PubMed Health⌕ Search

Biomedical subjects

P W Skinner

Publications and source records attributed to P W Skinner.

5 recordsLinked to original sources

Delivering images to the operating room: a web-based solution.

As radiology departments become filmless, they are discovering that some areas are particularly difficult to deliver images. Many departments have found that the operating room is one such area. There are space constraints and difficulty in manipulating the images by a sterile surgeon. This report describes one method to overcome this obstacle. The author's institution has been using picture archiving and communication system (PACS) for approximately 3 years, and it has been a filmless department for 1 year. The PACS transfers images to a webserver for distribution throughout the hospital. It is accessed by Internet Explorer without any additional software. The authors recently started a pilot program in which they installed dual panel flat screen monitors in 6 operating rooms. The computers are connected to the hospital backbone by ethernet. Graphic cards installed in the computers allow the use of dual monitors. Because the surgeons were experienced in viewing cases on the enterprise web system, they had little difficulty in adapting to the operating room (OR) system. Initial reception of the system is positive. The use of the web system was found to be superior by the surgeons because of the flexibility and manipulation of the images compared with film. Images can be magnified to facilitate viewing from across the room. The ultimate goal of electronic radiology is to replace hardcopy film in all aspects. One area that PACS has difficulty in accomplishing this goal is in the operating room. Most institutions have continued to print film for the OR. The authors have initiated a project that may allow web viewing in the OR. Because of limited space in the OR, an additional computer was undesirable. The CPU tower, keyboard, and mouse were mounted on a frame on the wall. The images were displayed on 2 flat screen monitors, which simulated the viewboxes traditionally used by the surgeons. Interviews with the surgeons have found both positive and negative aspects of the system. Overall impression is good, but the timeliness of the intraoperative films needs to be improved. The author's pilot project of installing a web-based display system in the operating room still is being evaluated. Their initial results have been positive, and if there are no major problems that arise the project will be expanded. These results show that it is possible to provide image delivery to the OR over the intranet that is acceptable to the surgeons.

Computer Systems↗

Early failure of the porous-coated anatomic cemented unicompartmental knee arthroplasty: A 5- to 9-year follow-up study.

This retrospective study analyzed the results of 26 porous-coated anatomic unicompartmental knee arthroplasties to determine the failure rate, the mode of failure, and the presentation of the failure. The mean follow-up was 6.9 years. All patients were assessed using the American and Oxford knee scores. The revision rate was 42%4, with a mean revision time of 38.4 months. The commonest presentation of failure included pain (100%), decreased mobility (75%), swelling (58%), and giving way (50%). The commonest modes of failure included femoral loosening (55%), polyethylene wear (55%), loosening and polyethylene wear (72%), and fracture-dislocation of the femoral prosthesis (18%). The 42% failure rate of the porous-coated anatomic unicompartmental knee arthroplasty necessitates regular surveillance and prompt revision, if failing, to avoid osteolysis.

Aged↗

Use and abuse of performance indicators.

An audit was performed by this department after allegations by the regional health authority of low productivity. It was found that the health authority had underestimated the number of operations performed in 1983 by only 5%, but an inexact classification and grading of operations had led to errors in the performance indicators of 19.8% for the "weighted number of operations" and 34.5% for the "number of major operations per consultant." When the throughput of orthopaedic departments in districts was compared by the regional health authority it was found that such errors in performance indicators had been further compounded by the inconsistent use of population data and incorrect data on medical staffing. Medical practitioners and the health authorities are alerted to this amplification of inaccurate data. Other methods for assessing trauma and orthopaedic surgery are proposed, such as a simplification of the Office of Population Censuses and Surveys classification of surgical operations, grading operations based on time spent in the operating theatre, and provision of computer programs to code for diagnosis and operation when writing discharge summaries.

Catchment Area, Health↗

Compression screw fixation for displaced subcapital fracture of the femur. Success or failure?

We report a prospective study of 198 cases of subcapital fracture of the femur treated by closed reduction and fixation with a sliding compression screw-plate. This was done without regard to the patient's age or the Garden stage of the fracture. Early weight-bearing was encouraged. Of the displaced fractures 23% failed in the first year because of non-union or infection. Of the fractures which united 27% had developed avascular necrosis after three years. Despite this we believe that the sliding compression screw-plate, of proven value in the treatment of intertrochanteric fractures, is also useful for the fixation of subcapital fractures.

Adult↗