PubMed Health⌕ Search

Biomedical subjects

P Varley

Publications and source records attributed to P Varley.

6 recordsLinked to original sources

Novel use of accelerator mass spectrometry for the quantification of low levels of systemic therapeutic recombinant protein.

Although 14C-labelling has been routinely used for small molecules, this technique is not routinely applied to therapeutic proteins due to difficulties of incorporating the label into the protein to a sufficiently high specific activity. An analytical method known as accelerator mass spectrometry (AMS) offers an extremely sensitive method of 14C quantification, thereby enabling (14)C-labeling methods to be applied to therapeutic protein detection. The therapeutic protein CAT-192 (metelimumab), a human anti-TGFss1 monocloncal antibody was manufactured in the presence of 14C-precursors resulting in a low specific activity product (1.4% 14C incorporation). [14C]-CAT-192 was administered to rats (1mg/kg and 222, 22 and 2.2 dpm/kg) and serum samples were collected. 14C in serum samples from the 2.2 dpm dosing was not detectable but samples from the 22 and 2220 dpm doses were measured by AMS and by ELISA for comparison. By both ELISA and AMS bioassay, the half-lives approximated 140 h (S.E.M. 15 h). The estimates of clearance were also comparable, 7.3 and 4.6 x 10(-4)ml/h/g (S.E.M. 6.6 and 5.1 x 10(-5)) for ELISA and AMS, respectively. The estimated limit of quantification (LOQ) was approximately 1 ng/ml, about 15 times lower than the ELISA LOQ of 15.6 ng/ml.

Animals↗

Techniques for development of safety-related software for surgical robots.

Regulatory bodies require evidence that software controlling potentially hazardous devices is developed to good manufacturing practices. Effective techniques used in other industries assume long timescales and high staffing levels and can be unsuitable for use without adaptation in developing electronic healthcare devices. This paper discusses a set of techniques used in practice to develop software for a particular innovative medical product, an endoscopic camera manipulator. These techniques include identification of potential hazards and tracing their mitigating factors through the project lifecycle.

Marketing of Health Services↗

Kinetics of folding of the all-beta sheet protein interleukin-1 beta.

The folding of the all-beta sheet protein, interleukin-1 beta, was studied with nuclear magnetic resonance (NMR) spectroscopy, circular dichroism, and fluorescence. Ninety percent of the beta structure present in the native protein, as monitored by far-ultraviolet circular dichroism, was attained within 25 milliseconds, correlating with the first kinetic phase determined by tryptophan and 1-anilinonaphthalene-8-sulfonate fluorescence. In contrast, formation of stable native secondary structure, as measured by quenched-flow deuterium-hydrogen exchange experiments, began after only 1 second. Results from the NMR experiments indicated the formation of at least two intermediates with half-lives of 0.7 to 1.5 and 15 to 25 seconds. The final stabilization of the secondary structure, however, occurs on a time scale much greater than 25 seconds. These results differ from previous results on mixed alpha helix-beta sheet proteins in which both the alpha helices and beta sheets were stabilized very rapidly (less than 10 to 20 milliseconds).

Circular Dichroism↗

Emergence of tics in children with attention deficit hyperactivity disorder treated with stimulant medications.

The emergence of tics in children treated with stimulant medication for attention deficit hyperactivity disorder (ADHD) was investigated. A retrospective chart review of the medical records of 555 subjects was performed to examine the emergence of tics in relation to treatment with a stimulant medication, dosage, duration of treatment, and age of subjects. A total of 7.8% of the subjects treated with stimulants developed tics: 8.3% of subjects treated with methylphenidate, 6.3% with dextroamphetamine, and 7.7% with pemoline. The subjects who developed tics were significantly younger than those who did not. Subjects treated with higher doses of stimulant medication were not more likely to develop tics. While the emergence of tics was common, these subjects may have developed tics irrespective of stimulant medication. Controversy remains as to the long-term risk of tics in relation to stimulant medication and to appropriate practice should tics emerge during the course of stimulant medication treatment.

Attention Deficit Disorder with Hyperactivity↗