PURPOSE: To evaluate the results of implanting convex, iris-fixated, anterior chamber intraocular lenses (IOLs) in phakic eyes to correct high hyperopia. SETTING: Robert Koch Hospital, Hannover-Gehrden, Germany (Center A), and Dr. Daljit Singh Eye Hospital, Amritsar, India (Center B). METHOD: Two eyes at Center A and 67 at Center B had implantation of an anterior chamber, convex, iris-fixated IOL. Follow-up of the 2 eyes at Center A was 91 months. Mean follow-up at Center B was 78 months +/- 24 (SD) (range 12 to 120 months). RESULTS: At Center B, all eyes except two in one patient had clear corneas and no iritis or glaucoma at the last follow-up. The patient with complications (glaucoma and corneal degeneration in both eyes) did not return for follow-up until more than 4 years postoperatively and thus did not have adequate postoperative care. CONCLUSION: Implantation of a convex iris-claw lens into the anterior chamber of phakic eyes to correct high hyperopia was successful from a refractive aspect. The clinical risks appear tolerable. However, life-long observation by endothelial microscopy is mandatory.
Explore the source record for details and available documents.
OBJECTIVE: To determine the best technique for implanting a hypernegative intraocular lens (IOL) in the posterior chamber of phakic eyes to neutralize high myopia and its results. SETTING: Robert Koch Hospital, Hannover-Gehrden, Germany. METHODS: We implanted the Chiron-Adatomed silicone myopia IOL in 69 eyes of 37 patients between June 1992 and August 1994 and followed them prospectively. RESULTS: To avoid marked decentration, the IOL should merely touch the ciliary sulcus. Its best length should equal the horizontal diameter of the cornea (white to white). Iritis from implantation trauma was avoided by intravenous administration of 250 mg prednisone preoperatively. When inserting the Chiron-Adatomed myopia IOL, we avoided putting pressure on the crystalline lens with the spatula. In 53 eyes, the difference between precalculated postoperative refraction and achieved postoperative refraction at 3 months was +0.07 +/- 1.05 diopters (D) (mean +/- SD). No eye deviated more than 2.80 D. Eleven of 69 eyes had a follow-up of fewer than 6 months and 13 had marked preoperative cortical opacities. Eight of the remaining 45 eyes with clear or almost clear cortexes showed a central subcapsular opacity after 1 to 2 years, probably IOL induced. CONCLUSION: Use of the Chiron-Adatomed IOL should be confined to older patients with early cataract until its role as the cause of opacities has been clarified by further observation.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
An intraocular lens (IOL) with an inverse (reversed) optic has the convex surface directed toward the retina, a design which has many advantages. We have developed a "super-reversed" IOL by increasing the angle of the haptic from 10 to 20 degrees and by increasing the convexity of the posterior surface (necessitating a concave anterior surface). The main advantage of this model is the distance of approximately 6.3 mm between the anterior corneal surface and the posterior IOL surface. This configuration mimics the natural situation. We report on the implantation of 473 lenses of this design.
Explore the source record for details and available documents.
We corrected myopia in 62 phakic eyes by fixing a concave intraocular lens to the midperiphery of the iris in the anterior chamber. No inflammation, glaucoma, corneal edema, or intraocular lens induced-cataract has occurred. The lens did not touch the corneal endothelium. The achieved correction was within 10% in 47 of the 62 eyes (76%) and within 20% of the expected correction in all eyes.
Hydroxypropyl methylcellulose solutions (2% HPMC) were examined for impurities. There was no evidence of any particulate matter in two solutions from different sources: one prepared by a hospital pharmacy, the other industrially prepared (Adatocel). In a controlled clinical study, Adatocel was compared with Healon (1% hyaluronic acid solution). The postoperative irritation (cellular response) in the anterior chamber was the same in both groups.
An intraocular lens with a reversed optic and with haptics angulated forward presses the posterior capsule more posteriorly than other types of lenses. This position is thought to be important even in eyes that do not need intraocular lenses for optical reasons, such as eyes with high axial myopia (because of their increased tendency to postoperative retinal detachment) and eyes with postoperative capsular fibrosis. "Zero lenses" were implanted in seven eyes. The lenses had a convex posterior surface and a concave anterior surface which were parallel. The position of the posterior capsule, measured with ultrasound, was 4.9 mm to 5.8 mm (mean 5.5 mm) behind the anterior corneal surface. In two fellow eyes without a lens (after planned extracapsular cataract extraction), the posterior capsule was 4.1 mm and 4.3 mm behind the anterior corneal surface.
A biconcave intraocular lens for the correction of myopia is described and preliminary results are presented. An iris claw-type lens is used as a carrier for the biconcave lens. This lens is fixed in front of the natural lens in the mid-periphery of the iris. It maintains a sufficient distance from both the natural lens and the corneal endothelium. The surgical technique is described in detail and the indications and contraindications are discussed. The authors' results so far are encouraging.
The implantation of a concave intraocular lens (IOL) (Worst-Fechner Biconcave Lens) is a new method of correcting myopia. This paper describes how to compute the effective power of an IOL on the basis of corneal curvature and anterior chamber depth, i.e., which lens will neutralize a specific myopia. The authors also discuss the size of the retinal image of an eye corrected by an intraocular lens as compared to an eye corrected by a spectacle glass.
The iris claw lens does not have some of the disadvantages of lenses fixed in the anterior chamber angle. It is clipped to the iris from the front and does not touch the structures of the angle. It is useful as a stand-by lens and for secondary implantations, as well as for certain other indications, such as a traumatized eye with anterior synechiae. It is conceivable that in the future this lens type may gain in importance as a carrier of a concave optic for use in myopic eyes.