before and after profound acute isovolemic hemodilution with 5% albumin and autologous plasma, and again at the reduced hemoglobin concentration after additional reduction of DO2 by an infusion of a beta-adrenergic antagonist, esmolol. RESULTS: Reduction of hemoglobin from 12.5+/-0.8 g/dl to 4.8+/-0.2 g/dl (mean +/- SD) increased heart rate, stroke volume index, and cardiac index, and reduced DO2 (14.0+/-2.9 to 9.9+/-20 ml O2 x kg(-1) x min(-1); all P<0.001). Oxygen consumption (VO2; 3.0+/-0.5 to 3.4+/-0.6 ml O2 x kg(-1) x min(-1); P<0.05) and plasma lactate concentration (0.50+/-0.10 to 0.62+/-0.16 mM; P<0.05; n = 7) increased slightly. Esmolol decreased heart rate, stroke volume index, and cardiac index, and further decreased DO2 (to 7.3+/-1.4 ml O2 x kg(-1) x min(-1); all P<0.01 vs. before esmolol). VO2 (3.2+/-0.6 ml O2 x kg(-1) x min(-1); P>0.05) and plasma lactate (0.66+/-0.14 mM; P>0.05) did not change further. No value of plasma lactate exceeded the normal range. CONCLUSIONS: A decrease in DO2 to 7.3+/-1.4 ml O2 x kg(-1) min(-1) in resting, healthy, conscious humans does not produce evidence of inadequate systemic oxygenation. The critical DO2 in healthy, resting, conscious humans appears to be less than this value.

Adrenergic beta-Antagonists↗

Acute severe isovolemic anemia impairs cognitive function and memory in humans.

BACKGROUND: Erythrocytes are transfused to prevent or treat inadequate oxygen delivery resulting from insufficient hemoglobin concentration. Previous studies failed to find evidence of inadequate systemic oxygen delivery at a hemoglobin concentration of 5 g/dl. However, in those studies, sensitive, specific measures of critical organ function were not used. This study tested the hypothesis that acute severe decreases of hemoglobin concentration alters human cognitive function. METHODS: Nine healthy volunteers, age 29 +/- 5 yr (mean +/- SD), were tested with verbal memory and standard, computerized neuropsychologic tests before and after acute isovolemic reduction of their hemoglobin to 7, 6, and 5 g/dl and again after transfusion of their autologous erythrocytes to return their hemoglobin concentration to 7 g/dl. To control for duration of the experiment, each volunteer also completed the same tests on a separate day, without alteration of hemoglobin, at times of the day approximately equivalent to those on the experimental day. RESULTS: No test showed any change in reaction time or error rate at hemoglobin concentration of 7 g/dl compared with the data at the baseline hemoglobin concentration of 14 g/dl. Reaction time, but not error rate, for horizontal addition and digit-symbol substitution test (DSST) increased at hemoglobin 6 g/dl (mean horizontal addition, 19%; 95% confidence interval [CI], 4-34%; mean DSST, 10%; 95% CI, 4-17%) and further at 5 g/dl (mean horizontal addition, 43%; 95% CI, 6-79%; mean DSST, 18%; 95% CI, 4-31%). Immediate and delayed memory was degraded at hemoglobin 5 g/dl but not at 6 g/dl. Return of hemoglobin to 7 g/dl returned all tests to baseline, except for the DSST, which significantly improved, and returned to baseline the following morning after transfusion of all autologous erythrocytes. CONCLUSION: Acute reduction of hemoglobin concentration to 7 g/dl does not produce detectable changes in human cognitive function. Further reduction of hemoglobin level to 6 and 5 g/dl produces subtle, reversible increases in reaction time and impaired immediate and delayed memory. These are the first prospective data to demonstrate subtle degraded human function with acute anemia of hemoglobin concentrations of 6 and 5 g/dl. This reversibility of these decrements with erythrocyte transfusion suggests that our model can be used to test the efficacy of erythrocytes, oxygen therapeutics, or other treatments for acute anemia.

Adult↗

Electrocardiographic ST-segment changes during acute, severe isovolemic hemodilution in humans.

BACKGROUND: Controversy exists regarding the lowest blood hemoglobin concentration that can be safely tolerated. The authors studied healthy resting humans to test the hypothesis that acute isovolemic reduction of blood hemoglobin concentration to 5 g/dl would produce an imbalance in myocardial oxygen supply and demand, resulting in myocardial ischemia. METHODS: Fifty-five conscious healthy human volunteers were studied. Isovolemic removal of aliquots of blood reduced blood hemoglobin concentration from 12.8 +/- 1.2 to 5.2 +/- 0.5 g/dl (mean +/- SD). Removed blood was replaced simultaneously with intravenous fluids to maintain constant isovolemia. Hemodynamics and arterial oxygen content (Cao2) were measured before and after removal of each aliquot of blood. Electrocardiographic (ECG) changes were monitored continuously using a Holter ECG recorder for detection of myocardial ischemia. RESULTS: During hemodilution, transient, reversible ST-segment depression developed in three subjects as seen on the electrocardiogram during hemodilution. These changes occurred at hemoglobin concentrations of 5-7 g/dl while the subjects were asymptomatic. Two of three subjects with ECG changes had significantly higher heart rates than those without ECG changes at the same hemoglobin concentrations. When evaluating the entire study period, the subjects who had ECG ST-segment changes had significantly higher maximum heart rates than those without ECG changes, despite having similar baseline values. CONCLUSION: With acute reduction of hemoglobin concentration to 5 g/dl, ECG ST-segment changes developed in 3 of 55 healthy conscious adults and were suggestive of, but not conclusive for, myocardial ischemia. The higher heart rates that developed during hemodilution may have contributed to the development of an imbalance between myocardial supply and demand resulting in ECG evidence of myocardial ischemia. However, these ECG changes appear to be benign because they were reversible and not accompanied by symptoms.

Adult↗

Guiding the decision to transfuse.

Guiding the decision to transfuse can improve transfusion practices. Effective processes must first identify problem(s) in transfusion practice and then include the attending physician as an educational target. Process improvements that have been shown to be effective include the following: (1) briefly meeting one-on-one with physicians, (2) teaching at scheduled conferences, (3) making daily clinical rounds of patients who receive transfusion, (4) concurrently reviewing orders for transfusion before issue of the blood product, and (5) installing algorithms and guidelines in the operating room. Transfusion practices improved with these process improvements.

Blood Transfusion↗

Human cardiovascular and metabolic response to acute, severe isovolemic anemia.

CONTEXT: Although concern over the risks of red blood cell transfusion has resulted in several practice guidelines for transfusion, lack of data regarding the physiological effects of anemia in humans has caused uncertainty regarding the blood hemoglobin (Hb) concentration requiring treatment. OBJECTIVE: To test the hypothesis that acute isovolemic reduction of blood Hb concentration to 50 g/L in healthy resting humans would produce inadequate cardiovascular compensation and result in tissue hypoxia secondary to inadequate oxygen transport. DESIGN: Before and after interventional study. SETTING: Academic tertiary care medical center. PARTICIPANTS: Conscious healthy patients (n =11) prior to anesthesia and surgery and volunteers not undergoing surgery (n=21). INTERVENTIONS: Aliquots of blood (450-900 mL) were removed to reduce blood Hb concentration from 131 (2) g/L to 50 (1) g/L [mean (SE)]. Isovolemia was maintained with 5% human albumin and/or autologous plasma. Cardiovascular parameters, arterial and mixed venous oxygen content, oxyhemoglobin saturation, and arterial blood lactate were measured before and after removal of each aliquot of blood. Electrocardiogram and, in a subset, Holter monitor were monitored continuously. MAIN OUTCOME MEASURES: "Critical" oxygen delivery (TO2) as assessed by oxygen consumption (VO2), plasma lactate concentration, and ST changes on electrocardiogram. RESULTS: Acute, isovolemic reduction of Hb concentration decreased systemic vascular resistance and TO2 and increased heart rate, stroke volume, and cardiac index (each P<.001). We did not find evidence of inadequate oxygenation: VO2 increased slightly from a mean (SD) of 3.07 (0.44) mL of oxygen per kilogram per minute (mL O2 x kg(-1) x min[-1]) to 3.42 (0.54) mL O2 x kg(-1) x min(-1) (P<.001) and plasma lactate concentration did not change (0.81 [0.11] mmol/L to 0.62 [0.19] mmol/L; P=.09). Two subjects developed significant ST changes on Holter monitor: one apparently related to body position or activity, the other to an increase in heart rate (at an Hb concentration of 46-53 g/L); both occurred in young women and resolved without sequelae. CONCLUSIONS: Acute isovolemic reduction of blood Hb concentration to 50 g/L in conscious healthy resting humans does not produce evidence of inadequate systemic TO2, as assessed by lack of change of VO2 and plasma lactate concentration. Analysis of Holter readings suggests that at this Hb concentration in this resting healthy population, myocardial ischemia would occur infrequently.

Adult↗

The transfusion audit as an educational tool.

Audits of transfusion used as educational tools can improve transfusion practices. Effective audits must first identify problem(s) in transfusion practice and must then include as educational target, the attending physician. Educational methods that have been shown to the effective include: (1) meeting briefly one-on-one with physicians, (2) teaching at scheduled conferences, (3) making daily clinical rounds on patients who receive transfusion, (4) concurrent review of orders for transfusion prior to issue of the blood product and (5) installing algorithms and guidelines in the operating room. Transfusion practices improved with these educational audit methods.

Blood Transfusion↗

A quality improvement team on autologous and directed-donor blood availability.

BACKGROUND: Until 1985, volunteer donors provided blood for almost all transfusions and donated blood was rarely restricted for transfusion to a specific patient. With the AIDS (Acquired Immunodeficiency Syndrome) crisis, autologous (blood from oneself) and directed (blood from families and friends) donations increased, calling for handling of far greater complexity. At the University of California at San Francisco Medical Center, the demand for special donations superseded the development of systems to meet the demand and autologous and/or directed donations were often not available when needed. After a rapid rise in incident reports and complaints from physicians, nurses, patients, and families, a quality improvement (QI) team was formed in mid-1991 to improve blood availability. METHOD: Meetings were held to analyze the processes involved in blood donation and transfusion, identify and categorize problems, develop interventions, test and implement solutions, and monitor improvements. Educational efforts were implemented throughout the medical center, recruitment for a special donations co-ordinator began, and changes were made in the blood bank's internal systems. RESULTS: In two years, with stable numbers of transfused units, the number of incident reports regarding blood availability decreased from 19 to 2 per year-an improvement that has been sustained for more than three years. The QI team continues to meet regularly to design and implement additional improvements. CONCLUSION: A QI team has improved the availability of autologous and directed-donor blood to patients and has extended the impact of the QI methodology throughout the medical center as a whole.

Academic Medical Centers↗

Preoperative autologous donation: surgery clinic staff knowledge/attitudes. Preoperative Autologous Blood Donation Study Group.

Preoperative autologous blood donation (PABD) is both under- and overused. Although the decision to order PABD lies with the surgeon, it is quite likely that other surgery clinic personnel influence patient acceptance and enrollment into PABD programs. Accordingly, we measured knowledge, attitudes, and the referral practice of clinic personnel pertaining to PABD. We administered a questionnaire to 102 nurses and 33 clerks working in surgery clinics at three university medical centers--one center in an area with a high incidence of AIDS and two centers in areas of low incidence of AIDS. Knowledge of PABD was poor when assessed by six questions. Only 6% each of nurses and clerks answered all questions correctly; 55% of nurses and 54% clerks missed three or more of the six questions. Surprisingly, no differences (P > .05) in knowledge deficits were noted when personnel from high and low AIDS areas were compared--indicating an overall need for education about PABD. In general, attitudes about PABD were positive, as most respondents (63%) gave favorable answers. Clinic personnel from the high AIDS area had even more favorable attitudes (P = .02). Because of these favorable attitudes, it seems likely that educational programs dealing with PABD would be readily accepted by clinic personnel. Greater knowledge should enhance the effectiveness of clinic staff in identifying, counseling, and referring eligible patients for this service.

Acquired Immunodeficiency Syndrome↗

Comparative study of the immunogenicity and safety of two dosing schedules of Engerix-B hepatitis B vaccine in neonates.

A randomized multicenter study compared the routine hepatitis B vaccine schedule of 0, 1, 6 months with an accelerated schedule of 0, 1, 2 months in newborns. Two hundred ninety-nine infants whose mothers were seronegative for hepatitis B were enrolled in the study and randomized to either the routine or accelerated schedule. All infants had blood drawn for antibody titers to hepatitis B at 2, 3, 6 and 7 months of age. For 222 infants data were evaluable, at least for safety; 193 of these 22 had antibody titers that were evaluable. The infants vaccinated on the accelerated schedule developed seroprotective concentrations of antibody more quickly than the infants vaccinated on the routine schedule; 92.6% vs. 66.1% had seroprotective concentrations (> or = 10 mIU/ml) at 3 months of age (P < 0.001). However, infants in the accelerated schedule had lower geometric mean antibody titers at 7 months, 420.0 vs. 3141.8. We conclude that the accelerated vaccination schedule resulted in the more rapid development of seroprotective concentrations of antibody, but levels of antibodies were not as high as in the routinely vaccinated infants at 7 months. These data suggest that an accelerated vaccine schedule can be used in the newborn period. The effectiveness of the accelerated schedule in preventing perinatal infections compared to the standard schedule and the necessity for booster doses of vaccine remain to be studied.

Drug Administration Schedule↗

A monoclonal antibody against the c-erbB-2 protein enhances the cytotoxicity of cis-diamminedichloroplatinum against human breast and ovarian tumor cell lines.

A monoclonal antibody (TAb 250) specific to an extracellular epitope of the c-erbB-2 protein (gp185) inhibited the in vitro proliferation of human breast tumor cell lines that overexpress c-erbB-2 in a dose-dependent manner. Treatment of cells with combinations of cis-diammedichloroplatinum (CDDP) and TAb 250 resulted in a significantly enhanced cytotoxic effect. This synergistic cytotoxicity was apparent over a wide range of antibody concentrations (200 pg/ml-100 micrograms/ml) including concentrations that showed no inhibitory effect alone. TAb 250 did not increase the cytotoxic effect of CDDP in a cell line exhibiting no detectable level of gp185. Athymic mice bearing s.c. xenografts of human tumor cells expressing high levels of gp185 showed a greatly enhanced inhibition of tumor growth when treated with TAb 250 and CDDP compared to treatment with the antibody or CDDP alone. This effect was specific inasmuch as TAb 250 did not enhance the growth-inhibitory effect of CDDP on tumor xenografts which were not expressing gp185.

Animals↗

Alteration of amino-terminal codons of human granulocyte-colony-stimulating factor increases expression levels and allows efficient processing by methionine aminopeptidase in Escherichia coli.

We have improved the expression of recombinant human granulocyte-colony-stimulating factor (G-CSF), produced by either pL or trpP expression vectors in Escherichia coli, by altering the sequence at the 5' end of the G-CSF-coding region. Initial attempts to express G-CSF resulted in neither detectable G-CSF mRNA nor protein in the trpP system, and only G-CSF mRNA was detectable in the pL system. We modified both expression vectors to decrease the G + C content of the 5' end of the coding region without altering the predicted amino acid sequence. This resulted in expression of detectable G-CSF mRNA and protein in both systems. Expression reached 17% and 6.5% of the total soluble cellular protein in the pL and trpP expression systems, respectively. The N-terminal sequence of the recombinant G-CSF from the pL system was Met-Thr-Pro-Leu-Gly-Pro-. G-CSF isolated from several human cell lines (including the LD-1 cell line reported here), does not have an N-terminal methionyl residue. Deletion of the threonine codon at the beginning of the coding region for the mature G-CSF resulted in efficient removal of the N-terminal methionine residue during expression in E. coli.

Aminopeptidases↗