PubMed Health⌕ Search

Biomedical subjects

P V Prasad

Publications and source records attributed to P V Prasad.

At least 19 recordsLinked to original sources

dGEMRIC as a function of BMI.

OBJECTIVE: Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) reflects cartilage glycosaminoglycan (GAG) distribution. The technique assumes that the plasma levels of the contrast agent Gd-DTPA(2-) are the same across individuals after intravenous (IV) injection, when dosing by weight. However, adipose tissue has lower extracellular water (ECW) than lean tissue. The aims of this study were to measure (1) plasma Gd-DTPA(2-) levels vs body mass index (BMI), and (2) dGEMRIC vs BMI after correcting for the dose-BMI effect. METHOD: (1) Plasma Gd-DTPA(2-) levels were analyzed at 3-90 min after IV injection per body weight in 24 individuals with BMI between 21.5 and 46.5. (2) dGEMRIC was compared with BMI in 19 asymptomatic volunteers and 23 with osteoarthritis (OA). RESULTS: (1) Plasma Gd-DTPA(2-) kinetics were similar in obese and non-obese groups, however, overall concentration was higher in the obese group. A very obese subject (BMI 45) would have 1.4 times higher Gd-DTPA(2-) concentration than a lean subject (BMI 20), which translates into a bias in dGEMRIC of up to 20%. (2) With dose bias taken into account, dGEMRIC showed no correlation with BMI in asymptomatic knees. In OA knees, unnarrowed femoral compartments demonstrated a negative correlation between dGEMRIC and BMI (R=0.57, P=0.004). No correlation was seen in radiographically narrowed compartments. CONCLUSION: BMI can be a source of dosing bias in dGEMRIC and a correction factor should be considered in cross-sectional studies with a large range of BMI. There is no correlation between dGEMRIC and BMI in asymptomatic knees, but a negative correlation in OA knees.

Adult↗

Evaluation of intra-renal oxygenation during water diuresis: a time-resolved study using BOLD MRI.

Hypoxia of the renal medulla is a possible precursor to the onset of acute renal failure in humans and therefore an understanding of the factors influencing the oxygenation status within the renal medulla is very important. Blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI) has been shown to non-invasively evaluate intra-renal oxygenation levels of the renal medulla in humans. A newly implemented three-dimensional (3-D) multiple gradient-recalled echo sequence, which permits examination of temporal responses to physiological or pharmacological stimuli, was used to monitor changes in intra-renal oxygenation status during water diuresis. Five healthy, young subjects (22+/-1.2 years) took part in the study. BOLD MRI data were acquired before and after water loading. Studies were repeated on a separate day after the subjects were pretreated with naproxen. Water diuresis significantly improved renal medullary oxygenation levels in all subjects (pre-waterload=30.3 1/s vs post-waterload 22.8 1/s); however, the temporal response was found to be subject dependent. In the presence of cyclooxygenase (COX) inhibition by naproxen, the improvement in oxygenation during water diuresis was completely abolished (pre-waterload=27.5 1/s vs post-waterload 28.5 1/s). Monitoring of temporal responses for the first time during water loading allowed for an appreciation of subject dependence. Comparison of the temporal response in terms of slopes demonstrated a significant difference between the waterload studies with and without naproxen (with naproxen=0.056 1/(s min) vs without naproxen=0.25 1/(s min)). The observed effects of naproxen were consistent with previous findings with COX inhibition.

Adult↗

Hydrogen peroxide modulates meiotic cell cycle and induces morphological features characteristic of apoptosis in rat oocytes cultured in vitro.

Hydrogen peroxide (H2O2) is known to induce cell cycle arrest and apoptosis in various somatic cell types cultured in vitro. We hypothesize that this reactive oxygen species (ROS) could modulate cell cycle and induce morphological features characteristics of apoptosis in oocytes cultured in vitro. To test this hypothesis, immature and mature oocytes were cultured in medium containing various doses of H2O2 with or without caspase-3 inhibitor for various times. The treatment of H2O2 induced germinal vesicle break down (GVBD) in all immature oocytes followed by initiation of shrinkage. Some of immature oocytes (but not mature oocytes) also showed membrane blebbing. On the other hand, H2O2 treatment inhibited first polar body emission in mature oocytes just prior to initiation of shrinkage. The cytoplasmic granulation and fragmentation into apoptotic bodies were observed in mature oocytes during later stages of H2O2 treatment. The shrinkage was induced by H2O2 in a dose- and time-dependent manner in both immature and mature oocytes. Although, H2O2-induced degeneration was observed in both immature and mature oocytes after 2.0 hrs of treatment, immature oocytes were more susceptible to undergo quick shrinkage, membrane blebbing and degeneration. Co-addition of caspase-3 inhibitor prevented shrinkage and degeneration of both immature and mature oocytes except membrane blebbing that was observed at higher doses of H2O2 after 1.0 hr of culture. Treatment of H2O2 induced bax protein expression (3 times), DNA fragmentation and caspase-3 activity (2.5 times) in oocytes undergoing morphological apoptotic changes. These findings clearly suggest that H2O2 induced GVBD in immature oocytes, inhibited first polar body extrusion in mature oocytes prior to initiation of morphological changes characteristic of apoptosis such as shrinkage, membrane blebbing and cytoplasmic fragmentation prior to degeneration.

Animals↗

T1 efficacy of EVP-ABD: a potential manganese-based MR contrast agent for hepatic vascular and tissue phase imaging.

PURPOSE: To evaluate the T1 efficacy of EVP-ABD, a new manganese (Mn)-based contrast agent, for vascular and liver tissue enhancement in comparison with currently approved agents. MATERIALS AND METHODS: Ten Yorkshire pigs (body weight, 26 -46 kg) were used for the efficacy evaluation, nine for kinetic T1 evaluation (three each agent) and one for post EVP-ABD imaging. With a fast imaging scheme to monitor T1 values of blood and liver, 10 micromol/kg EVP-ABD was injected intravenously and compared with gadopentetate dimeglumine (Magnevist, GdDTPA) and mangafodipir trisodium (Teslascan, mangafodipir trisodium) at routine clinical dosages. All were imaged with 3D T1 Gradient Recalled Echo (GRE) sequence (TR/TE/alpha = 3.8/1.6/25 degrees ) prior to and 10 minutes post injection using a 1.5-T whole-body scanner. Additional high-resolution 2D liver images (TR/TE/alpha = 50/4.6/40 degrees ) and arterial phase images of the upper aorta were acquired from the pig for post EVP-ABD imaging. RESULTS: At 10 micromol/kg, EVP-ABD provided a dramatic decline in blood T1, comparable to 0.1 mmol/kg GdDTPA, followed by a rapid return to blood baseline T1 values. In addition to the blood enhancement phase, EVP-ABD achieved a 70% reduction in liver T1 within 2 minutes postadministration, with an imaging window of at least 2 hours. A substantially improved signal-to-noise ratio (SNR) was observed in both the 2D and 3D liver images postcontrast. CONCLUSION: EVP-ABD demonstrated peak vascular enhancement similar to GdDTPA and prolonged specific liver enhancement exceeding mangafodipir trisodium. EVP-ABD has favorable T1 enhancing characteristics with the potential to allow for a comprehensive liver evaluation.

Animals↗

Changes in intrarenal oxygenation as evaluated by BOLD MRI in a rat kidney model for radiocontrast nephropathy.

The pathogenesis of radiocontrast nephropathy is poorly understood. In an animal model, inhibition of the synthesis of nitric oxide and prostaglandins appears to predispose rats to severe renal injury following the administration of radiocontrast. Here we have investigated whether administration of radiocontrast, as well as changes in renal medullary oxygenation following pharmacologic inhibition of nitric oxide and prostaglandin synthesis, might be evaluated by blood oxygenation level-dependent (BOLD) MRI. Nineteen anesthetized (Inactin 100 mg/kg) rats were studied. BOLD MRI measurements were performed following administration of L-NAME (N-nitro-L-arginine methyl ester, 10 mg/kg), Indomethacin (10 mg/kg), and a radiocontrast agent (sodium iothalamate 60%, 6 mL/kg). Marked sequential changes in medullary R(*)(2), presumably reflecting decline in medullary pO(2), were noted after each of the pharmacological interventions employed. These results, obtained by noninvasive MRI, are consistent with prior direct recordings of pO(2) and doppler flow in the rat renal medulla after administration of L-NAME, Indomethacin and iothalamate. Medullary oxygenation in rats was reduced by inhibition of the synthesis of prostaglandins and nitric oxide, as well as by intravenous injection of radiocontrast agents. BOLD MRI can noninvasively evaluate changes in medullary oxygenation in rats that appear to predispose acute renal failure. J. Magn. Reson. Imaging 2001;13:744-747.

Animals↗

MR ventilation-perfusion imaging of human lung using oxygen-enhanced and arterial spin labeling techniques.

Magnetic resonance ventilation-perfusion (V/Q) imaging has been demonstrated using oxygen and arterial spin labeling techniques. Inhaled oxygen is used as a paramagnetic contrast agent in ventilation imaging using a multiple inversion recovery (MIR) approach. Pulmonary perfusion imaging is conducted using a flow-sensitive alternating inversion recovery with an extra radiofrequency pulse (FAIRER) technique. A half Fourier single-short turbo spin echo (HASTE) sequence is used for data acquisition in both techniques. V/Q imaging was performed in ten of the twenty volunteers, while either ventilation or perfusion was imaged in the other ten. This V/Q imaging scheme is completely noninvasive, does not involve ionized radiation, and shows promising potential for clinical use in the diagnosis of lung diseases such as pulmonary embolism.

Adult↗

Pulmonary ventilation: dynamic MRI with inhalation of molecular oxygen.

We have recently demonstrated a non-invasive technique to visualize pulmonary ventilation in humans with inhalation of molecular oxygen as a paramagnetic contrast agent. In the current study, T1 shortening of lung tissue by inhalation of oxygen was observed (P<0.001). The T1 values of lung tissue were also correlated with arterial blood oxygen pressure (PaO(2)) in a pig, resulting in excellent correlation (r(2)=0.997). Dynamic wash-in and wash-out MR ventilation images as well as dynamic wash-in wash-out signal intensity versus time curves were obtained. The mean wash-in decay constants were 26.8+/-10.5 s in the right lung, and 26.3+/-9.5 s in the left lung. The mean wash-out decay constants were 23.3+/-11.3 s in the right lung, and 20.8+/-10.5 s in the left lung. Dynamic assessment of pulmonary ventilation is feasible using oxygen-enhanced MR imaging, which could provide dynamic MR ventilation-perfusion imaging in combination with recently developed MR perfusion imaging technique, and thus a robust tool for the study of pulmonary physiology and pathophysiology.

Animals↗

Magnetic resonance imaging in endourology.

Historically, the utilization of magnetic resonance imaging (MRI) in endourology has been limited. The availability of faster and stronger gradient systems has given rise to a number of data acquisition strategies that have significantly broadened the scope of MRI applications. These methods have led to the evaluation of anatomy and function using a single modality, and we describe our experience with MRI for comprehensive evaluation of the obstructed ureteropelvic junction. We also utilize these new imaging sequences in the investigation of alterated renal hemodynamics after extracorporeal shockwave lithotripsy and present our preliminary data on the application of MR perfusion imaging as a noninvasive technique for the evaluation of renal blood flow.

Contrast Media↗

Dynamic three-dimensional magnetic resonance abdominal angiography and perfusion: implementation and preliminary experience.

Implementation of and preliminary experience with an ultra-fast partial-Fourier radiofrequency (RF) spoiled gradient-echo sequence for gadolinium-enhanced imaging are presented. Three-dimensional angiograms can be acquired in less than 6 seconds. Repetition of the acquisition allows the three-dimensional visualization of several distinct vascular phases. Feasibility is demonstrated in three healthy volunteers. The trade-offs among spatial resolution, temporal resolution, and spatial coverage as well as the technical aspects of gadolinium-enhanced pulse sequences are discussed.

Abdomen↗

Semiquantitative assessment of uterine perfusion using first pass dynamic contrast-enhanced MR imaging for patients treated with uterine fibroid embolization.

The feasibility of using first pass dynamic contrast-enhanced MRI to monitor semiquantitatively the perfusion changes of the uterus after uterine arterial embolization is demonstrated. Ten women, who underwent uterine arterial embolization for fibroid treatment, were included in this study. To derive a perfusion index, an additional axial slice through the abdominal aorta was obtained simultaneously when acquiring MR perfusion data. This technique may prove valuable in monitoring the outcome of uterine arterial embolization and documentation of preserved uterine perfusion after this procedure. J. Magn. Reson. Imaging 2000;12:1004-1008.

Adult↗

Noninvasive pulmonary perfusion imaging by STAR-HASTE sequence.

The STAR-HASTE sequence has been shown to be useful for perfusion imaging in areas that are plagued by magnetic susceptibility artifacts. Pulmonary perfusion imaging with this technique was attempted in this study. Quantitative analysis was also conducted, using an appropriate kinetic model in one subject. In six healthy subjects, gradual enhancement was observed in pulmonary artery to distal lung parenchyma when inflow time was increased. Our initial results suggest that noninvasive evaluation of pulmonary perfusion by magnetic resonance imaging without administration of an exogenous agent is possible.

Adult↗

Protective effect of aminophylline on renal perfusion changes induced by high-energy shockwaves identified by Gd-DTPA-enhanced first-pass perfusion MRI.

PURPOSE: The purpose of this study was to evaluate regional renal hemodynamics in a noninvasive manner using gadolinium-DPTA magnetic resonance imaging (MRI) before and after extracorporeal shockwave lithotripsy (SWL). In addition, the renoprotective effect of intravenous aminophylline was evaluated on the perfusion on kidneys undergoing SWL. PATIENTS AND METHODS: Ten randomly selected patients were evaluated for regional renal blood flow in the cortex and medulla with Gd-DTPA MRI studies within 2 weeks before and 4 hours after SWL. Five of these patients were treated with 500 mg of intravenous aminophylline 45 minutes prior to SWL. Renal hemodynamics were assessed utilizing relative perfusion indices (PI) calculated from signal intensity-v-time curves obtained from regions of interest (ROI). The ROI choice was based on the contrast-enhanced MRI images. Relative PIs of pre-SWL and post-SWL studies were compared in the first group of patients. Relative PIs of the treated kidney were compared with those of the contralateral kidney in the second group of patients, who received aminophylline. RESULTS: In the group not treated with aminophylline, there was no significant difference in cortical perfusion before SWL (average PI -7+/-3%). However, after lithotripsy, there was a reduction of cortical flow (average PI 31+/-12%) in the treated kidney. In the group treated with aminophylline, renal hemodynamics study after SWL revealed no significant difference in relative perfusion (average PI -8+/-6%). Relative PIs of the medulla were small for all patients, but standard errors were large, indicating a wide range of values. CONCLUSIONS: This study helps to establish reduced cortical flow after SWL and demonstrates that aminophylline attenuated this response in the kidneys subjected to lithotripsy. It appears that aminophylline administration causes no alteration in medullary blood flow.

Aminophylline↗

Effects of short episodes of heat stress on flower production and fruit-set of groundnut (Arachis hypogaea L.).

Groundnuts (Arachis hypogaea L.) are an important crop of the semi-arid tropics where they are often exposed to maximum temperatures of > 40 degrees C for short periods during the growing season. The objectives of this study were to determine: (i) the effects of short periods of exposure to high temperature on flower production (FN), the proportion of flowers forming fruits (fruit-set) and the number of pegs and pods per plant (RNt); (ii) whether fruit-set is affected by high temperature during different periods of daylight in each diurnal cycle; and (iii) whether responses to temperature were qualitative or quantitative. Plants of cv. ICGV 86015 were grown in controlled environments at a day/night temperature of 28/22 degrees C from sowing until 9 d after flowering (DAF). Then, cohorts of plants were: (a) exposed to day temperature of 28, 34, 42 or 48 degrees C for 2, 4 or 6 d; or were (b) exposed to 34, 42 or 48 degrees C for 6 d either throughout a 12 h day (08.00 to 20.00 h, WD), or only during the first 6 h (AM) or second 6 h (PM) of the day. Values of RNt were significantly reduced by high temperature, by duration of exposure, and by timing of exposure. Variation in FN was quantitatively related to floral bud temperatures during the day over the range 28-43 degrees C. In contrast, only floral bud temperatures > 36 degrees C during AM and WD significantly reduced fruit-set and hence RNt, whereas high PM temperature had no effect on fruit-set. These findings indicate that the response of RNt to day temperature is quantitative and can be modelled by combining the responses of FN and fruit-set to temperature.

Arachis↗

Captopril MR renography in a swine model: toward a comprehensive evaluation of renal arterial stenosis.

PURPOSE: To test the feasibility of captopril magnetic resonance (MR) renography and to validate the technique in an animal model of renal arterial stenosis. MATERIALS AND METHODS: Seven pigs with induced renal arterial stenosis were studied. MR renography was performed with a T1-weighted approach by using three-dimensional fast imaging with steady-state precession, or FISP, sequences after administration of a bolus of 0.1 mmol of gadopentetate dimeglumine per kilogram of body weight. Captopril was administered to improve the specificity. RESULTS: The results demonstrate that differences in renographic curves and indices are observed only if an anatomically substantial stenosis, typically a diameter reduction of more than 70%, is present and captopril is administered. CONCLUSION: In this preliminary experience in an animal model, captopril MR renography provided data consistent with expectations based on conventional renographic results.

Angiotensin-Converting Enzyme Inhibitors↗

Effect of hyperbaric oxygen treatment on nitric oxide and oxygen free radicals in rat brain.

Oxygen (O(2)) at high pressures acts as a neurotoxic agent leading to convulsions. The mechanism of this neurotoxicity is not known; however, oxygen free radicals and nitric oxide (NO) have been suggested as contributors. This study was designed to follow the formation of oxygen free radicals and NO in the rat brain under hyperbaric oxygen (HBO) conditions using in vivo microdialysis. Male Sprague-Dawley rats were exposed to 100% O(2) at a pressure of 3 atm absolute for 2 h. The formation of 2,3-dihydroxybenzoic acid (2, 3-DHBA) as a result of perfusing sodium salicylate was followed as an indicator for the formation of hydroxyl radicals. 2,3-DHBA levels in hippocampal and striatal dialysates of animals exposed to HBO conditions were not significantly different from controls. However, rats treated under the same conditions showed a six- and fourfold increase in nitrite/nitrate, break down products of NO decomposition, in hippocampal and striatal dialysates, respectively. This increase was completely blocked by the nitric oxide synthase (NOS) inhibitor L-nitroarginine methyl ester (L-NAME). Using neuronal NOS, we determined the NOS O(2) K(m) to be 158 +/- 28 (SD) mmHg, a value which suggests that production of NO by NOS would increase approximately four- to fivefold under hyperbaric O(2) conditions, closely matching the measured increase in vivo. The increase in NO levels may be partially responsible for some of the detrimental effects of HBO conditions.

Animals↗

Evaluation of changes in intrarenal oxygenation in rats using multiple gradient-recalled echo (mGRE) sequence.

Changes in intrarenal oxygenation in rats during pharmacological stimuli were evaluated with a multiple gradient-recalled echo (mGRE) sequence. With administration of the loop diuretic furosemide, oxygenation in the medulla improved; acetazolamide, a proximal tubular diuretic, produced no significant change. These results are consistent with our previous studies in humans and resemble earlier studies of medullary oxygenation using oxygen microelectrodes in anesthetized rats. The technique may be useful in the evaluation of therapeutic strategies in animal models of pathophysiological states such as acute renal failure.

Acetazolamide↗

Quantitative assessment of pulmonary perfusion with dynamic contrast-enhanced MRI.

The feasibility of qualitative assessment of pulmonary perfusion using dynamic contrast enhanced MRI with ultra-short TE has recently been demonstrated. In the current study, quantitative analysis was attempted based on the indicator dilution principle using a pig model of pulmonary embolism. The results were compared with the absolute pulmonary perfusion obtained with colored microspheres. The inverse of apparent mean transit time (1/tau(app)), distribution volume (V), and V/tau(app) were correlated well with the absolute lung perfusion. This study demonstrates that MR has the potential to evaluate pulmonary perfusion quantitatively. Magn Reson Med 42:1033-1038, 1999.

Adult↗

Fast magnetic resonance imaging techniques.

This article reviews fast magnetic resonance (MR) techniques currently used for body imaging. Improvements in gradient performance have made very short repetition and echo times on clinical scanners feasible, thus enabling subsecond image acquisition. The article provides a fundamental overview of the technical aspects from the concept of k-space and k-space segmentation technique, fast MR imaging techniques including fast spin echo, fast gradient echo with or without magnetization preparation to echo planar and hybrid techniques. The article also addresses the use of different fat suppression techniques in MR imaging of the body and improvements in coil technology to obtain faster images and higher signal-to-noise.

Echo-Planar Imaging↗