Image segmentation of trabecular spongiosa by visual inspection of the gradient magnitude.

Recent advances in physical models of skeletal dosimetry utilize high-resolution 3-dimensional microscopic computed tomography images of trabecular spongiosa. These images are coupled to radiation transport codes to assess energy deposition within active bone marrow and trabecular endosteum. These transport codes rely primarily on the segmentation of the spongiosa images into bone and marrow voxels. Image thresholding has been the segmentation of choice for bone sample images because of its extreme simplicity. However, the ability of the segmentation to reproduce the physical boundary between bone and marrow depends on the selection of the threshold value. Statistical models, as well as visual inspection of the image, have been employed extensively to determine the correct threshold. Both techniques are affected by partial volume effect and can provide unexpected results if performed without care. In this study, we propose a new technique to threshold trabecular spongiosa images based on visual inspection of the image gradient magnitude. We first show that the gradient magnitude of the image reaches a maximum along a surface that remains almost independent of partial volume effect and that is a good representation of the physical boundary between bone and marrow. A computer program was then developed to allow a user to compare the position of the iso-surface produced by a threshold with the gradient magnitude. The threshold that produces the iso-surface that best coincides with the maximum gradient is chosen. The technique was finally tested with a set of images of a true bone sample with different resolutions, as well as with three images of a cube of Duocell aluminium foam of known mass and density. Both tests demonstrate the ability of the gradient magnitude technique to retrieve sample volumes or media volume fractions with 1% accuracy at 30 microm voxel size.

Aluminum Compounds↗

Voxel effects within digital images of trabecular bone and their consequences on chord-length distribution measurements.

Chord-length distributions through the trabecular regions of the skeleton have been investigated since the early 1960s. These distributions have become important features for bone marrow dosimetry; as such, current models rely on the accuracy of their measurements. Recent techniques utilize nuclear magnetic resonance (NMR) microscopy to acquire 3D images of trabecular bone that are then used to measure 3D chord-length distributions by Monte Carlo methods. Previous studies have shown that two voxel effects largely affect the acquisition of these distributions within digital images. One is particularly pertinent as it dramatically changes the shape of the distribution and reduces its mean. An attempt was made to reduce this undesirable effect and good results were obtained for a single-sphere model using minimum acceptable chord (MAC) methods (Jokisch et al 2001 Med. Phys. 28 1493-504). The goal of the present work is to extend the study of these methods to more general models in order to better quantify their consequences. First, a mathematical model of a trabecular bone sample was used to test the usefulness of the MAC methods. The results showed that these methods were not efficient for this simulated bone model. These methods were further tested on a single voxelized sphere over a large range of voxel sizes. The results showed that the MAC methods are voxel-size dependent and overestimate the mean chord length for typical resolutions used with NMR microscopy. The study further suggests that bone and marrow chord-length distributions currently utilized in skeletal dosimetry models are most likely affected by voxel effects that yield values of mean chord length lower than their true values.

Bone Marrow↗

Evolution and status of bone and marrow dose models.

Investigations at the University of Leeds under the direction of F.W. Spiers in the early 1960s through the late 1970s established the first comprehensive assessment of marrow dose conversion factors (DCFs) for beta-emitting radionuclides within the volume or on the surface of trabecular bone. These DCFs were subsequently used in deriving radionuclide S values for skeletal tissues published in MIRD Pamphlet No. 11. Eckerman re-evaluated this work and extended the methods of Spiers to radionuclides within the marrow to provide DCFs for fifteen skeletal regions in computational models representing individuals of six different ages. These results were used in the MIRDOSE3 software. Bouchet et al. used updated information on regional bone and marrow masses, as well as 3D electron transport techniques, to derive radionuclide S values in skeletal regions of the adult. Although these two efforts are similar in most regards, the models differ in three respects in: (1) the definition of the red marrow region, (2) the definition of a surface source of activity, and (3) the assumption applied in transporting electrons through the trabecular endosteum. In this study, a review of chord-based skeletal models is given, followed by a description of the differences in the Eckerman and Bouchet et al. transport models. Finally, new data from NMR microscopy and radiation transport in trabecular bone is applied to address item (1) above. Dose conversion factors from MIRD 11, the Eckerman model, the Bouchet et al. model, and a revised model are compared for several radionuclides important to internal emitter therapy.

Animals↗

Skeletal dosimetry via NMR microscopy: investigations of sample reproducibility and signal source.

Nuclear magnetic resonance microscopy has been used for several years as a means of quantifying the 3D microarchitecture of the cancellous regions of the skeleton. These studies were originally undertaken for the purpose of developing non-invasive techniques for the early detection of osteoporosis and other bone structural changes. Recently, nuclear magnetic resonance microscopy has also been used to acquire this same 3D data for the purpose of both (1) generating chord length data across bone trabeculae and marrow cavities and (2) generating 3D images for direct coupling to Monte Carlo radiation transport codes. In both cases, one is interested in the reproducibility of the dosimetric data obtained from nuclear magnetic resonance microscopy. In the first of two studies, a trabecular bone sample from the femoral head of a 51-y-old male cadaver was subjected to repeated image acquisition, image processing, image coupling, and radiation transport simulations. The resulting absorbed fractions at high electron energies (4 MeV) were shown to vary less than 4% among four different imaging sessions of the same sample. In a separate study, two femoral head samples were imaged under differing conditions of the NMR signal source. In the first case, the samples were imaged with intact marrow. These samples were then subjected to marrow digestion and immersed in Gd-doped water, which then filled the marrow cavities. Energy-dependent absorbed fraction profiles for both the marrow-intact and marrow-free samples showed essentially equivalent results. These studies thus provide encouragement that skeletal dosimetry models of improved patient specificity can be achieved via NMR microscopy in vivo.

Bone and Bones↗

Site-specific variability in trabecular bone dosimetry: considerations of energy loss to cortical bone.

With continual advances in radionuclide therapies, increasing emphasis is being placed on improving the patient specificity of dose estimates to marrow tissues. While much work has been focused on determining patient-specific assessments of radionuclide uptake in the skeleton, few studies have been initiated to explore the individual variability of absorbed fraction data for electron and beta-particle sources in various skeletal sites. The most recent values of radionuclide S values used in clinical medicine continue to utilize a formalism in which electrons are transported under a trabecular bone geometry of infinite extent. No provisions are thus made for the fraction of energy lost to the cortical bone cortex of the skeletal site and its surrounding tissues. In the present study, NMR microscopy was performed on trabecular bone samples taken from the femoral head and humeral proximal epiphysis of three subjects: a 51-year male, an 82-year female, and an 86-year female. Following image segmentation and coupling to EGS4, electrons were transported within macrostructural models of the various skeletal sites that explicitly include the spatial extent of the spongiosa, as well as the thickness of the surrounding cortical bone. These energy-dependent profiles of absorbed fractions to marrow tissues were then compared to transport simulations made within an infinite region of spongiosa. Ratios of mean absorbed fraction, as weighted by the beta energy spectra, under both transport methodologies were then assembled for the radionuclides 32P and 90Y. These ratios indicate that corrections to existing radionuclide S values for 32P can vary by as much as 5% for the male, 6% for the 82-year female, and 8% for the 86-year female. For the higher-energy beta spectrum of 90Y, these same corrections can reach 8%, 10%, and 11%, respectively.

Aged↗

Surface area overestimation within three-dimensional digital images and its consequence for skeletal dosimetry.

The most recent methods for trabecular bone dosimetry are based on Monte Carlo transport simulations within three-dimensional (3D) images of real human bone samples. Nuclear magnetic resonance and micro-computed tomography have been commonly used as imaging tools for studying trabecular microstructure. In order to evaluate the accuracy of these techniques for radiation dosimetry, a previous study was conducted that showed an overestimate in the absorbed fraction of energy for low-energy electrons emitted within the marrow space and irradiating the bone trabeculae. This problem was found to be related to an overestimate of the surface area of the true bone-marrow interface within the 3D digital images, and was identified as the surface-area effect. The goal of the present study is to better understand how this surface-area effect occurs in the case of single spheres representing individual marrow cavities within trabecular bone. First, a theoretical study was conducted which showed that voxelization of the spherical marrow cavity results in a 50% overestimation of the spherical surface area. Moreover, this overestimation cannot be reduced through a reduction in the voxel size (e.g., improved image resolution). Second, a series of single-sphere marrow cavity models was created with electron sources simulated within the sphere (marrow source) and outside the sphere (bone trabeculae source). The series of single-sphere models was then voxelized to represent 3D digital images of varying resolution. Transport calculations were made for both marrow and bone electron sources within these simulated images. The study showed that for low-energy electrons (<100 keV), the 50% overestimate of the bone-marrow interface surface area can lead to a 50% overestimate of the cross-absorbed fraction. It is concluded that while improved resolution will not reduce the surface area effects found within 3D image-based transport models, a tenfold improvement in current image resolution would compensate the associated errors in cross-region absorbed fractions for low-energy electron sources. Alternatively, other methods of defining the bone-marrow interface, such as with a polygonal isosurface, would provide improvements in dosimetry without the need for drastic reductions in image voxel size.

Biophysical Phenomena↗

Chord distributions across 3D digital images of a human thoracic vertebra.

Radiation dose estimates to the trabecular region of the skeleton are of primary importance due to recent advancements in nuclear medicine. Establishing methods for accurately calculating dose in these regions is difficult due to the complex microstructure of this anatomic site and the typical ranges of beta-particles in both bone and marrow tissues. At the present time, models of skeletal dosimetry used in clinical medicine rely upon measured distributions of straight-line path lengths (chord lengths) through bone and marrow regions. This work develops a new three-dimensional, digital method for acquiring these distributions within voxelized images. In addition, the study details the characteristics of measuring chord distributions within digital images and provides a methodology for avoiding undesirable pixel or voxel effects. The improved methodology has been applied to a digital image (acquired via NMR microscopy) of the trabecular region of a human thoracic vertebra. The resulting chord-length distributions across both bone trabeculae and bone marrow cavities were found to be in general agreement with those measured in other studies utilizing different methods. In addition, this study identified that bone and marrow space chord-length distributions are not statistically independent, a condition implicitly assumed within all current skeletal dosimetry models of electron transport. The study concludes that the use of NMR microscopy combined with the digital measurement techniques should be used to further expand the existing Reference Man database of trabecular chord distributions to permit the development of skeletal dosimetry models which are more age and gender specific.

Bone Marrow↗

Beta-particle dosimetry of the trabecular skeleton using Monte Carlo transport within 3D digital images.

Presently, skeletal dosimetry models utilized in clinical medicine simulate electron path lengths through skeletal regions based upon distributions of linear chords measured across bone trabeculae and marrow cavities. In this work, a human thoracic vertebra has been imaged via nuclear magnetic resonance (NMR) spectroscopy yielding a three-dimensional voxelized representation of this skeletal site. The image was then coupled to the radiation transport code EGS4 allowing for 3D tracing of electron paths within its true 3D structure. The macroscopic boundaries of the trabecular regions, as well as the cortex of cortical bone surrounding the bone site, were explicitly considered in the voxelized transport model. For the case of a thoracic vertebra, energy escape to the cortical bone became significant at source energies exceeding approximately 2 MeV. Chord-length distributions were acquired from the same NMR image, and subsequently used as input for a chord-based dosimetry model. Differences were observed in the absorbed fractions given by the chord-based model and the voxel transport model, suggesting that some of the input chord distributions for the chord-based models may not be accurate. Finally, this work shows that skeletal mass estimates can be made from the same NMR image in which particle transport is performed. This feature allows one to determine a skeletal S-value using absorbed fraction and mass data taken from the same anatomical tissue sample. The techniques developed in this work may be applied to a variety of skeletal sites, thus allowing for the development of skeletal dosimetry models at all skeletal sites for both males and females and as a function of subject age.

Age Factors↗

Voxel size effects in three-dimensional nuclear magnetic resonance microscopy performed for trabecular bone dosimetry.

An important problem in internal dosimetry is the assessment of energy deposition by beta particles within trabecular regions of the skeleton. Recent dosimetry methods for trabecular bone are based on Monte Carlo particle transport simulations within three-dimensional (3D) images of real human bone samples. Nuclear magnetic resonance (NMR) microscopy is a 3D imaging technique of choice due to the large signal differential between bone tissue and the water-filled marrow cavities. Image voxel sizes currently used in NMR microscopy are between 50 microm and 100 microm, but the images are time consuming to acquire and can only be performed at present for in vitro samples. It is therefore important to evaluate what resolution is best suitable in order to properly characterize the trabecular microstructure, to adequately predict the tissue dosimetry, and to minimize imaging time. In this work, a mathematical model of trabecular bone, composed of a distribution of spherical marrow cavities, was constructed. The mathematical model was subsequently voxelized with different voxel sizes (16 microm to 1,000 microm) to simulate 3D NMR images. For each image, voxels are assigned to either bone or marrow according to their enclosed marrow fraction. Next, the images are coupled to the EGS4 electron transport code and absorbed fractions to bone and marrow are calculated for a marrow source of monoenergetic electrons. Radionuclide S values are also determined for the voxelized images with results compared to data calculated for the pure mathematical sample. The comparison shows that for higher energy electrons (>400 keV), good convergence of the results is seen even within images of poor resolution. Above 400 keV, a voxel resolution as large as 300 microm results in dosimetry errors below 5%. For low-energy electrons and high-resolution images, the self-dose to marrow is also determined to within 5% accuracy. Nevertheless, increased voxelization of the image overestimates the surface area of the bone-marrow interface leading to errors in the cross-dose to bone as high as 25% for some low-energy beta emitters.

Bone Marrow↗

NMR microscopy of trabecular bone and its role in skeletal dosimetry.

One of the more intractable problems in internal dosimetry is the assessment of energy deposition by alpha and beta particles within trabecular, or cancellous, bone. In the past few years, new technologies have emerged that allow for the direct and nondestructive 3D imaging of trabecular bone with sufficient spatial resolution to characterize trabecular bone structure in a manner needed for radiation dosimetry models. High-field proton nuclear magnetic resonance (NMR) imaging is one such technology. NMR is an ideal modality for imaging trabecular bone due to the sharp contrast in proton density between the bone matrix and bone marrow regions. In this study, images of the trabecular regions within the bodies of a human thoracic vertebra have been obtained at a field strength of 14.1 T. These images were digitally processed to measure chord length distribution data through both the bone trabeculae and marrow cavities. These distributions, which were found to be qualitatively consistent with those measured by F. W. Spiers and colleagues at the University of Leeds using physical sectioning and automated light microscopy, yielded a mean trabecular thickness of 201 microm and a mean marrow cavity thickness of 998 microm. The NMR techniques developed here for vertebral imaging may be extended to other skeletal sites, allowing for improved site-specific skeletal dosimetry.

Bone Marrow↗