PubMed Health⌕ Search

Biomedical subjects

P W Arand

Publications and source records attributed to P W Arand.

2 recordsLinked to original sources

Power-afterload relation in the failing human ventricle.

Animal studies have shown that the power output of the left ventricle is related to afterload by a bell-shaped curve. Furthermore, the normal ventricle operates at the maximum power point, whereas the diseased ventricle operates off the maximum power point because of increased afterload. We studied this relation in eight patients with dilated cardiomyopathy. A high-fidelity catheter with micromanometer pressure and electromagnetic velocity transducers was used to measure blood pressure and flow velocity in the ascending aorta. The latter was converted into volumetric flow by calibrating with the simultaneously determined thermodilution cardiac output. Ventricular power was calculated by dividing the integral of the aortic blood pressure-flow product by the duration of the cardiac cycle. Intravenous nitroprusside was used to alter afterload and the power-afterload relation was obtained by plotting power against mean aortic blood pressure. In all patients, as blood pressure was lowered initially, the power output of the left ventricle increased. As the dose of nitroprusside was increased further, the total power either plateaued or actually decreased. The averaged power and the mean blood pressure at control were 1.00 +/- 0.62 W and 92 +/- 9.3 mm Hg, respectively. The averaged maximum increase in power with nitroprusside was 22%, to 1.22 +/- 0.73 W, and this occurred at a mean pressure of 80 +/- 8.8 mm Hg. This study showed that the power-afterload relation in the human ventricle has a maximum power point at some intermediate level of afterload, similar to that found in animal studies.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Determination of pulse wave velocities with computerized algorithms.

Careful determination of pulse wave velocity is important in the study of arterial viscoelastic properties, wave reflections, and ventricular-arterial interactions. In spite of its increasingly widespread use, there is as yet no standardized method for its determination. Most studies have manually identified the transit time of the pressure wave front as it travels over a known distance in the arterial system, but the issues of accuracy and reproducibility have not been addressed. This study was designed to investigate the efficacy of four computerized algorithms in the determination of pulse wave velocities in invasive as well as in noninvasive pressure determinations. The four methods were the identification of: (1) the point of minimum diastolic pressure, (2) the point at which the first derivative of pressure is maximum, (3) the point at which the second derivative of pressure is maximum, and (4) the point yielded by the intersection of a line tangent to the initial systolic upstroke of the pressure tracing and a horizontal line through the minimum point. High-fidelity aortic pressure recordings were obtained in 26 patients with a multi-sensor micromanometer catheter. Noninvasive brachial and radial pressure waveforms were recorded in 11 volunteers with external piezoelectric transducers. The results show that the first derivative method consistently provided results that were different from the other methods for both the invasive and noninvasive methods because of changes in the structure of the upstroke as the arterial pulse propagates distally. Although the minimum method worked well for the invasive determinations, it was erratic with the noninvasive determinations, probably because of the higher amount of noise and reflection in the latter. Among the four algorithms, the second derivative and the intersecting tangents methods worked well with both invasive and noninvasive determinations with mean variation coefficients of less than 7% and correlation coefficients between the methods of greater than 0.90 for all data. In conclusion, computerized algorithms allow accurate determination of pulse wave velocity in invasively and noninvasively measured arterial pressure waveforms.

Adult↗