PubMed Health⌕ Search

Biomedical subjects

P Udomkiat

Publications and source records attributed to P Udomkiat.

5 recordsLinked to original sources

[Tripolar arthroplasty for recurrent total hip prosthesis dislocation].

PURPOSE OF THE STUDY: The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. MATERIAL AND METHODS: Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). RESULTS: There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A revision procedure was necessary for one patient during the 4(th) year because of a fracture of the polyethylene insert on a metal-back cup; the insert alone was changed. Excepting the patient with infection, there were no cases of certain or probable loosening during the follow-up. DISCUSSION: The tripolar prosthesis with a mobile cup and a large-diameter head appears to be a reliable solution for these severely unstable hips. The procedure can often be limited to the acetabular component, reducing morbidity. The thickness of the polyethylene cup is a limitation which may affect long-term survival. Search for a highly wear-resistant couple continues.

Adult↗

Matched-pair analysis of all-polyethylene versus metal-backed tibial components.

Forty-eight matched pairs of osteoarthritic knees from patients who underwent primary total knee arthroplasty with a round-on-round, Apollo Knee System were studied to evaluate the outcome between all-polyethylene and metal-backed tibial components. Patients were matched for patient factors, preoperative deformities, cruciate salvage or sacrifice, and surgical technique. At the last follow-up (average, 38.4 months), there was no statistically significant difference in terms of knee scores, patient self-assessment, and radiographic outcomes. No component required revision, and no revisions were pending. Maintenance of these results over time would project into better long-term success for all-polyethylene tibial components because of the amount of wear and osteolysis with current modular metal-backed tibial components. We advocate the use of a more cost-effective all-polyethylene tibial component in elderly patients (>70 years old) who are not likely to need the versatility of exchange of a modular polyethylene insert because of wear.

Adult↗

Technical factors for success with metal ring acetabular reconstruction.

Sixty-four hips in 62 patients were revised with a Mueller ring (28 hips), Ganz ring (18 hips), and Burch-Schneider cage (18 hips) under the direction of a single surgeon. A polyethylene cup was cemented into the metal support of all hips. Average follow-up was 4.6 years (range, 2.0-6.7 years). Six rings were revised because of aseptic loosening, and 5 others were radiographically loose, for a mechanical failure rate of 11 of 64 (17%). Acetabular metal ring supports failed by migration when defects of > or =60% of the superior weight-bearing bone were filled by only cement or particulate graft. At the time of surgery, the superior rim of the metal support should be against host-bone for 60% of its support, and if not, the use of bulk allograft, rather than particulate graft, is required. Dislocation was the second failure mechanism identified, and this occurred in 15 hips (23%), with reoperation required in 5 hips (8%). A constrained liner should be used in patients with nonunion of the trochanter and preoperative abductor weakness that grades fair/minus or worse as measured by the side-lying abduction test.

Acetabulum↗

Comparison of preoperative radiographs and intraoperative findings of fixation of hemispheric porous-coated sockets.

BACKGROUND: The radiographic criteria for identification of loose cementless acetabular components have not been well established. The purpose of this study was to compare the radiographic appearance of a hemispheric porous-coated cementless cup fixed with screws with the intraoperative findings with regard to the fixation status. METHODS: The quality of the cup fixation was evaluated at fifty-two hip revisions that were performed, for reasons other than infection, at an average of 89.9 months (range, 33.8 to 150.1 months) after the primary operations. The fixation status at the revision surgery was compared with the findings on sequential anteroposterior and lateral radiographs of these sockets. Sequential radiographs of an additional 100 total hip replacements that had not required a reoperation and that had been followed for an average of 121 months were also measured. RESULTS: Loosening of the socket was radiographically identified by (1) radiolucent lines that initially appeared after two years, (2) progression of radiolucent lines after two years, (3) radiolucent lines in all three zones, (4) radiolucent lines 2 mm or wider in any zone, or (5) migration. The sensitivity of these criteria was 94%, and the specificity was 100%. The criteria had a positive predictive value of 100% and a negative predictive value of 97%. CONCLUSIONS: The most predictive radiographic findings for early diagnosis of loosening of a hemispheric porous-coated cup were progression of radiolucent lines more than two years after the operation and any new radiolucent line of 1 mm or wider that appeared more than two years postoperatively. Sequential anteroposterior and lateral radiographs are necessary to assess the time of onset and progression of radiolucent lines in order to identify loose hemispheric porous-coated cups accurately.

Acetabulum↗

Functional comparison of posterior cruciate retention and substitution knee replacement.

Thirty-eight matched pairs of osteoarthritic knees from patients who underwent primary total knee replacements with minimum 2 years of followup were studied to compare the functional outcome between a cruciate retention and posterior stabilized design with essentially identical articulation surfaces. Patients were matched for age, weight, gender, diagnosis, activity, deformity of the knee, type of tibial component, and duration of followup. The patients were evaluated functionally by three methods: the Knee Society scoring system; a self-administered questionnaire; and an activity rating based on distance walked. In addition, in vivo fluoroscopic examination was performed in 10 cruciate retention and 10 posterior stabilized knees to determine the functional knee kinematics. Results showed that by patient self-assessment, functional improvement was achieved in 35 (92%) cruciate retention knees and 36 (95%) posterior stabilized knees. There was no statistically significant difference between the two groups in the clinical evaluations. Fluoroscopic kinematics showed that the posterior stabilized knee experienced anteroposterior femorotibial translation more similar to the normal knee during normal gait and deep knee bend. These clinically equivalent results are not in agreement with the predicted better functional results of cruciate retained knees as determined by gait studies.

Aged↗